Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Local Helioseismology: A New Window into the Sun

In recent years the focus of helioseismology has shifted from the classical measurements of global properties using normal mode frequencies to possibly a more difficult problem of measuring the three-dimensional, time-dependent structure of the solar interior, now called local helioseismology. Problems to be studed include the subsurface structure of observed surface features such as sunspots, convective flow patterns, and the magnetic field of the 1 1-year sunspot cycle. A variety of techniques have been developed to attack these problems, including a 'local' normal mode method, a method of measuring travel times between &stant locations, and a method for holographically reconstructing the acoustic signal in the solar interior. Recent results from the field will be reviewed.

Duvall, Thomas↗

Sampling Theorem in Terms of the Bandwidth and Sampling Interval

An approach has been developed for interpolating non-uniformly sampled data, with applications in signal and image reconstruction. This innovation generalizes the Whittaker-Shannon sampling theorem by emphasizing two assumptions explicitly (definition of a band-limited function and construction by periodic extension). The Whittaker- Shannon sampling theorem is thus expressed in terms of two fundamental length scales that are derived from these assumptions. The result is more general than what is usually reported, and contains the Whittaker- Shannon form as a special case corresponding to Nyquist-sampled data. The approach also shows that the preferred basis set for interpolation is found by varying the frequency component of the basis functions in an optimal way.

Dean, Bruce H.↗

Acoustic Mode Decomposition in Rectangular Ducts with Sheared Flow

The performance of new acoustic liner concepts are, in general, characterized and assessed in grazing flow rigs early in the development cycle. These test rigs expose an acoustic liner sample, installed on the side wall of the duct, to a grazing flow and incident acoustic field. The process to characterize these liners involves educing the impedance on the wall where the sample is installed and examining the acoustic power attenuation. Standard approaches to computing impedance or power attenuation generally consider only the effects of a 2D shear flow or uniform flow, on the acoustic field. In this study, the objective is to incorporate 3D shear flow effects in the analysis of acoustic mode attenuation in a rectangular duct flow rig. A modal analysis of microphone measurements obtained on the side walls of the duct upstream and downstream of the test section of the rig is developed. A Galerkin projection of the Pridmore-Brown equation is performed with Chebyshev basis functions in order to incorporate the effects of the Mach number profile on the computation of the axial wavenumber of each mode. Measurements of the Mach number profile are obtained in the test rig and used as input to compute the modes. Comparisons made between the sound field computed with traditional convective Helmholtz modes and the new procedure using Pridmore-Brown modes indicate that the computed acoustic field using Pridmore-Brown modes more accurately reconstructs the acoustic signal at each microphone in the array. The mode structure of the lowest-order mode is shown to be significantly impacted by shear flow refraction effects, and higher-order mode structures are also affected at higher frequencies and centerline Mach number. An assessment of the acoustic mode attenuation for two acoustic liner samples demonstrates that the computed mode amplitudes for both the traditional and new approach are in agreement for the lowest-order mode, but discrepancies arise when higher-order modes are the dominant component of the acoustic field.

Duct acoustics↗

Acoustic Mode Decomposition in Rectangular Ducts with Sheared Flow

The performance of new acoustic liner concepts are, in general, characterized and assessed in grazing flow rigs early in the development cycle. These test rigs expose an acoustic liner sample, installed on the side wall of the duct, to a grazing flow and incident acoustic field. The process to characterize these liners involves educing the impedance on the wall where the sample is installed and examining the acoustic power attenuation. Standard approaches to computing impedance or power attenuation generally consider only the effects of a 2D shear flow or uniform flow, on the acoustic field. In this study, the objective is to incorporate 3D shear flow effects in the analysis of acoustic mode attenuation in a rectangular duct flow rig. A modal analysis of microphone measurements obtained on the side walls of the duct upstream and downstream of the test section of the rig is developed. A Galerkin projection of the Pridmore-Brown equation is performed with Chebyshev basis functions in order to incorporate the effects of the Mach number profile on the computation of the axial wavenumber of each mode. Measurements of the Mach number profile are obtained in the test rig and used as input to compute the modes. Comparisons made between the sound field computed with traditional convective Helmholtz modes and the new procedure using Pridmore-Brown modes indicate that the computed acoustic field using Pridmore-Brown modes more accurately reconstruct the acoustic signals at each microphone in the array. The mode structure of the lowest order mode is shown to be significantly impacted by shear flow refraction effects, and higher order mode structures are also effected at higher frequencies and centerline Mach number. An assessment of the acoustic mode attenuation for two acoustic liner samples demonstrates that the computed mode amplitudes for both the traditional and new approach are in agreement for the lowest order mode, but discrepancies arise when higher order modes are the dominant component of the acoustic field.

Duct acoustics↗

Total variation vs L1 regularization: a comparison of compressive sensing optimization methods for chemical detection

One of the fundamental assumptions of compressive sensing (CS) is that a signal can be reconstructed from a small number of samples by solving an optimization problem with the appropriate regularization term. Two standard regularization terms are the L1 norm and the total variation (TV) norm. We present a comparison of CS reconstruction results based on these two approaches in the context of chemical detection, and we demonstrate that optimization based on the L1 norm outperforms optimization based on the TV norm. Our comparison is driven by CS sampling, reconstruction, and chemical detection in two real-world datasets: the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset and the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset. Both datasets contain the release of a chemical simulant such as glacial acetic acid, triethyl phosphate, and sulfur hexafluoride. For chemical detection we use the adaptive coherence estimator (ACE) and bulk coherence, and we propose algorithmic ACE thresholds to define the presence or absence of a chemical of interest in both un-compressed data cubes and reconstructed data cubes. The un-compressed data cubes provide an approximate ground truth. We demonstrate that optimization based on either the L1 norm or TV norm results in successful chemical detection at a compression rate of 90%, but we show that L1 optimization is preferable. We present quantitative comparisons of chemical detection on reconstructions from the two methods, with an emphasis on the number of pixels with an ACE value above the threshold.

Hyperspectral imagery, L1-norm, total variation, A↗

Search for 2p2h Interactions in the NOνA Near Detector

The physics of 2p2h interactions and their contribution to the NO$\nu$A near detector data are not fully understood. This study attempts to shed some light on these interactions and the accuracy of the models used to simulate them through a search for a specific 2p2h interaction in the NO$\nu$A near detector. By performing an event selection algorithm based on particle identifier algorithms run over reconstructed data, a signal region is created to minimize the background while maximizing the number of 2p2h events where a muon neutrino interacts with a neutron and a proton coupled by a meson exchange current and produces two protons and one muon. In the signal region, separation is found between the signal events and the background in plots of the angles between the protons and the muon. Although a full statistical analysis is not completed in this study, comparing the angle plots for simulation and data shows that the model used to simulate the events reasonably approximates reality and that the near detector data likely includes signal events. Signal events are also identified in event displays, further indicating that there is some contribution of the signal to the overall NO$\nu$A near detector data.

Gable, Kyle↗

Computational optical physical unclonable function

A system or method for encryption of data includes a light source, a random optical element and a light detection element. The light source is arranged to transmit an input data signal to the random optical element. The light source is incident on the random optical element such that the input data signal is randomly scattered by the random optical element to generate an image at on the detector disposed at an output of the random optical element. The image received by the detector is applied to a compressive sensing algorithm to generate a transfer function. The transfer function defines a relationship between the input data signal and the image to enable estimation and reconstruction of the input data signal.

97 MATHEMATICS AND COMPUTING↗

Computational optical physical unclonable function

A system or method for encryption of data includes a light source, a random optical element and a light detection element. The light source is arranged to transmit an input data signal to the random optical element. The light source is incident on the random optical element such that the input data signal is randomly scattered by the random optical element to generate an image at on the detector disposed at an output of the random optical element. The image received by the detector is applied to a compressive sensing algorithm to generate a transfer function. The transfer function defines a relationship between the input data signal and the image to enable estimation and reconstruction of the input data signal.

Birch, Gabriel Carlisle↗

Evaluation of Magnetic Diagnostics for MHD Equilibrium Reconstruction of LHD Discharges

Equilibrium reconstruction is the process of determining the set of parameters of an MHD equilibrium that minimize the difference between expected and experimentally observed signals. This is routinely performed in axisymmetric devices, such as tokamaks, and the reconstructed equilibrium solution is then the basis for analysis of stability and transport properties. The V3FIT code [1] has been developed to perform equilibrium reconstruction in cases where axisymmetry cannot be assumed, such as in stellarators. The present work is focused on using V3FIT to analyze plasmas in the Large Helical Device (LHD) [2], a superconducting, heliotron type device with over 25 MW of heating power that is capable of achieving both high-beta ({approx}5%) and high density (>1 x 10{sup 21}/m{sup 3}). This high performance as well as the ability to drive tens of kiloamperes of toroidal plasma current leads to deviations in the equilibrium state from the vacuum flux surfaces. This initial study examines the effectiveness of using magnetic diagnostics as the observed signals in reconstructing experimental plasma parameters for LHD discharges. V3FIT uses the VMEC [3] 3D equilibrium solver to calculate an initial equilibrium solution with closed, nested flux surfaces based on user specified plasma parameters. This equilibrium solution is then used to calculate the expected signals for specified diagnostics. The differences between these expected signal values and the observed values provides a starting {chi}{sup 2} value. V3FIT then varies all of the fit parameters independently, calculating a new equilibrium and corresponding {chi}{sup 2} for each variation. A quasi-Newton algorithm [1] is used to find the path in parameter space that leads to a minimum in {chi}{sup 2}. Effective diagnostic signals must vary in a predictable manner with the variations of the plasma parameters and this signal variation must be of sufficient amplitude to be resolved from the signal noise. Signal effectiveness can be defined for a specific signal and specific reconstruction parameter as the dimensionless fractional reduction in the posterior parameter variance with respect to the signal variance. Here, {sigma}{sub i}{sup sig} is the variance of the ith signal and {sigma}{sub j}{sup param} param is the posterior variance of the jth fit parameter. The sum of all signal effectiveness values for a given reconstruction parameter is normalized to one. This quantity will be used to determine signal effectiveness for various reconstruction cases. The next section will examine the variation of the expected signals with changes in plasma pressure and the following section will show results for reconstructing model plasmas using these signals.

30 DIRECT ENERGY CONVERSION↗

Non-Uniform Contrast and Noise Correction for Coded Source Neutron Imaging

Since the first application of neutron radiography in the 1930s, the field of neutron radiography has matured enough to develop several applications. However, advances in the technology are far from concluded. In general, the resolution of scintillator-based detection systems is limited to the $10\mu m$ range, and the relatively low neutron count rate of neutron sources compared to other illumination sources restricts time resolved measurement. One path toward improved resolution is the use of magnification; however, to date neutron optics are inefficient, expensive, and difficult to develop. There is a clear demand for cost-effective scintillator-based neutron imaging systems that achieve resolutions of $1 \mu m$ or less. Such imaging system would dramatically extend the application of neutron imaging. For such purposes a coded source imaging system is under development. The current challenge is to reduce artifacts in the reconstructed coded source images. Artifacts are generated by non-uniform illumination of the source, gamma rays, dark current at the imaging sensor, and system noise from the reconstruction kernel. In this paper, we describe how to pre-process the coded signal to reduce noise and non-uniform illumination, and how to reconstruct the coded signal with three reconstruction methods correlation, maximum likelihood estimation, and algebraic reconstruction technique. We illustrates our results with experimental examples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the B⁰→π⁻l⁺ν and B⁺→η (') l⁺ν branching fractions, the B⁰→π⁻l⁺ν and B⁺→ηl⁺ν form-factor shapes, and determination of |V ub |

We report the results of a study of the exclusive charmless semileptonic decays, B⁺→η (') l⁺ν and B⁰→π⁻l⁺ν, undertaken with approximately 464×10⁶ BB¯¯ pairs collected at the Υ(4S) resonance with the BABAR detector. The analysis uses events in which the signal B decays are reconstructed with a loose neutrino reconstruction technique. We obtain partial branching fractions for B⁺→ηl⁺ν and B⁰→π⁻l⁺ν decays in three and 12 bins of q², respectively, from which we extract the f+(q²) form-factor shapes and the total branching fractions B(B⁺→ηl⁺ν)=(0.36±0.05 stat ±0.04 syst )×10⁻⁴ and B(B⁰→π⁻l⁺ν)=(1.42±0.05 stat ±0.07 syst )×10⁻⁴. We also measure B(B+→η'l⁺ν)=(0.24±0.08 stat ±0.03 syst )×10⁻⁴. We obtain values for the magnitude of the CKM matrix element |Vub| using three different QCD calculations.

del Amo Sanchez, P.↗

Validating the simulation of beam-ion charge exchange in MAST Upgrade

Abstract Simulation of the impact of charge-exchange (CX) reactions on beam ions in the Mega Amp Spherical Tokamak (MAST) Upgrade was compared to measurements carried out with a fission chamber (neutron fluxes) and a fast ion deuterium-alpha (FIDA) diagnostic. A simple model was developed to reconstruct the outer-midplane neutral density based on measurements of deuterium-alpha emission from edge neutrals, and on Thomson scattering measurements of electron density and temperature. The main computational tools used were the ASCOT orbit-following code and the FIDASIM code for producing synthetic FIDA signals. The neutral density reconstruction agrees qualitatively with SOLPS-ITER modelling and yields a synthetic passive FIDA signal that is consistent with measurement. When CX losses of beam ions are accounted for, predicted neutron emission rates are quantitatively more consistent with measurement. It was necessary to account for CX losses of beam ions in simulations to reproduce the measured passive FIDA signal quantitatively and qualitatively. The results suggest that the neutral density reconstruction is a good approximation, that CX with edge neutrals causes significant beam-ion losses in MAST Upgrade, typically 20% of beam power, and that the ASCOT fast-ion CX model can be used to accurately predict the redistribution and loss of beam ions due to CX.

Physics↗

Coherent optical array receiver experiment : design, implementation and BER performance of a multichannel coherent optical receiver for PPM signals under atmospheric turbulence

The performance of a coherent free-space optical communication system operating in the presence of turbulence is investigated. Maximum Likelihood Detection techniques are employed to optimally detect Pulse Position Modulated signals with a focal-plane detector array, and reconstruct the turbulence-degraded signals. The experimental demonstration of this project and results may be divided in three parts; two of which have already been explained in previous publications (1,2). This latest paper shows the final experimental results, including investigation of performance of the Coherent Optical Receiver Experiment (CORE) performed at the laboratory facilities at JPL. Bit Error Rate (BER) is presented for single and multichannel optical receivers, where quasi-shot noise limited performance is achieved, under simulated turbulence conditions using non-coherent post-detection processing techniques.

Hassibi, Babak↗

Selective-diffusion regularization for enhancement of microcalcifications in digital breast tomosynthesis reconstruction

Purpose: Digital breast tomosynthesis (DBT) has been shown to improve mass detection. Detection of microcalcifications is more challenging because of the large breast volume to be searched for subtle signals. The simultaneous algebraic reconstruction technique (SART) was found to provide good image quality for DBT, but the image noise is amplified with an increasing number of iterations. In this study, the authors developed a selective-diffusion (SD) method for noise regularization with SART to improve the contrast-to-noise ratio (CNR) of microcalcifications in the DBT slices for human or machine detection. Methods: The SD method regularizes SART reconstruction during updating with each projection view. Potential microcalcifications are differentiated from the noisy background by estimating the local gradient information. Different degrees of regularization are applied to the signal or noise classes, such that the microcalcifications will be enhanced while the noise is suppressed. The new SD method was compared to several current methods, including the quadratic Laplacian (QL) method, the total variation (TV) method, and the nonconvex total p-variation (TpV) method for noise regularization with SART. A GE GEN2 prototype DBT system with a stationary digital detector was used for the acquisition of DBT scans at 21 angles in 3 deg. increments over a {+-}30 deg. range. The reconstruction image quality without regularization and that with the different regularization methods were compared using the DBT scans of an American College of Radiology phantom and a human subject. The CNR and the full width at half maximum (FWHM) of the line profiles of microcalcifications within the in-focus DBT slices were used as image quality measures. Results: For the comparison of large microcalcifications in the DBT data of the subject, the SD method resulted in comparable CNR to the nonconvex TpV method. Both of them performed better than the other two methods. For subtle microcalcifications, the SD method was superior to other methods in terms of CNR. In both the subject and phantom DBT data, for large microcalcifications, the FWHM of the SD method was comparable to that without regularization, which was wider than that of the TV type methods. For subtle microcalcifications, the SD method had comparable FWHM values to the TV type methods. All three regularization methods were superior to the QL method in terms of FWHM. Conclusions: The SART regularized by the selective-diffusion method enhanced the CNR and preserved the sharpness of microcalcifications. In comparison with three existing regularization methods, the selective-diffusion regularization was superior to the other methods for subtle microcalcifications.

60 APPLIED LIFE SCIENCES↗

Dynamic compressed sensing for real-time tomographic reconstruction

Electron tomography has achieved higher resolution and quality at reduced doses with recent advances in compressed sensing. Compressed sensing (CS) exploits the inherent sparse signal structure to efficiently reconstruct three-dimensional (3D) volumes at the nanoscale from undersampled measurements. However, the process bottlenecks 3D reconstruction with computation times that run from hours to days. Here we demonstrate a framework for dynamic compressed sensing that produces a 3D specimen structure that updates in real-time as new specimen projections are collected. Researchers can begin interpreting 3D specimens as data is collected to facilitate high-throughput and interactive analysis. Using scanning transmission electron microscopy (STEM), we show that dynamic compressed sensing accelerates the convergence speed by ~3-fold while also reducing its error by 27% for a Au/SrTiO 3 nanoparticle specimen. Before a tomography experiment is completed, the 3D tomogram has interpretable structure within ~33% of completion and fine details are visible as early as ~66%. Upon completion of an experiment, a high-fidelity 3D visualization is produced without further delay. Additionally, we report reconstruction parameters that tune data fidelity can be manipulated throughout the computation without re-running the entire process.

47 OTHER INSTRUMENTATION↗

Search for B → h ( * ) ν ν ¯ with the full Belle Υ ( 4 S ) data sample

This report is of a search for the rare decays B → h ( * ) ν ν ¯ , where h ( * ) stands for K + , K S 0 , K * + , K * 0 , π + , π 0 , ρ + , ρ 0 and Φ . The results are obtained from a 711 fb - 1 data sample that contains 772 × 10 6 B B ¯ pairs collected at the Υ ( 4 S ) resonance with the Belle detector at the KEKB e + e - collider. We search for signal candidates by fully reconstructing a hadronic decay of the accompanying B meson and requiring a single h ( * ) meson left on the signal side. No significant signal is observed and we set upper limits on the branching fractions at 90% confidence level. The measurements of B + → K * + ν ν ¯ , B + → π + ν ν ¯ , B 0 → π 0 ν ν ¯ and B 0 → ρ 0 ν ν ¯ provide the world’s currently most restrictive limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lensless X-Ray Nanoimaging: Revolutions and opportunities

Lensless x-ray nanoimaging is providing 3D views of a wide range of materials with a spatial resolution better than 20 nanometers. These advances are enabled in part by dramatic gains in coherent x-ray flux, but they also rely on advances in signal processing to obtain images from coherent diffraction data. Here, we outline the various imaging approaches, the associated reconstruction methods, and highlight opportunities for future advances.

42 ENGINEERING↗

Improving topological cluster reconstruction using calorimeter cell timing in ATLAS

Clusters of topologically connected calorimeter cells around cells with large absolute signal-to-noise ratio (topo-clusters) are the basis for calorimeter signal recon struction in the ATLAS experiment. Topological cell clus tering has proven performant in LHC Runs 1 and 2. It is, however, susceptible to out-of-time pile-up of signals from soft collisions outside the 25 ns proton-bunch-crossing window associated with the event’s hard collision. To reduce this effect, a calorimeter-cell timing criterion was added to the signal-to-noise ratio requirement in the clustering algorithm. Multiple versions of this criterion were tested by reconstructing hadronic signals in simulated events and Run 2 ATLAS data. The preferred version is found to reduce the out-of-time pile-up jet multiplicity by ~50% for jet p T ~ 20 GeV and by ~80% for jet p T ≳ 50 GeV, while not disrupting the reconstruction of hadronic signals of interest, and improving the jet energy resolution by up to 5% for 20 < p T < 30 GeV. Pile-up is also suppressed for other physics objects based on topo-clusters (electrons, photons, τ-leptons), reducing the overall event size on disk by about 6% in early Run 3 pile up conditions. Offline reconstruction for Run 3 includes the timing requirement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗