Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCATTERING FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Relationship Between the Atomic Pair Distribution Function and Small-Angle Scattering: Implications for Modeling of Nanoparticles

The relationship between the equations used in the atomic pair distribution function (PDF) method and those commonly used in small-angle-scattering (SAS) analyses is explicitly shown. The origin of the sloping baseline, -4{pi}r{rho}{sub 0}, in PDFs of bulk materials is identified as originating from the SAS intensity that is neglected in PDF measurements. The nonlinear baseline in nanoparticles has the same origin, and contains information about the shape and size of the nanoparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recovering non-Maxwellian particle velocity distribution functions from collective Thomson-scattered spectra

Collective optical Thomson scattering (TS) is a diagnostic commonly used to characterize plasma parameters. These parameters are typically extracted by a fitting algorithm that minimizes the difference between a measured scattered spectrum and an analytic spectrum calculated from the velocity distribution function (VDF) of the plasma. However, most existing TS analysis algorithms assume that the VDFs are Maxwellian, and applying an algorithm that makes this assumption does not accurately extract the plasma parameters of a non-Maxwellian plasma due to the effect of non-Maxwellian deviations on the TS spectra. We present new open-source numerical tools for forward modeling analytic spectra from arbitrary VDFs and show that these tools are able to more accurately extract plasma parameters from synthetic TS spectra generated by non-Maxwellian VDFs compared to standard TS algorithms. Estimated posterior probability distributions of fits to synthetic spectra for a variety of example non-Maxwellian VDFs are used to determine uncertainties in the extracted plasma parameters and show that correlations between parameters can significantly affect the accuracy of fits in plasmas with non-Maxwellian VDFs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral deconvolution without the deconvolution: Extracting temperature from x-ray Thomson scattering spectra without the source-and-instrument function

X-ray Thomson scattering (XRTS) probes the dynamic structure factor of the system, but the measured spectrum is broadened by the combined source-and-instrument function (SIF) of the setup. In order to extract properties such as temperature from an XRTS spectrum, the broadening by the SIF needs to be removed. Recent work [Dornheim et al. Nat. Commun. 13 , 7911 (2022)] has suggested that the SIF may be deconvolved using the two-sided Laplace transform. However, the extracted information can depend strongly on the shape of the input SIF, and the SIF is in practice challenging to measure accurately. Here, we propose an alternative approach: we demonstrate that considering ratios of Laplace-transformed XRTS spectra collected at different scattering angles is equivalent to performing the deconvolution, but without the need for explicit knowledge of the SIF. From these ratios, it is possible to directly extract the temperature from the scattering spectra, when the system is in thermal equilibrium. We find the method to be generally robust to spectral noise and physical differences between the spectrometers, and we explore situations in which the method breaks down. Furthermore, the fact that consistent temperatures can be extracted for systems in thermal equilibrium indicates that non-equilibrium effects could be identified by inconsistent temperatures of a few eV between the ratios of three or more scattering angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaporation and scattering of neon, methane, and water from a dodecane flat liquid jet

The evaporation and scattering of Ne, CD 4 , and D 2 O from a dodecane flat liquid jet are investigated in a molecular beam apparatus. The experiment yields translational energy distributions as a function of scattering angle by means of a rotatable mass spectrometer. In the evaporation experiments, one observes a Maxwell–Boltzmann distribution with a cos $θ$ angular distribution superimposed on a weak, isotropic background. The scattering experiments show contributions from impulsive scattering and thermal desorption. At select incident angles for the three systems, angular distributions show super-specular scattering for the impulsive scattering channel, an effect attributed to anisotropic momentum transfer to the liquid surface. The impulsive scattering channel is analyzed with a soft-sphere model to explore energy transfer between the scatterer and liquid as a function of deflection angle. In conclusion, compared to Ne scattering, the polyatomic gases exhibit more thermal desorption and, in the impulsive scattering channel, a higher degree of internal excitation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-FG-CAMPUS-IeP1-01: Alternative K-Edge Filters for Low-Energy Image Acquisition in Contrast Enhanced Spectral Mammography

Purpose: In Contrast Enhanced Spectral Mammography (CESM), Rh filter is often used during low-energy image acquisition. The potential for using Ag, In and Sn filters, which exhibit K-edge closer to, and just below that of Iodine, instead of the Rh filter, was investigated for the low-energy image acquisition. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for 50µm Rh were compared with other potential K-edge filters (Ag, In and Sn), all with K-absorption edge below that of Iodine. Two strategies were investigated: fixed kVp and filter thickness (50µm for all filters) resulting in HVT variation, and fixed kVp and HVT resulting in variation in Ag, In and Sn thickness. Monte Carlo simulations (GEANT4) were conducted to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Rh and other K-edge filters. Results: Ag, In and Sn filters (50µm thick) increased photon fluence/mAs by 1.3–1.4, 1.8–2, and 1.7–2 at 28-32 kVp compared to 50µm Rh, which could decrease exposure time. Additionally, the fraction of spectra closer to and just below Iodine’s K-edge increased with these filters, which could improve post-subtraction image contrast. For HVT matched to 50µm Rh filtered spectra, the thickness range for Ag, In, and Sn were (41,44)µm, (49,55)µm and (45,53)µm, and increased photon fluence/mAs by 1.5–1.7, 1.6–2, and 1.6–2.2, respectively. Monte Carlo simulations showed that neither the SPR nor the scatter PSF of Ag, In and Sn differed from Rh, indicating no additional detriment due to x-ray scatter. Conclusion: The use of Ag, In and Sn filters for low-energy image acquisition in CESM is potentially feasible and could decrease exposure time and may improve post-subtraction image contrast. Effect of these filters on radiation dose, contrast, noise and associated metrics are being investigated. Funding Support: Supported in part by NIH R01CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

WE-DE-207B-08: Towards Standardization of X-Ray Filters in Digital Mammography-Enabled Breast Tomosynthesis Systems

Purpose: In digital breast tomosynthesis (DBT) systems capable of digital mammography (DM), Al filters are used during DBT and K-edge filters during DM. The potential for standardizing the x-ray filters with Al, instead of K-edge filters, was investigated with intent to reduce exposure duration and to promote a simpler system design. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for K-edge filters (50µm Rh; 50µm Ag) were compared with Al filters of varying thickness. Two strategies for matching the HVT from K-edge and Al filtered spectra were investigated: varying the kVp for fixed Al thickness, or varying the Al thickness at matched kVp. For both strategies, Al filters were an order of magnitude thicker than K-edge filters. Hence, Monte Carlo simulations were conducted with the GEANT4 toolkit to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Al and K-edge filters. Results: Results show the potential for replacing currently used Kedge filters with Al. For fixed Al thickness (700µm), ±1 kVp and +(1–3) kVp change, matched HVT of Rh and Ag filtered spectra. At matched kVp, Al thickness range (650,750)µm and (750,860)µm matched the HVT from Rh and Ag filtered spectra. Photon fluence/mAs with Al filters were 1.5–2.5 times higher, depending on kVp and Al thickness, compared to K-edge filters. Although Al thickness was an order higher than K-edge filters, neither the SPR nor the scatter PSF differed from K-edge filters. Conclusion: The use of Al filters for digital mammography is potentially feasible. The increased fluence/mAs with Al could decrease exposure duration for the combined DBT+DM exam and simplify system design. Effect of x-ray spectrum change due to Al filtration on radiation dose, signal, noise, contrast and related metrics are being investigated. Funding support: Supported in part by NIH R21CA176470 and R01CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Systematic study of the surface properties of the nuclear potential with high precision large-angle quasi-elastic scatterings

High precision excitation functions of large-angle quasi-elastic scattering for the systems of {sup 16}O+{sup 208}Pb, {sup 196}Pt, {sup 184}W, and {sup 154,152}Sm at energies well below the Coulomb barrier were measured. The surface diffuseness parameters of the real part of the Woods-Saxon potential have been extracted from the single-channel and coupled-channels calculations, respectively. By considering the effect of couplings, the extracted diffuseness parameters are in the range from 0.64 to 0.69 fm, which is close to the values extracted from the systematic analyses of elastic and inelastic scattering data. On the other hand, single-channel calculations give somewhat larger values in the range from 0.68 to 0.77 fm, especially for systems with deformed target nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elastic backscattering measurements for {sup 6}Li+{sup 28}Si at sub- and near-barrier energies

Elastic backscattering measurements were performed for the weakly bound nucleus {sup 6}Li on a {sup 28}Si target at sub- and near-barrier energies (0.6 to 1.3 V{sub C.B.}). Excitation functions of elastic scattering cross sections were measured at 150 deg. and 170 deg. and the corresponding ratios to Rutherford scattering and relevant barrier distributions were formed. The results are discussed in terms of the potential threshold anomaly and the reaction mechanisms involved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Green's function for the time-dependent scattering problem in the fractional quantum mechanics

We study the Green's function of the time-dependent 3D space-fractional Schroedinger equation for the scattering problem in the fractional quantum mechanics. The Green's function is expressed in terms of Fox's H-function and in a computable series form. We get the asymptotic formula of the Green's function, and apply it to obtain the approximate wave function for the fractional quantum scattering problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electroweak gauge boson parton distribution functions

Transverse and longitudinal electroweak gauge boson parton distribution functions (PDFs) are calculated in terms of deep-inelastic scattering structure functions, following the recently developed method to determine the photon PDF. The calculation provides initial conditions at the electroweak scale for PDF evolution to higher energies. Numerical results for the W ± and Z transverse, longitudinal and polarized PDFs, as well as the γZ transverse and polarized PDFs are reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Role of the Final-State Interaction and Three-Body Force on the Longitudinal Response Function of {sup 4}He

We present an ab initio calculation of the longitudinal electron scattering response function off {sup 4}He with two- and three-nucleon forces and compare to experimental data. The full four-body continuum dynamics is considered via the Lorentz integral transform method. The importance of the final-state interaction is shown at various energies and momentum transfers q. The three-nucleon force reduces the quasielastic peak by 10% for q between 300 and 500 MeV/c. Its effect increases significantly at lower q, up to about 40% at q=100 MeV/c. At very low q, however, data are missing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Surface roughness of anodized titanium coatings.

Samples of grade five 6Al4V titanium alloy were coated with two commercial fluoropolymer anodizations (Tiodize and Canadize) and compared. Neither coating demonstrates significant outgassing. The coatings show very similar elemental analysis, except for the presence of lead in the Canadize coating, which may account for its lower surface friction in humid environments. Surface roughness has been compared by SEM, contact profilometry, optical profilometry, power spectral density and bidirectional scattering distribution function (BSDF). The Tiodize film is slightly smoother by all measurement methods, but the Canadize film shows slightly less scatter at all angles of incidence. Both films exhibited initial friction coefficients of 0.2 to 0.4, increasing to 0.4 to 0.8 after 1000 cycles of sliding due to wear of the coating and ball. The coatings are very similar and should behave identically in most applications.

36 MATERIALS SCIENCE↗

Second order Møller-Plesset and coupled cluster singles and doubles methods with complex basis functions for resonances in electron-molecule scattering

The method of complex basis functions is applied to molecular resonances at correlated levels of theory. Møller-Plesset perturbation theory at second order and equation-of-motion electron attachment coupled-cluster singles and doubles (EOM-EA-CCSD) methods based on a non-Hermitian self-consistent-field reference are used to compute accurate Siegert energies for shape resonances in small molecules including N 2 - , CO - , CO 2 - , and CH 2 O - . Analytic continuation of complex θ-trajectories is used to compute Siegert energies, and the θ-trajectories of energy differences are found to yield more consistent results than those of total energies. Furthermore, the ability of such methods to accurately compute complex potential energy surfaces is investigated, and the possibility of using EOM-EA-CCSD for Feshbach resonances is explored in the context of e-helium scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPATIALLY RESOLVING THE HK Tau B EDGE-ON DISK FROM 1.2 TO 4.7 {mu}m: A UNIQUE SCATTERED LIGHT DISK

We present spatially resolved scattered light images of the circumstellar disk around HK Tau B at 3.8 and 4.7 {mu}m taken with the Keck Telescope Laser Guide Star Adaptive Optics (AO) system, and 1.6-2.12 {mu}m images taken with the Very Large Telescope/NACO AO system. Combined with previously published optical Hubble Space Telescope data, we investigate the spatially resolved scattered light properties of this edge-on circumstellar disk and probe for the presence of large grains. The 0.6-3.8 {mu}m scattered light observations reveal strong, and in some cases, unusual, wavelength dependencies in the observed disk morphology. The separation between the two scattered light nebulae, which is directly proportional to the disk-mass-opacity product, decreases by 30% between 0.6 and 3.8 {mu}m. Over the same wavelength range, the FWHM of the disk nebulosity declines by a factor of two, while the flux ratio between the two nebulae increases by a factor of {approx}8. No other disk known to date shows a flux ratio that increases with wavelength. Both the FWHM and nebula flux ratio are affected by the scattering phase function and the observed behavior can most readily be explained by a phase function that becomes more forward throwing with wavelength. The multi-wavelength scattered light observations also confirm the asymmetric nature of the disk and show that the level of asymmetry is a function of wavelength. We use the MCFOST radiative transfer code to model the disk at four wavelengths, corresponding to the I, H, Ks, and L' bandpasses. A single power-law grain size distribution can recreate the observed disk properties simultaneously at all four wavelengths. Bayesian analysis of the dust parameters finds a 99% probability that the maximum grain size is 5.5 {mu}m or larger. We also find that the grain size distribution is steep, with a 99% probability of a power-law index of 4.2 or larger, suggesting that these large grains are a small fraction of the overall dust population. The best-fit dust asymmetry parameter for each individual wavelength shows an unusual behavior, increasing with wavelength from the optical through the near-infrared, peaking at {approx}0.8 between 2.2 and 3.8 {mu}m, then decreasing by a factor of two by {approx}12 {mu}m. Comparing the wavelength dependence of the asymmetry parameter for HK Tau B with those for the interstellar medium (ISM) and dark cloud dust models, we find considerable evolution from an ISM state and argue for the presence of grain growth within the disk. Further, comparing the wavelength dependence of the asymmetry parameter for GG Tau, HV Tau C, and HK Tau B, the three disks that have been spatially resolved in scattered light between 0.8 and 3.8 {mu}m, finds a diverse range of dust properties, indicating differing degrees of grain growth for disks at a similar age.

79 ASTRONOMY AND ASTROPHYSICS↗

Semi-inclusive deep-inelastic scattering, parton distributions, and fragmentation functions at a future electron-ion collider

We present a quantitative assessment of the impact a future electron-ion collider would have in the determination of parton distribution functions in the proton and parton-to-hadron fragmentation functions through semi-inclusive deep-inelastic electron-proton scattering data. Specifically, we estimate the kinematic regions for which the forthcoming data are expected to have the most significant impact in the precision of these distributions, computing the respective correlation and sensitivity coefficients. Using a reweighting technique for the sets of simulated data with their realistic uncertainties for two different center-of-mass energies, we analyze the resulting new sets of parton distribution functions and fragmentation functions, which have significantly reduced uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quasielastic scattering with the relativistic Green’s function approach

A relativistic model for quasielastic (QE) lepton-nucleus scattering is presented. The effects of final-state interactions (FSI) between the ejected nucleon and the residual nucleus are described in the relativistic Green’s function (RGF) model where FSI are consistently described with exclusive scattering using a complex optical potential. The results of the model are compared with experimental results of electron and neutrino scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗