Concentrating Solar Power
This fact sheet contains technology basics, market outlook and other pertinent information to assist the Bureau of Land Management in assessing concentrating solar power projects on BLM-managed land.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This fact sheet contains technology basics, market outlook and other pertinent information to assist the Bureau of Land Management in assessing concentrating solar power projects on BLM-managed land.
Four different spacecraft configurations were developed for geostationary service as a high power communications satellite. The first configuration is a Thor-Delta launch into a low orbit with a spiral ascent to synchronous altitude by ion engine propulsion. The spacecraft is earth oriented with rotating solar arrays. Configuration 2 is a direct injection Atlas/Centaur/Burner II vehicle which when in orbit is sun-oriented with a rotating transponder tower. Configurations 3 and 4 are Titan IIIC launches, and are therefore larger and heavier than Configuration 2. They are both sun-oriented, with rotating transponder towers and are directly injected into orbit. Technology discussed includes high power (up to 2 kW) transmitters with collectors radiating heat directly into space, and contoured antenna patterns designed to illuminate particular earth regions. There is also a review of potential users of the services which can be performed by this type satellite in such areas as information networking, public broadcasting and educational television.
The project overview of this presentation is: (1) description--(a) laboratory R and D in advanced heat transfer fluids (HTF) and thermal storage systems; (b) FOA activities in solar collector and component development for use of molten salt as a heat transfer and storage fluid; (c) applications for all activities include line focus and point focus solar concentrating technologies; (2) Major FY08 Activities--(a) advanced HTF development with novel molten salt compositions with low freezing temperatures, nanofluids molecular modeling and experimental studies, and use with molten salt HTF in solar collector field; (b) thermal storage systems--cost analysis and updates for 2-tank and thermocline storage and model development and analysis to support near-term trought deployment; (c) thermal storage components--facility upgrade to support molten salt component testing for freeze-thaw receiver testing, long-shafted molten salt pump for parabolic trough and power tower thermal storage systems; (d) CSP FOA support--testing and evaluation support for molten salt component and field testing work, advanced fluids and storage solicitation preparation, and proposal evaluation for new advanced HTF and thermal storage FOA.
Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.
Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.
Offshore rectennas are feasible and cost competitive with land rectennas but the type of rectenna suitable for offshore use is quite different from that specified in the present reference system. A nonground plane design minimizes the weight and greatly reduces the number of costly support towers. This perferred design is an antenna array consisting of individually encapsulated dipoles with reflectors or tagis supported on feed wires. Such a 5 GW rectenna could be built at a 50 m water depth site to withstand hurricane, winter storm, and icing conditions for a one time cost of $5.7 billion. Subsequent units would be about 1.3 less expensive. More benign and more shallow water sites would result in substantially lower costs. The major advantage of an offshore rectenna is the removal of microwave radiation from populated areas.
Accurate, high-resolution meteorological measurements of wind flow in the planetary boundary layer (PBL) and surface-atmosphere energy exchange are required for understanding the properties and quality of available wind power at Site 300. Wind speeds at heights found in a typical wind turbine rotor disk (~ 40- 120 m) are driven by the synergistic impacts of atmospheric stability, orography, and land-surface characteristics on the mean wind flow and related turbulence structures in the PBL. In FY11, two Laser and Detection Ranging (LIDAR) units, a 3 m tall flux tower, and a 3 m tall meteorological tower were installed in the northern section of Site 300 as a first step in development of a renewable energy testbed facility. The LIDAR units were programmed to measure wind speed and direction up to 200 m. The flux tower measured land surface-atmospheric energy exchanges and provided information on the mechanisms for turbulence production in the atmosphere and atmospheric stability. Atmospheric stability largely determines wind speed and turbulence profiles in the lower part of the boundary layer where wind turbines reside. In FY12 the SMS project was further expanded by the earlier addition of solar power to the LIDAR units. This enabled the units to be moved to different areas within Site 300 in order to gather a larger spatial range of measurements. Additional LIDAR locations were chosen based on (1) feasibility and logistics (e.g., away from the blast zone and special habitat zones) and (2) areas forecasted to have high wind speeds and/or high turbulence from the Weather Research and Forecasting (WRF) model simulations. High turbulence is of interest because very high amounts of turbulent energy can be damaging to turbine components. Between December 2011-April 2012, the two LIDAR units were rotated amongst three locations: the tall (52 m) meteorological tower, the radio tower, and the Matthew area (named after Matthew Simpson) (Figure 1). The radio tower location was in the center of Site 300 and represented the site with highest elevation and potentially highest wind speeds as forecasted by WRF. The Matthew area in the southeast represented a site with high wind speeds and potentially high levels of turbulence. In FY11 we presented a quality control report which illustrated the accuracy of the LIDAR wind speed and direction measurements as compared to the 52 m tall meteorological tower and provided annual statistics for wind speed and direction up to 200 m for the meteorological tower location in the northern section of Site 300. In the FY12 report we present: 1. a second year of LIDAR and flux tower statistics for 2012, 2. an enhanced spatial dataset of LIDAR observations with the addition of two new sites, and 3. a look at off-site LIDAR field campaigns.
Sodium as a heat transfer fluid (HTF) can achieve temperatures above 700°C to improve power cycle performance for reducing large infrastructure costs of high-temperature systems. Current concentrating solar power (CSP) sensible HTF’s (e.g. air, salts) have poor thermal conductivity, and thus low heat transfer capabilities, requiring a large receiver. The high thermal conductivity of sodium has demonstrated high heat transfer rates on dish and towers systems, which allow a reduction in receiver area by a factor of two to four, reducing re-radiation and convection losses and cost by a similar factor. Sodium produces saturated vapor at pressures suitable for transport starting at 600°C and reaches one atmosphere at 870°C, providing a wide range of suitable latent operating conditions that match proposed high temperature, isothermal input power cycles. This advantage could increase the receiver and system efficiency while lowering the cost of CSP tower systems. Although there are a number of desirable thermal performance advantages associated with sodium, its propensity to rapidly oxidize presents safety challenges. This investigation presents a literature review that captures historical operations/handling lessons for advanced sodium systems, and the current state-of-knowledge related to sodium combustion behavior. Technical and operational solutions addressing sodium safety and applications in CSP will be discussed, including unique safety hazards and advantages using latent sodium. Operation and maintenance experience from the nuclear industry with sensible and latent systems will also be discussed in the context of safety challenges and risk mitigation solutions.
Other than the nine Solar Energy Generation Systems (“SEGS”) parabolic trough projects built in the 1980s, virtually no large-scale or “utility-scale” solar projects – defined here to include any groundmounted photovoltaic (“PV”), concentrating photovoltaic (“CPV”), or concentrating solar thermal power (“CSP”) project larger than 5 MW AC – existed in the United States prior to 2007. By 2012 – just five years later – utility-scale had become the largest sector of the overall PV market in the United States, a distinction that was repeated in both 2013 and 2014 and that is expected to continue for at least the next few years. Over this same short period, CSP also experienced a bit of a renaissance in the United States, with a number of large new parabolic trough and power tower systems – some including thermal storage – achieving commercial operation. With this critical mass of new utility-scale projects now online and in some cases having operated for a number of years (generating not only electricity, but also empirical data that can be mined), the rapidly growing utility-scale sector is ripe for analysis. This report, the third edition in an ongoing annual series, meets this need through in-depth, annually updated, data-driven analysis of not just installed project costs or prices – i.e., the traditional realm of solar economics analyses – but also operating costs, capacity factors, and power purchase agreement (“PPA”) prices from a large sample of utility-scale solar projects in the United States. Given its current dominance in the market, utility-scale PV also dominates much of this report, though data from CPV and CSP projects are presented where appropriate.
This paper presents the development of instrumentation for the measurement of high-temperature thermal conductivity of bulk and coatings using a modulated photothermal radiometry (MPR) method, where a sample is heated by an intensity-modulated laser to probe into different layers of the sample. While MPR has been previously established, most of the previous studies only focus on the measurement at room temperature. The MPR has not been well studied for measurements of bulk and coating materials at high temperatures, which are increasingly important for a multitude of applications, such as materials used in the concentrating solar power (CSP) plants and the nuclear reactors. MPR is a non-contact technique that utilizes the intrinsic thermal emission from the specimens for thermometry, which is favorable for measurements at high temperatures in harsh environment. The authors designed and utilized a sample holder suitable for high temperature measurement up to 973 K with good temperature uniformity within the sample. The high-temperature MPR setup was validated by measuring bulk materials with known thermal conductivity. The setup and technique were then extended to the measurement of black solar-absorbing coatings of 10 to 50 μm thick on various substrates by modulating the frequency of the laser heating beam and the thermal penetration depth. Here, the studies showed that thermal conductivities of typical solar-absorbing coatings are 0.4 ~ 0.8 W m -1 K -1 , indicating a possibly large temperature drop within the coating under high solar irradiation flux, such as over 1000-sun for central solar towers in CSP plants.
The goal of this project was to assess the cost and performance benefits of a sharednode wireless system for heliostat power and control. Through analysis and model development, this project quantified and compared the cost of the shared-node wireless system to the cost of a fully wired system that is representative of the state-of-the-art technology for commercial power tower plants. A second objective was to identify and assess energy storage options to support localized power generation in the heliostat field.
Thermal collector could be used ultimately to power steamplant to produce electricity. Collector would consist of two major subsystems: (1) series of segmented tracking mirrors with two axes of rotation and (2) absorber mounted on centrally located tower.
The U.S. Department of Energy has identified a third generation of concentrated solar power (Gen3 CSP) technologies to minimize cost of CSP produced electricity. By developing these technologies further, it is forecasted that Gen3 CSP will meet the levelized cost of electricity (LCOE) SunShot target of 6 cents/kWh to compete with dominant, conventional nonrenewable energy sources (1). The focus for advancing CSP systems for Gen3 is to increase overall system efficiency. Thus, reevaluating second-generation systems, superheated steam-turbine power cycles, and implementing more advanced power cycles is essential. Specifically, it has been identified that a supercritical carbon dioxide (sCO 2 ) Brayton cycle can increase the net thermal-to-electric efficiency to over 50% for CSP power tower configurations (2). Compared to conventional superheated steam Rankine cycle systems, more extreme operating conditions are required and pose critical barriers to overcome in the field of materials and manufacturing for Gen3 CSP.
The cost of solar collectors constitutes almost one third of the total cost of a CSP plant. One of the ongoing challenges in the design of these collectors is wind loading on mirrors, support structures, and drives. A particular challenge is dynamic wind loading, caused by the turbulent wind flow. To date, the design of solar collector structures has relied on wind tunnel experiments and numerical simulations that do not entirely capture the dynamic effects observed at scale. The CSP industry has shown increased interest in validating the idealized assumptions with measurements obtained in operational settings to improve wind load assumptions and increase reliability and cost-efficiency of the collector design. Further, performance models need realistic assumptions about wind loading and its impact on optical performance. In a parabolic trough field campaign, NREL successfully collected a wealth of long-term, high-resolution wind and loads data [2], that are publicly available and that can be used for the above-mentioned purposes. Heliostats are impacted differently by wind than parabolic troughs, due to their different shape, size, and field layout. To study the impact of wind and turbulence on heliostats, we initiated another field campaign in an operational power- tower plant, Crescent Dunes, in Nevada, USA. In this work, we present an overview of the measurements, first results, and potential implications of wind driven loads on Heliostats.
At the lunar south pole, solar arrays elevated by truss towers are exposed to near continuous sunlight since the sun remains near the horizon. Recent studies suggest that tower heights on the order of 50 m are needed to meet the power requirements to support a sustained lunar presence. While eventually towers may be constructed using materials sourced in-situ, initially structural elements will likely be brought from the Earth, deployed, and assembled. Thermoplastic composites offer the benefit of high specific stiffness and strength properties along with welding for assembly joints, and therefore represent a promising material system for this application. The focus of this paper is on the structural sizing of such towers. A set of expressions based on beam theory are presented for preliminary sizing of the truss tower structure for strength and buckling. The loading condition that drives sizing is base excitation resulting from moonquakes. A point design, developed through finite element analysis, verifies the analytical sizing routine and shows the importance of joints. The results show a viable point design and highlight the factors most significant in the structural sizing.
At the lunar south pole, solar arrays elevated by truss towers are exposed to near continuous sunlight since the sun remains near the horizon. Recent studies suggest that tower heights on the order of 50 m are needed to meet the power requirements to support a sustained lunar presence. While eventually towers may be constructed using materials sourced in-situ, initially structural elements will likely be brought from the Earth, deployed, and assembled. Thermoplastic composites offer the benefit of high specific stiffness and strength properties along with welding for assembly joints, and therefore represent a promising material system for this application. The focus of this paper is on the structural sizing of such towers. A set of expressions based on beam theory are presented for preliminary sizing of the truss tower structure for strength and buckling. The loading condition that drives sizing is base excitation resulting from moonquakes. A point design, developed through finite element analysis, verifies the analytical sizing routine and shows the importance of joints. The results show a viable point design and highlight the factors most significant in the structural sizing.
At the lunar south pole, solar arrays elevated by truss towers are exposed to near continuous sunlight since the sun remains near the horizon. Recent studies suggest that tower heights on the order of 50 m are needed to meet the power requirements to support a sustained lunar presence. While eventually towers may be constructed using materials sourced in-situ, initially structural elements will likely be brought from the Earth, deployed, and assembled. Thermoplastic composites offer the benefit of high specific stiffness and strength properties along with welding for assembly joints, and therefore represent a promising material system for this application. The focus of this paper is on the structural sizing of such towers. A set of expressions based on beam theory are presented for preliminary sizing of the truss tower structure for strength and buckling. The loading condition that drives sizing is base excitation resulting from moonquakes. A point design, developed through finite element analysis, verifies the analytical sizing routine and shows the importance of joints. The results show a viable point design and highlight the factors most significant in the structural sizing.
In connection with the Bureau of Land Management’s (BLM’s) Solar Programmatic Environmental Impact Statement (Solar PEIS), Argonne National Laboratory (Argonne) has conducted an extended visual impact analysis for selected key observation points (KOPs) within three National Park Service (NPS) units located within the 25-mi (40-km) viewshed of four solar energy zones (SEZs) identified in the Solar PEIS. The analysis includes only those NPS units that the Solar PEIS identified as potentially subject to moderate or strong visual contrasts associated with solar development within the SEZs. The NPS units included in the analysis are Death Valley and Joshua Tree National Parks and El Camino Real De Tierra Adentro National Historic Trail. The analysis showed that certain KOPs in each of these NPS units could potentially be subject to major visual contrast and impacts from solar development within the SEZs, but many of the KOPs would likely be subject to moderate, minor, or negligible contrasts and impacts, generally because they were relatively distant from the relevant SEZ, had views of the SEZ partially blocked by intervening terrain, and/or had very low vertical angles of view toward the SEZ. For all three NPS units, power tower facilities were found to be major contributors to potential visual contrasts, primarily because of the long-distance visibility of intensely bright reflection of light from the receivers on the central towers, but also because of the height and strong vertical line of the tower structures and the potential for night-sky impacts from FAA-mandated hazard navigation lighting.