Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Novel indium phosphide charged particle detector characterization with a 120 GeV proton beam

Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-intrinsic-metal structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accelerator Laboratory. In addition to its simplistic design and fabrication process, the indium phosphide particle detector showed a very fast response time of hundreds of picoseconds for the 120 GeV protons, which are comparable to the ultra-fast silicon detectors. This fast-timing response is attributed to the high electron mobility of indium phosphide. Such material properties can be leveraged to build novel detectors with superlative performance.

47 OTHER INSTRUMENTATION↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE $v$ NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. Here, in this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm 2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68 ± 0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.

Chang, C. L. [Argonne National Laboratory 1 , 9700↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position sensitive device technologies for particle physics

Here, I will give a brief overview of the use of position sensitive devices for particle physics. I will focus on silicon-based systems only. In addition to the depiction of a suite of recently designed, built, and operated detectors I will also introduce planned near term additions. I will conclude with a brief outlook regarding challenges for silicon detector applications for future colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

TexAT detector upgrade for 14 O($α$, $p$) 17 F cross section measurement

A direct cross-section measurement of the 14 O($α$, $p$) 17 F reaction is important to understand the light curves of x-ray bursts. The measurement will be performed using the Texas Active Target TPC version 2 (TexAT_v2). The TexAT_v2 aims at measuring lower energy protons from the reaction than the original TexAT. Newly developed silicon and CsI(Tl) detector arrays are added at the left, right and bottom of a modified field cage to increase its detection efficiency. Furthermore, this paper describes the overall specifications and two commissioning experiments performed at Texas A&M University.

14O(α, p)17F↗

Identifying Interaction Location in SuperCDMS Detectors

The Super Cryogenic Dark Matter Search (SuperCDMS) experiment uses silicon and germanium particle detectors operated at temperatures of ∼ 30 mK to search for Weakly Interacting Massive Particles (WIMPs), which are candidate dark matter particles that interact weakly with nuclei in the detectors. In operating these detectors, it is required not only to measure the energy of the interaction between the WIMP and the nuclei, but also to reconstruct where the interaction occurred, as the location can be used to separate background interactions from signal and to correct for variations with the location of the energy response. In this project, we, as a team from the University of Minnesota, aim to address the problem of accurately reconstructing the locations of interactions in the SuperCDMS detectors using machine learning methods. The dataset we provided here includes interactions at thirteen different locations from test data taken at the University of Minnesota. For each interaction, a set of parameters was extracted from the signals from each of the five sensors. These parameters represent information known to be sensitive to interaction location, including the relative timing between pulses in different channels, and features like the pulse shape. The relative amplitudes of the pulses are also relevant but due to instabilities in amplification during the test, this data is not included. The parameters included for each interaction are described in our project document. For more details, feel free to check our Github page: https://fair-umn.github.io/FAIR-UMN-CDMS/

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SuperCDMS Event Reconstruction Using Convolutional Neural Networks [Thesis]

The SuperCDMS experiment uses cryogenic silicon and germanium detectors to search for dark matter candidates such as WIMPs (Weakly Interacting Massive Particles) streaming through the Earth. Collisions in the silicon and germanium crystals are expected to produce phonons whose thermal signatures can be measured. This thesis first describes the integration of a new Signal Distribution Unit (SDU) to the SuperCDMS data acquisition system, which allows for synchronization of multiple detectors and electronic/mechanical noise characterization via accelerometer, antenna, and AC phase measurements. From SuperCDMS detector data it is necessary to reconstruct the energies of the particle events. This thesis explores the use of Convolutional Neural Networks (CNNs) to perform this reconstruction and finds that, although they perform well, changing the noise model breaks the model and requires the neural network to be retrained. In order to mitigate this issue, a new CNN model is proposed which includes the noise Power Spectral Density (PSD) of the data as an additional input to the CNN. While it proves to be effective as a denoising algorithm, it still fails for data with a different noise model. However, including data from multiple PSDs in the neural network training sample allows it to handle data with different types of noise while still maintaining the quality of the reconstruction. Nevertheless, neural networks trained even on multiple PSDs do not robustly handle data taken with PSDs dissimilar to those in the training sample, suggesting that CNNs may need to be retrained whenever the noise environment changes in a significant way.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of the CMS detector for the CERN LHC Run 3

Since the initial data taking of the CERN LHC, the CMSexperiment has undergone substantial upgrades and improvements. Thispaper discusses the CMS detector as it is configured for the thirddata-taking period of the CERN LHC, Run 3, which started in2022. The entire silicon pixel tracking detector was replaced. A newpowering system for the superconducting solenoid was installed. Theelectronics of the hadron calorimeter was upgraded. All the muonelectronic systems were upgraded, and new muon detector stationswere added, including a gas electron multiplier detector. Theprecision proton spectrometer was upgraded. The dedicated luminositydetectors and the beam loss monitor were refurbished. Substantialimprovements to the trigger, data acquisition, software, andcomputing systems were also implemented, including a new hybridCPU/GPU farm for the high-level trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Earth-scattering induced modulation in low-threshold dark matter experiments

Dark matter particles with sufficiently large interactions with ordinary matter can scatter in the Earth before reaching and scattering in a detector. This induces a modulation in the signal rate with a period of one sidereal day. We calculate this modulation for sub-GeV dark matter particles that interact either with a heavy or an ultralight dark-photon mediator and investigate the resulting signal in low-threshold detectors consisting of silicon, xenon, or argon targets. The scattering in the Earth is dominated by dark matter scatters off nuclei, while the signal in the detector is easiest to observe from dark matter scattering off electrons. We investigate the properties of the modulation signal and provide projections of the sensitivity of future experiments. We find that a search for a modulation signal can probe new regions of parameter space near the energy thresholds of current experiments, where the data are typically dominated by backgrounds.

Models for Dark Matter↗

First Limits on Light Dark Matter Interactions in a Low Threshold Two-Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleus interactions in a 1 cm 2 by 1 mm thick (0.233 g) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves an rms baseline energy resolution of 361.5⁢(4) m⁢ eV (statistical error), the best for any athermal phonon detector to date. With an exposure of 0.233 g ×12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 M⁢ eV/c 2 , with the lowest unexplored cross section of 4⁢ × 10 −32 c⁢m 2 at 87 M⁢ eV/c 2 . We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low energy backgrounds that are coupled to individual sensors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photoelectric absorption cross section of silicon near the bandgap from room temperature to sub-Kelvin temperature

The use of cryogenic silicon as a detector medium for dark matter searches is gaining popularity. Many of these searches are highly dependent on the value of the photoelectric absorption cross section of silicon at low temperatures, particularly near the silicon bandgap energy, where the searches are most sensitive to low mass dark matter candidates. While such cross section data have been lacking from the literature, previous dark matter search experiments have attempted to estimate this parameter by extrapolating it from higher temperature data. However, discrepancies in the high temperature data have led to order-of-magnitude differences in the extrapolations. In this paper, we resolve these discrepancies by using a novel technique to make a direct, low temperature measurement of the photoelectric absorption cross section of silicon at energies near the bandgap (1.2 eV–2.8 eV).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗