Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Cloud Influence on ERA5 and AMPS Surface Downwelling Longwave Radiation Biases in West Antarctica

The surface downwelling longwave radiation component (LW[down arrow]) is crucial for the determination of the surface energy budget and has significant implications for the resilience of ice surfaces in the polar regions. Accurate model evaluation of this radiation component requires knowledge about the phase, vertical distribution, and associated temperature of water in the atmosphere, all of which control the LW[down arrow] signal measured at the surface. In this study, we examine the LW[down arrow] model errors found in the Antarctic Mesoscale Prediction System (AMPS) operational forecast model and the ERA5 reanalysis model relative to observations from the AWARE campaign at McMurdo Station and the West Antarctic Ice Sheet (WAIS) Divide. The errors are calculated separately for observed clear-sky conditions, ice-cloud occurrences, and liquid-bearing cloud layer (LBCL) occurrences. The analysis results show a tendency in both models at each site to underestimate the LW[down arrow] during clear sky conditions, high error variability (standard deviations > 20 W/m[exp2]) during any type of cloud occurrence, and negative LW biases when LBCLs are observed (bias magnitudes > 15 W/m[exp2] in tenuous LBCL cases; > 43 W/m[exp2] in optically thick/opaque LBCLs instances). We suggest that a generally dry and liquid-deficient atmosphere responsible for the identified LW[down arrow] biases in both models is the result of excessive ice formation and growth, which could stem from model initial and lateral boundary conditions, microphysics scheme, aerosol representation, and/or limited vertical resolution.

Israel Silber↗

SMAP Validation Experiment 2019-2020 (SMAPVEX19/20): Detection of Soil Moisture Under Forest Canopy

The retrieval of soil moisture under forest canopy has long been an important goal for low frequency remote sensing. The NASA mission started a dedicated field experiment in May 2019 by deploying two temporary soil moisture networks in northeast US that cover two separate SMAP pixels with variable degree of forest cover. The measurements will run through 2020 and they will be augmented with two intensive observation periods (IOP). The first IOP will be conducted in June-July 2020 and the other one in October 2020. The IOPs will see deployment of the airborne PALS (Passive Active L-band sensor) instrument, which is similar to the SMAP instrument, and intensive manual measurements of soil moisture and vegetation. The measurements also include tower-based radiometer observations with ground truth measurements within the instrument footprint. The early results have shown that the SMAP measurement signal at L-band is sensitive to soil moisture changes observed on the ground.

Andreas Colliander↗

Performance Assessments of the SNPP and N20 VIIRS DNB Using Observations of Bright Stars

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the Suomi-NPP (SNPP) and NOAA-20 (N20) spacecrafts is a multi-spectral Earth-observing instrument with spectral channels ranging from the visible to the long-wave infrared. In addition to these spectral channels, the VIIRS instrument features a panchromatic Day/Night band (DNB) with 3 gain stages (low, mid, and high) which allows for Earth-view (EV) radiance retrievals over 7 orders of magnitude. The DNB is able to collect data ranging from dim city lights during nighttime up to reflected sunlight from cloud-tops during daytime. The DNB data collection is divided into 32 aggregation modes, where sub-pixel aggregation is used to maintain a nearly constant pixel footprint on ground during EV data collection throughout each scan. The DNB is also sensitive enough to observe bright stars through the instrument space-view (SV) port. Data from these bright stars can be used to track the temporal stability of the sensor gain and as a method of intercomparison between the two VIIRS instruments. In this work, we will present several sensor performance assessments of the VIIRS DNB using stars. In addition to the sensor gain trending, these assessments will include a comparison of the differences between the daytime and nighttime data due to the effects of stray-light, a comparison of the measured signal as a function of aggregation mode, a comparison between the two high-gain sub-stages, and half-angle mirror side for both the SNPP and N20 VIIRS DNB.

VIIRS↗

Design and Modeling of a Coded-Interleaving System in the Presence of Fading

Future deep space links are migrating towards higher frequency bands such as Ka band and optical. These links are susceptible to non linear effects (e.g. cloud coverage, atmospheric turbulence, scintillation, antenna mis-pointing, jitter, relative motion, etc.) that cause various degrees of fading loss over various time scales. We consider a channel experiencing block fading where the channel coherence time is a lot longer than the length of a codeword. As long as the fading duration is not excessive, an interleaver can be used in a coded-communication system that randomizes the fades among symbols of multiple codewords. This achieves an “averaging” effect that spreads the signal energy more evenly among the codewords, and improves the likelihood that each of them can be decoded correctly. For simplicity, we consider a block interleaver where adjacent symbols of a codeword have a fixed delay (or separation) with each other, and investigate the error-rate performance of a coded-interleaving system (with fixed and finite interleaving depth) in the presence of block fading. Unlike prior research which assumes theoretical channel coherence models, we aim to build upon our analysis using empirical spacecraft signal measurements obtained with the Deep Space Network, and to use the fundamental theories of probability and statistics (e.g. variations of Law of Large Numbers) to quantify the error-rate performance of the coded-interleaving system. We propose to utilize these results in the design of a two-dimensional coded-interleaving system for fading channels.

Sanchez-Net, Marc↗

SMAP Validation Experiment 2019-2021 (SMAPVEX19-21): Detection of Soil Moisture Under Temperate Forest Canopy

The retrieval of soil moisture under forest canopy has long been an important goal for low frequency remote sensing. The NASA mission started a dedicated field experiment in May 2019 by deploying two temporary soil moisture networks in northeast US that cover two separate SMAP pixels with variable degree of forest cover. The measurements will be augmented with two intensive observation periods (IOP). The first IOP is planned for July and the other one for October. The IOPs will see deployment of the airborne PALS (Passive Active L-band sensor) instrument, which is similar to the SMAP instrument, and intensive manual measurements of soil moisture and vegetation. The measurements also include tower-based radiometer observations with ground truth measurements within the instrument footprint. The early results have shown that the SMAP measurement signal at L-band is sensitive to soil moisture changes observed on the ground.

Yueh, Simon H.↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Using "AI Poincare" to analyze non-linear integrable optics

This study dives into the applicability of using automated discovery of conserved quantities in dynamical systems relevant to accelerator physics. Specifically, we explore the performance of AI Poincaré in analyzing numerical trajectory data obtained using the McMillan system of non-linear integrable optics. A comprehensive evaluation of the algorithm's performance is conducted through diverse methodologies. These include the analysis of the estimated number of conserved quantities embedded in a dataset and the deviation of interpolated points on the inferred manifold with respect to points in actually in the dataset. the investigation identifies an optimal range of perturbation distances where the underlying manifold extraction algorithm inside AI Poincaré exhibits optimal performance. Additionally, an improved neural network architecture is proposed based on the observed results. Finally, we apply the algorithm to preliminary experimental data from the Integrable Optics Test Accelerator at Fermilab to successfully infer the number of conserved quantities even in the presence of fast decoherence of the measured signal.

Osmanov, Lazare [Free U. Tbilisi]↗

Application of small-signal modeling and measurement techniques to the stability analysis of an integrated switching-mode power system

Small-signal modeling techniques are used in a system stability analysis of a breadboard version of a complete functional electrical power system. The system consists of a regulated switching dc-to-dc converter, a solar-cell-array simulator, a solar-array EMI filter, battery chargers and linear shunt regulators. Loss mechanisms in the converter power stage, including switching-time effects in the semiconductor elements, are incorporated into the modeling procedure to provide an accurate representation of the system without requiring frequency-domain measurements to determine the damping factor. The small-signal system model is validated by the use of special measurement techniques which are adapted to the poor signal-to-noise ratio encountered in switching-mode systems. The complete electrical power system with the solar-array EMI filter is shown to be stable over the intended range of operation.

Wong, R. C.↗

Integrator for on-line measurement of buffet signals

Device determines average rms value of buffet signals by integrating rms signals from strain gages for preselected period of time. System measures average rms value of other transient data, and the upper frequency limit depends on the frequency response of the amplifiers.

Batts, C. N.↗

Signal to noise measurement circuit

Phase lock reference provides a rapid and accurate method of determining the signal-to-noise ratio at the intermediate frequency stage of a receiver.

Deerkoski, L. F.↗

Cold plasma diagnostics using satellite measurements of VLF signals from ground transmitters

A diagnostic technique to obtain the cold-plasma density profile in the magnetosphere is introduced. This method uses satellite measurements of group delay and pulse duration of VLF signals from ground transmitters in conjunction with a detailed ray-tracing analysis. An iterative method is involved which starts with an approximate density profile, computes the ray paths for that profile, and then compares the properties of the rays that reach the satellite location with the actual satellite measurements. The density profile is then modified to account for any discrepancies between the two results. The same process is repeated with the new profile until one has reasonable agreement between the data and ray-tracing results. This method is applied to the case of an Imp 6 pass, where strong signals from the Siple VLF transmitter were observed for over 25 min. Good agreement is found between the results of the proposed technique and the well-known ground whistler techniques of cold-plasma diagnostics. The results also serve to illustrate the wide diversity of propagation paths from ground transmitters to high-altitude satellites during VLF wave-injection experiments.

Inan, U. S.↗

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.↗

Signal-Induced Noise Effects in a Photon Counting System for Stratospheric Ozone Measurement

Signal-induced noise (SIN) is a common effect resulting when a photomultiplier tube (PMT) is saturated, for a brief moment, with a high intensity light pulse. After the laser pulse is sent into the atmosphere a very large light return, from either the near-field or a cloud, causes the PMT to momentarily saturate. The PMT is gated off at this time so no signal is seen at the anode. When the PMT gate is turned on, the far-field light return from the atmosphere is observed. This signal is distorted, however because of the addition of SIN to the received light signal causing a slower than expected decay of the atmospheric signal return. We have characterized SIN responses to varying parameters of the incident light on the PMT. These varied parameters included incident wavelength, PMT voltage, incident intensity, and tube type. We found that only the amplitude of the SIN was effected by varying PMT voltages and light intensities. The amplitude increased linearly as input light intensity increased. Different incident wavelengths at the same intensity did not effect the amplitude or the temporal behavior of the SIN response. Finally, different PMT tubes with similar physical structures exhibited similar SIN responses although with different amplitudes. The different amplitudes can be attributed to the different gains and operating voltages of each tube. These results suggest that SIN is caused by photocathode electron dynamics such as charge accumulation on internal PMT surfaces. These surfaces then emit the electrons slowly resulting in a long decay noise signal. With the SIN responses characterized we can now try to develop a method to reduce or eliminate SIN in DIAL systems.

Harper, David B.↗

High-intensity sound in air saturated fibrous bulk porous materials

The interaction high-intensity sound with bulk porous materials in porous materials including Kevlar 29 is reported. The nonlinear behavior of the materials was described by dc flow resistivity tests. Then acoustic propagation and reflection were measured and small signal broadband measurements of phase speed and attenuation were carried out. High-intensity tests were made with 1, 2, and 3 kHz tone bursts to measure harmonic generation and extra attenuation of the fundamental. Small signal standing wave tests measured impedence between 0.1 and 3.5 kHz. High level tests with single cycle tone bursts at 1 to 4 kHz show that impedance increases with intensity. A theoretical analysis is presented for high-porosity, rigid-frame, isothermal materials. One dimensional equations of motion are derived and solved by perturbation. The experiments show that there is excess attenuation of the fundamental component and in some cases a close approach to saturation. A separate theoretical model, developed to explain the excess attenuation, yields predictions that are in good agreement with the measurements. Impedance and attenuation at high intensities are modeled.

Kuntz, H. L., II↗

Characterizing the Effects of Two Ground-based Outdoor Microphone Configurations

Multiple International and Federal regulations stipulate the acquisition of aircraft noise shall be conducted using inverted pressure microphones over a round ground board. These ground boards are used to provide an acoustically hard reflecting surface, limiting the effects of the potentially absorptive ground local to the test location. The microphone location is also specified to be offset from the center of the board to limit the effects of acoustic diffraction off the board edge. In order to determine the effects of the ground board on the measured acoustic signal, a comprehensive measurement campaign was undertaken at NASA Langley Research Center. The experimental setup included multiple ground board configurations placed on top of a sand pit, in an otherwise anechoic chamber. Ground board configurations included a microphone inverted and offset over the round ground board and a microphone offset and flush mounted in the ground board.White noise was then used to investigate the ground board effects on the recorded signal. Normal impedance measurements were also acquired to determine the reflection coefficients of the sand and ground boards. Experimental results are discussed, along with implications for future research and development.Results indicate that both microphone configurations perform adequately up to 10 kHz. When the ground substrate is a soft material and the sound comes in at angles near grazing incidence the sound energy is attenuated above 1 kHz. Additionally, the plastic material used to construct the ground boards was found to be acoustically hard between 0.1 –3.0 kHz, and likely extending to higher frequencies.

Mark C. Anderson↗

A Comparison of Signal Enhancement Methods for Extracting Tonal Acoustic Signals

The measurement of pure tone acoustic pressure signals in the presence of masking noise, often generated by mean flow, is a continual problem in the field of passive liner duct acoustics research. In support of the Advanced Subsonic Technology Noise Reduction Program, methods were investigated for conducting measurements of advanced duct liner concepts in harsh, aeroacoustic environments. This report presents the results of a comparison study of three signal extraction methods for acquiring quality acoustic pressure measurements in the presence of broadband noise (used to simulate the effects of mean flow). The performance of each method was compared to a baseline measurement of a pure tone acoustic pressure 3 dB above a uniform, broadband noise background.

Jones, Michael G.↗