Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE AND NETWORKING SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Energy efficiency evaluation of a stationary lithium-ion battery container storage system via electro-thermal modeling and detailed component analysis

Energy efficiency is a key performance indicator for battery storage systems. A detailed electro-thermal model of a stationary lithium-ion battery system is developed and an evaluation of its energy efficiency is conducted. The model offers a holistic approach to calculating conversion losses and auxiliary power consumption. Sub-models for battery rack, power electronics, thermal management as well as the control and monitoring components are developed and coupled to a comprehensive model. The simulation is parametrized based on a prototype 192 kWh system using lithium iron phosphate batteries connected to the low voltage grid. The key loss mechanisms are identified, thoroughly analyzed and modeled. Generic profiles featuring various system operation modes are evaluated to show the characteristics of stationary battery systems. Typically the losses in the power electronics outweigh the losses in the battery at low power operating points. The auxiliary power consumption dominates for low system utilization rates. For estimation of real-world performance, the grid applications Primary Control Reserve, Secondary Control Reserve and the storage of surplus photovoltaic power are evaluated. Conversion round-trip efficiency is in the range of 70-80%. Finally, overall system efficiency, which also considers system power consumption, is 8-13 percentage points lower for Primary Control Reserve and the photovoltaic-battery application. However, for Secondary Control Reserve, the total round-trip efficiency is found to be extremely low at 23% due to the low energy throughput of this application type.

25 ENERGY STORAGE↗

dCache project status and update

The dCache project delivers an open-source, massively scalable, distributed storage system deployed internationally to satisfy today’s scientists’ ever-demanding storage requirements. Its multifaceted approach supports different use cases with the same storage, from high throughput data ingest, data sharing over wide area networks, efficient access from HPC clusters, and longterm data persistence on tertiary storage. Even though dCache was initially developed for HEP experiments, today, it is used by various scientific communities, including astrophysics, biomed, and life science, each with their specific requirements. To match the needs of these new communities and keep up with the scaling demands of existing experiments, dCache is permanently evolving. With this contribution, we would like to highlight the recent developments in dCache regarding integration with CERN Tape Archive (CTA), advanced metadata handling, token-based authorization support, bulk API for QoS transitions, REST API to control interaction with the tape system, and future development directions.

Mkrtchyan, Tigran [DESY]↗

SEIN: Breaking Barriers Resilient Energy System Analysis [Slides]

The Solar Energy Innovation Network (SEIN) is a collaborative research program that supports multi-stakeholder teams in researching and sharing solutions to real-world challenges associated with solar energy adoption. The Breaking Barriers project was selected to participate in the Solar Energy Innovation Network, Round 2, and was led by Groundswell, a D.C.-based clean energy project developer. The Breaking Barriers team included Partnership for Southern Equity, Atlanta University Center campus facility managers and professors, the City of Atlanta's Neighborhood Planning Unit T, and Georgia Power Company. The project aimed to design and construct innovative urban energy resiliency hubs integrating microgrid technology, solar generation, and energy storage in Atlanta colleges and communities. The hubs will help these historically Black colleges and universities (HBCUs) and the energy-burdened broader community in West Atlanta be more resilient, in addition to informing new course curricula at Atlanta University Center campuses. With many possible options for the system's battery size, the Breaking Barriers team needed insight into the relationships between BESS size, economic performance, and resilience at Spelman College's Manley Center. These insights are crucial for entering procurement negotiations with project developers, establishing resilience capabilities that the HBCU campuses can plan around, and guiding the team's fundraising targets. This analysis includes estimates of PV and battery performance, costs, savings, and resilience for multiple battery sizes. In order to provide power during a grid outage, the resilient energy system also needs to be connected to the Manley Center in a safe and island-able manner (electrically isolated from the grid). Analysis of potential electrical configurations and estimated setup costs is key to successfully entering a required interconnection agreement with Georgia Power, as well as informing requests for engineering firms to construct the system. This analysis includes conceptual options and rough order of magnitude cost estimates for electrically interconnecting the resilient energy system to the Manley Center and the grid. The Breaking Barriers team used this analysis to select preferred system characteristics and design for the resilient energy system.

14 SOLAR ENERGY↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanistic understanding of carbon mineralization in fracture systems using microfluidics

Carbon mineralization in mafic and ultramafic rocks presents an opportunity for permanent carbon storage in the Earth's subsurface. However, due to their lower permeability, pre-existing fracture networks are key for mineralization to occur. Therefore, to fully develop this technology, a mechanistic understanding of the mineralization behavior in fractures with the consideration of hydrodynamic components is required. We use high-pressure microfluidics to investigate key mechanisms influencing dissolution–precipitation in a fracture network. The experiments were conducted in micromodels made of natural rocks with a comb-shaped flow channel to mimic a fracture network. This enabled studying the effect of injection rate on coupled dissolution–precipitation in advection and diffusion-dominated flow paths. We used gypsum carbonation as an analog reaction to allow for realistic experimental time frames due to its rapid reaction kinetics. The experimental work is coupled with high-fidelity numerical simulations to enhance our understanding of the parameters affecting the mineralization reaction. Our results demonstrate the importance of flow rate on the rate and nature of the gypsum carbonation reaction revealing that higher flow rates enable deeper penetration of the mineral precipitation front into the dead-end channels. This is an important finding since for sustained mineralization in a fracture network, precipitation in dead-ends while still allowing for flowing fractures is critical. Detailed characterization of the precipitates showed that lower flow rates led to porous and loose precipitates in the form of aragonite while higher flow rates mimicked supersaturation behavior leading to the formation of calcite. The reactive transport simulations further demonstrated the significance of flow velocity in advection-dominated channels to influence the efficiency of carbon mineralization in diffusion-dominated channels, potentially clogging of dead-end channels. These findings highlight the need for coupling chemical, mechanical, and hydrodynamic processes to evaluate the nature and extent of carbon mineralization in fractured media critical for permanent storage in mafic and ultramafic formations. This research further highlights the need for more investigation in potential subsurface fracture generation techniques to aid carbon mineralization.

25 ENERGY STORAGE↗

SMC 2021 : Analyzing Resource Utilization and User Behavior on Titan Supercomputer

Resource utilization statistics of submitted jobs on a supercomputer can help us understand how users from various scientific domains use HPC platforms and better design a job scheduler. We explore to generate insight regarding workload distribution and usage pattern domains from job scheduler trace, GPU failure information, and project-specific information collected from Titan supercomputer. Furthermore, we want to know how the scheduler performance varies over time and how the users' scheduling behavior changes following a system failure. These observations have the potential to provide valuable insight, which is helpful to prepare for system failures. These practices will help us develop and apply novel machine learning algorithms in understanding system behavior, requirement, and better scheduling of HPC systems. There are two datasets, RUR and GPU. RUR: This dataset is the job scheduler traces collected from the Titan supercomputerfrom 01/01/2015 to 07/31/2019 (2015.csv - 2019.csv). These were collected usingResource Utilization Report (RUR), a Cray-developed resource-usage data collectionand reporting system. It contains the usage information of its critical resources (CPU,Memory, GPU, and I/O) of each running job on Titan during that period [2]. ProjectAreas: Every job is associated with a project ID. TheProjectAreas.csvdatasetprovides a mapping of the project ID to its domain science. GPU: There have been some hardware-related issues in the GPUs in Titan that caused some GPUs to fail, sometimes irrecoverably during some job runs. This dataset provides information regarding these failures during the execution of the submitted jobs. GPUs on Titan are uniquely identified by a serial number (SN), and they are installed in a location. A GPU can be installed in a location, then removed from that location following a failure, and then re-installed in a different location after fixing the problem. If the failure can't be recovered, the GPU might be removed entirely from Titan. There are two prominent types of failures that resulted in the removal of GPUs from Titan: Double Bit Error (DBE) and Out of the Bus (OTB). The dataset (gc_full.csv) has the following fields: 1. SN : Serial number of a GPU 2. location : The location where it is installed 3. insert : The time when it was inserted into that location 4. remove : The time when it was removed from that location 5. duration : Amount of time the GPU spent in this location 6. out : If the device was taken out entirely w/o a re-installment into a new location. 7. event : If the GPU was taken out entirely, the reason for its removal. To learn more about this dataset, please refer to the git repositoryhttps://github.com/olcf/TitanGPULifeand the related publication [1]. References [1] George Ostrouchov, Don Maxwell, Rizwan A Ashraf, Christian Engelmann, MallikarjunShankar, and James H Rogers. Gpu lifetimes on titan supercomputer: Survival analysisand reliability. InSC20: International Conference for High Performance Computing,Networking, Storage and Analysis, pages 1-14. IEEE, 2020. [2] Feiyi Wang, Sarp Oral, Satyabrata Sen, and Neena Imam. Learning from five-yearresource-utilization data of titan system. In2019 IEEE International Conference onCluster Computing (CLUSTER), pages 1-6. IEEE, 2019.

42 ENGINEERING↗

Deep-learning-enhanced assessment of wellbore barrier effectiveness in geologic storage systems with intermediate aquifers

For geologic systems where carbon dioxide (CO 2 ) is injected underground, existing wells represent potential pathways for fluid migration. Here, this study introduces a novel deep learning model to quantify the likelihood and potential magnitude of fluid migration through wellbores at sites with intermediate aquifers or thief zones between the injection units and underground drinking water sources. Synthetic datasets, generated using reservoir simulations, captured a wide range of subsurface conditions, well attributes, operational parameters, and fluid migration scenarios. Among the regression models developed to predict brine and CO 2 leakage rates and CO 2 saturations along leaky wellbores, convolutional neural network (CNN) outperformed both Light Gradient Boosting Machine and deep neural network. Additionally, a CNN-based classification model was created to predict whether brine and CO 2 would leak along a wellbore, further improving performance over regression alone. The best models were integrated into the National Risk Assessment Partnership Open-source Integrated Assessment Model for rapid, stochastic assessment of storage system containment and leakage risks. A case study demonstrated the model’s ability to simulate fluid migration through existing wells with multiple intermediate aquifers. This computationally efficient wellbore model offers value in support of site performance evaluation and risk-informed decision making by stakeholders.

CO2 leakage↗

Distributed Energy Resources Coordination over Time-varying Directed Communication Networks

In this paper, we consider an optimal coordination problem for distributed energy resources (DERs) including distributed generators and energy storage devices. We first propose an algorithm based on the push-sum and gradient method to optimally coordinate storage devices and distributed generators in a distributed manner. In the proposed algorithm, each DER only maintains a set of variables and updates them through information exchange with a few neighboring DERs over a time-varying directed communication network. We show that the proposed distributed algorithm with appropriately chosen step-sizes solve the optimal DER coordination problem if the time-varying directed communication network is uniformly jointly strongly connected, which is a mild condition on the connectivity of communication topologies. The proposed distributed algorithm is illustrated and validated by numerical simulations.

Yang, Tao↗

A Risk-Averse Approach for Distribution Grid Expansion Planning

Recent episodes of natural disasters have challenged the resilience of power grids. Adequate distribution grid planning that properly captures the risk aversion of the utility system planner is a key factor to increase the flexibility of distribution networks to circumvent these events. In this paper, we propose a methodology to determine the optimal portfolio of investments in lines and storage devices in order to minimize a convex combination between expected value and CVaR of operational costs, including energy not served, while taking into account the multistage nature of the energy storage management within this context. While the expected value of energy not served has been traditionally employed to tackle routine failures, we also minimize the CVaR of energy not served to address high-impact, low-probability (HILP) events. We illustrate the performance of the proposed methodology with a 54-Bus system test case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impedance-Based Characterization of Power System Frequency Response: Preprint

This paper presents an impedance-based noninvasive approach for the characterization of power system frequency response in real time in the absence of a transient event. It measures transfer function response from the injected active power to the frequency at the point of interconnection for the estimation of inertia and primary frequency response of the system. The so-called frequency response function also shows the effects of the speed of primary frequency control. The paper also derives the relationship between the frequency response function and the network impedance seen from the point of interconnection. This relationship highlights how impedance captures the frequency response behavior of a network. The proposed methodology is demonstrated on a modified IEEE 9-bus system with 25% penetration of wind and PV generation; a 5-MW battery energy storage system is used for the injection of active power perturbations for the measurement of the frequency response function.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Reversible Methane Electrochemical Reactors as Efficient Energy Storage for Fossil Power

The overall objective of the project was to conduct a comprehensive Research & Development (R&D) program to demonstrate the suitability and future advancement and integration of reversible methane protonic ceramic electrochemical reactors (PCERs) as an efficient Energy Storage System (ESS) with fossil fuel power plants. Fundamental process and system models are developed to conduct a preliminary conceptual study and investigate the power plant system integration requirements, performance requirements, and technical and non-technical gaps for eventual implementation at system level. Technology maturation requirements is also investigated through identifying the critical technical elements and networking with industrial technology developers and end-users.

08 HYDROGEN↗

Cyber-Physical Events Emulation Based Transmission and Distribution Co-Simulation for Situation Awareness and Grid Anomaly (SAGA) Detection: Preprint

Energy management of transmission and distribution networks is becoming more challenged with the accelerated increasing of distributed energy resources (DERs) such as distributed photovoltaic (PV) generation and distributed energy storage. To better analyze the impacts of DERs on both transmission and distribution systems, a comprehensive transmission and distribution co-simulation platform should be developed. Furthermore, with DERs more actively participated in system operation such as providing real time grid services, their cyber vulnerability should be better understood to maintain system reliability. This paper discussed a cyber-physical events emulation based transmission & distribution co-simulation platform to perform different cyber events emulation and analyze the impacts of cyber physical events happened in distribution system on the T&D system operation. The case studies with both a transmission network and a synthetic distribution network data validate that the proposed T&D co-simulation platform can perform comprehensive cyber physical events emulation. Therefore, with extensive simulation using the proposed model, the system operator can accumulate adequate training data for the system situation awareness and grid anomaly detection purpose.

31 CESER - Office of Cybersecurity, Energy Securit↗

Formulation and Performance Evaluation of Epoxy Sealant Systems for Double-Shell Tank Bottom Refurbishment

The performance of epoxy sealants used in the refurbishment of double-shell tank (DST) systems requires balancing processability, thermomechanical stability, and adhesion to cementitious substrates. This study incorporates Heloxy 8 as a reactive diluent into Westlake 862 epoxy to tailor workability and cured-state properties. Rheological time-sweep analysis demonstrates that increasing the diluent content significantly reduces complex viscosity and extends workability, thereby improving pumpability and flow for large-area applications. However, the targeted 2-hour processing window is not fully achieved. Differential scanning calorimetry (DSC) confirms that all formulations cure at room temperature to glass transition temperatures ( T g ) at least 20 °C above the maximum DST operating temperature (27 °C), thereby ensuring service in the glassy regime. Dynamic mechanical analysis (DMA) reveals formulation-dependent reductions in tan delta and increases in storage modulus, indicating increasingly elastic and mechanically stable networks with diluent incorporation. Pull-off adhesion testing shows that modified formulations (70–90% Westlake epoxy) exhibit significantly higher adhesion strengths than the unmodified system. Grout cohesive failure indicates that interfacial bonding exceeds substrate strength. Collectively, these results demonstrate that controlled reactive diluent incorporation enables optimization of processing behavior, interfacial adhesion, and thermomechanical performance, supporting the suitability of the modified epoxy systems as durable sealant layers for cementitious barrier applications in hazardous waste containment infrastructure.

Differential scanning calorimetry↗

Release a public version of HERON (HERON 2.0) with improved algorithms for the treatment of energy storage

Integrated energy systems (IESs) are essential for decarbonizing electricity and industrial sectors and fully exploiting these systems requires sophisticated planning, scheduling, and dispatching tools to maximize their socio-economic benefits. The Holistic Energy Resource Optimization Network (HERON) is a generic software plugin for the Risk Analysis Virtual Environment (RAVEN) to perform stochastic technoeconomic analysis of IES with economic drivers. This report summarizes the updates made to HERON 2.0. Particularly, we demonstrate one of the added features, Function-based Control Mechanics, by comparing a price-based dispatch strategy with the original perfect foresight baselines. Our case studies successfully demonstrate that the model is capable to incorporate artificial control algorithm into the dispatch of IES components. In addition, our results from the price-based strategy indicate that the control strategies of IES components are key to the economic and temporal performance of our model; therefore, more sophisticated dispatch strategies are required to improve the model performance.

25 ENERGY STORAGE↗

Optimizing Carbon Capture, Transport, and Storage: Overcoming Challenges with Machine Learning and Cost-Benefit Analysis

Carbon Capture, Utilization, and Storage (CCUS) is a critical strategy for reducing CO₂ emissions and mitigating climate change. However, its widespread deployment faces numerous challenges across the capture, transport, and storage phases. These challenges include the technical complexity of predicting subsurface behaviors during CO₂ injection, ensuring long-term storage integrity, optimizing transportation networks, and balancing the economic and environmental trade-offs. Addressing these issues requires an integrated approach combining advanced subsurface modeling with system-level analyses to assess costs, risks, and benefits. This presentation provides an overview of studies conducted by the National Energy Technology Laboratory (NETL) to tackle these challenges. NETL’s efforts encompass cutting-edge research in subsurface fluid behavior machine learning predictions, alongside the development of innovative tools for system optimization and economic evaluation. By bridging technical expertise and strategic analysis, NETL aims to advance the deployment of CCUS technologies to support global decarbonization efforts. Presented at the Carnegie Mellon University CEE IESS Student Seminar October 4, 2024.

Shih, Chung Yan↗

Stakeholder-guided holistic, Adaptive Framework for enhancing community Energy Resilience (SAFER) (Final Technical Report)

The Stakeholder-guided holistic, Adaptive Framework for enhancing community Energy Resilience (SAFER) project advances resilience science and engineering by addressing challenges in rural Kansas communities where aging infrastructure, extreme weather, and socioeconomic disparities heighten vulnerability to energy disruptions. Traditional approaches often focus on technical performance while overlooking community concerns and priorities. SAFER responds by integrating community perspectives with advanced analytical frameworks to create a holistic model for measuring and improving resilience. Project objectives included developing novel resilience metrics, advancing modeling frameworks that capture interdependencies across infrastructures, and embedding community-centric indicators directly into planning processes for distributed energy resources. The key technical innovations included the creation of self-organizing map (SOM)-based indices for objective resilience quantification, hetero-functional graph theory (HFGT) models linking power, water, transportation, and community assets, and graph neural network (GNN) tools for identifying critical nodes in complex systems. Community-centric energy planning was demonstrated through optimal siting and sizing of (photovoltaic) PV and battery storage, ensuring resilience enhancements also addressed energy burden and energy insecurity. SAFER engaged community partners in Dodge City and Ford County through surveys, focus groups, and workshops, generating more than 600 responses that established baseline measures of energy burden, financial insecurity, and willingness-to-pay to avoid outages. This data, organized in terms of a community capitals framework, informed the development of weighted reliability indices that better reflect community costs than traditional utility metrics. SAFER’s GNN-based critical node identification framework identified expert-labelled critical nodes with over 99% accuracy, while also uncovering additional functionalities essential for proactive resilience planning. The project’s models demonstrated that optimal PV and storage deployment could improve resilience indices by over 11 percent, with dispatch strategies further enhancing outcomes, confirming both the technical effectiveness and economic feasibility of these approaches. Through its combined emphasis on rigorous modeling, community-focused planning, and community engagement, SAFER advances the state of resilience research while delivering direct benefits to rural communities. The project provides tools, guidelines, and resilience heatmaps that help utilities, local governments, and residents better anticipate disruptions, prioritize investments, and strengthen the capacity to withstand and recover from energy-related hazards. Furthermore, the developed HFG and GNN frameworks are designed for transferability, allowing them to be adapted for resilience planning in other communities with minimal retraining. This inductive learning capability provides a scalable pathway to extend the SAFER project’s impact. Thus, creating a foundation for a nationally applicable model of infrastructure resilience. Additionally, the HFG can also be extended to include other FEMA community lifelines.

14 SOLAR ENERGY↗

Lessons Learned for Rapid Decarbonization Of Power Sectors: Key Messages for Energy Ministers

This report covers key lessons learned for the rapid decarbonization of power systems, emphasizing best practices in planning, building, and operating power systems. This report is the result of a collaborative effort among various Clean Energy Ministerial (CEM) workstreams and partner initiatives: 21st Century Power Partnership (21CPP); Carbon Capture, Utilization and Storage (CCUS); Global Power System Transformation Consortium (G-PST), a partner to CEM; Industrial Deep Decarbonization Initiative (IDDI); International Energy Agency Digital Demand-Driven Electricity Networks Initiative (IEA 3DEN), a partner to CEM; International Smart Grid Action Network (ISGAN); Long Term Scenarios for the Energy Transition (LTES); Nuclear Innovation: Clean Energy Future (NICE Future); Super-Efficient Equipment and Appliance Deployment (SEAD). The contents are not intended to be comprehensive of all power sector topics, and there may be overlap between content in each section due to the nature of this first-of-its-kind collaborative effort to deliver unified messaging on power sector decarbonization to energy ministers. This work is intended to complement other work at the Clean Energy Ministerial and offers options for consideration, not specific policy recommendations.

21CPP↗