Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

An antenna for limited scan in one plane - Design criteria and numerical simulation

Aperture illumination is synthesized through the use of overlapping subarrays with independently controlled excitations. Detailed analysis and design criteria are provided for a specific limited-scan antenna configuration scanning in one plane. The number of phase shifts is the theoretical minimum corresponding to specified aperture size and field of view. Beam pointing and width are approximately constant for moderate frequency variation, and ultralow sidelobes outside the field of view can be produced at the cost of a slight loss of illumination efficiency. Accurate aperture illumination control makes for excellent independently specified sum and difference patterns in beamforming.

Borgiotti, G. V.↗

High Energy Astronomy Observatory program

The series of three orbiting high energy astronomy observatories that comprise the HEAO program are described. Several unique designs as well as the attitude control and determination system, used for observatory scan rotation of the first and third missions and for precision pointing on the second mission, are analyzed. Attention is given to observatory requirements, design characteristics, and the RGA performance summary.

Wojtalik, F. S.↗

Bennett ion mass spectrometers on the Pioneer Venus Bus and Orbiter

Identical Bennett radio-frequency ion mass spectrometer instruments on the Pioneer Venus Bus and Orbiter have provided the first in-situ measurements of the detailed composition of the planet's ionosphere. The sensitivity, resolution, and dynamic range are sufficient to provide measurements of the solar-wind-induced bow-shock, the ionopause, and highly structured distributions of up to 16 thermal ion species within the ionosphere. The use of adaptive scan and detection circuits and servo-controlled logic for ion mass and energy analysis permits detection of ion concentrations as low as 5 ions/cu cm and ion flow velocities as large as 9 km/sec for O(+). A variety of commandable modes provides ion sampling rates ranging from 0.1 to 1.6 sec between measurements of a single constituent. A lightweight sensor and electronics housing are features of a compact instrument package.

Taylor, H. A., Jr.↗

Spatial conductivity measurements on high T(sub c) superconducting films

High T(sub c) superconducting thin and thick films have potential applications in future NASA flight projects. In anticipation of film use, the Materials Branch is developing a nondestructive, non-contact method of measuring the spatial variation of conductivity across a film sample. This method uses a computer-controlled, X-Y positioning table to scan a conventional eddy current probe across the surface of a film. The induced changes in impedance caused by variations in film conductivity are recorded during the scanning process. Ultimately the two-dimensional data set is displayed using imaging equipment on a personal computer.

Vansant, J. Timothy↗

Automated Surface Profilometer

Computer-controlled system saves time and labor. Electromechanical scanning system automatically measures deviation of sheets and plates from flatness. Quickly measures surface profile and detects bumps, bulges, and indentations as small as 0.001 in. in height or depth. X-y table moves specimen to programmed locations under digital linear variable differential transformer (LVDT) while computer records surface-height readings of LVDT. Resulting graphical display shows surface contour.

Chern, E. James↗

Head-Up Displays and Attention Capture

The primary role of head-up displays (HUDs) is to provide primary flight, navigation, and guidance information to the pilot in a forward field-of-view on a head-up transparent screen. Therefore, this theoretically allows for optimal control of an aircraft through the simultaneous scanning of both instrument data and the out-the-window scene. However, despite significant aviation safety benefits afforded by HUDs, a number of accidents have shown that their use does not come without costs. The human factors community has identified significant issues related to the pilot distribution of near and far domain attentional resources because of the compellingness of symbology elements on the HUD; a concern termed, attention or cognitive capture. The paper describes the phenomena of attention capture and presents a selected survey of the literature on the etiology and potential prescriptions.

Prinzel, Lawrence J., III↗

Characterization of Collection Efficiency of the Common Research Model Midspan Wing Section in the IRT

This paper presents a preliminary study for the characterization of collection efficiency from icing tests conducted in the Icing Research Tunnel at NASA Glenn Research Center. A test method previously developed for measuring the attachment line maximum collection efficiency of a swept NACA 0012 airfoil model at zero angle of attack was applied to the leading-edge region of a 65%-scale version of the Common Research Model midspan wing section. A correlation for the stagnation line maximum collection efficiency as a function of the modified inertia parameter was obtained with LEWICE3D simulations utilizing a discrete number of drop diameters. It was then compared with the collection efficiency measurement data obtained in the IRT. For the experimental collection efficiency, two ice shape digitization procedures were utilized to extract 2-D chord-wise ice shape profiles, i.e., the Maximum Combined Cross Section or MCCS, and the Minimum Combined Cross Section or Min CCS, at selected span-wise locations from the 3-D scanned ice shapes. The preliminary result showed that the rime ice thickness method can be used to characterize the collection efficiency distribution, for conditions free of ice erosion, in the main ice shape region. However, a high-order statistical processing of the ice scan is needed for estimating the mean ice thickness in areas where feathers are prevalent. From the limited comparison of the experimental and LEWICE3D collection efficiency data in the CRM65 MS model leading edge area, it was shown that the attachment line maximum collection efficiency is reasonably estimated by the best curve-fit correlation in the range of modified inertia parameter tested. A tighter alignment control of the iced and cold clean model scans is needed to improve the comparison. Further evaluation of this correlation is recommended to assess its applicability for Common Research Model type swept wing icing scaling analysis.

Ice Scailing↗

Characterization of Collection Efficiency of the Common Research Model Midspan Wing Section in the IRT

This paper presents a preliminary study for the characterization of collection efficiency from icing tests conducted in the Icing Research Tunnel at NASA Glenn Research Center. A test method previously developed for measuring the attachment line maximum collection efficiency of a swept NACA 0012 airfoil model at zero angle of attack was applied to the leading-edge region of a 65%-scale version of the Common Research Model midspan wing section. A correlation for the stagnation line maximum collection efficiency as a function of the modified inertia parameter was obtained with LEWICE3D simulations utilizing a discrete number of drop diameters. It was then compared with the collection efficiency measurement data obtained in the IRT. For the experimental collection efficiency, two ice shape digitization procedures were utilized to extract 2-D chord-wise ice shape profiles, i.e., the Maximum Combined Cross Section or MCCS, and the Minimum Combined Cross Section or MinCCS, at selected span-wise locations from the 3-D scanned ice shapes. The preliminary result showed that the rime ice thickness method can be used to characterize the collection efficiency distribution, for conditions free of ice erosion, in the main ice shape region. However, a high-order statistical processing of the ice scan is needed for estimating the mean ice thickness in areas where feathers are prevalent. From the limited comparison of the experimental and LEWICE3D collection efficiency data in the CRM65 MS model leading edge area, it was shown that the attachment line maximum collection efficiency is reasonably estimated by the best curve-fit correlation in the range of modified inertia parameter tested. A tighter alignment control of the iced and cold clean model scans as well as the model angle of attack are needed to improve the comparison. Further evaluation of this correlation is recommended to assess its applicability for Common Research Model type swept wing icing scaling analysis.

Icing Scaling↗

In-Flight Line-Of-Sight Pointing Performance for the GOES-16 and GOES-17 Spacecraft

The Geostationary Operational Environmental Satellite-R program (GOES-R) has launched two of the next generation geostationary weather satellites, both of which are now fully operational. GOES-16 launched in November 2016, and GOES-17 launched in March 2017. In this paper, we present the pointing and pointing stability results of the two spacecraft, with specific focus on aspects of the design related to mitigating jitter. The flight instrument suite includes 6 seismic accelerometers sampled at approximately 2 kilohertz, allowing in-flight verification of pointing stability and comparison back to simulation predictions. This paper compares the observed flight results with the simulation predictions for acceleration and shock response spectrum (SRS) for various operational scenarios and instrument observation modes. Passive isolation of both the reaction wheels and the payload deck have proved to be effective in reducing jitter responses. Active Vibration Damping (AVD) of flexible-body modes attenuates the low frequency motion of the vehicle appendages, improving the low-frequency pointing performance. Knowledge of the instrument scan mirror motion is fed forward to the reaction wheel control, reducing disturbances on the spacecraft bus. Attitude knowledge and rate data are provided to the primary Earth-observing instrument with an accuracy defined by the Integrated Rate Error (IRE) requirements. The data are used to adjust instrument scanning. As we show in this paper, the in-flight performance of the GN&C (Guidance, Navigation and Control) design provides the necessary capabilities to achieve the demanding GOES-R mission objectives while its robustness enabled the simultaneous operation of the Advanced Baseline Imager (ABI) prime and redundant cryocoolers (CCs) to resolve an in-flight cooling anomaly on GOES-17.

Line-of-Sight↗

The problem of spiral galaxies and satellite radio sources

Regions 2-deg x 2-deg in area centered on four spiral galaxies were scanned with the Goldstone 64-m antenna in search of satellite radio sources at 2295 MHz. Four control regions of equal area but free of galaxies brighter than 13th magnitude were also scanned. No significant excess in the number density of sources with flux densities greater than 0.10 Jy relative to the control fields was found. A detailed comparison is made between the results of this program and the results of previous investigators. In particular, attention is directed to the potentially important implications of an investigation by Tovmasyan (1968), who searched a large number of spirals and found evidence that a small percentage of them apparently have radio satellites located up to 20 arcmin from the central galaxy. Fifteen sources selected from Tovmasyan's list of 43 satellite sources were measured. The present results confirm his positions and relative flux densities for each of the sources.

Arp, H.↗

The Microwave Anisotropy Probe (MAP): Guidance, Navigation, and Control Hardware Suite

The Microwave Anisotropy Probe (MAP) was launched June 30, 2001 to create an all-sky map of the Cosmic Microwave Background. The mission's hardware suite included two Lockheed Martin AST-201 star trackers, two Kearfott Two-Axis Rate Assemblies (TARAs) mounted to provide X, Y and redundant Z-axis rates, two Adcole Digital Sun Sensor (DSS) heads sharing one set of electronics, twelve Adcole Coarse Sun Sensor (CSS) eyes, three Ithaco E-sized Reaction Wheel Assemblies (RWAs), and a Propulsion Subsystem that employed eight PRIMEX Rocket Engine Modules (REMs). This hardware has allowed MAP to meet its various Orbit and Attitude Control Requirements, including performing a complex zero-momentum scan, meeting its attitude determination requirements, and maintaining a trajectory that places MAP in a lissajous orbit around the second Sun-Earth Lagrange point (L2) via phasing loops and a lunar gravity assist. Details of MAP's attitude determination, attitude control, and trajectory design are presented separately. This paper will focus on the performance of the hardware components mentioned above, as well as the significant lessons learned through the use of these components. An emphasis will be placed on spacecraft design modifications that were needed to accommodate existing hardware designs into the MAP Observatory design.

Ward, David K.↗

A computer controlled television detector for light, X-rays and particles

A versatile, high resolution, software configurable, two-dimensional intensified vidicon quantum detector system has been developed for multiple research applications. A thin phosphor convertor allows the detection of X-rays below 20 keV and non-relativistic particles in addition to visible light, and a thicker scintillator can be used to detect X-rays up to 100 keV and relativistic particles. Faceplates may be changed to allow any active area from 1 to 40 mm square, and active areas up to 200 mm square are possible. The image is integrated in a digital memory on any software specified array size up to 4000 x 4000. The array size is selected to match the spatial resolution, which ranges from 10 to 100 microns depending on the operating mode, the active area, and the photon or particle energy. All scan and data acquisition parameters are under software control to allow optimal data collection for each application.

Kalata, K.↗

A segmented mirror antenna for radiometers

An antenna is designed for the radiometer application of the planned NASA Earth Science Geostationary Platforms in the 1990's. The antenna consists of two parts: a regular parabolic dish of 5 meters in diameter which converts the radiation from feeds into a collimated beam, and a movable mirror that redirects the beam to a prescribed scan direction. The mirror is composed of 28 segmented planar conducting plates, mostly one square meter in size. The secondary pattern of the antenna was analyzed based on a physical optics analysis. For frequencies between 50 and 230 GHz, and for a scan range of + or -8 deg (270 beamwidths scan at 230 GHz), the worst calculated beam efficiency is 95 percent. To cover such a wide frequency and scan range, each of the 28 plates is individually controlled for a tilting less than 4 deg, and for a sliding less than 0.5 cm. The sliding is done at discrete steps. At 230 GHz, a step size of 2 mil is sufficient. The plate positions must be reset for each frequency and for each scan direction. Once the position is set, the frequency bandwidth of the antenna is very narrow.

Lee, S. W.↗

Range Imaging without Moving Parts

Range-imaging instruments of a type now under development are intended to generate the equivalent of three-dimensional images from measurements of the round-trip times of flight of laser pulses along known directions. These instruments could also provide information on characteristics of targets, including roughnesses and reflectivities of surfaces and optical densities of such semi-solid objects as trees and clouds. Unlike in prior range-imaging instruments based on times of flight along known directions, there would be no moving parts; aiming of the laser beams along the known directions would not be accomplished by mechanical scanning of mirrors, prisms, or other optical components. Instead, aiming would be accomplished by using solid-state devices to switch input and output beams along different fiber-optic paths. Because of the lack of moving parts, these instruments could be extraordinarily reliable, rugged, and long-lasting. An instrument of this type would include an optical transmitter that would send out a laser pulse along a chosen direction to a target. An optical receiver coaligned with the transmitter would measure the temporally varying intensity of laser light reflected from the target to determine the distance and surface characteristics of the target. The transmitter would be a combination of devices for generating precise directional laser illumination. It would include a pulsed laser, the output of which would be coupled into a fiber-optic cable with a fan-out and solid-state optical switches that would enable switching of the laser beam onto one or more optical fibers terminated at known locations in an array on a face at the focal plane of a telescope. The array would be imaged by the telescope onto the target space. The receiver optical system could share the aforementioned telescope with the transmitter or could include a separate telescope aimed in the same direction as that of the transmitting telescope. In either case, light reflected from the target would be focused by the receiver optical system onto an array of optical fibers matching the array in the transmitter. These optical fibers would couple the received light to one or more photodetector( s). Optionally, the receiver could include solid-state optical switches for choosing which optical fiber(s) would couple light to the photodetector(s). This instrument architecture is flexible and can be optimized for a wide variety of applications and levels of performance. For example, it is scalable to any number of pixels and pixel resolutions and is compatible with a variety of ranging and photodetection methodologies, including, for example, ranging by use of modulated (including pulsed and encoded) light signals. The use of fixed arrays of optical fibers to generate controlled illumination patterns would eliminate the mechanical complexity and much of the bulk of optomechanical scanning assemblies. Furthermore, digital control of the selection of the fiber-optic pathways for the transmitted beams could afford capabilities not seen in previous three-dimensional range-imaging systems. Instruments of this type could be specialized for use as, for example, proximity detectors, three-dimensional robotic vision systems, airborne terrain-mapping systems, and inspection systems.

Blair, J. Bryan↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Tuneable Auxiliary Control Mechanisms For RUM Actuators

Tuneable auxiliary control mechanisms for rotating unbalanced-mass (RUM) actuators used to maximize scan amplitudes and/or minimize power consumption during changing conditions. This type of mechanism more sophisticated version of type of mechanism described in "Auxiliary Control Mechanisms for RUM Actuators" (MFS-28817). Torsional stiffness of torsionally flexible coupling made adjustable on command. Torsionally flexible coupling in tuneable version of auxiliary control mechanism adjustable by use of stepping-motor-driven worm-gear mechanism that varies bending length of flexible blade.

Polites, Michael E.↗