Search NASA⌕ Search

SEARCH · Search NASA

Results for “Risk ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Model to Assess the Risk of Ice Accretion Due to Ice Crystal Ingestion in a Turbofan Engine and its Effects on Performance

The occurrence of ice accretion within commercial high bypass aircraft turbine engines has been reported under certain atmospheric conditions. Engine anomalies have taken place at high altitudes that were attributed to ice crystal ingestion, partially melting, and ice accretion on the compression system components. The result was one or more of the following anomalies: degraded engine performance, engine roll back, compressor surge and stall, and flameout of the combustor. The main focus of this research is the development of a computational tool that can estimate whether there is a risk of ice accretion by tracking key parameters through the compression system blade rows at all engine operating points within the flight trajectory. The tool has an engine system thermodynamic cycle code, coupled with a compressor flow analysis code, and an ice particle melt code that has the capability of determining the rate of sublimation, melting, and evaporation through the compressor blade rows. Assumptions are made to predict the complex physics involved in engine icing. Specifically, the code does not directly estimate ice accretion and does not have models for particle breakup or erosion. Two key parameters have been suggested as conditions that must be met at the same location for ice accretion to occur: the local wet-bulb temperature to be near freezing or below and the local melt ratio must be above 10%. These parameters were deduced from analyzing laboratory icing test data and are the criteria used to predict the possibility of ice accretion within an engine including the specific blade row where it could occur. Once the possibility of accretion is determined from these parameters, the degree of blockage due to ice accretion on the local stator vane can be estimated from an empirical model of ice growth rate and time spent at that operating point in the flight trajectory. The computational tool can be used to assess specific turbine engines to their susceptibility to ice accretion in an ice crystal environment.

Jorgenson, Philip C. E.↗

Reflective Focused Schlieren System Improved for Use in 10- by 10-Foot Supersonic Wind Tunnel

The reflective focused schlieren system that was developed for use in the 10- by 10-Foot Supersonic Wind Tunnel (10x10 SWT) at the NASA Glenn Research Center at Lewis Field as part of the Unstart Test Program was improved this past year. In April 1999, the development and use of the system was presented at the Supersonic Tunnel Association International in Bedford, England. A focused schlieren system is similar to a standard schlieren system in that shock waves coming from an object in supersonic flow can be seen using a standard video camera. Unlike the standard schlieren system, which produces a two-dimensional schlieren image, a focused schlieren system can produce a threedimensional image. The preceding drawing shows the components of the reflective focused schlieren system being developed for use in the 10x10 SWT. Although the system worked well for the Unstart Test Program, it was not sensitive enough to be classified as a facility capability. Therefore, a program was implemented to improve the sensitivity of the reflective focused schlieren system so that it could be a facility capability for Glenn's 10x10 SWT. Several techniques were implemented to increase the sensitivity and to improve the overall operation of the system. These included refinement of the source grid, improvement in the cutoff grid production, improvement of the source grid and cutoff grid alignment, installation of an improved light source, and incorporation of an image-enhancing system. These changes are being implemented with the system set up in the laboratory. A checkout test of the system is planned in the 10x10 SWT in March 2000. Of these techniques, the most developed is the refinement of the source grid. The original system had a pattern of -in. by -in. squares on -in. centers (distance between the center points of adjacent squares). This gave a ratio of light to dark (reflective to nonreflective area) of 3:1. The recommended ratio is 1:1. In order to accomplish this, a pattern of -in.-diameter dots on 3/8-in. centers was developed. Preliminary tests with this pattern showed an increase in system sensitivity and image clarity. Further testing and refinement are scheduled. The former and improved dot patterns are shown. The use of glass plates to produce the cutoff grid improved the cutoff grid's quality and helped to align it with the source grid. The cutoff grid, which is the negative of the source grid, is made by exposing photography film (or glass plates) to the proper light while it is installed in the focused schlieren system. The exposed film or plate is removed from the system and then developed as a photograph negative. Because the glass plates are rigid, they eliminate the risk of distortion when the negative is reinstalled in the system and realigned with the source grid.

Williamson, Gary Scott↗

Acute Effects of Simulated Space Radiation and Micro-Gravity on Cancellous Bone Loss in Mice Tibiae

Space radiation and micro-gravity are the two major obstacles impeding human exploration of Mars and beyond. Long-duration space flights expose astronauts to high doses of high linear energy transfer (LET) radiation as well as prolonged periods of skeletal disuse due to weightlessness. One important consequence of both radiation exposure and micro-gravity is acute bone loss. However, biological responses to different radiation types and combined radiation and micro-gravity environments remain unknown. Thus, the purpose of this study is to compare the acute effects of different radiation species and simulated weightlessness on bone degeneration for the purpose of developing accurate risk assessments of prolonged space flight. Mouse models were used to simulate space flight-relevant doses of different radiation types as well as weightlessness via hind-limb unloading. Three groups of mice (n 9) were irradiated with 1 Gy (Gray) H+, 1 Gy 56Fe, and 1 Gy combined H+ and 56Fe (dual ion) respectively and compared to sham irradiated (n 9) and 2 Gy 56Fe irradiated positive controls (n 6). Two groups of mice (n 9) were hind-limb unloaded for three days and then either sham irradiated or dual ion irradiated respectively, followed by subsequent hind-limb unloading for 11 days. Cancellous tissue from tibiae metaphyses were harvested 11 days post-irradiation for ex vivo micro-computed tomography analysis. Microarchitecture parameters including bone volume to total volume ratio (BVTV), trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular spacing (Tb.S), and connectivity density (Conn.D) will be quantified using a novel automated segmentation procedure developed in our lab. The anticipated results will be instrumental in developing counter-measures against micro-gravity and radiation-induced bone loss. Moreover, possible synergistic effects may provide insight into underlying mechanisms mediating biological response.

Micro-Gravity↗

Analyzing the Subjectivity of Hole-Type Image Quality Indicators for Radiography

Hole-type penetrameters used as image quality indicators (IQIs) for radiography have an inherent degree of subjectivity to their interpretation. The 1T (one times the thickness of the penetrameter) hole is so small, it can be difficult to distinguish from noise. It is suspected that an operator’s knowledge of the true location of the 1T hole may subconsciously influence a false positive identification of the 1T hole when in fact it cannot be discerned. In the case of computed radiography (CR), the size of the phosphor particles may lead to a noise pattern with features on the scale of the 1T hole. Per NASA-STD-5009, the 1T hole must be detected in order to achieve adequate sensitivity. This is based on the historical understanding that this sensitivity will enable detection of the minimum detectable flaw sizes listed in the standard. It’s important to understand if 1T sensitivity is being achieved, and the associated risk if not. This study sought to determine the true detectability of 1T-sized holes in aluminum and Inconel by creating and inspecting a set of penetrameters with randomly placed holes. Enough holes and vacant zones were created to enable a full probability of detection study with 90% detectability, 95% confidence. Testing is ongoing, but preliminary results have shown poor detectability. The detection rate is slightly better for Inconel than aluminum, slightly better using a micro-focus vs. mini-focus tube, and definitively better for film than CR. One of the key questions of this study is whether historical requirements for film are applicable for CR, and these initial findings suggest they may not be. There is also a requirement in the NASA standard for the minimum contrast-to-noise ratio of the hole. The results have shown that this numerical threshold does not correlate well with visual detection. This raises questions about the true nature of detection, in an age of image processing vs. human judgement. As the results indicate that the detection of 1T holes is unreliable, the next challenge will be determining what sensitivity is really achieved, and what is needed.

Erin Lanigan↗

SpaceX Dragon 1 Post Flight MMOD Inspection Campaign

Introduction The SpaceX Dragon 1 spacecraft performed 20 resupply missions to the International Space Station (ISS) between 2012 and 2020. After each mission, a team from the NASA John-son Space Center Hypervelocity Impact Technology Group inspected each Dragon 1 capsule for hypervelocity impact damage features. Data from these inspections are collected into a database that includes impact feature dimensions as well as the location on the vehicle. Additional details on the type and size of particle that produced the damage site are provided when sampling data and definitive spectroscopic analysis results are available. Observation data can be compared with impact estimates from risk assessment codes as a check on the micrometeoroid and orbital debris (MMOD) environment predictions. Scope A general description of the areas of the vehicle that were inspected are provided as well as mission details such as exposure duration and launch dates. The paper documents the general inspection procedure for collection of data and the post inspection data analysis process. It also provides details of the observation data collected as well as the results of analysis of intact samples collected for spectroscopic analysis to discern the source of the impacting particle. A comparison between observed impacts and the expected number of damage features calculated by Bumper 3 with the latest MMOD environments are also presented. Findings Statistics on the >300 impact features documented in the database will provide insight into the depth to diameter ratios and other relationships. The quality of the comparison between the observations and code predictions are dependent on several factors. The paper provides de-tails of each of these variables. (1) Damage equations (2) Impact condition assumptions a. Projectile density b. Impact speed c. Impact angle (3) Analysis results a. pre-flight vs. on-orbit damage b. MMOD vs. non-MMOD Conclusions and Recommendations The ISS visiting vehicle impact database is an ongoing project. SpaceX provides crew rotations as well as resupply and cargo return with the Dragon 2 spacecraft. Sierra Space is manifested for resupply and cargo return services starting in 2023. Boeing is expected to provide crew rotations as well. All of these spacecraft will provide additional opportunities for post flight MMOD inspections of space exposed hardware. Acknowledgements Over the course of the inspection campaign various personnel at the SpaceX Texas Test Site in McGregor and at the SpaceX headquarters in Hawthorne CA provided valuable support to this activity.

James L Hyde↗

Analyzing the Subjectivity of Hole-Type Image Quality Indicators for Radiography

Hole-type penetrameters used as image quality indicators (IQIs) for radiography have an inherent degree of subjectivity to their interpretation. The 1T (one times the thickness of the penetrameter) hole is so small, it can be difficult to distinguish from noise. It is suspected that an operator’s knowledge of the true location of the 1T hole may subconsciously influence a false positive identification of the 1T hole when in fact it cannot be discerned. In the case of computed radiography (CR), the size of the phosphor particles may lead to a noise pattern with features on the scale of the 1T hole. Per NASA-STD-5009, the 1T hole must be detected in order to achieve adequate sensitivity. This is based on the historical understanding that this sensitivity will enable detection of the minimum detectable flaw sizes listed in the standard. It’s important to understand if 1T sensitivity is being achieved, and the associated risk if not. This study sought to determine the true detectability of 1T-sized holes in aluminum and Inconel by creating and inspecting a set of penetrameters with randomly placed holes. Enough holes and vacant zones were created to enable a full probability of detection study with 90% detectability, 95% confidence. Testing is ongoing, but preliminary results have shown poor detectability. The detection rate is slightly better for Inconel than aluminum, slightly better using a micro-focus vs. mini-focus tube, and definitively better for film than CR. One of the key questions of this study is whether historical requirements for film are applicable for CR, and these initial findings suggest they may not be. There is also a requirement in the NASA standard for the minimum contrast-to-noise ratio of the hole. The results have shown that this numerical threshold does not correlate well with visual detection. This raises questions about the true nature of detection, in an age of image processing vs. human judgement. As the results indicate that the detection of 1T holes is unreliable, the next challenge will be determining what sensitivity is really achieved, and what is needed.

Erin Lanigan↗

Overview of SPRITE: Saturn Probe Interior and aTmosphere Explorer Concept

The Saturn PRobe Interior and aTmosphere Explorer (SPRITE) mission concept targets high-priority Planetary Science Decadal Survey science objectives. This mission concept would deliver the SPRITE entry probe into the Saturn atmosphere to obtain in situ measurements of elemental abundances and isotopic ratios, which would help distinguish the role Saturn played in the solar system formation and co-evolution of other planets. An Atmospheric Structure Investigation sensor package on the entry probe would provide in situ measurements of the pressure/temperature and wind structure below the cloud-tops, and a Quadrupole Mass Spectrometer and Tunable Laser Spectrometer suite would determine the composition of Saturn’s atmosphere. The SPRITE mission concept described in this paper uses a solar-powered carrier-relay spacecraft to deliver the battery-powered entry probe to Saturn after a 10-year Venus-Earth-Earth gravity-assist trajectory, and then relays the probe data back to Earth during the carrier-relay spacecraft Saturn flyby. A high-heritage design approach is implemented for the flight elements to minimize technical risk and enable successful return of this high-value science data.

Cuddy, Cavan↗

OCCAMS: Optically Controlled and Corrected Active Meta-Material Space Structures

Telescopes require sub-wavelength figure (shape) error in order to achieve acceptable Strehl ratios. Traditional methods of achieving this require rigid and therefore heavy mirrors and reaction structures as well as proportionally heavy and expensive spacecraft busses and launch vehicles. This effectively limits the diameter and therefore resolution and collecting area of space optics. Large diameter telescopes must either be heavy or actively controlled. Space telescopes of the size proposed for missions such as TPF (Terrestrial Planet Finder), TPI (Terrestrial Planet Imager), etc. will likely require large active primaries and structures and corrective optics to implement downstream wavefront control. We propose a novel viable enabling technology. High resolution space imaging requires the production of lightweight large aperture optics subject to design tradespace constraints based on nanometer physical tolerances, low system aerial density, high control authority, suitable thermal and mechanical properties, deployment capability, launch vehicle volume constraints, as well as production cost and schedule risk mitigation. Segmented systems impose additional requirements on segment alignment, wavefront phasing, and telescope mass with increased edge diffraction. Photons weigh nothing. Why must even small space telescopes "weigh" tons? Our team is working to demonstrate that they do not, by leveraging 15 years of effort and a novel advanced concept.The ultimate research goal is to refine technology to produce a mission capable ultra-lightweight membrane optic whose shape can be remotely controlled using a laser beam. Using our novel optically-controlled molecular actuators allows substitution of optically-induced control for rigidity and mirror mass. In analogy with noise-canceling headphones, this technique also potentially provides a way to excite vibratory modes to couple with and damp out normal modes of oscillation induced by slewing, other motion and thermal changes, thus allowing a robust response to repointing of a large aperture.

Astronomy↗

Three-Centimeter Doppler Radar Observations of Wingtip-Generated Wake Vortices in Clear Air

This report documents a high risk, high pay-off experiment with the objective of detecting, for the first time, the presence of aircraft wake vortices in clear air using X-band Doppler radar. Field experiments were conducted in January 1995 at the Wallops Flight Facility (WFF) to demonstrate the capability of the 9.33 GHz (I=3 cm) radar, which was assembled using an existing nine-meter parabolic antenna reflector at VVTT and the receiver/transmitter from the NASA Airborne Windshear Radar-Program. A C-130-aircraft, equipped with wingtip smoke generators, created visually marked wake vortices, which were recorded by video cameras. A C-band radar also observed the wake vortices during detection attempts with the X-band radar. Rawinsonde data was used to calculate vertical soundings of wake vortex decay time, cross aircraft bearing wind speed, and water vapor mixing ratio for aircraft passes over the radar measurement range. This experiment was a pathfinder in predicting, in real time, the location and persistence of C-130 vortices, and in setting the flight path of the aircraft to optimize X-band radar measurement of the wake vortex core in real time. This experiment was conducted in support of the NASA Aircraft Vortex Spacing System (AVOSS).

Marshall, Robert E.↗

Evaluating the Performance of Hybrid Vehicles between LEO, Cislunar Space, and Mars

Nuclear power and electric propulsion technologies can enable a broad range of existing and future space mission concepts. This paper evaluates how these two technology classes, when combined into systems with various performance levels (and paired with a chemical propulsion system) affect vehicle sizing and mission feasibility for round-trip, opposition-class, crewed missions to Mars. The technology trade-space evaluated in this paper encompasses: various nuclear power system mass-efficiency levels (or power-specific mass), a range of output power levels available to the electric propulsion system, two electric propulsion thruster technologies (Hall and Magnetoplasmadynamic) at various characteristic specific impulse levels, and a range of propellant tank mass sizing coefficient. Each combination of the technologies is evaluated for the 2039 and the 2042 Mars mission opportunities for a range of imposed total mission duration constraints. The results show that synergies between technology performance levels exist and that increasing the performance of some parameters might have undesired consequences for the trajectory and vehicle. It was found that increasing the mass-efficiency of the nuclear power system is broadly beneficial, resulting in lower vehicle masses and enabling shorter mission durations. However, increasing the specific impulse of a thruster or increasing the available power level do not always yield a net benefit to the vehicle or mission; since increasing the specific impulse or power level (holding power system mass-efficiency constant) tends to decrease the vehicle thrust-to-mass ratio. Furthermore, the results show that mission feasibility is highly dependent on the mission duration; the required technology performance level to enable a mission is relaxed as the mission duration increases. Given the optimally sized vehicles resulting from the trade-space for a crewed mission to Mars, this paper also evaluates the impact of aggregating the Mars mission vehicle in Low-Earth Orbit and transferring it to the Mars mission departure node (using the on-board power and propulsion systems). The trade-space for this portion of the analysis includes the option of in-space vehicle refueling at the Mars mission departure node. The results show that on-orbit refueling can relax the required technology performance levels to achieve lower launch masses and orbit-raising durations at the cost of increased architecture complexity and risk.

Nuclear Electric Propulsion↗

Hypobaric decompression prebreathe requirements and breathing environment

To reduce incidence of decompression sickness (DCS), prebreathing 100 percent oxygen to denitrogenate is required prior to hypobaric decompressions from a sea level pressure breathing environment to pressures lower than 350 mm Hg (20,000 ft; 6.8 psia). The tissue ratio (TR) of such exposures equals or exceeds 1.7; TR being the tissue nitrogen pressure prior to decompression divided by the total pressure after decompression (((0.781)(14.697))/6.758). Designing pressure suits capable of greater pressure differentials, lower TR's, and procedures which limit the potential for DCS occurrence would enhance operational efficiency. The current 10.2 psia stage decompression prior to extravehicular activity (EVA) from the Shuttle in the 100 percent oxygen, 4.3 psia suit, results in a TR of 1.65 and has proven to be relatively free of DCS. Our recent study of zero-prebreathe decompressions to 6.8 psia breathing 100 percent oxygen (TR = 1.66) also resulted in no DCS (N = 10). The level of severe, Spencer Grades 3 or 4, venous gas emboli (VGE) increased from 0 percent at 9.5 psia to 40 percent at 6.8 psia yielding a Probit curve of VGE risk for the 51 male subjects who participated in these recent studies. Earlier, analogous decompressions using a 50 percent oxygen, 50 percent nitrogen breathing mixture resulted in one case of DCS and significantly higher levels of severe VGE, e.g., at 7.8 psia, the mixed gas breathing environment resulted in a 56 percent incidence of severe VGE versus 10 percent with use of 100 percent oxygen. The report of this study recommended use of 100 percent oxygen during zero-prebreathe exposure to 6.8 psia if such a suit could be developed. For future, long-term missions, we suggest study of the effects of decompression over several days to a breathing environment of 150 mmHg O2 and approximately 52 mmHg He as a means of eliminating DCS and VGE hazards during subsequent excursions. Once physiologically adapted to a 4 psia vehicle, base, or space station segment, crew members could use greatly simplified EVA suits with greater mobility and no prebreathe requirement.

Webb, James T.↗

Mapping Near-Surface Salinization Using Long-wavelength AIRSAR

In May 1999, NASA's Jet Propulsion Laboratory acquired airborne synthetic aperture radar (AIRSAR) data over the Hatchel and Montague Test Sites in Texas. We analyzed P- and L-band polarimetric radar data from these AIRSAR missions to assess whether AIRSAR could be used as a rapid and remote platform for screening large areas at risk for near-surface soil and water salinization. Ongoing geological, geophysical, and hydrological studies at the Hatchel Test Site in Runnels County and the Montague Test Site in Montague County have demonstrated the utility of high-resolution airborne electromagnetic (EM) induction in mapping electrical conductivity changes that accompany shallow natural and oil-field related salinization at these sites in the Colorado and Red River basins. We compared AIRSAR and airborne EM data quantitatively by (1) selecting representative flight lines from airborne EM surveys of the Hatchel and Montague sites, (2) extracting measurement locations and apparent conductivities at the highest available EM frequency, (3) identifying and extracting all P- and L-band backscatter intensities for all locations within 5 m of an airborne EM measurement, and (4) examining the spatial and magnitude relationships between apparent conductivity and all radar polarization and polarization-ratio combinations. For both test sites, backscatter intensity in all individual P- and L-band polarizations was slightly negatively correlated with apparent conductivity. In most modes this was manifested as a decrease in the range and magnitude of backscatter intensity as apparent conductivity increased. Select single-band and cross-band polarization ratios exhibited somewhat higher correlation with apparent conductivity by partly diminishing the dominance of the vegetation contribution to V backscatter intensity. The highest correlation with conductivity was obtained using the L-band vertical- to cross-polarization ratio, the P-band vertical- to L-band cross-polarization ratio, and the P-band vertical-to cross-polarization ratio. These correlations were higher for the more arid (and less electrically conductive) Hatchel Test Site than they were for the Montague Test Site.

Paine, Jeffery G.↗

Latex–collagen membrane: an alternative treatment for tibial bone defects

Due to the difficulty of consolidation, the risk of fractures, and the high cost of therapy, the orthopedic field views the restoration of bony defects or post-traumatic diseases as a significant issue. In recent years, efforts have been made toward guided bone regeneration as a viable solution. In this study, natural rubber latex (NRL) and latex–collagen (NRL-COL) membranes were developed and characterized, and their effects on bone regeneration in rat tibial lesions were assessed. According to the physicochemical findings, the hydrolyzed COL was effectively incorporated into the NRL membrane to produce a more robust membrane (348% increase in stress) and showed good biocompatibility for human dermal fibroblast cells and in hemolytic activity assay. According to bone analysis using computed microtomography, a substantial difference in bone volume (BV) was found among NRL, control (CONT), and NRL-COL. NRL-COL exhibited the greatest value for the bone volume/total volume ratio (BV/TV). The presence of NRL and COL was significant for the analysis of BV and BV/TV, respectively. All the experimental groups demonstrated a higher bone quality and fracture resistance, as shown by the mechanical properties of the bone. In the COL group, both neoformation of bone and total collagen levels were greater, indicating that treated defects had been closed and mature bone cells were present. Due to its angiogenic properties and the low cost of NRL membrane production, the NRL-COL membrane could be a good substitute for upcoming bone regeneration applications.

Marcela Britto de Paiva↗

Comprehensive Astronaut Immune Assessment Following a Short-Duration Space Flight

Immune system dysregulation has been demonstrated to occur during spaceflight and has the potential to cause serious health risks to crewmembers participating in exploration class missions. As a part of an ongoing NASA flight experiment assessing viral immunity (DSO-500), a generalized immune assessment was performed on 3 crewmembers who participated in the recent STS-114 Space Shuttle mission. The following assays were performed: (1) comprehensive immunophenotype analysis; (2) T cell function/intracellular cytokine profiles; (4) secreted Th1/Th2 cytokine profiles via cytometric bead array. Immunophenotype analysis included a leukocyte differential, lymphocyte subsets, T cell subsets, cytotoxic/effector CD8+ T cells, memory/naive T cell subsets and constitutively activated T cells. Study timepoints were L-180, L-65, L-10, R+0, R+3 and R+14. Detailed data are presented in the poster text. As expected from a limited number of human subjects, data tended to vary with respect to most parameters. Specific post-flight alterations were as follows (subject number in parentheses): Granulocytosis (2/3), reduced NK cells (3/3), elevated CD4/CD8 ratio (3/3), general CD8+ phenotype shift to a less differentiated phenotype (3/3), elevated levels of memory CD4+ T cells (3/3), loss of L-selectin on T cell subsets (3/3), increased levels of activated T cells (2/3), reduced IL-2 producing T cell subsets (3/3), levels of IFNg producing T cells were unchanged. CD8+ T cell expression of the CD69 activation markers following whole blood stimulation with SEA+SEB were dramatically reduced postflight (3/3), whereas other T cell function assessments were largely unchanged. Cytometric bead array assessment of secreted T cell cytokines was performed, following whole blood stimulation with either CD3/CD28 antibodies or PMA+ionomycin for 48 hours. Specific cytokines assessed were IFNg, TNFa, IL-2, IL-4, IL-5, IL-10. Following CD3/CD28 stimulation, all three crewmembers had a mission-associated reduction in the levels of secreted IFNg. One crewmember had a post-flight inversion in the IFNg/IL-10 ratio postflight, which trended back to baseline by R+14. Detailed cytokine data are presented in the poster text. This testing regimen was designed to correlate immunophenotype changes (thought to correspond to specific in-vivo immune responses or pathogenesis), against altered leukocyte function and cytokine profiles. In-flight studies are required to determine if post-flight alterations are reflective of the in-flight condition, or are a response to landing and readaptation.

Crucian, Brian↗

Treatment of hypertension with perindopril reduces plasma atrial natriuretic peptide levels, left ventricular mass, and improves echocardiographic parameters of diastolic function

BACKGROUND: Hypertension is a major independent risk factor for cardiac deaths, and diastolic dysfunction is a usual finding during the course of this disease. HYPOTHESIS: This study was designed to investigate the effects of chronic therapy with perindopril on left ventricular (LV) mass, left atrial size, diastolic function, and plasma level of atrial natriuretic peptide (ANP) in patients with hypertension. METHODS: Twenty four patients who had not been previously taking any antihypertensive medication and without prior history of angina pectoris, myocardial infarction, congestive heart failure, dysrhythmias, valvular heart disease, or systemic illnesses received 4-8 mg/day of perindopril orally. Echocardiographic studies were acquired at baseline and 6 months after the initiation of therapy. RESULTS: Systolic and diastolic blood pressure decreased from 174 +/- 19.7 and 107.5 +/- 7.8 mmHg to 134 +/- 10.6 and 82 +/- 6.7 mmHg, respectively (p < 0.001). Left ventricular mass decreased from 252.4 +/- 8.3 to 205.7 +/- 7.08 g and left atrial volume from 20.4 +/- 5.1 to 17.6 +/- 5.2 ml, respectively (p < 0.001). Transmitral Doppler early and atrial filling velocity ratio (E/A) increased from 0.69 +/- 0.06 to 0.92 +/- 0.05 m/s and plasma ANP level decreased from 71.9 +/- 11.7 to 35.3 +/- 7.8 pg/ml (p < 0.001). Reduction of LV mass correlated positively with a reduction in ANP levels (r = 0.66, p < 0.0005). CONCLUSIONS: Perindopril caused a significant reduction of LV mass, left atrial volume, and plasma ANP levels, as well as improvement in Doppler parameters of LV filling in this group of patients with hypertension.

NASA Program Biomedical Research and Countermeasur↗

A Modular Aerospike Engine Design Using Additive Manufacturing

A modular aerospike engine concept has been developed with the objective of demonstrating the viability of the aerospike design using additive manufacturing techniques. The aerospike system is a self-compensating design that allows for optimal performance over the entire flight regime and allows for the lowest possible mass vehicle designs. At low altitudes, improvements in Isp can be traded against chamber pressure, staging, and payload. In upper stage applications, expansion ratio and engine envelope can be traded against nozzle efficiency. These features provide flexibility to the System Designer optimizing a complete vehicle stage. The aerospike concept is a good example of a component that has demonstrated improved performance capability, but traditionally has manufacturing requirements that are too expensive and complex to use in a production vehicle. In recent years, additive manufacturing has emerged as a potential method for improving the speed and cost of building geometrically complex components in rocket engines. It offers a reduction in tooling overhead and significant improvements in the integration of the designer and manufacturing method. In addition, the modularity of the engine design provides the ability to perform full scale testing on the combustion devices outside of the full engine configuration. The proposed design uses a hydrocarbon based gas-generator cycle, with plans to take advantage of existing powerhead hardware while focusing DDT&E resources on manufacturing and sub-system testing of the combustion devices. The major risks for the modular aerospike concept lie in the performance of the propellant feed system, the structural integrity of the additive manufactured components, and the aerodynamic efficiency of the exhaust flow.

Peugeot, John↗

Using DNA Damage to Investigate the Individual Variability of Human Sensitivity to Ionizing Radiation

High-LET ionizing radiation is a major occupational health hazard for astronauts, but risk assessment remains elusive due to limited epidemiological data. Identifying genetic factors modulating the individual radiation response may be the most effective strategy to provide individualized risk management for long-duration high-radiation missions. We have started tackling the challenge of predicting individual risks by identifying human genetic loci associated with various radiation sensitivity phenotypes in primary blood mononuclear cells from a relatively large healthy human cohort. To date, we have performed the isolation of PBMCs from 768 subjects of the same ethnicity, and irradiated PBMCs from 576 subjects with 1 and 3 particles/100µm2 of 600 MeV/n 56Fe, 350 MeV/n 40Ar and 350 MeV/n 28Si ions. The phenotypes of interest were: number of radiation-induced foci (or RIFs), CellROX oxidative stress responses and cell death, at 4h and 24h following irradiation. We have observed a significant inter-individual variability at 0 Gy between the 576 studied subjects, with a mean fold difference between the 10% lowest and highest responders of 5.6 of RIFs/cell, 7.9 in mean CellRox intensity, and 9.3 in percentage of dead cells. In order to better assess genetic factors influencing DNA repair, we used a metric previously introduced by our group to sort out radiation sensitivity phenotypes in mice: i.e. the ratio of the first to the second slope of RIFs/cell (between 0 and 1, and between 1 and 3 particle/100µm2). Preliminary data on 192 individuals showed a distribution of low-dose responders (ratio > 1) to high-dose responders (ratio < 1) at 4h of 12%, 55% and 52% respectively for Fe, Ar and Si. The average value for the first and the second slopes was very similar for the two lowest LET (0.10 [-0.26;0.58] and 0.09 [-0.45;0.41] for Ar, 0.07 [-0.27;0.38] and 0.08 [-0.19;0.42] for Si), indicating a linear dose response across both fluence. Fe showed clear saturation for the highest dose with a slope of -0.09 [-0.86;1.51] against 0.68 [-2.21;2.20] for the low dose range, which probably reflects that many PBMCs are beyond repair at the high dose. Note that other significances were found for additional factors such as BMI and age whereas none were found for sex. GWAS will be performed on all phenotypes upon completion of measurements.

Pariset, E.↗

Using DNA Damage to Investigate the Individual Variability of Human Sensitivity to Ionizing Radiation

High-LET ionizing radiation is a major occupational health hazard for astronauts, but risk assessment remains elusive due to limited epidemiological data. Identifying genetic factors modulating the individual radiation response may be the most effective strategy to provide individualized risk management for long-duration high-radiation missions. We have started tackling the challenge of predicting individual risks by identifying human genetic loci associated with various radiation sensitivity phenotypes in primary blood mononuclear cells from a relatively large healthy human cohort. To date, we have performed the isolation of PBMCs from 768 subjects of the same ethnicity, and irradiated PBMCs from 576 subjects with 1 and 3 particles/100µm2 of 600 MeV/n 56Fe, 350 MeV/n 40Ar and 350 MeV/n 28Si ions. The phenotypes of interest were: number of radiation-induced foci (or RIFs), CellROX oxidative stress responses and cell death, at 4h and 24h following irradiation. We have observed a significant inter-individual variability at 0 Gy between the 576 studied subjects, with a mean fold difference between the 10% lowest and highest responders of 5.6 of RIFs/cell, 7.9 in mean CellRox intensity, and 9.3 in percentage of dead cells. In order to better assess genetic factors influencing DNA repair, we used a metric previously introduced by our group to sort out radiation sensitivity phenotypes in mice: i.e. the ratio of the first to the second slope of RIFs/cell (between 0 and 1, and between 1 and 3 particle/100µm2). Preliminary data on 192 individuals showed a distribution of ?low-dose responders? (ratio > 1) to ?high-dose responders? (ratio < 1) at 4h of 12%, 55% and 52% respectively for Fe, Ar and Si. The average value for the first and the second slopes was very similar for the two lowest LET (0.10 [-0.26;0.58] and 0.09 [-0.45;0.41] for Ar, 0.07 [-0.27;0.38] and 0.08 [-0.19;0.42] for Si), indicating a linear dose response across both fluence. Fe showed clear saturation for the highest dose with a slope of -0.09 [-0.86;1.51] against 0.68 [-2.21;2.20] for the low dose range, which probably reflects that many PBMCs are beyond repair at the high dose. Note that other significances were found for additional factors ? such as BMI and age ? whereas none were found for sex. GWAS will be performed on all phenotypes upon completion of measurements.

Pariset, E.↗