Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL-TO-NOISE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Infrared Astronomical Satellite /IRAS/ Scientific Data Analysis System

The Infrared Astronomical Satellite (IRAS), to be launched in 1982, is discussed. It will systematically survey the entire sky over a large percentage of the infrared spectrum, in the wavelength region of 8 to 120 microns, at sensitivities a hundred times greater than previously achieved from high-altitude observatories, aircraft, balloons or sounding rockets. The Scientific Data Analysis System (SDAS), an off-line data processing facility, is examined. Its primary function is to produce a catalog of inertially fixed infrared-emitting point sources (mainly stars and galaxies) observed during the IRAS survey. Details for source detection and confirmation are given. It is estimated that the catalog will contain approximately a million objects having a brightness of 10 amtowatts per square centimeter or greater; 125,000 SDAS detections, if spurious events of signal-to-noise ratios greater than 2.5 are included, will be made every day.

Duxbury, J. H.↗

The recognition of extraterrestrial artificial signals

Considerations in the design of receivers for the detection and recognition of artificial microwave signals of extraterrestrial origin are discussed. Following a review of the objectives of SETI and the probable reception and detection characteristics of extraterrestrial signals, means for the improvement of the sensitivity, signal-to-noise ratios and on-line data processing capabilities of SETI receivers are indicated. The characteristics of the signals likely to be present at the output of an ultra-low-noise microwave receiver are then examined, including the system background noise, terrestrial radiations, astrophysical radiations, accidental artificial radiations of terrestrial origin, and intentional radiations produced by humans and by extraterrestrial intelligence. The classes of extraterrestrial signals likely to be detected, beacons and leakage signals, are considered, and options in the specification of gating and thresholding for a high-spectral resolution, high-time-resolution signal discriminator are indicated. Possible tests for the nonhuman origin of a received signal are also pointed out.

Seeger, C. L.↗

A design study of a signal detection system

A system is described which can aid in the search for radio signals from extraterrestrial sources, or in other applications characterized by low signal-to-noise ratios and very high data rates. The system follows a multichannel (16 million bin) spectrum analyzer, and has critical processing, system control, and memory fuctions. The design includes a moderately rich set of algorithms to be used in parallel to detect signals of unknown form. A multi-threshold approach is used to obtain high and low signal sensitivities. Relatively compact and transportable memory systems are specified.

Healy, T. J.↗

Orbits of nine Uranian rings

Observations of a stellar occultation by Uranus and its nine rings are presented and used to examine the structures and kinematics of the rings. The observations of the occultation of the K giant star KM 12 were obtained in the K band with the 4-m CTIO telescope at a signal-to-noise ratio higher than any previously obtained. Ring occultation profiles reveal the alpha ring to possibly have a double structure and less abrupt boundaries than the gamma ring, which exhibits diffraction fringes, while the eta ring is a broad ring with an unresolved narrow component at its inner edge. The present timing data, as well as previous occultation timings, are fit to a kinematic model in which all nine rings are treated as coplanar eclipses of zero inclination, precessing due to the zonal harmonics of the Uranian gravitational potential to obtain solutions for the ring orbits. Analysis of the residuals from the fitted orbits reveals that the proposed model is a good representation of ring kinematics. The reference system defined by the orbit solutions has also been used to obtain a value of 0.022 + or - 0.003 for the ellipticity of Uranus and a Uranian rotation period of 15.5 h.

Elliot, J. L.↗

A companion quasar to 3C345

The discovery of a new quasistellar object (QSO) which presents the strongest evidence to date for the membership of quasars in rich clusters is reported. During X-ray observations of quasar 3C345, a serendipitous X-ray source located 8 arcmin northeast of the quasar was discovered. The observed flux of the new source is 3.2 x 10 to the -13th erg/sq cm/sec in the 0.5-4.5 keV band. Three separate observations over a six-month period failed to show intensity variability in excess of the statistical uncertainty in the count rate. The spectrum shows a modest signal-to-noise ratio but four strong emission lines. It is suggested that the redshift agreement between the two QSOs indicates a common membership in a cluster of galaxies which may well be a rich cluster.

Margon, B.↗

Application of small-signal modeling and measurement techniques to the stability analysis of an integrated switching-mode power system

Small-signal modeling techniques are used in a system stability analysis of a breadboard version of a complete functional electrical power system. The system consists of a regulated switching dc-to-dc converter, a solar-cell-array simulator, a solar-array EMI filter, battery chargers and linear shunt regulators. Loss mechanisms in the converter power stage, including switching-time effects in the semiconductor elements, are incorporated into the modeling procedure to provide an accurate representation of the system without requiring frequency-domain measurements to determine the damping factor. The small-signal system model is validated by the use of special measurement techniques which are adapted to the poor signal-to-noise ratio encountered in switching-mode systems. The complete electrical power system with the solar-array EMI filter is shown to be stable over the intended range of operation.

Wong, R. C.↗

Integrated Submillimeter-Wave Mixer

Indium arsenide Schottky-Barrier diodes in gallium antimonide substrate mix submillimeter waves, producing much lower frequency output. Integrated diode array has relatively-high signal-to-noise ratio and wide frequency band. Operates at moderate cryogenic temperatures (100 K).

Maserjian, J.↗

Symbol error rate performance evaluation of the LM37 multimegabit telemetry modulator-demodulator unit

The LM37 multimegabit telemetry modulator-demodulator unit was tested for evaluation of its symbol error rate (SER) performance. Using an automated test setup, the SER tests were carried out at various symbol rates and signal-to-noise ratios (SNR), ranging from +10 to -10 dB. With the aid of a specially designed error detector and a stabilized signal and noise summation unit, measurement of the SER at low SNR was possible. The results of the tests show that at symbol rates below 20 megasymbols per second (MS)s) and input SNR above -6 dB, the SER performance of the modem is within the specified 0.65 to 1.5 dB of the theoretical error curve. At symbol rates above 20 MS/s, the specification is met at SNR's down to -2 dB. The results of the SER tests are presented with the description of the test setup and the measurement procedure.

Malek, H.↗

A photon-counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.

Hartig, G. F.↗

The effects of Viterbi decoder node synchronization losses on the telemetry receiving system

The Viterbi decoders currently used by the Deep space Network (DSN) use an algorithm for maintaining node synchronization that breaks down at bit signal-to-noise ratios (SNRs) of about 2.0 dB. It is shown that this can become an important consideration when the effects of noisy carrier referencing are combined with the lower SNRs that are expected at Voyager 2 Uranus and Neptune encounters. Depending on the available carrier power, node synchronization losses of between 0.85 and 1.25 dB can be expected in addition to the radio loss.

Deutsch, L. J.↗

Investigation of air transportation technology at Ohio University, 1981

The increased availability of Loran signals in the United States encouraged consideration of Loran for airborne applications. High quality signal processing to obtain effective signal-to-noise ratios which permit good reliability in position determination consistent with airborne applications is considered. Techniques for deriving air navigation quality information from Loran-C were investigated.

Mcfarland, R. H.↗

Thematic mapper performance

The thematic mapper primarily and its difference from MSS is reviewed. The TM has 30 meter resolution and the MSS has 80 meter resolution. This provides on agriculture an ability to accurately classify 10 acre fields with the TM versus 70 acre fields with the MSS data. There are six reflected light bands in the thematic mapper. Two bands are a new spectral region out in the IR, the shortwave IR region, as opposed to MSS's four reflected light bands. Four thematic mapper reflected light bands in the visible portion of the spectrum are designated to enhance the classification capability. The TM has better signal-to-noise ratio performance and radiometric sensitivity. The scan efficiency is increased through the use of bidirectional scanning, which gives a scan efficiency of 85% versus 45% with the multispectral scanner and more detectors per band. Greater encoding resolution is obtained in the multiplexer, 8 bit resolution versus 6 bits for MSS.

Engle, J.↗

An analysis of short pulse and dual frequency radar techniques for measuring ocean wave spectra from satellites

A four frequency moment characterization of backscatter from the near-vertical is applied to an analysis of the short pulse and dual frequency microwave techniques. The range reflectivity modulation spectrum closely approximates the directional wave slope spectrum, while harmonic distortion is small and is a minimum near 10 deg incidence. The short pulse measurement signal-to-noise ratio (SNR) is typically greater than the narrowband dual frequency SNR, with the difference being the ratio of the range beam extent to pulse length, minus the ratio of beam-limited to pulse-limited Doppler spreads. It is concluded that dual frequency measurements are basically impractical, although short pulse measurements are useful and can employ existing space-qualified microwave hardware.

Jackson, F. C.↗

Adaptive arrays - A new approach to the steady-state analysis

A closed-form expression for the steady-state output signal-to-noise ratio (SNR) of an n-element adaptive array excited by one desired narrow-band signal and K - 1 narrow-band jammers is obtained. This is facilitated by representing each excitation by a complex n-dimensional vector - the excitation vector. It is shown that the important system parameters are functions of scalar products of pairs of these excitation vectors. In particular, the normalized output SNR of the array is shown to be the ratio of determinants whose elements involve these scaler products. Such determinants are also shown to be involved in the expressions for the optimal array weights.

Zohar, S.↗

Conversion and matched filter approximations for serial minimum-shift keyed modulation

Serial minimum-shift keyed (MSK) modulation, a technique for generating and detecting MSK using series filtering, is ideally suited for high data rate applications provided the required conversion and matched filters can be closely approximated. Low-pass implementations of these filters as parallel inphase- and quadrature-mixer structures are characterized in this paper in terms of signal-to-noise ratio (SNR) degradation from ideal and envelope deviation. Several hardware implementation techniques utilizing microwave devices or lumped elements are presented. Optimization of parameter values results in realizations whose SNR degradation is less than 0.5 dB at error probabilities of .000001.

Ziemer, R. E.↗

Echelle spectroscopy with a charge-coupled device /CCD/

The recent availability of large format CCD's with high quantum efficiency makes it possible to achieve significant advances in high dispersion astronomical spectroscopy. An echelle CCD combination excels or equals other techniques presently available, and offers the advantage of complete spectral coverage of several thousand Angstroms in a single exposure. Attention is given to experiments which were conducted with a CCD camera head and an echelle spectrograph on a 4-meter telescope. It was found possible to achieve a signal-to-noise ratio of 150/1 on a 13th magnitude star at 6000 A in a two-hour exposure at 0.16 A/pixel, limited primarily by photon statistics. For fainter objects, readout noise is the limiting factor in precision. For 20 electron rms readout noise, an S/N = 15/1 at 18th magnitude is expected, all other things being equal.

York, D. G.↗

High-resolution imaging with a two-dimensional resistive anode photon counter

A method to achieve high spatial resolution readout of individual photoelectron events using microchannel plates and a resistive anode is presented. A clamped pair of microchannel plates is used, followed by a gap and a clamped triplet of microchannel plates in cascade to achieve a high stable electron gain of 3 x 10 to the 7th. The gain allows the position determination of each photoelectron event with a very high signal-to-noise ratio. A model consisting of a windowless vacuum-ultraviolet image sensor is presented to demonstrate 500 x 500 pixel images of 50 micron FWHM over a 25-mm circular field of view. The detector offers sufficient speed, sensitivity and resolution for a variety of applications, and the mount design is compatible with planar, remotely-processed, proximity-focused photocathodes.

Firmani, C.↗