Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Probing the optical properties and toxicological profile of zinc tungstate nanorods

Zinc tungstate is a semiconductor known for its favorable photocatalytic, photoluminescence, and scintillation properties, coupled with its relatively low cost, reduced toxicity, and high stability in biological and catalytic environments. In particular, zinc tungstate evinces scintillation properties, namely the ability to emit visible light upon absorption of energetic radiation such as x rays, which has led to applications not only as radiation detectors but also for biomedical applications involving the delivery of optical light to deep tissue, such as photodynamic therapy and optogenetics. Here, we report on the synthesis of zinc tungstate nanorods generated via an optimized but facile method, which allows for synthetic control over the aspect ratio of the as-synthesized anisotropic motifs via rational variation of the solution pH. Additionally, we investigate the effect of aspect ratio on their resulting photoluminescent and radioluminescent properties. We further demonstrate the potential of these zinc tungstate nanorods for biomedical applications, such as photodynamic therapy for cancer treatment, by analyzing their toxicological profile within cell lines and neurons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Source shape estimation for neutron imaging systems using convolutional neural networks

Neutron imaging systems are important diagnostic tools for characterizing the physics of inertial confinement fusion reactions at the National Ignition Facility (NIF). In particular, neutron images give diagnostic information on the size, symmetry, and shape of the fusion hot spot and surrounding cold fuel. Images are formed via collection of neutron flux from the source using a system of aperture arrays and scintillator-based detectors. Currently, reconstruction of fusion source geometry from the collected neutron images is accomplished by solving a computationally intensive maximum likelihood estimation problem via expectation maximization. In contrast, it is often useful to have simple representations of the overall source geometry that can be computed quickly. In this work, we develop convolutional neural networks (CNNs) to reconstruct the outer contours of simple source geometries. We compare the performance of the CNN for penumbral and pinhole data and provide experimental demonstrations of our methods on both non-noisy and noisy data.

Machine learning, neutron imaging, source reconstr↗

Observation of d(t,n) α Neutrons Following d(d,p)t Reactions in a Deuterium Gas Cell: An Attempt to Repeat Ruhlig’s 1938 Observation of Secondary Reactions

In order to benchmark methods used to calculate reaction-in-flight fusion reactions in inertial confinement fusion and address issues related to the first claimed observation of d(t,n)α reactions in 1938, secondary d(t,n)α reactions have been observed following d(d,p)t reactions in deuterium gas. A pulsed 200-nA, 2.2-MeV deuterium beam from the Triangle Universities Nuclear Laboratory FN tandem accelerator was injected into a cylindrical multiatmosphere deuterium gas target. The incident beam traversed along the target cylinder’s 3-cm symmetry axis after its passage through a Havar entrance foil. Two different Havar foil thicknesses were used to obtain 1.5- and 0.6-MeV deuteron beams entering the deuterium cell. The cylinder’s radius was 2 cm to allow for d(d,p)t tritons emitted perpendicular to the beam to range out in the deuterium gas. The neutron emission from the cell was observed via its time of flight to a liquid scintillator placed at various angles to the beam direction, at a distance of 243 cm. Pulse-shape-discrimination techniques were used to separate neutron and gamma-ray signals seen in the liquid scintillator. The observed probability of ~2 × 10 –4 for inducing secondary d(t,n)α fusion in the gas cell per d(d,p)t reaction is consistent with theoretical expectations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of fusion alphas interaction with RF waves in D-T plasma at JET

This work studies the influence of RF waves in ICRH range of frequency on fusion alphas during the recent JET D-T campaign. Fusion alphas from D-T reactions are born with energies of about 3.5MeV and therefore have significant Doppler shift enabling synergistic interaction between them and RF waves at broad range of frequencies including the ones foreseen for future fusion machines ITER and SPARC. Resonant interaction between RF waves and alphas, also called synergistic effects, will modify the alpha distribution and ultimately will have an impact on alpha orbit losses and heating. Data from JET 3.43T/2.3MA pulses based on the hybrid scenario during the DTE2 campaign were used for the analysis in this study. The impact of synergistic effects on alpha orbit losses and alpha heating is assessed. Conclusions are based on analysis of experimental data for fast alphas losses, i.e. measurements from neutral particle analyser, fast ion losses scintillator detector, Faraday cups, and TRANSP simulations. Experimental data and TRANSP analysis indicate that there are indeed changes in the alphas' distribution function due to interaction with RF waves. Data from the scintillator detector and the Faraday cups were compared for pulses with and without ICRH power and versus cases with enhanced alpha losses due to MHD activities. The trends from these diagnostics consistently show no additional alpha losses due to interaction with RF waves. TRANSP predictions for the impact of the synergistic effects on alpha heating show up to 42% increase in alpha electron heating and up to 25% increase in alpha ion heating. These effects however become negligibly small, less than 1%, when alpha heating is compared to the total auxiliary hearting power in the investigated JET pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Upgrade and characterization of the fast-channels of Imaging Neutral Particle Analyzers in the DIII-D tokamak

This publication presents the characterization of the recently upgraded fast (MHz) channels of the DIII-D Imaging Neutral Particle Analyzers. The new system allows for a phase space resolution of < 10 keV and < 10 cm. The main source of noise is due to the background radiation (neutrons and gammas) present in the diagnostic lab during experiments, which can hit the photomultipliers and generate large spikes in signal. Good linear correlations (r 2 > 0.9) are found between the average rate of noise spikes in the fast channels and the average neutron rate. Additional noise is caused by the scintillation of the optical fibers used to guide the signal to the acquisition system, which is induced by neutron and gamma impacts. A correlation factor r 2 > 0.6 between the baseline noise caused by this scintillation and the signals in the neutron diagnostic was found. Possible mitigation strategies, such as the use of shielding and filters, are discussed. These allow to reduce the noise spike rate by an order of magnitude and the noise baseline by a factor 4. Despite the noise, it is shown that the upgraded fast channels provide enough signal-to-noise ratio to observe coherent fluctuations of the energetic particle population.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity of nEXO to 136 Xe charged-current interactions: Background-free searches for solar neutrinos and fermionic dark matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, 𝜈 𝑒 + 136 Xe → 136 Cs*+𝑒 − , as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of 136 Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo simulation of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of 10 −9 , enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of neutrinos from the carbon-nitrogen-oxygen cycle with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement toward addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the 7 Be neutrinos with a precision of 𝜎 ≤ 1.5 keV and could determine the survival probability of 7 Be and pep solar 𝜈𝑒 with precision comparable to the state of the art. These quantities are sensitive to the Sun’s core temperature and to nonstandard neutrino interactions, respectively. Here, the strong background suppression would allow nEXO to search for charged-current interactions of fermionic dark matter in the mass range 𝑚 𝜒 = 0.668–7 MeV with a sensitivity up to three orders of magnitude better than current limits.

47 OTHER INSTRUMENTATION↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Measurement of fragment-correlated γ-ray emission from 252 Cf(sf)

This paper presents recent experimental results on the yield of prompt fission γ rays from the spontaneous fission of 252 Cf. We use an ionization chamber to tag fission events and measure the masses and kinetic energies of the fission fragments and trans-stilbene organic scintillators to measure the neutrons and γ rays emitted by the fission fragments. The combination of the ionization chamber and trans-stilbene scintillators allows us to determine the properties of neutrons and γ rays in coincidence with the fragments. The yield of γ rays is known to be influenced by the angular momenta (AM) of the fission fragments. We present experimental evidence indicating that the total γ-ray multiplicity, i.e., the sum of both fragments' emission, saturates at sufficiently high internal fragment excitation energies. We also observe distinct behaviors for the yield of γ rays from the light and heavy fragments, which for certain mass and total kinetic energy (TKE) regions are weakly or anticorrelated, indicating the presence of complex AM generation modes. We also observed a mass- and TKE-dependent anisotropy of the γ rays, which challenges and expands on the conventional notion that the fragments' AM are always aligned perpendicularly to the fission axis. Furthermore, the dependence of the anisotropy on mass and TKE indicates a dependence of these properties on the specific fission channels, thus providing an insight into the deformations and dynamics in fission and their connection with experimentally observable quantities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift dis tance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high and low-energy events. Using point-like energy deposits from 83m Kr calibration electron captures (E ~ 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias < 1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E ≥ 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q ββ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial measurement of reactor antineutrino oscillation at SNO+

The SNO+ collaboration reports its first spectral analysis of long-baseline reactor antineutrino oscillation using 114 tonne-years of data. Fitting the neutrino oscillation probability to the observed energy spectrum yields constraints on the neutrino mass-squared difference Δ$m^2_{21}$. In the ranges allowed by previous measurements, the best-fit Δ$m^2_{21}$ is ($8.85^{+1.10}_{-1.33}$) × 10 -5 eV 2 . This measurement is continuing in the next phases of SNO+ and is expected to surpass the present global precision on Δ$m^2_{21}$ with about three years of data. In the following, we first describe the configuration of the SNO+ detector when it was partially filled with scintillator, and a characterization of the detector response using intrinsic radioactivity. Next, we detail the event selection and expectations for reactor IBDs and (α, n) reactions. Then, we present the results of an energy spectrum analysis using 114 tonne-years of data. We conclude with prospects of future results from the SNO+ detector, which has been operating fully-filled with 780 tonnes of scintillator

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Liquid Argon Time-Projection Chamber Readouts

Liquid argon time-projection chambers (LArTPCs) have become a prominent tool for experiments in particle physics. Recent years have yielded significant advances in the techniques used to capture the signals generated by these cryogenic detectors. This article summarizes these novel developments for detection of ionization electrons and scintillation photons in LArTPCs. New methods to capture ionization signals address the challenges of scaling traditional techniques to the large scales necessary for future experiments. Pixelated readouts improve signal fidelity and expand the applicability of LArTPCs to higher-rate environments. Methods that leverage amplification in argon enable measurements in the keV regime and below. Techniques to enhance collection of argon scintillation photons improve calorimetry and expand the physics program for very large detectors. Future efforts aim to demonstrate systems for the combined detection of both electrons and photons.

43 PARTICLE ACCELERATORS↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗