Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL TO NOISE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Fast Eigen-based signal combining algorithms for large antenna arrays

A Large array of small antennas can be used to enhance signals with very low signal-to-noise ratio and can also be used to replace large apertures. In this paper, a fast combining algorithm is proposed and analyzed to maximize the combined output signal-to-noise ratio.

Eigen signal combining array↗

Design, fabrication and testing of a CFA for use in the solar power satellite

A crossed field amplifier was designed to meet the performance objectives of high signal to noise ratio, an efficiency of 85%, a CW microwave power output of 5-8 kW, and a frequency of 2450 MHz. The signal to noise ratio achieved was better than 69 db/MHz in a 2000 MHz band centered on the carrier. High circuit efficiency of 97% and a sharp knee on voltage current characteristic were achieved. The basic problem of maintaining good transfer of heat to the external radiator while providing for adequate connections to input and output was solved. Maximum efficiency achieved was 70.5% and gain and power level were below objectives. An investigation of causes of reduced performance indicated the poor field pattern in the cathode anode interaction area of the tube was a major cause.

Brown, W. C.↗

Effects of window size and shape on accuracy of subpixel centroid estimation of target images

A new algorithm is presented for increasing the accuracy of subpixel centroid estimation of (nearly) point target images in cases where the signal-to-noise ratio is low and the signal amplitude and shape vary from frame to frame. In the algorithm, the centroid is calculated over a data window that is matched in width to the image distribution. Fourier analysis is used to explain the dependency of the centroid estimate on the size of the data window, and simulation and experimental results are presented which demonstrate the effects of window size for two different noise models. The effects of window shape were also investigated for uniform and Gaussian-shaped windows. The new algorithm was developed to improve the dynamic range of a close-range photogrammetric tracking system that provides feedback for control of a large gap magnetic suspension system (LGMSS).

Welch, Sharon S.↗

Characterization and Analysis of InGaAsSb Detectors

Profiling of atmospheric CO2 at 2 micron wavelength using the LIDAR technique, has recently gained interest. Although several detectors might be suitable for this application, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the detector signal-to-noise ratio and minimizes the background signal, thereby increasing the device sensitivity and dynamic range. Detectors meeting the above idealized criteria are commercially unavailable for this particular wavelength. In this paper, the characterization and analysis of Sb-based detectors for 2 micron lidar applications are presented. The detectors were manufactured by AstroPower, Inc., with an InGaAsSb absorbing layer and AlGaAsSb passivating layer. The characterization experiments included spectral response, current versus voltage and noise measurements. The effect of the detectors bias voltage and temperature on its performance, have been investigated as well. The detectors peak responsivity is located at the 2 micron wavelength. Comparing three detector samples, an optimization of the spectral response around the 2 micron wavelength, through a narrower spectral period was observed. Increasing the detector bias voltage enhances the device gain at the narrow spectral range, while cooling the device reduces the cut-off wavelength and lowers its noise. Noise-equivalent-power analysis results in a value as low as 4 x 10(exp -12) W/Hz(exp 1/2) corresponding to D* of 1 x 10(exp 10) cmHz(exp 1/2)/W, at -1 V and 20 C. Discussions also include device operational physics and optimization guidelines, taking into account peculiarity of the Type II heterointerface and transport mechanisms under these conditions.

Abedin, M. Nurul↗

Unified and consistent structure growth measurements from joint ACT, SPT and \textit{Planck} CMB lensing

We present the tightest cosmic microwave background (CMB) lensing constraints to date on the growth of structure by combining CMB lensing measurements from the Atacama Cosmology Telescope (ACT), the South Pole Telescope (SPT) and \textit{Planck}. Each of these surveys individually provides lensing measurements with similarly high statistical power, achieving signal-to-noise ratios of approximately 40. The combined lensing bandpowers represent the most precise CMB lensing power spectrum measurement to date with a signal-to-noise ratio of 61 and an amplitude of $A_\mathrm{lens}^\mathrm{recon} = 1.025 \pm 0.017$ with respect to the theory prediction from the best-fit CMB \textit{Planck}-ACT cosmology. The bandpowers from all three lensing datasets, analyzed jointly, yield a $1.6\%$ measurement of the parameter combination $S_8^\mathrm{CMBL} \equiv σ_8\,(Ω_m/0.3)^{0.25} = 0.825^{+0.015}_{-0.013}$. Including Dark Energy Spectroscopic Instrument (DESI) Baryon Acoustic Oscillation (BAO) data improves the constraint on the amplitude of matter fluctuations to $σ_8 = 0.829 \pm 0.009$ (a $1.1\%$ determination). When combining with uncalibrated supernovae from \texttt{Pantheon+}, we present a $4\%$ sound-horizon-independent estimate of $H_0=66.4\pm2.5\,\mathrm{km\,s^{-1}\,Mpc^{-1}} $. The joint lensing constraints on structure growth and present-day Hubble rate are fully consistent with a $Λ$CDM model fit to the primary CMB data from \textit{Planck} and ACT. While the precise upper limit is sensitive to the choice of data and underlying model assumptions, when varying the neutrino mass sum within the $Λ\mathrm{CDM}$ cosmological model, the combination of primary CMB, BAO and CMB lensing drives the probable upper limit for the mass sum towards lower values, comparable to the minimum mass prior required by neutrino oscillation experiments.

Cosmology and Nongalactic Astrophysics (astro-ph.C↗

Thermal Infrared Spectral Band Detection Limits for Unidentified Surface Materials

Infrared emission spectra recorded by airborne or satellite spectrometers can be searched for spectral features to determine the composition of rocks on planetary surfaces. Surface materials are identified by detections of characteristic spectral bands. We show how to define whether to accept an observed spectral feature as a detection when the target material is unknown. We also use remotely sensed spectra measured by the Thermal Emission Spectrometer (TES) and the Spatially Enhanced Broadband Array Spectrograph System to illustrate the importance of instrument parameters and surface properties on band detection limits and how the variation in signal-to-noise ratio with wavelength affects the bands that are most detectable for a given instrument. The spectrometer's sampling interval, spectral resolution, signal-to-noise ratio as a function of wavelength, and the sample's surface properties influence whether the instrument can detect a spectral feature exhibited by a material. As an example, in the 6-13 micrometer wavelength region, massive carbonates exhibit two bands: a very strong, broad feature at approximately 6.5 micrometers and a less intense, sharper band at approximately 11.25 micrometers. Although the 6.5-micrometer band is stronger and broader in laboratory-measured spectra, the 11.25-micrometer band will cause a more detectable feature in TES spectra.

Kirkland, Laurel E.↗

Zones of information in the AVIRIS spectra

To make the best use of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data an investigator needs to know the ratio of signal to random variability or noise (S/N ratio). The signal is land-cover dependent and decreases with both wavelength and atmospheric absorption and random noise comprises sensor noise and intra-pixel variability. The three existing methods for estimating the S/N ratio are inadequate as typical laboratory methods inflate, while dark current and image methods deflate the S/N ratio. We propose a new procedure called the geostatistical method. It is based on the removal of periodic noise by notch filtering in the frequency domain and the isolation of sensor noise and intra-pixel variability using the semi-variogram. This procedure was applied easily and successfully to five sets of AVIRIS data from the 1987 flying season.

Curran, Paul J.↗

An Overdetermined System for Improved Autocorrelation Based Spectral Moment Estimator Performance

Autocorrelation based spectral moment estimators are typically derived using the Fourier transform relationship between the power spectrum and the autocorrelation function along with using either an assumed form of the autocorrelation function, e.g., Gaussian, or a generic complex form and applying properties of the characteristic function. Passarelli has used a series expansion of the general complex autocorrelation function and has expressed the coefficients in terms of central moments of the power spectrum. A truncation of this series will produce a closed system of equations which can be solved for the central moments of interest. The autocorrelation function at various lags is estimated from samples of the random process under observation. These estimates themselves are random variables and exhibit a bias and variance that is a function of the number of samples used in the estimates and the operational signal-to-noise ratio. This contributes to a degradation in performance of the moment estimators. This dissertation investigates the use autocorrelation function estimates at higher order lags to reduce the bias and standard deviation in spectral moment estimates. In particular, Passarelli's series expansion is cast in terms of an overdetermined system to form a framework under which the application of additional autocorrelation function estimates at higher order lags can be defined and assessed. The solution of the overdetermined system is the least squares solution. Furthermore, an overdetermined system can be solved for any moment or moments of interest and is not tied to a particular form of the power spectrum or corresponding autocorrelation function. As an application of this approach, autocorrelation based variance estimators are defined by a truncation of Passarelli's series expansion and applied to simulated Doppler weather radar returns which are characterized by a Gaussian shaped power spectrum. The performance of the variance estimators determined from a closed system is shown to improve through the application of additional autocorrelation lags in an overdetermined system. This improvement is greater in the narrowband spectrum region where the information is spread over more lags of the autocorrelation function. The number of lags needed in the overdetermined system is a function of the spectral width, the number of terms in the series expansion, the number of samples used in estimating the autocorrelation function, and the signal-to-noise ratio. The overdetermined system provides a robustness to the chosen variance estimator by expanding the region of spectral widths and signal-to-noise ratios over which the estimator can perform as compared to the closed system.

Keel, Byron M.↗

Long-Wave Infrared Dyson Spectrometer

Preliminary results are presented for an ultra compact long-wave infrared slit spectrometer based on the dyson concentric design. The dyson spectrometer has been integrated in a dewar environment with a quantum well infrared photodetecor (QWIP), concave electron beam fabricated diffraction grating and ultra precision slit. The entire system is cooled to cryogenic temperatures to maximize signal to noise ratio performance, hence eliminating thermal signal from transmissive elements and internal stray light. All of this is done while maintaining QWIP thermal control. A general description is given of the spectrometer, alignment technique and predicated performance. The spectrometer has been designed for optimal performance with respect to smile and keystone distortion. A spectral calibration is performed with NIST traceable targets. A 2-point non-uniformity correction is performed with a precision blackbody source to provide radiometric accuracy. Preliminary laboratory results show excellent agreement with modeled noise equivalent delta temperature and detector linearity over a broad temperature range.

imaging↗

Phasing the antennas of the Very Large Array (VLA) for reception of telemetry from Voyager 2 at Neptune encounter

The Very Large Array (VLA) radio telescope is being instrumented at 8.4 GHz to receive telemetry from Voyager 2 during its encounter with Neptune in 1989. The procedure in which the 27 antennas have their phases adjusted in near real time so that the signals from the individual elements of the array can be added coherently is examined. Calculations of the expected signal to noise ratio, tests of the autophasing process at the VLA, and off-line simulations of that process are all presented. Various possible procedures for adjusting the phases are considered. It is shown that the signal to noise ratio at the VLA is adequate for summing the signals from the individual antennas with less than 0.1 dB of loss caused by imperfect coherence among the antennas. Tropospheric variations during the summer of 1989 could cause enough loss of coherence to make the losses higher than 0.1 dB. Experiments show that the losses caused by the troposphere can probably be kept below 0.2 dB if the time delay inherent in the phase adjustment process is no longer than approx. 5 secs. This relatively small combining loss meets the goal estabished to minimize the bit error rate in the Voyager telemetry and implies adequate autophasing of the VLA.

Ulvestad, J. S.↗

Lock detection in Costas loops

Previous analyses of lock detector algorithms for Costas loops have ignored the effects of the inherent correlation between samples of the phase error process. In this paper, both analysis and simulations are used to quantify the effects of phase correlation on lock detection for the 'square law' and 'absolute value' type detectors. Results are obtained which depict the lock detection probability as a function of loop signal-to-noise ratio for a given false alarm rate. It is shown that the square law detector experiences less degradation due to phase jitter than the absolute value detector and that the degradation in detector signal-to-noise ratio is more pronounced for squarewave than for sinewave signals.

Mileant, A.↗

Unified and Consistent Structure Growth Measurements from Joint ACT, SPT, and Planck CMB Lensing

We present the tightest cosmic microwave background (CMB) lensing constraints to date on the growth of structure by combining CMB lensing measurements from the Atacama Cosmology Telescope (ACT), the South Pole Telescope (SPT), and Planck. Each of these surveys individually provides lensing measurements with similarly high statistical power, achieving signal-to-noise ratios of approximately 40. The combined lensing band powers represent the most precise CMB lensing power spectrum measurement to date with a signal-to-noise ratio of 61 and an amplitude of A lens recon = 1.025 ± 0.017 with respect to the theory prediction from the best-fit CMB Planck-ACT cosmology. The band powers from all three lensing datasets, analyzed jointly, yield a 1.6% measurement of the parameter combination S 8 CMBL ≡ σ 8 ( Ω m / 0.3 ) 0.25 = 0.82 5 - 0.013 + 0.015 . Including dark energy spectroscopic instrument baryon acoustic oscillation (BAO) data improves the constraint on the amplitude of matter fluctuations to σ 8 = 0.829 ± 0.009 (a 1.1% determination). When combining with uncalibrated supernovae from Pantheon+, we present a 4% sound-horizon-independent estimate of H 0 = 66.4 ± 2.5 km s - 1 Mpc - 1 . The joint lensing constraints on structure growth and present-day Hubble rate are fully consistent with a Λ CDM model fit to the primary CMB data from Planck and ACT. While the precise upper limit is sensitive to the choice of data and underlying model assumptions, when varying the neutrino mass sum within the Λ CDM cosmological model, the combination of primary CMB, BAO, and CMB lensing drives the probable upper limit for the mass sum towards lower values, comparable to the minimum mass prior required by neutrino oscillation experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dispersive Backend Design for the 'Double-Fourier' Interferometer BETTII

BETTII (Balloon Experimental Twin Telescope for Infra-red Interferometry) is designed to provide high angular resolution spectroscopic data in the far-infrared (FIR) wavelengths. The most significant limitation for BETTII is its sensitivity; obtaining spectral signal-to-noise ratio greater than 5 in less than 10 minutes requires sources greater than 13 Janskys (Jy). One possible way to improve the signal-to-noise ratio (SNR) for future BETTII flights is by reducing the spectral bandwidth post beam-combination. This involves using a dispersive element to spread out a polychromatic point source PSF (Point Spread Function) on the detector array, such that each pixel corresponds to a small fraction of the bandwidth. This results in a broader envelope of the interferometric fringe pattern allowing more fringes to be detected, and thereby improving the spectral SNR. Here we present the analysis and optical design of the dispersive backend, discussing the tradeoffs and how it can be combined with the existing design.

Dhabal, Arnab↗

Analysis of a Decision-Directed Receiver with Unknown Priors

A decision-directed receiver (DDR) uses previous outputs (decisions) to estimate unknown parameters and, on the basis of these estimates, modifies the detector structure for subsequent decisions. Although the DDR is less complex to instrument than other adaptive schemes, inherent in the decision-directed approach is the possibility of a runaway. This occurs when the detector commits a sequence of decision errors resulting in a degradation of parameter estimates, which, in turn, results in a further deterioration of detector performance. Because of the dependencies introduced by the learning process, runaway is difficult to analyze. In this paper, a DDR with unknown a priori probabilities is considered. The priors are estimated by the relative frequency of decisions of that event. For binary detection, it is shown that there is a positive probability of a runaway (the estimates converge to 1 or 0), which equals 1 if the signal-to-noise ratio is below a critical value. A tight bound on the probability of a runaway is obtained by approximating the learning process by a random walk with independent increments. The analysis demonstrates that a runaway is quite improbable even for moderate signal-to-noise ratios. The analysis is extended to multiple signals and to the situation where the estimates of the priors are updated continuously through exponential weighting rather than allowed to converge.

Davisson, Lee D.↗

Two-photon excitation of nitric oxide fluorescence as a temperature indicator in unsteady gasdynamic processes

A laser-induced fluorescence technique based on the pulsed two-photon excitation of NO is presented which is especially suited for the measurement of fluctuating temperatures in cold turbulent flows. The technique uses the fluorescence from the UV gamma bands of NO produced by two-photon excitation of NO (A 2 Sigma +, nu-prime = 0 - X 2 Pi, nu-double prime = 0) to obtain a rotational temperature. An analysis is presented of relevant aspects of the two-photon absorption process including microphysical processes, spectral intensities as a function of transition and laser spectral widths, line-shape integrals, the nonequilibrium response of the medium to a laser pulse, fluorescence energies, signal to noise ratio, and focusing effects. An analysis of absolute two-photon absorptivity measured in a nonflowing cell is then presented and used to predict signal to noise ratios greater than 50 for supersonic flows at temperatures below 300 K.

Mckenzie, R. L.↗

Optical phase-locked loop (OPLL) for free-space laser communications with heterodyne detection

Several advantages of coherent free-space optical communications are outlined. Theoretical analysis is formulated for an OPLL disturbed by shot noise, modulation noise, and frequency noise consisting of a white component, a 1/f component, and a 1/f-squared component. Each of the noise components is characterized by its associated power spectral density. It is shown that the effect of modulation depends only on the ratio of loop bandwidth and data rate, and is negligible for an OPLL with loop bandwidth smaller than one fourth the data rate. Total phase error variance as a function of loop bandwidth is displayed for several values of carrier signal to noise ratio. Optimal loop bandwidth is also calculated as a function of carrier signal to noise ratio. An OPLL experiment is performed, where it is shown that the measured phase error variance closely matches the theoretical predictions.

Win, Moe Z.↗

Optimum performance of suppressed carrier receivers with Costas loop tracking

The performance of suppressed carrier receivers with Costas loop tracking is optimized by proper choice of loop arm filter bandwidth. In particular, it is shown that for a variety of passive arm filter types, there exists, for a given data rate and data signal-to-noise ratio, an optimum filter bandwidth in the sense of minimizing the loop's squaring loss. For the linear theory case, this is equivalent to minimizing the loop's tracking jitter. When symbol synchronization is known, it is shown that by replacing the passive arm filters with active filters, i.e., integrate-and-dump circuits, one can achieve an improvement in carrier-to-noise ratio of as much as 4 to 6 dB depending on the passive arm filter type used for comparison and the value of data signal-to-noise ratio.

Simon, M. K.↗

Characterization of slow and fast phase nystagmus

A current literature review of the analog and digital process of vestibular and optical kinetic nystagmus reveals little agreement in the methods used by various labs. The strategies for detection of saccade (fast phase velocity component of nystagmus) vary between labs, and most of the process have not been evaluated and validated with a standard database. A survey was made of major vestibular labs in the U.S. that perform computer analyses of vestibular and optokinetic reflexes to stimuli, and a baseline was established from which to standardize data acquisition and analysis programs. The concept of an Error Index was employed as the criterium for evaluating the performance of the vestibular analysis software programs. The performance criterium is based on the detection of saccades and is the average of the percentages of missed detections and false detections. Evaluation of the programs produced results for lateral gaze with saccadic amplitude of one, two, three, five, and ten degrees with various signal-to-noise ratios. In addition, results were obtained for sinusoidal pursuit of 0.05, 0.10, and 0.50 Hz with saccades from one to ten degrees at various signal-to-noise ratios. Selection of the best program was made from the performance in the lateral gaze with three degrees of saccadic amplitude and in the 0.10 Hz sinusoid with three degrees of saccadic amplitude.

Lessard, Charles S.↗