Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHADING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

An Investigation of Strategies for Sensing Window Attachment Position: Survey of Candidate Technologies, Evaluation, and Deployment Recommendations

While windows are desirable feature in buildings for views, daylighting, and aesthetics, it is important to recognize that windows are a major contributor to a building’s energy load. Interior window coverings, such as shades and blinds, can help improve the energy performance of windows without sacrificing the benefits; however, while appropriate use of window coverings provide the potential for energy savings, there is little consensus regarding how occupants typically use these window attachments, which sometimes puts into question how much energy they actually save in an occupied home. Automated shading control strategies can reduce the uncertainty of energy savings; however, users can overwrite pre-defined schedules or write their own shade control programs to reach their personal comfort and privacy goals. Because it is difficult to identify how occupants interact with window shades, it is difficult to identify the energy savings potential of blinds. To address this problem, this study was developed to identify a candidate sensor that can be deployed to sense blind position. The intended application for this sensor is deployment in energy efficiency field studies so that shade usage can be measured to better understand results and identify the energy impact of specific window attachment technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Performance Building Facade Solutions - PIER Final Project Report

Building facades directly influence heating and cooling loads and indirectly influence lighting loads when daylighting is considered, and are therefore a major determinant of annual energy use and peak electric demand. Facades also significantly influence occupant comfort and satisfaction, making the design optimization challenge more complex than many other building systems.This work focused on addressing significant near-term opportunities to reduce energy use in California commercial building stock by a) targeting voluntary, design-based opportunities derived from the use of better design guidelines and tools, and b) developing and deploying more efficient glazings, shading systems, daylighting systems, facade systems and integrated controls. This two-year project, supported by the California Energy Commission PIER program and the US Department of Energy, initiated a collaborative effort between The Lawrence Berkeley National Laboratory (LBNL) and major stakeholders in the facades industry to develop, evaluate, and accelerate market deployment of emerging, high-performance, integrated facade solutions. The LBNL Windows Testbed Facility acted as the primary catalyst and mediator on both sides of the building industry supply-user business transaction by a) aiding component suppliers to create and optimize cost effective, integrated systems that work, and b) demonstrating and verifying to the owner, designer, and specifier community that these integrated systems reliably deliver required energy performance. An industry consortium was initiated amongst approximately seventy disparate stakeholders, who unlike the HVAC or lighting industry, has no single representative, multi-disciplinary body or organized means of communicating and collaborating. The consortium provided guidance on the project and more importantly, began to mutually work out and agree on the goals, criteria, and pathways needed to attain the ambitious net zero energy goals defined by California and the US.A collaborative test, monitoring, and reporting protocol was also formulated via the Windows Testbed Facility in collaboration with industry partners, transitioning industry to focus on the importance of expecting measured performance to consistently achieve design performance expectations. The facility enables accurate quantification of energy use, peak demand, and occupant comfort impacts of synergistic facade-lighting-HVAC systems on an apples-to-apples comparative basis and its data can be used to verify results from simulations. Emerging interior and exterior shading technologies were investigated as potential near-term, low-cost solutions with potential broad applicability in both new and retrofit construction. Commercially-available and prototype technologies were developed, tested, and evaluated. Full-scale, monitored field tests were conducted over solstice-to-solstice periods to thoroughly evaluate the technologies, uncover potential risks associated with an unknown, and quantify performance benefits. Exterior shading systems were found to yield net zero energy levels of performance in a sunny climate and significant reductions in summer peak demand. Automated interior shading systems were found to yield significant daylighting and comfort-related benefits.In support of an integrated design process, a PC-based commercial fenestration (COMFEN) software package, based on EnergyPlus, was developed that enables architects and engineers to quickly assess and compare the performance of innovative facade technologies in the early sketch or schematic design phase. This tool is publicly available for free and will continue to improve in terms of features and accuracy. Other work was conducted to develop simulation tools to model the performance of any arbitrary complex fenestration system such as common Venetian blinds, fabric roller shades as well as more exotic innovative facade systems such as optical louver systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High planting density induces the expression of GA3-oxidase in leaves and GA mediated stem elongation in bioenergy sorghum

Abstract The stems of bioenergy sorghum hybrids at harvest are > 4 m long, contain > 40 internodes and account for ~ 80% of harvested biomass. In this study, bioenergy sorghum hybrids were grown at four planting densities (~ 20,000 to 132,000 plants/ha) under field conditions for 60 days to investigate the impact shading has on stem growth and biomass accumulation. Increased planting density induced a > 2-fold increase in sorghum internode length and a ~ 22% decrease in stem diameter, a typical shade avoidance response. Shade-induced internode elongation was due to an increase in cell length and number of cells spanning the length of internodes. SbGA3ox2 (Sobic.003G045900), a gene encoding the last step in GA biosynthesis, was expressed ~ 20-fold higher in leaf collar tissue of developing phytomers in plants grown at high vs. low density. Application of GA3 to bioenergy sorghum increased plant height, stem internode length, cell length and the number of cells spanning internodes. Prior research showed that sorghum plants lacking phytochrome B, a key photoreceptor involved in shade signaling, accumulated more GA1 and displayed shade avoidance phenotypes. These results are consistent with the hypothesis that increasing planting density induces expression of GA3-oxidase in leaf collar tissue, increasing synthesis of GA that stimulates internode elongation.

09 BIOMASS FUELS↗

Vegetation clumping modulates global photosynthesis through adjusting canopy light environment

Abstract The spatial dispersion of photoelements within a vegetation canopy, quantified by the clumping index (CI), directly regulates the within‐canopy light environment and photosynthesis rate, but is not commonly implemented in terrestrial biosphere models to estimate the ecosystem carbon cycle. A few global CI products have been developed recently with remote sensing measurements, making it possible to examine the global impacts of CI. This study deployed CI in the radiative transfer scheme of the Community Land Model version 5 (CLM5) and used the revised CLM5 to quantitatively evaluate the extent to which CI can affect canopy absorbed radiation and gross primary production (GPP), and for the first time, considering the uncertainty and seasonal variation of CI with multiple remote sensing products. Compared to the results without considering the CI impact, the revised CLM5 estimated that sunlit canopy absorbed up to 9%–15% and 23%–34% less direct and diffuse radiation, respectively, while shaded canopy absorbed 3%–18% more diffuse radiation across different biome types. The CI impacts on canopy light conditions included changes in canopy light absorption, and sunlit–shaded leaf area fraction related to nitrogen distribution and thus the maximum rate of Rubisco carboxylase activity ( V cmax ), which together decreased photosynthesis in sunlit canopy by 5.9–7.2 PgC year −1 while enhanced photosynthesis by 6.9–8.2 PgC year −1 in shaded canopy. With higher light use efficiency of shaded leaves, shaded canopy increased photosynthesis compensated and exceeded the lost photosynthesis in sunlit canopy, resulting in 1.0 ± 0.12 PgC year −1 net increase in GPP. The uncertainty of GPP due to the different input CI datasets was much larger than that caused by CI seasonal variations, and was up to 50% of the magnitude of GPP interannual variations in the tropical regions. This study highlights the necessity of considering the impacts of CI and its uncertainty in terrestrial biosphere models.

59 BASIC BIOLOGICAL SCIENCES↗

Scale model testing of drogues for free drifting buoys

Instrumented model drogue tests were conducted in a ship model towing tank. The purpose of the tests was to observe and measure deployment and drag characteristics of such shapes as parachutes, crossed vanes, and window shades which may be employed in conjunction with free drifting buoys. Both Froude and Reynolds scaling laws were applied while scaling to full scale relative velocities of from 0 to 0.2 knots. A weighted window shade drogue is recommended because of its performance, high drag coefficient, simplicity, and low cost. Detailed theoretical performance curves are presented for parachutes, crossed vanes, and window shade drogues. Theoretical estimates of depth locking accuracy and buoy-induced dynamic loads pertinent to window shade drogues are presented as a design aid. An example of a window shade drogue design is presented.

Vachon, W. A.↗

Aircraft geometry verification with enhanced computer generated displays

A method for visual verification of aerodynamic geometries using computer generated, color shaded images is described. The mathematical models representing aircraft geometries are created for use in theoretical aerodynamic analyses and in computer aided manufacturing. The aerodynamic shapes are defined using parametric bi-cubic splined patches. This mathematical representation is then used as input to an algorithm that generates a color shaded image of the geometry. A discussion of the techniques used in the mathematical representation of the geometry and in the rendering of the color shaded display is presented. The results include examples of color shaded displays, which are contrasted with wire frame type displays. The examples also show the use of mapped surface pressures in terms of color shaded images of V/STOL fighter/attack aircraft and advanced turboprop aircraft.

Cozzolongo, J. V.↗

Aircraft geometry verification with enhanced computer-generated displays

A method for visual verification of aerodynamic geometries using computer-generated, color-shaded images is described. The mathematical models representing aircraft geometries are created for use in theoretical aerodynamic analyses and in computer-aided manufacturing. The aerodynamic shapes are defined using parametric bi-cubic splined patches. This mathematical representation is then used as input to an algorithm that generates a color-shaded image of the geometry. A discussion of the techniques used in the mathematical representation of the geometry and in the rendering of the color-shaded display is presented. The results include examples of color-shaded displays, which are contrasted with wire-frame-type displays. The examples also show the use of mapped surface pressures in terms of color-shaded images of V/STOL fighter/attack aircraft and advanced turboprop aircraft.

Cozzolongo, J. V.↗

Sun shield

A shading device which is capable of compactly storing a flexible shade on a biased, window shade type spring roller is disclosed. It is controlled to deliver the shade selectively to either its operative shading or compact storage orientation.

Frank, Arthur M.↗

The least-squares mixing models to generate fraction images derived from remote sensing multispectral data

Constrained-least-squares and weighted-least-squares mixing models for generating fraction images derived from remote sensing multispectral data are presented. An experiment considering three components within the pixels-eucalyptus, soil (understory), and shade-was performed. The generated fraction images for shade (shade image) derived from these two methods were compared by considering the performance and computer time. The derived shade images are related to the observed variation in forest structure, i.e., the fraction of inferred shade in the pixel is related to different eucalyptus ages.

Shimabukuro, Yosio Edemir↗

Investigation of lunar base thermal control system options

Long duration human exploration missions to the Moon will require active thermal control systems which have not previously been used in space. The two technologies which are most promising for long term lunar base thermal control are heat pumps and radiator shades. Recent trade-off studies at the Johnson Space Center have focused development efforts on the most promising heat pump and radiator shade technologies. Since these technologies are in the early stages of development and many parameters used in the study are not well defined, a parametric study was done to test the sensitivity to each assumption. The primary comparison factor in these studies was the total mass system, with power requirements included in the form of a mass penalty for power. Heat pump technologies considered were thermally driven heat pumps such as metal hydride, complex compound, absorption and zeolite. Also considered were electrically driven Stirling and vapor compression heat pumps. Radiator shade concepts considered included step shaped, V-shaped and parabolic (or catenary) shades and ground covers. A further trade study compared the masses of heat pump and radiator shade systems.

Ewart, Michael K.↗

Discomfort glare with complex fenestration systems and the impact on energy use when using daylighting control

Glare is a frequent issue in highly glazed buildings. A modelling approach is presented that uses discomfort glare probability and discomfort glare index as metrics to determine occupants’ behaviour. A glare control algorithm that actuated an interior shade for glare protection based on the predicted perception was implemented in a building simulation program. A reference case with a state-of-the-art base glazing was compared to the same glazing but with five different complex fenestration systems, i.e., exterior shades. The windows with exterior shades showed significant variations in glare frequencies. Energy use intensity in a prototypical office building with daylighting controls was greatly influenced for the systems with frequent glare occurrence. While the base glazing could benefit from glare control, some of the exterior shades showed significantly greater energy use when discomfort glare-based operation of interior shades was considered.

Hoffmann, Sabine↗

On the Ambiguity of Using Isc for Analyzing Suns-Voc Data on Modules

In standard silicon solar modules, cells are strung in series with bypass diodes incorporated to reduce the effects of shading. When all of the strings are partially shaded the measured short circuit current is affected and the Isc of the module will be equal to that of the lowest current cell in the least shadowed string. In bifacial modules the ability to assess losses due to shading is especially important. This paper advocates an alternative approach to converting the raw suns-voc data to pseudo IV data in modules where shading may be affecting the suns-voc curve results.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗

Performance Modeling and Testing of Distributed Electronics in PV Systems; NREL (National Renewable Energy Laboratory)

Computer modeling is able to predict the performance of distributed power electronics (microinverters, power optimizers) in PV systems. However, details about partial shade and other mismatch must be known in order to give the model accurate information to go on. This talk will describe recent updates in NREL’s System Advisor Model program to model partial shading losses with and without distributed power electronics, along with experimental validation results. Computer modeling is able to predict the performance of distributed power electronics (microinverters, power optimizers) in PV systems. However, details about partial shade and other mismatch must be known in order to give the model accurate information to go on. This talk will describe recent updates in NREL’s System Advisor Model program to model partial shading losses.

14 SOLAR ENERGY↗

Tropical Forest Soil Microbiome Modulates Leaf Heat Tolerance More Strongly Under Warming Than Ambient Conditions

ABSTRACT It is unclear how plants respond to increasing temperatures. Leaf heat tolerance (LHT) is often at its upper limit in tropical forests, suggesting that climate change might negatively impact these forests. We hypothesized that intraspecific variation in LHT might be associated with changes in the soil microbiome, which might also respond to climate. We hypothesized that warming would increase LHT through changes in the soil microbiome: we combined an in situ tropical warming experiment with a shade house experiment in Puerto Rico. The shade house experiment consisted of growing seedlings of Guarea guidonia , a dominant forest species, under different soil microbiome treatments (reduced arbuscular mycorrhizal fungi, reduced plant pathogens, reduced microbes, and unaltered) and soil inoculum from the field experiment. Heat tolerance was determined using chlorophyll fluorescence ( F V /F m ) on individual seedlings in the field and on groups of seedlings (per pot) in the shade house. We sequenced soil fungal DNA to analyze the impacts of the treatments on the soil microbiome. In the field, seedlings from ambient temperature plots showed higher F V /F m values under high temperatures (0.648 at 46°C and 0.067 at 52°C) than seedlings from the warming plots (0.535 at 46°C and 0.031 at 52°C). In the shade house, the soil microbiome treatments significantly influenced the fungal community composition and LHT ( T crit and F V /F m ). Reduction in fungal pathogen abundance and diversity altered F V /F m before T 50 for seedlings grown with soil inoculum from the warming plots but after T 50 for seedlings grown with soil inoculum from the ambient plots. Our findings emphasize that the soil microbiome plays an important role in modulating the impacts of climate change on plants. Understanding and harnessing this relationship might be vital for mitigating the effects of warming on forests, emphasizing the need for further research on microbial responses to climate change.

Hernandes Villani, Gabriela [Department of Plant B↗

Overshadow PLC to Detect Remote Control-Logic Injection Attacks

Programmable logic controllers (PLCs) in industrial control systems (ICS) are vulnerable to remote control logic injection attacks. Attackers target the control logic of a PLC to manipulate the behavior of a physical process such as nuclear plants, power grids, and gas pipelines. Control logic attacks have been studied extensively in the literature, including hiding the transfer of a control logic over the network from both packet header-based signatures, and deep packet inspection. For instance, these attacks transfer a control logic code as data, into small fragments (one-byte per packet), that are further padded with noise data. To detect control logic in ICS network traffic, this paper presents Shade, a novel shadow memory technique that observes the network traffic to maintain a local copy of the current state of a PLC memory. To analyze the memory contents, Shade employs a classification algorithm with 42 unique features categorized into five types at different semantic levels of a control logic code, such as number of rungs, number of consecutive decompiled instructions, and n-grams. We then evaluate Shade against control logic injection attacks on two PLCs, Modicon M221 and MicroLogix 1400 from two ICS vendors, Schneider electric and Allen-Bradley, respectively. The evaluation results show that Shade can detect an attack instance (i.e., identifying at least one attack packet during the transfer of a malicious control logic) accurately without any false alarms.

Yoo, Hyunguk↗

Rethinking agrivoltaic incentive programs: A science-based approach to encourage practical design solutions

Agrivoltaic systems are promising solutions to address global food and energy challenges by combining agriculture and solar photovoltaics. However, the lack of appropriate regulations to define and guide their implementation constrains the growth of agrivoltaic systems in the U.S. This study uses a shading and radiation tool to evaluate an existing agrivoltaic incentive program that defines agrivoltaic designs based on shading reduction limits and panel height requirements. Our analysis indicates that structuring policy requirements around shading, and not light availability, may lead to an underestimation of crop suitability by neglecting diffuse radiation. Furthermore, we show that agrivoltaic systems can avoid increasing panel height if policy acknowledges use-case scenarios where farming only occurs between rows. In light of these insights, this study proposes two key policy recommendations: (1) benchmark crop suitability based on daily light integral (DLI) requirements for a shade-intolerant crop selected to represent a prevalent crop in the region, and (2) include an incentive scenario where agriculture is only required between rows. Furthermore, these two recommendations can potentially incentivize designs that are practical and closer in cost to conventional solar farms, thereby accelerating the adoption of cost-effective agrivoltaic systems.

14 SOLAR ENERGY↗