Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL STABILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Pulsar Movement Animation and its Corresponding Signal Visualization for Timing Source

The global positioning system, widely used for synchronization in energy systems, faces vulnerabilities, while Pulsars—natural cosmic clocks—offer long-term stability as potential backup timing sources. Existing research lacks sufficient exploration of Pulsar signal animation under astrophysical factors, limiting practical applications. This study establishes a mathematical model based on the rotation dynamics of dual-beam Pulsars and implements dynamic signal visualization through MATLAB. The model dynamically illustrates the relative motion between Pulsar beams and observers via timeline calculations, beam intensity modeling, and rotation matrix derivation. A case study on the millisecond Pulsar J1939+2134 reveals that observer angles influence signal peak timing, while beam widths determine signal duration, highlighting the critical role of parameter calibration for timing accuracy. Open-source code and animation results are publicly shared, providing tools for interdisciplinary research. This study validates the feasibility of Pulsar-based timing in energy systems, offering new insights to enhance synchronization robustness.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

A computer-aided telescope pointing system utilizing a video star tracker

The Video Inertial Pointing (VIP) System developed to satisfy the acquisition and pointing requirements of astronomical telescopes is described. A unique feature of the system is the use of a single sensor to provide information for the generation of three axis pointing error signals and for a cathode ray tube (CRT) display of the star field. The pointing error signals are used to update the telescope's gyro stabilization and the CRT display is used by an operator to facilitate target acquisition and to aid in manual positioning of the telescope optical axis. A model of the system using a low light level vidicon built and flown on a balloon-borne infrared telescope is briefly described from a state of the art charge coupled device (CCD) sensor. The advanced system hardware is described and an analysis of the multi-star tracking and three axis error signal generation, along with an analysis and design of the gyro update filter, are presented. Results of a hybrid simulation are described in which the advanced VIP system hardware is driven by a digital simulation of the star field/CCD sensor and an analog simulation of the telescope and gyro stabilization dynamics.

Murphy, J. P.↗

Intensity-Modulated Continuous-Wave Laser Absorption Spectrometer at 1.57 Micrometer for Atmospheric CO2 Measurements

Understanding the earth's carbon cycle is essential for diagnosing current and predicting future climates, which requires precise global measurements of atmospheric CO2 through space missions. The Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission will provide accurate global atmospheric CO2 measurements to meet carbon science requirements. The joint team of NASA Langley Research Center and ITT Exelis, Inc. proposes to use the intensity-modulated, continuous-wave (IM-CW) laser absorption spectrometer (LAS) approach for the ASCENDS mission. Prototype LAS instruments have been developed and used to demonstrate the power, signal-to-noise ratio, precision and accuracy, spectral purity, and stability of the measurement and the instrument needed for atmospheric CO2 observations from space. The ranging capability from laser platform to ground surfaces or intermediate backscatter layers is achieved by transmitted range-encoded IM laser signals. Based on the prototype instruments and current lidar technologies, space LAS systems and their CO2 column measurements are analyzed. These studies exhibit a great potential of using IM-CW LAS system for the active space CO2 mission ASCENDS.

Lin, Bing↗

Intensity-Modulated Continuous-Wave Lidar at 1.57 Micrometer for Atmospheric CO2 Measurements

Understanding the earth's carbon cycle is essential for diagnosing current and predicting future climates, which requires precise global measurements of atmospheric CO2 through space missions. The Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission will provide accurate global atmospheric CO2 measurements to meet carbon science requirements. The joint team of NASA Langley Research Center and ITT Exelis, Inc proposes to use the intensity-modulated, continuous-wave (IM-CW) lidar approach for the ASCENDS mission. Prototype instruments have been developed and used to demonstrate the power, signal-to-noise ratio, precision and accuracy, spectral purity, and stability of the measurement and the instrument needed for atmospheric CO2 observations from space. The ranging capability from laser platform to ground surfaces or intermediate backscatter layers is achieved by transmitted range-encoded IM laser signals. Based on the prototype instruments and current lidar technologies, space lidar systems and their CO2 column measurements are analyzed. These studies exhibit a great potential of using IM-CW lidar system for the active space CO2 mission ASCENDS.

Lin, Bing↗

Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

calibrating↗

Applying Linear Optics from Closed Orbits Modulation for finding beam-based alignment of harmonic sextupoles

A fast and accurate beam-based alignment (BBA) method for harmonic sextupoles has been devel oped at NSLS-II using Linear Optics from Closed Orbit Modulation (LOCOM). The approach excites the beam with simultaneous sine-wave signals at two fast correctors, chosen with an appropriate phase advance to span the full betatron phase space. This strategy suppresses systematic errors from hysteresis, while additional errors from orbit drift and power-supply calibration are minimized by the short measurement time (a few minutes) and reliance solely on beam-based current-to-field conver sion of the sextupoles, with hysteresis explicitly included. Simulations indicate that Linear Optics from Closed Orbits (LOCO) combined with 0.5 mm local orbit bumps can resolve relative sextupole field offsets (∆k₂) with precision better than 10% of k₂, reflecting to beam-based alignment (BBA) accuracy finer than 50 µm. Moreover, employing machine-learning-optimized local orbit bumps en hances sextupole-induced quadrupole signals in a deterministic manner and maintains orbit stability under large sextupole strength variations (±40%). The proposed method is experimentally validated through proof-of-principle measurements at NSLS-II, demonstrating its potential as a fast, precise, and robust tool for harmonic sextupole alignment.

43 PARTICLE ACCELERATORS↗

Photomultiplier tube development for the 1.06 micrometer wavelength

High speed, electrostatic photomultipliers were developed for use in 400 megabit laser communication systems operating at the 1.06 micron wavelength. A high performance, electrostatic III-V photocathode PMT was shown in communication system tests to perform competitively with solid state and avalanche photodiodes. Signal-induced noise and III-V cathode stability were identified as remaining technical problems while cathode quantum efficiencies of or = 5% at 1.06 micron and 320 picosecond rise and fall time pulse performance were achieved.

Enck, R. S., Jr.↗

Thermal compensator for helium refrigerators

Closed-cycle helium refrigerator sensor generates negative-feedback control signals that drive heating diode to maintain temperature stability. Temperature-sensing diode and heating diode are mounted on heat sink that provides conductive path between load and cold tip. Method is applicable to other temperature-control applications, such as laser equipment, electronic instruments, and computer systems.

Hillman, J. J.↗

The scanning modulation collimator experiment on the HEAO-1

The purpose of this experiment is to localize celestial sources of X-rays to a precision of 5 to 20 arcsec, so that they may be identified with optical or radio counterparts. We also study their angular size and structure, to elucidate the X-ray emission mechanism. Four grids, wound with nickel alloy wires, are aligned to produce a modulated X-ray signal when the spacecraft rotation carries the collimator field of view across an X-ray source. An image dissector star camera and rate integrating gyroscopes are used to deduce the celestial position from which a peak X-ray signal arises. On-orbit performance and thermal stability have been very good. Based on the first six weeks of quick look data, we have the following results: the location of an X-ray burst source within a globular cluster; the location of 4U1608-52, a unique object which shows bursting, transient, and steady X-ray behavior and is also an optical source; the location of the X-ray transient H1705-25, which provided Anglo-Australian astronomers the basis for an optical identification with a nova-like object; the location of the X-ray transient H1743-32 in the galactic center; and a precise measurement of the angular extent of the Crab Nebula.

Schwartz, D. A.↗

Control means for a gas turbine engine

A means is provided for developing a signal representative of the actual compressor casing temperature, a second signal representative of compressor inlet gas temperature, and a third signal representative of compressor speed. Another means is provided for receiving the gas temperature and compressor speed signals and developing a schedule output signal which is a representative of a reference casing temperature at which a predetermined compressor blade stabilized clearance is provided. A means is also provided for comparing the actual compressor casing temperature signal and the reference casing temperature signal and developing a clearance control system representative of the difference. The clearance control signal is coupled to a control valve which controls a flow of air to the compressor casing to control the clearance between the compressor blades and the compressor casing. The clearance control signal can be modified to accommodate transient characteristics. Other embodiments are disclosed.

Beitler, R. S.↗

Nonlinear Dynamic Compensation For Feedback Control

Nonlinear dynamic compensation scheme enhances stability of feedback control system in which feedback signal includes quantization noise. Compensator slows response of control system at low error signals to diminish effect of quantization noise but provides faster response at large error signals to speed correction of large errors.

Lin, Yu-Hwan↗

Ultrastable Multigigahertz Photonic Oscillator

Novel photonic oscillator developed to serve as ultrastable source of microwave and millimeter-wave signals. In system, oscillations generated photonically, then converted to electronic form. Includes self-mode-locked semiconductor laser producing stream of pulses, detected and fed back to laser as input. System also includes fiber-optic-delay-line discriminator, which detects fluctuations of self-mode-locking frequency and generates error signal used in negative-feedback loop to stabilize pulse-repetition frequency.

Logan, Ronald T., Jr.↗

Resolution of sensory ambiguities for gaze stabilization requires a second neural integrator

The ability to simultaneously move in the world and maintain stable visual perception depends critically on the contribution of vestibulo-ocular reflexes (VORs) to gaze stabilization. It is traditionally believed that semicircular canal signals drive compensatory responses to rotational head disturbances (rotational VOR), whereas otolith signals compensate for translational movements [translational VOR (TVOR)]. However, a sensory ambiguity exists because otolith afferents are activated similarly during head translations and reorientations relative to gravity (i.e., tilts). Extra-otolith cues are, therefore, necessary to ensure that dynamic head tilts do not elicit a TVOR. To investigate how extra-otolith signals contribute, we characterized the temporal and viewing distance-dependent properties of a TVOR elicited in the absence of a lateral acceleration stimulus to the otoliths during combined translational/rotational motion. We show that, in addition to otolith signals, angular head position signals derived by integrating sensory canal information drive the TVOR. A physiological basis for these results is proposed in a model with two distinct integration steps. Upstream of the well known oculomotor velocity-to-position neural integrator, the model incorporates a separate integration element that could represent the "velocity storage integrator," whose functional role in the oculomotor system has so far remained controversial. We propose that a key functional purpose of the velocity storage network is to temporally integrate semicircular canal signals, so that they may be used to extract translation information from ambiguous otolith afferent signals in the natural and functionally relevant bandwidth of head movements.

Non-NASA Center↗

Assessment of Current Estimates of Global and Regional Mean Sea Level from the TOPEX/Poseidon, Jason-1, and OSTM 17-Year Record

The science value of satellite altimeter observations has grown dramatically over time as enabling models and technologies have increased the value of data acquired on both past and present missions. With the prospect of an observational time series extending into several decades from TOPEX/Poseidon through Jason-1 and the Ocean Surface Topography Mission (OSTM), and further in time with a future set of operational altimeters, researchers are pushing the bounds of current technology and modeling capability in order to monitor global sea level rate at an accuracy of a few tenths of a mm/yr. The measurement of mean sea-level change from satellite altimetry requires an extreme stability of the altimeter measurement system since the signal being measured is at the level of a few mm/yr. This means that the orbit and reference frame within which the altimeter measurements are situated, and the associated altimeter corrections, must be stable and accurate enough to permit a robust MSL estimate. Foremost, orbit quality and consistency are critical to satellite altimeter measurement accuracy. The orbit defines the altimeter reference frame, and orbit error directly affects the altimeter measurement. Orbit error remains a major component in the error budget of all past and present altimeter missions. For example, inconsistencies in the International Terrestrial Reference Frame (ITRF) used to produce the precision orbits at different times cause systematic inconsistencies to appear in the multimission time-frame between TOPEX and Jason-1, and can affect the intermission calibration of these data. In an effort to adhere to cross mission consistency, we have generated the full time series of orbits for TOPEX/Poseidon (TP), Jason-1, and OSTM based on recent improvements in the satellite force models, reference systems, and modeling strategies. The recent release of the entire revised Jason-1 Geophysical Data Records, and recalibration of the microwave radiometer correction also require the further re-examination of inter-mission consistency issues. Here we present an assessment of these recent improvements to the accuracy of the 17 -year sea surface height time series, and evaluate the subsequent impact on global and regional mean sea level estimates.

Beckley, Brian D.↗

The Geostationary Fourier Transform Spectrometer

The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for an earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. The GeoFTS instrument is a half meter cube size instrument designed to operate in geostationary orbit as a secondary "hosted" payload on a commercial geostationary satellite mission. The advantage of GEO is the ability to continuously stare at a region of the earth, enabling frequent sampling to capture the diurnal variability of biogenic fluxes and anthropogenic emissions from city to continental scales. The science goal is to obtain a process-based understanding of the carbon cycle from simultaneous high spatial resolution measurements of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) many times per day in the near infrared spectral region to capture their spatial and temporal variations on diurnal, synoptic, seasonal and interannual time scales. The GeoFTS instrument is based on a Michelson interferometer design with a number of advanced features incorporated. Two of the most important advanced features are the focal plane arrays and the optical path difference mechanism. A breadboard GeoFTS instrument has demonstrated functionality for simultaneous measurements in the visible and IR in the laboratory and subsequently in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson overlooking the Los Angeles basin. A GeoFTS engineering model instrument is being developed which will make simultaneous visible and IR measurements under space flight like environmental conditions (thermal-vacuum at 180 K). This will demonstrate critical instrument capabilities such as optical alignment stability, interferometer modulation efficiency, and high throughput FPA signal processing. This will reduce flight instrument development risk and show that the GeoFTS design is mature and flight ready.

Carbon exchanges↗

Fiber-Optic Frequency-Transfer Link

System for distribution of 100-MHz reference signal features transmission through optical fiber to station 22 km away and stabilization of frequency by radio frequency phase-conjugation method. Compensates for variations in phase (caused mostly by changes in temperature along optical fiber) of signal arriving at remote station. Involves measurement and control of phases of transmitted and reflected signals at reference station to obtain reference phase at remote station.

Primas, L. E.↗

Device for determining relative angular position between a spacecraft and a radiation emitting celestial body

Signals indicative of the relative angular position between a spin stabilized spacecraft, probe, or sounding rocket and a radiation emitting celestial body are derived with a detector including four electrodes for deriving indications of the centroid of the radiation image on the detector. During each spin of the satellite each electrode derives a signal having a first non-zero level while the detector is not illuminated by the radiation, and a sound non-zero level while it is illuminated by the radiation.

Farthing, W. H.↗