Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photon sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Vacuum ultraviolet absorption in a hydrogen arcjet

Atomic absorption spectroscopy was utilized to measure the ground state atomic hydrogen number density in the plasma produced in a low power hydrogen arcjet. A microwave driven hydrogen plasma was used as the source of radiation resonant with the vacuum ultraviolet Lyman alpha transition. The suitability of this radiation source is discussed. The optical depth of this transition prevented measurements at locations where the ground state atomic hydrogen number density was larger than 3 x 10 exp 19/cu m. These results indicate that other single-photon optical diagnostic techniques are equally ineffective in locations of higher hydrogen number density unless the spectral line shape of the atomic hydrogen absorbers is known.

Manzella, David H.↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Thermally Activated Circularly Polarized Photoluminescence in a 2D Hybrid Perovskite with Giant Spin Splitting

Circularly polarized light generation and detection are critical for future spin-based technologies that inter-convert circularly polarized photons and electron spins. However, detailed mechanisms in such spin-photon interfaces are often either poorly understood or operate at cryogenic temperatures since typically small energies separating spin-split electronic bands facilitate thermally driven spin depolarization. Recently, several 2D hybrid perovskites with polar achiral cations were theoretically demonstrated to exhibit conduction and valence band spin-splitting energies greatly exceeding room-temperature thermal energy, suggesting their utility as spin-photon interfaces with practical operating temperatures. Here, a strong "spin memory" effect is reported in such a polar achiral layered perovskite that enables large room-temperature circularly polarized emission anisotropy following excitation with circularly polarized light. The polarization anisotropy depends strongly on temperature (thermally activated), excitation energy, and crystal orientation with respect to the excitation source. Temperature-dependent photoconductance measurements reveal similar thermally activated carrier generation. These observations suggest a mechanism whereby giant in-plane splitting of single-particle levels protects spin-polarization of photogenerated electrons and holes before recombination. Although polarized light emission is explored in greater detail in chiral perovskites, these results reveal that even without chirality, large spin memory in polar achiral perovskites can enable spin-photon interfaces that operate at elevated temperatures.

14 SOLAR ENERGY↗

Quantum Electrodynamics Coupled-Cluster at Scale: High-Performance Implementation for Complex Systems

Coupled-cluster theory (CC) is a highly accurate and versatile method for simulating complex interactions within quantum systems. The extension of CC theory to model mixed electron-photon processes with quantum electrodynamics (QED) has improved our capability to predict cavity-modified chemistry, a field where photons are used as cost-effective and eco-friendly alternatives to catalyze/inhibit chemical reactions. However, calculations with CC methods, even without incorporating QED effects, are often prohibitively expensive. Simulations of larger systems require scalable infrastructures that exist for traditional CC methods but not for QED-CC methods. As such, we present a GPU-enabled, high-performance, open-source implementation of the quantum electrodynamics coupled-cluster method with single and double excitations (QED-CCSD) within the ExaChem quantum chemistry software package. ExaChem relies on the Tensor Algebra for Many-body Methods (TAMM) infrastructure: a parallel heterogeneous tensor library designed to achieve scalable performance on modern heterogeneous supercomputing platforms. Furthermore, we discuss theoretical foundations, algorithmic details, and numerical benchmarks to showcase the larger systems that ExaChem can simulate and how the integration of photonic degrees-of-freedom alters their ground-state properties.

Basis sets↗

High-Quality Factor Microwave Resonators using Rhenium

Coplanar waveguide resonators are a perfect tool to evaluate the losses induced by defects and interfaces in superconducting devices. Even if niobium is the most used superconductor for resonators and qubits, its native oxide at the metal-air (MA) interface limits the device results. Tantalum has recently significantly improved qubit performances due to a thinner and less disordered oxide layer compared to Nb. To further improve the MA interface, we used rhenium, a superconducting material with 1.7 K critical temperature resistant to oxidation: it forms an oxide layer thinner than 1 nm. In this study, we will present a thorough investigation of rhenium CPW resonator measurements with internal quality factors at the single photon level exceeding 2 million. The devices have been fabricated on a sapphire substrate while the processing parameters have been varying and optimized. The measurements have been performed as a function of power and temperature to disentangle different sources of losses, such as two-level systems (TLS) and quasi-particles. A peculiar TLS temperature dependence has been measured and analyzed. In this work, we also vary the participation ratio of the devices to extract the losses introduced by the involved interfaces with higher fidelity and precision. We carried on a deep material characterization effort to link the results to the differences in the fabrication steps, and we will present material characterization measurements performed via AFM, ToF-SIMS, XPS, and TEM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cooled avalanche photodiode used for photon detection

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5 to 3 times more sensitive than presently-available photomultiplier tubes (PPMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than 25 percent were obtained with detector noise levels comparable to the noise of a PMT; higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, Deborah L.↗

A Multi-Spacecraft View of Solar-Energetic-Particle Onsets in the 1977 November 22 Event

We examine the onset timing of solar energetic particles (SEPs) in the large ground-level event (GLE) of 1977 November 22 as observed from six spacecraft at four distinct solar longitudes. In most cases, it was possible to use velocity dispersion of the energetic protons to fix the solar particle release (SPR) time and the path-length traveled by the initial particle burst from each solar longitude. We find that the SPR times do depend upon solar longitude, being earliest for spacecraft that are magnetically well-connected to the source region, and later for longitudes on the flanks of the outward driven shock wave. The earliest SPR time occurs well after peak photon emission from the associated Ha flare. These observations are consistent with conclusions derived from single-longitude observations of different GLE events.

Reames, Donald V.↗

Theory of x-ray photon correlation spectroscopy for multiscale flows

Complex multiscale flows associated with instabilities and turbulence are commonly induced under high-energy density (HED) conditions, but accurate measurement of their transport properties has been challenging. X-ray photon correlation spectroscopy (XPCS) with coherent x-ray sources can, in principle, probe material dynamics to infer transport properties using time autocorrelation of density fluctuations. Here we develop a theoretical framework for utilizing XPCS to study material diffusivity in multiscale flows. We extend single-scale shear flow theories to broadband flows using a multiscale analysis that captures shear and diffusion dynamics. Our theory is validated with simulated XPCS for Brownian particles advected in multiscale flows. We demonstrate the versatility of the method over several orders of magnitude in timescale using sequential-pulse XPCS, single-pulse x-ray speckle visibility spectroscopy (XSVS), and double-pulse XSVS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extreme Blazars Studied with Fermi-Lat and Suzaku: 1ES 0347-121 and Blazar Candidate HESS J1943+213

We report on our study of high-energy properties of two peculiar TeV emitters: the "extreme blazar" 1ES 0347-121 and the "extreme blazar candidate" HESS J1943+213 located near the Galactic plane. Both objects are characterized by quiescent synchrotron emission with flat spectra extending up to the hard X-ray range, and both were reported to be missing GeV (gigaelectronvolt) counterparts in the Fermi Large Area Telescope (LAT) two-year Source Catalog. We analyze a 4.5 year accumulation of the Fermi-LAT data, resulting in the detection of 1ES 0347-121 in the GeV band, as well as in improved upper limits for HESS J1943+213. We also present the analysis results of newly acquired Suzaku data for HESS J1943+213. The X-ray spectrum is well represented by a single power law extending up to 25 keV (kiloelectronvolts) with photon index 2.00 plus or minus 0.02 and a moderate absorption in excess of the Galactic value, which is in agreement with previous X-ray observations. No short-term X-ray variability was found over the 80 kilosecond duration of the Suzaku exposure. Under the blazar hypothesis, we modeled the spectral energy distributions of 1ES 0347-121 and HESS J1943+213, and we derived constraints on the intergalactic magnetic field strength and source energetics. We conclude that although the classification of HESS J1943+213 has not yet been determined, the blazar hypothesis remains the most plausible option since, in particular, the broadband spectra of the two analyzed sources along with the source model parameters closely resemble each other, and the newly available Wide-field Infrared Survey Explorer (WISE) and UKIRT (United Kingdom Infrared Telescope) Infrared Deep Sky Survey data for HESS J1943+213 are consistent with the presence of an elliptical host at the distance of approximately 600 Mpc (megaparsecs).

blazar↗

Photon detection with cooled avalanche photodiodes

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5-3 times more sensitive than presently available photomultiplier tubes (PMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than twice that of a PMT were obtained with detector noise levels below 100 counts per second. Higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, D. L.↗

Radiation damage in scientific charge-coupled devices

Radiation damage is reported on CCDs (charge-coupled devices) that have been primarily exposed to 1.25-MeV gamma rays (Co-60 source). Two important classes of radiation damage are discussed, namely, bulk and ionization effects. Bulk damage or displacement damage is a process in which silicon atoms are displaced from their normal lattice positions by high-energy photons or particles. Single atomic displacements or cluster defect damage is produced, depending on the energy and type of radiation experienced by the detector. Bulk damage creates trapping sites within the CCD's signal channel which in turn degrades charge-transfer efficiency.

Janesick, James↗

A Second Look at 12 Candidate Dual AGNs Using BAYMAX

We present an analysis of 12 optically selected dual active galactic nucleus (AGN) candidates at z < 0.34. Each candidate was originally identified via double-peaked [O III] λ5007 emission lines and received follow-up Chandra and Hubble Space Telescope (HST) observations. Because the X-ray data are low-count (<100 counts) with small separations (<1''), a robust analysis is necessary for classifying each source. Pairing long-slit [O III] observations with existing Chandra observations, we re-analyze the X-ray observations with Bayesian AnalYsis of AGNs in X-rays to determine whether the X-ray emission from each system is more likely a single or dual point source. We find that 4 of the 12 sources are likely dual X-ray point-source systems. We examine each point source's spectra via a Monte Carlo method that probabilistically identifies the likely origin of each photon. When doing so, we find that (i) the secondary X-ray point sources in two of the systems have L(X)< 10(exp 40) erg/s, such that we cannot rule out a non-AGN origin, (ii) one source has a secondary with L(X)> 10(exp 40) erg/s but a spectrum that is too soft to definitively preclude being X-ray emitting diffuse gas that was photoionized by the primary AGN, and (iii) one system (SDSS J1126+2944) is a dual AGN. Additionally, using complementary HST observations, we analyze a subsample of systems that are visually identified as merging. Our results suggest that dual AGNs may preferentially reside in mergers with small separations, consistent with both simulations and observations.

Adi Foord↗

Attosecond delays in X-ray molecular ionization

The photoelectric effect is not truly instantaneous, but exhibits attosecond delays that can reveal complex molecular dynamics. Sub-femtosecond duration light pulses provide the requisite tools to resolve the dynamics of photoionization. Accordingly, the past decade has produced a large volume of work on photoionization delays following single photon absorption of an extreme ultraviolet (XUV) photon. However, the measurement of time-resolved core-level photoionization remained out of reach. The required x-ray photon energies needed for core-level photoionization were not available with attosecond tabletop sources. We have now measured the x-ray photoemission delay of core-level electrons, and here report unexpectedly large delays, ranging up to 700 attoseconds in NO near the oxygen K-shell threshold. These measurements exploit attosecond soft x-ray pulses from a free-electron laser (XFEL) to scan across the entire region near the K-shell threshold. Furthermore, we find the delay spectrum is richly modulated, suggesting several contributions including transient trapping of the photoelectron due to shape resonances, collisions with the Auger-Meitner electron that is emitted in the rapid non-radiative relaxation of the molecule, and multi-electron scattering effects. Finally, the results demonstrate how x-ray attosecond experiments, supported by comprehensive theoretical modelling, can unravel the complex correlated dynamics of core-level photoionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Selected advances in small-angle scattering and applications they serve in manufacturing, energy and climate change

Innovations in small-angle X-ray and neutron scattering (SAXS and SANS) at major X-ray and neutron facilities offer new characterization tools for researching materials phenomena relevant to advanced applications. For SAXS, the new generation of diffraction-limited storage rings, incorporating multi-bend achromat concepts, dramatically decrease electron beam emittance and significantly increase X-ray brilliance over previous third-generation sources. This results in intense X-ray incident beams that are more compact in the horizontal plane, allowing significantly improved spatial resolution, better time resolution, and a new era for coherent-beam SAXS methods such as X-ray photon correlation spectroscopy. Elsewhere, X-ray free-electron laser sources provide extremely bright, fully coherent, X-ray pulses of <100 fs and can support SAXS studies of material processes where entire SAXS data sets are collected in a single pulse train. Meanwhile, SANS at both steady-state reactor and pulsed spallation neutron sources has significantly evolved. Developments in neutron optics and multiple detector carriages now enable data collection in a few minutes for materials characterization over nanometre-to-micrometre scale ranges, opening up real-time studies of multi-scale materials phenomena. SANS at pulsed neutron sources is becoming more integrated with neutron diffraction methods for simultaneous structure characterization of complex materials. In this paper, selected developments are highlighted and some recent state-of-the-art studies discussed, relevant to hard matter applications in advanced manufacturing, energy and climate change.

36 MATERIALS SCIENCE↗

Mid-infrared spectroscopy with a broadly tunable thin-film lithium niobate optical parametric oscillator

Mid-infrared spectroscopy, an important technique for sensing molecules, has encountered barriers from sources either limited in tuning range or excessively bulky for widespread use. We present a compact, efficient, and broadly tunable optical parametric oscillator surmounting these challenges. Leveraging dispersion-engineered thin-film lithium niobate-on-sapphire photonics and a singly resonant cavity allows broad, controlled tuning over an octave from 1.5–3.3 µm. The device generates >25mW of mid-infrared light at 3.2 µm with 15% conversion efficiency. The ability to precisely control the device’s mid-infrared emission enables spectroscopy of methane and ammonia, demonstrating our approach’s relevance for sensing. Our work signifies an important advance in nonlinear photonics miniaturization, bringing practical field applications of high-speed, broadband mid-infrared spectroscopy closer to reality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Raman scattering measurements in flames using a tunable KrF excimer laser

A narrow-band tunable KrF excimer laser is used as a spontaneous vibrational Raman scattering source to demonstrate that single-pulse concentration and temperature measurements, with only minimal fluorescence interference, are possible for all major species (O2, N2, H2O, and H2) at all stoichiometries (fuel-lean to fuel rich) of H2-air flames. Photon-statistics-limited precisions in these instantaneous and spatially resolved single-pulse measurements are typically 5 percent, which are based on the relative standard deviations of single-pulse probability distributions. In addition to the single-pulse N2 Stokes/anti-Stokes ratio temperature measurement technique, a time-averaged temperature measurement technique is presented that matches the N2 Stokes Raman spectrum to theoretical spectra by using a single intermediate state frequency to account for near-resonance enhancement. Raman flame spectra in CH4-air flames are presented that have good signal-to-noise characteristics and show promise for single-pulse UV Raman measurements in hydrocarbon flames.

Wehrmeyer, Joseph A.↗

Flat-spectrum radio sources - Cosmic conspiracy or relativistic neutrons?

The intensity spectrum of the core of radio-loud AGN varies smoothly from 10 exp 8.5 to 10 to the 16th Hz, and is flat between 10 to the 9th and 10 to the 10th Hz, implying that a single emission mechanism is responsible. It is proposed here that energy is transported from the central source by relativistic neutrons which travel freely over a large volume and decay into relativistic protons. The protons produce secondary electrons which generate the observed radiation. The photon spectra thus produced are largely model-independent and flat.

Giovanoni, Peter M.↗