Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Quantum-Assisted Algorithm for Sampling Applications in Machine Learning

An increase in the efficiency of sampling from Boltzmann distributions would have a significant impact in deep learning and other machine learning applications. Recently, quantum annealers have been proposed as a potential candidate to speed up this task, but several limitations still bar these state-of-the-art technologies from being used effectively. One of the main limitations is that, while the device may indeed sample from a Boltzmann-like distribution, quantum dynamical arguments suggests it will do so with an instance-dependent effective temperature, different from the physical temperature of the device. Unless this unknown temperature can be unveiled, it might not be possible to effectively use a quantum annealer for Boltzmann sampling. In this talk, we present a strategy to overcome this challenge with a simple effective-temperature estimation algorithm. We provide a systematic study assessing the impact of the effective temperatures in the learning of a kind of restricted Boltzmann machine embedded on quantum hardware, which can serve as a building block for deep learning architectures. We also provide a comparison to k-step contrastive divergence (CD-k) with k up to 100. Although assuming a suitable fixed effective temperature also allows to outperform one step contrastive divergence (CD-1), only when using an instance-dependent effective temperature we find a performance close to that of CD-100 for the case studied here. We discuss generalizations of the algorithm to other more expressive generative models, beyond restricted Boltzmann machines.

Perdomo-Ortiz, Alejandro↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Summary of Proton Test on the Actel A1280A at Indiana University

A summary of tests performed at the Indiana University Cycl,oltron Facility, on the Actel A1280A circuit device is described. The intent of the study was to investigate the proton response of the hard-wired S-Module flip-flops with a large sample size. This device is sensitive to protons for S-Modules. The device's performance in the test is shown in graphs, and was typical for devices of this class.

Katz, Richard↗

Impact of Total Ionizing Dose Radiation Testing and Long-Term Thermal Cycling on the Operation of CMF20120D Silicon Carbide Power MOSFET

Power systems designed for use in NASA space missions are required to work reliably under harsh conditions including radiation, thermal cycling, and extreme temperature exposures. Silicon carbide devices show great promise for use in future power electronics systems, but information pertaining to performance of the devices in the space environment is very scarce. A silicon carbide N-channel enhancement-mode power MOSFET called the CMF20120 is of interest for use in space environments. Samples of the device were exposed to radiation followed by long-term thermal cycling to address their reliability for use in space applications. The results of the experimental work are presentd and discussed.

thermal cycling tests↗

Spin and Charge Interconversion in Dirac-Semimetal Thin Films

We use spin torque ferromagnetic resonance and ferromagnetic-resonance-driven spin pumping to detect spin-charge interconversion at room temperature in heterostructure devices that interface an archetypal Dirac semimetal, Cd 3 As 2 , with a metallic ferromagnet, Ni 0.80 Fe 0.20 (permalloy). Angle-resolved photoemission directly reveals the Dirac-semimetal nature of the samples prior to device fabrication and high-resolution transmission electron microscopy is used to characterize the crystalline structure and the relevant heterointerfaces. We find that the spin-charge interconversion efficiency in Cd 3 As 2 /permalloy heterostructures is comparable to that in heavy metals and that it is enhanced by the presence of an interfacial oxide. Spin torque ferromagnetic resonance measurements reveal an in-plane spin polarization regardless of an oxidized or pristine interface. We discuss the underlying mechanisms for spin-charge interconversion by comparing our results with first principles calculations and conclude that extrinsic mechanisms dominate the observed phenomena. Our results indicate a need for caution in interpretations of spin-transport and spin-charge conversion experiments in Cd 3 As 2 devices that seek to invoke the role of topological Dirac and Fermi arc states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploration Atmosphere Demonstration of A Multi-Functional Integrated Medical Device (Tempus Pro)

INTRODUCTION The Exploration Medical Capability (ExMC) element within the Human Research Program and the Exploration Medical Integrated Product Team (XMIPT) within the Mars Campaign Office seek to advance medical system design and risk-informed decision-making for exploration missions. This includes assessment of candidate devices and their compatibility within a variety of increasingly Earth-independent medical scenarios. The Tempus Pro (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf (COTS), multi-functional integrated medical device capable of vital signs monitoring, with built-in procedure support (iAssist), patient record and telemedicine communication features, and medical imaging (e.g., camera, laryngoscope, ultrasound) that meets multiple exploration medical capability needs. One of several hypobaric atmospheres being considered for exploration vehicles is 8.2 psi with 34% oxygen. To assess the useability of the Tempus Pro in such environments by individuals without formal medical training, the unit was tested in May and June of 2023 at the Johnson Space Center 20-Foot Exploration Atmosphere Chamber in conjunction with the Exploration Atmospheres-2 (EA-2) study. TECHNOLOGY DEMONSTRATION Eight subjects in the EA-2 study were assigned roles as the caregiver or patient – or both in the case of a self-exam – and caregivers were asked to place sensors for 3-Lead ECG, non-invasive blood pressure (NIBP), pulse oximetry (SpO2), and temperature using Tempus Pro’s iAssist. Depending on the procedure, additional tasks included an oropharyngeal exam of the throat with the laryngoscope and capturing ultrasound images of a cardiac subxiphoid view or of the user’s choice from a pre-specified list. Scenarios ranged from remote-guided to fully autonomous operations and surveyed the effectiveness of support, amount of support desired, and importance of support by type (e.g., written crew procedures, iAssist and device guidance, remote console guidance, etc.). Feedback from the subjects and the support personnel was also gathered to inform future designs for training and support and to determine what operations are plausible given different levels of each. An unweighted NASA task load index (TLX) was used to profile the demands of using the device, however the sample size does not support statistics. The research was exploratory in nature and qualitative information was the main goal. Calibration checks on the Tempus Pro were conducted before and after chamber testing to ensure the device was in useable condition. RESULTS All subjects performed their tasks successfully and found the Tempus Pro easy to use with the support provided. The calibration checks outside the chamber showed that the Tempus Pro remained unchanged and measurements inside the chamber were within normal values. Caregivers taking the NASA TLX reported mean scores ≤ 41/100 showing the tasks to be undemanding and less demanding with repeated use (~20/100). Novice users were able to easily connect sensors and take vital signs with the guidance from Tempus Pro’s iAssist feature. For more complex tasks, such as the oropharyngeal exam and ultrasound image acquisition, guidance beyond iAssist was needed, primarily from a supporting physician. Feedback on the importance of support types varied by person and scenario but greater than 50% of the support used by each was non-native to the device. Overall opinions were positive, but the ultrasound users expressed a lack of confidence in their results and 3 out of 4 desired more time, training, or support. Subjects found the sensors to be comfortable and comparable to prior experiences with such devices, except for the blood pressure cuff, which squeezed too tightly for uncomfortably long periods. Many observations provoked discussion, especially regarding ultrasound, that will aide decisions about future demonstrations.

R. S. Miller↗

Using electron channeling contrast imaging to inform and improve the growth of high-efficiency GaAs solar cells on nanopatterned GaAs substrates

Patterned substrates provide opportunities for reducing the cost of high-efficiency III-V devices by incorporating mechanically weak layers beneficial for substrate reuse (e.g. by spalling). In this work, the functionality of electron channeling contrast imaging (ECCI) as a tool to efficiently understand and mitigate defect formation is exemplified by developing a process in which high-quality III-V material can be grown on nanopatterned GaAs substrates. Reactive ion etching used in the patterning process was found to damage the GaAs substrate surface, leading to the formation of stacking faults in the epitaxial material as observed by ECCI. Etching the patterned substrates in a 1 NH4OH: 1 H2O2: 50 DI H2O solution for 10 s prior to growth removed the substrate surface damage and stacking faults were no longer present. Growth of solar cell device structures initially produced samples with many macroscale flaws creating shunts in the devices, which complicated the assessment of material quality by device measurements. However, ECCI revealed that the epitaxial material surrounding macroscale flaws was free from any crystallographic defects such as stacking faults and threading dislocations. With this knowledge, we focused on refining the patterning process to eliminate the macroscale flaws. Solar cells were then grown on the improved nanopatterned substrates and exhibited device structures with defect densities less than 5 x 105 cm -2 and average conversion efficiency of 24.8%, nearly identical to devices grown on unpatterned epi-ready substrates (25.0%).

14 SOLAR ENERGY↗

Fracture Tests of Etched Components Using a Focused Ion Beam Machine

Many optical MEMS device designs involve large arrays of thin (0.5 to 1 micron components subjected to high stresses due to cyclic loading. These devices are fabricated from a variety of materials, and the properties strongly depend on size and processing. Our objective is to develop standard and convenient test methods that can be used to measure the properties of large numbers of witness samples, for every device we build. In this work we explore a variety of fracture test configurations for 0.5 micron thick silicon nitride membranes machined using the Reactive Ion Etching (RIE) process. Testing was completed using an FEI 620 dual focused ion beam milling machine. Static loads were applied using a probe. and dynamic loads were applied through a piezo-electric stack mounted at the base of the probe. Results from the tests are presented and compared, and application for predicting fracture probability of large arrays of devices are considered.

Kuhn, Jonathan, L.↗

Scalable Asset Discovery, Vulnerability Scanning, and Penetration Testing for Remote Sites and Wireless Spectrums Utilizing an Embedded Linux Plug - PwniPlug and the Raspberry Pi B+ as a Sample Pen Test

All devices attached to the NASA KSC network are subject to security vulnerability scanning and/or penetration testing. In today's changing environment, vulnerable and/or unprotected systems can easily be overlooked. Systems that are not properly managed can become a potential threat to the operational integrity of our systems and networks. This includes all NASA (internal and external) information systems within NASA KSC Internet Protocol (IP) address space, and NASA KSC facilities. The Office of the Chief Information Officer (OCIO) recommends that all NASA Centers and information systems be subject to penetration testing on a regular interval in accordance with the guidelines identified by the National Institute of Standards and Technology (NIST). (ITS-HBK-2810.04-02A) Protecting information and equipment at NASA is an area of increasing concern. In addition to the CPU's on the network; Supervisory, Control and Data Acquisition (SCADA) systems are especially vulnerable because these systems have lacked standards, use embedded controllers with little computational power and informal software, are connected to physical processes, have few operators, and are increasingly also being connected to corporate networks. The scope of work is comprised of several individual components which together build upon previous work by Drew Branch, NASA KSC Intern. The Pwn Plug is the selected COTS (Commercial-Off-The-Shelf) device chosen to test simplification of mandatory IT Security tasks. The device will be utilized to provide services to NASA KSC and enable an assessment of infrastructure soundness and regulatory compliance in an efficient, economical, and business responsive manner. The Pwn Plug is designed as a pen testing appliance which provides a hardware platform that can support commercial penetration testing efforts at significantly reduced costs. The expected outcomes are: 1) External Penetration Testing, 2) Social Engineering, 3) Procedural Documentation, 4) Recommended Remediation Action Plan, 5) System Retest & Remediation Attestation and 6) Final Reports, out briefing and Presentation. Due to physical and material constraints beyond intern and mentor control, the project was redefined as a working pen-test scenario. Limitations of lab availability and tools dictated an academic exercise. This report was developed within the scenario guidelines suggested by the project mentor. The guidelines were to be creative in developing a Pen Test program for a client.

Penetration Testing↗

Porous membrane enabled mass spectrometry characterization of microfluidic devices

A system for sampling a liquid includes a sample fluid conduit including a membrane having pores. The membrane prevents the passage of the sample liquid through the pores at a first pressure of the sample liquid in the sample fluid conduit. A surface sampling capture probe has a distal end. The capture probe includes a solvent supply conduit and a solvent exhaust conduit. A solvent composition flowing at the distal end of the capture probe establishes a liquid junction with the membrane and establishes a second pressure within the liquid junction at the membrane. The second pressure is lower than the first pressure. Sample liquid will be drawn through the pores of the membrane by the second pressure at the liquid junction. A method for sampling a liquid and for performing chemical analysis on a liquid are also disclosed.

Cahill, John F.↗

Porous membrane enabled mass spectrometry characterization of microfluidic devices

A system for sampling a liquid includes a sample fluid conduit including a membrane having pores. The membrane prevents the passage of the sample liquid through the pores at a first pressure of the sample liquid in the sample fluid conduit. A surface sampling capture probe has a distal end. The capture probe includes a solvent supply conduit and a solvent exhaust conduit. A solvent composition flowing at the distal end of the capture probe establishes a liquid junction with the membrane and establishes a second pressure within the liquid junction at the membrane. The second pressure is lower than the first pressure. Sample liquid will be drawn through the pores of the membrane by the second pressure at the liquid junction. A method for sampling a liquid and for performing chemical analysis on a liquid are also disclosed.

Cahill, John F.↗

FY12 End of Year Report for NEPP DDR2 Reliability

This document reports the status of the NEPP Double Data Rate 2 (DDR2) Reliability effort for FY2012. The task expanded the focus of evaluating reliability effects targeted for device examination. FY11 work highlighted the need to test many more parts and to examine more operating conditions, in order to provide useful recommendations for NASA users of these devices. In order to develop these approaches, it is necessary to develop test capability that can identify reliability outliers. To do this we must test many devices to ensure outliers are in the sample, and we must develop characterization capability to measure many different parameters. For FY12 we increased capability for reliability characterization and sample size. We increased sample size by moving from loose devices to DIMMs with an approximate reduction of 20 to 50 times in terms of per DUT cost. By increasing sample size we have improved our ability to characterize devices that may be considered reliability outliers. This report provides an update on the effort to improve DDR2 testing capability. Although focused on DDR2, the methods being used can be extended to DDR and DDR3 with relative ease.

temperature stress↗

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

data retention↗

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

Data Retention↗

Development of an advanced spacecraft tandem mass spectrometer

The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

Drew, Russell C.↗