Submilliarcsecond VLBI observations of the close pair GC 1342 + 662 and GC 1342 + 663

Differential VLBI was simultaneously performed on the source pair GC 1342 + 662 and GC 1342 + 663 (4.4-arcminute separation) using S-band on the Goldstone/Madrid baseline. These measurements were acquired on two separate observing sessions: 30 December 1982 and 14 May 1983. The change in separation of GC 1342 + 662 relative to GC 1342 + 663 between the two epochs was 0.03 + or - 0.08 milliarcsecond. The differences of the relative position measurements between epochs of GC 1342 + 662 relative to GC 1342 + 663 were -0.29 + or - 0.05 milliarcsecond in right ascension and 0.14 + or 0.09 milliarcsecond in declination. These measurements demonstrate submilliarcsecond accuracy and repeatability. The discrepancies outside of the formal uncertainties could be attributed to the intrinsic properties of the sources such as structure and to a lesser probability, proper motion. These discrepancies could also be attributed to excursions in UT1-UTC of about four times the quoted BIH uncertainty.

Morabito, D. D.↗

Docking System With Video Feedback

Video-sensor/electronic-feedback control system being developed to provide automatic control of final stage of approach of active vehicle to passive vehicle or object. No communication between vehicles necessary. Docking target, mounted on post on passive vehicle, has three reflective dots, positions of which measured in image to determine relative position and orientation of target and vehicle. Control channels process video-sensor feedback into motion-control signals (thrustor commands in spacecraft or motor commands in robot). Conceived for use aboard chasing spacecraft to control its maneuvers in docking with chased spacecraft, concept also useful in controlling coupling of aircraft in flight or vessels on water or in controlling approach of robot to object to be manipulated.

Dabrey, Richard↗

Application of Wind Tunnel Free-Flight Technique for Wake Vortex Encounters

A wind tunnel investigation was conducted in the Langley 30- by 60-Foot Tunnel to assess the free-flight test technique as a tool in research on wake vortex encounters. A typical 17.5-percent scale business-class jet airplane model was flown behind a stationary wing mounted in the forward portion of the wind tunnel test section. The span ratio (model span-generating wingspan) was 0.75. The wing angle of attack could be adjusted to produce a vortex of desired strength. The test airplane model was successfully flown in the vortex and through the vortex for a range of vortex strengths. Data obtained included the model airplane body axis accelerations, angular rates, attitudes, and control positions as a function of vortex strength and relative position. Pilot comments and video records were also recorded during the vortex encounters.

Brandon, Jay M.↗

Modeling Surface Structure Derived from Laser Altimeter Return Waveforms Using High-Resolution Elevation Data

The upcoming generation of operational spaceborne laser altimeters (i.e VCL and GLAS) record the interaction of emitted laser radiation with terrestrial surfaces in the form of a digitized waveform. We show that we can accurately model return laser altimeter waveforms as the sum of the reflections from individual surfaces within laser footprints. In one case, we predict return waveforms using high resolution elevation data generated by a small-footprint laser altimeter in a dense tropical forest. We compare over 3000 modeled and recorded waveform pairs using the Pearson correlation. The modeled and recorded waveforms are highly correlated, with a mean correlation of 0.90 and a median of 0.95. The mean correlation is highly dependent on the relative positions of the data sets. By shifting the relative locations of the two compared data sets, we infer that the data are colocated to within 0.4$\sim$m horizontally and 0.12$\sim$m vertically. The high degree of correlation shows that we can reliably synthesize the vertical structure information measured by medium-large footprint laser altimeters for complex, dense vegetation.

Blair, J. Bryan↗

Controlling Laser Spot Size in Outer Space

Three documents discuss a method of controlling the diameter of a laser beam projected from Earth to any altitude ranging from low orbit around the Earth to geosynchronous orbit. Such laser beams are under consideration as means of supplying power to orbiting spacecraft at levels of the order of tens of kilowatts apiece. Each such beam would be projected by use of a special purpose telescope having an aperture diameter of 15 m or more. Expanding the laser beam to such a large diameter at low altitude would prevent air breakdown and render the laser beam eyesafe. Typically, the telescope would include an adaptive-optics concave primary mirror and a convex secondary mirror. The laser beam transmitted out to the satellite would remain in the near field on the telescope side of the beam waist, so that the telescope focal point would remain effective in controlling the beam width. By use of positioning stages having submicron resolution and repeatability, the relative positions of the primary and secondary mirrors would be adjusted to change the nominal telescope object and image distances to obtain the desired beam diameter (typically about 6 m) at the altitude of the satellite. The limiting distance D(sub L) at which a constant beam diameter can be maintained is determined by the focal range of the telescope 4 lambda f(sup 2) where lambda is the wavelength and f the f/number of the primary mirror. The shorter the wavelength and the faster the mirror, the longer D(sub L) becomes.

Bennett, Harold E.↗

Long-term nitrogen fertilization decreases bacterial diversity and favors the growth of Actinobacteria and Proteobacteria in agro-ecosystems across the globe

Long-term Elevated nitrogen (N) input from anthropogenic sources may cause soil acidification and decrease crop yield, yet the response of the belowground microbial community to long-term N input and the input of N combined with phosphorus (P) and potassium (K) is still poorly understood. Here, we explored the effect of long-term N and NPK fertilization on soil bacterial diversity and community composition using meta-analysis of a global dataset. Nitrogen fertilization decreased soil pH, and increased soil organic carbon (C) and available N contents. Bacterial taxonomic diversity was decreased by N fertilization alone, but was increased by NPK fertilization. The effect of N fertilization on bacterial diversity depends on soil texture and water management, but independent of crop type or N application rate. Both soil pH and organic C content were positively related to changes in bacterial diversity under N fertilization, while soil organic C was the dominant factor determining changes in bacterial diversity under NPK fertilization. Microbial biomass C decreased with decreasing bacterial diversity under long-term N fertilization. Nitrogen fertilization increased the relative abundance of copiotrophic bacteria (i.e. Proteobacteria and Actinobacteria), but reduced the abundance of oligotrophic taxa (i.e. Acidobacteria), consistent with the general life history strategy theory for bacteria. The relative abundance of Proteobacteria was also increased by NPK fertilization. The positive correlation between N application rate and the relative abundance of Actinobacteria indicates that increased N availability favored the growth of Actinobacteria. This first global analysis of long-term N and NPK fertilization effect on bacterial diversity and community composition suggests that N input decreases bacterial diversity but favors the growth of copiotrophic bacteria, providing a reference for nutrient management strategies for maintaining belowground microbial diversity in agro-ecosystems worldwide.

59 BASIC BIOLOGICAL SCIENCES↗

An MLC calibration method using a detector array

Purpose: The authors have developed a quantitative calibration method for a multileaf collimator (MLC) which measures individual leaf positions relative to the MLC backup jaw on an Elekta Synergy linear accelerator. Methods: The method utilizes a commercially available two-axis detector array (Profiler 2; Sun Nuclear Corporation, Melbourne, FL). To calibrate the MLC bank, its backup jaw is positioned at the central axis and the opposing jaw is retracted to create a half-beam configuration. The position of the backup jaws field edge is then measured with the array to obtain what is termed the radiation defined reference line. The positions of the individual leaf ends relative to this reference line are then inferred by the detector response in the leaf end penumbra. Iteratively adjusting and remeasuring the leaf end positions to within specifications completes the calibration. Using the backup jaw as a reference for the leaf end positions is based on three assumptions: (1) The leading edge of an MLC leaf bank is parallel to its backup jaw's leading edge, (2) the backup jaw position is reproducible, and (3) the measured radiation field edge created by each leaf end is representative of that leaf's position. Data from an electronic portal imaging device (EPID) were used in a similar analysis to check the results obtained with the array. Results: The relative leaf end positions measured with the array differed from those measured with the EPID by an average of 0.11 {+-}0.09 mm per leaf. The maximum leaf positional change measured with the Profiler 2 over a 3 month period was 0.51 mm. A leaf positional accuracy of {+-}0.4 mm is easily attainable through the iterative calibration process. The method requires an average of 40 min to measure both leaf banks. Conclusions: This work demonstrates that the Profiler 2 is an effective tool for efficient and quantitative MLC quality assurance and calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface navigation on Mars with a Navigation Satellite

Radiometric navigation data from the Deep Space Network (DSN) stations on the earth to transponders and other surface elements such as rovers and landers on Mars, can determine their positions to only within a kilometer in inertial space. The positional error is mostly in the z-component of the surface element parallel to the Martian spin-axis. However, with Doppler and differenced-Doppler data from a Navigation Satellite in orbit around Mars to two or more of such transponders on the planetary surface, their positions can be determined to within 15 meters (or 20 meters for one-way Doppler beacons on Mars) in inertial space. In this case, the transponders (or other vehicles) on Mars need not even be capable of directly communicating to the earth. When the Navigation Satellite data is complemented by radiometric observations from the DSN stations also, directly to the surface elements on Mars, their positions can be determined to within 3 meters in inertial space. The relative positions of such surface elements on Mars (relative to one another) in Mars-fixed coordinates, however, can be determined to within 5 meters from simply range and Doppler data from the DSN stations to the surface elements. These results are obtained from covariance studies assuming X-band data noise levels and data-arcs not exceeding 10 days. They are significant in the planning and deployment of a Mars-based navigation network necessary to support real-time operations during critical phases of manned exploration of Mars.

Vijayaraghavan, A.↗

Robotic Target-Tracking Subsystem

Position and orientation of target measured in six degrees of freedom. Robotic vision subsystem measures relative position and orientation of specially designed target. Uses standard image-processing algorithms implemented directly in circuitry instead of computer programs. This feature makes it possible to extract complete sets of target-tracking data from successive image frames at rate of 30 frames per second. Five bright circles of target positioned in such way that video images of them processed into data on position and orientation of target relative to camera. Subsystem useful in industrial assembly operation requiring automatic joining of parts initially oriented and moving randomly.

Shawaga, Lawrence M.↗

A Method for Improving Galactic Cepheid Reddenings and Distances

We present a new photometric method by which improved high-precision reddenings and true distance moduli can be determined to individual Galactic Cepheids once distance measurements are available. We illustrate that the relative positioning of stars in the Cepheid period–luminosity (PL) relation (Leavitt law) is preserved as a function of wavelength. This information then provides a powerful constraint for determining reddenings to individual Cepheids, as well as their distances. As a first step, we apply this method to the 59 Cepheids in the compilation of Fouqué et al. Updated reddenings, distance moduli (or parallaxes), and absolute magnitudes in seven (optical through near-infrared) bands are given. From these intrinsic quantities, multiwavelength PL and color–color relations are derived. We find that the V -band period–luminosity–color relation has an rms scatter of only 0.06 mag, so that individual Cepheid distances can be measured to 3%, compared with dispersions of 6 to 13% for the one-parameter K through B PL relations, respectively. This method will be especially useful in conjunction with the new accurate parallax sample upcoming from Gaia .

79 ASTRONOMY AND ASTROPHYSICS↗

Auto calibration of a cone-beam-CT

Purpose: This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. Methods: The authors use test objects containing small arbitrarily positioned radio-opaque markers. No information regarding the relative positions of the markers is used. In practice, the authors use three to eight metal ball bearings (diameter of 1 mm), e.g., positioned roughly in a vertical line such that their projection image curves on the detector preferably form large ellipses over the circular orbit. From this ellipse-to-curve mapping and also from its inversion the authors derive an explicit formula. Nonlinear optimization based on this mapping enables them to determine the six relevant parameters of the system up to the device rotation angle, which is sufficient to define the geometry of a CBCT-machine assuming a perfect rotational movement. These parameters also include out-of-plane rotations. The authors evaluate their method by simulation based on data used in two similar approaches [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004); K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)]. This allows a direct comparison of accuracy. Furthermore, the authors present real-world 3D reconstructions of a dry human spine segment and an electronic device. The reconstructions were computed from projections taken with a commercial dental CBCT device having two different focus-to-detector distances that were both calibrated with their method. The authors compare their reconstruction with a reconstruction computed by the manufacturer of the CBCT device to demonstrate the achievable spatial resolution of their calibration procedure. Results: Compared to the results published in the most closely related work [K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)], the simulation proved the greater accuracy of their method, as well as a lower standard deviation of roughly 1 order of magnitude. When compared to another similar approach [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004)], their results were roughly of the same order of accuracy. Their analysis revealed that the method is capable of sufficiently calibrating out-of-plane angles in cases of larger cone angles when neglecting these angles negatively affects the reconstruction. Fine details in the 3D reconstruction of the spine segment and an electronic device indicate a high geometric calibration accuracy and the capability to produce state-of-the-art reconstructions. Conclusions: The method introduced here makes no requirements on the accuracy of the test object. In contrast to many previous autocalibration methods their approach also includes out-of-plane rotations of the detector. Although assuming a perfect rotation, the method seems to be sufficiently accurate for a commercial CBCT scanner. For devices which require higher dimensional geometry models, the method could be used as a initial calibration procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of ion abundances on electromagnetic ion cyclotron wave growth rate in the vicinity of the plasmapause

Electromagnetic ion cyclotron (EMIC) waves in multi-ion species plasmas propagate in branches. Except for the branch corresponding to the heaviest ion species, which has only a resonance at its gyrofrequency, these branches are bounded below by a cutoff frequency and above by a resonant gyrofrequency. The condition for wave growth is determined by the thermal anisotropies of each ion species, j, which sets an upper bound, ω{sub j}{sup ∗}, on the wave frequency below which that ion species contributes positively to the growth rate. It follows that the relative positions of the cutoffs and the critical frequencies ω{sub j}{sup ∗} play a crucial role in determining whether a particular wave branch will be unstable. The effect of the magnetospheric ion abundances on the growth rate of each branch of the EMIC instability in a model where all the ion species have kappa velocity distributions is investigated by appealing to the above ideas. Using the variation of the cutoff frequencies predicted by cold plasma theory as a guide, optimal ion abundances that maximise the EMIC instability growth rate are sought. When the ring current is comprised predominantly of H{sup +} ions, all branches of the EMIC wave are destabilised, with the proton branch having the maximum growth rate. When the O{sup +} ion abundance in the ring current is increased, a decrease in the growth rate of the proton branch and cyclotron damping of the helium branch are observed. The oxygen branch, on the other hand, experiences an increase in the maximum growth rate with an increase in the O{sup +} ion abundance. When the ring current is comprised predominantly of He{sup +} ions, only the helium and oxygen branches of the EMIC wave are destabilised, with the helium branch having the maximum growth rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anthropogenic N deposition alters soil organic matter biochemistry and microbial communities on decaying fine roots

Abstract Fine root litter is a primary source of soil organic matter (SOM), which is a globally important pool of C that is responsive to climate change. We previously established that ~20 years of experimental nitrogen (N) deposition has slowed fine root decay and increased the storage of soil carbon (C; +18%) across a widespread northern hardwood forest ecosystem. However, the microbial mechanisms that have directly slowed fine root decay are unknown. Here, we show that experimental N deposition has decreased the relative abundance of Agaricales fungi (−31%) and increased that of partially ligninolytic Actinobacteria (+24%) on decaying fine roots. Moreover, experimental N deposition has increased the relative abundance of lignin‐derived compounds residing in SOM (+53%), and this biochemical response is significantly related to shifts in both fungal and bacterial community composition. Specifically, the accumulation of lignin‐derived compounds in SOM is negatively related to the relative abundance of ligninolytic Mycena and Kuehneromyces fungi, and positively related to Microbacteriaceae. Our findings suggest that by altering the composition of microbial communities on decaying fine roots such that their capacity for lignin degradation is reduced, experimental N deposition has slowed fine root litter decay, and increased the contribution of lignin‐derived compounds from fine roots to SOM. The microbial responses we observed may explain widespread findings that anthropogenic N deposition increases soil C storage in terrestrial ecosystems. More broadly, our findings directly link composition to function in soil microbial communities, and implicate compositional shifts in mediating biogeochemical processes of global significance.

Argiroff, William A.↗

The pointable multispectral linear array system and the large format camera for early 1980 shuttle payloads

Design options are described for the multispectral linear arrays which will provide data and facilities beyond those obtained by LANDSAT 1, 2, 3, and D (the thematic mapper) are considered. The features, uses, and risks of a 10M fine resolution pointable imager, a 15M/30M dual resolution pointable imager, a 30M selectable spectral resolution pointing imager, a 30M electronically pointable multi-temporal sampler, and a 40M/80M mixed resolution imager are described. A large format camera scheduled for 1981 shuttle launch which can obtain high spatial ground resolution (approximately 10M), a relative position accuracy of plus or minus 14M, and a relative heightening accuracy, by virtue of stereographic coverage, of between 7 and 28M depending on the base-to-height ratio used. A potential problem of the system is that it will orbit in the shuttle.

Slater, P. N.↗

Thruster Limitation Consideration for Formation Flight Control

Physical constraints of any real system can have a drastic effect on its performance. Some of the more recognized constraints are actuator and sensor saturation and bandwidth, power consumption, sampling rate (sensor and control-loop) and computation limits. These constraints can degrade system s performance, such as settling time, overshoot, rising time, and stability margins. In order to address these issues, researchers have investigated the use of robust and nonlinear controllers that can incorporate uncertainty and constraints into a controller design. For instance, uncertainties can be addressed in the synthesis model used in such algorithms as H(sub infinity), or mu. There is a significant amount of literature addressing this type of problem. However, there is one constraint that has not often been considered; that is, actuator authority resolution. In this work, thruster resolution and controller schemes to compensate for this effect are investigated for position and attitude control of a Low Earth Orbit formation flight system. In many academic problems, actuators are assumed to have infinite resolution. In real system applications, such as formation flight systems, the system actuators will not have infinite resolution. High-precision formation flying requires the relative position and the relative attitude to be controlled on the order of millimeters and arc-seconds, respectively. Therefore, the minimum force resolution is a significant concern in this application. Without the sufficient actuator resolution, the system may be unable to attain the required pointing and position precision control. Furthermore, fuel may be wasted due to high-frequency chattering phenomena when attempting to provide a fine control with inadequate actuators. To address this issue, a Sliding Mode Controller is developed along with the boundary Layer Control to provide the best control resolution constraints. A Genetic algorithm is used to optimize the controller parameters according to the states error and fuel consumption criterion. The tradeoffs and effects of the minimum force limitation on performance are studied and compared to the case without the limitation. Furthermore, two methods are proposed to reduce chattering and improve precision.

Yunjun Xu↗

The spectrum and position of solar noise storms at decameter wavelengths

Decametric storm radiation during the period July-August 1970 has been observed simultaneously with a high sensitivity spectrograph at Arecibo Observatory and with the log-periodic, swept-frequency array of the Clark Lake Radio Observatory. The observations complement each other; different types of fine structure emissions can be easily identified on the spectrograph records and their position can be determined from the swept-frequency recordings. The relative positions of the different emissions which have been observed during the storms are studied. Four distinct sources appear to be present. The continuum emission, the type I bursts and the flare-related type III's are all emitted at different locations. The storm type III bursts, type IIIb's and drift pairs overlap in position, but appear at different locations than the previously mentioned sources.

De La Noe, J.↗

Comparative assessment of LANDSAT-4 MSS and TM data quality for mapping applications in the southeast

The initial objectives of analyses of the MSS data are two-fold: (1) to evaluate the geodetic accuracy of CCT-P data of the test sites; and (2) to improve the geodetic accuracy by additional processing if the original data either do not meet pre-launch specifications or mapping requirements. The location of 45 ground control points (GCP) digitized from 35 U.S. Geological Survey 1:24,000 scale quadrangles (UTM coordinates) were identified in terms of pixel and scan line values. These 46 points are used to establish UTM position error vector distributions in the scene. As an initial check on the geometric reliability of the MSS data, 28 well-distributed GCPs were input to a program which compares the scaled image distances between all possible point pairs with the corresponding map distances and computes the distance differences; that is, the relative positional errors. The relative errors obtained from initial computations averaged about +/- 200 m. These errors could result from a number of sources, including misidentification of GCP locations, UTM coordinate errors introduced by the map digitizing process or errors resulting from data acquisition and geometric processing.

Welch, R.↗

Instrumented Glove Measures Positions Of Fingers

Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.