Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar diffuser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Earth Observing-1 Advanced Land Imager Flight Performance Assessment: Absolute Radiometry and Stability During the First Year

The absolute radiometry of the Advanced Land Imager during the first year on orbit (November 21,2000 - November 21, 2001) is presented. Results derived from solar, lunar, ground truth, and internal reference lamp measurements are presented. An 18% drop in the radiometric response of the Band 1p data since preflight calibration at Lincoln Laboratory is observed using all techniques. This decrease cannot be accounted for by preflight calibration errors, stray light, or contamination of the focal plane. A slight drooping of the VNIR response toward the blue and a 5-12% increase in the Band 5 response is also apparent in all the data. Radiometric response correction factors have been calculated and preflight calibration coefficients have been updated in order to provide +/- 5% agreement between the measured solar, lunar, and ground truth data and the expected values. The radiometric stability of the ALI during the first year of operation is also presented for each spectral band. Internal reference lamp data indicate the focal plane has been stable to within 1% for bands 1p, 1, 2, 5p, 5, 7, pan and 3% for Bands 3,4, 4p since launch. Solar, lunar, and ground truth measurements indicate the optical train and solar diffuser of the instrument has been stable to within 1% since initial measurements on orbit in late December 2000.

Mendenhall, J. A.↗

Validation of the CERES Shortwave Measurements over Desert and Cloud Scenes

The Clouds and the Earth's Radiant Energy System (CERES) broadband shortwave channel, 0.3 - 5 micron, measures atmosphere and surface reflected solar radiation. CERES provides an in-flight tungsten lamp to monitor the shortwave radiometric stability over the lifetime of the instrument. Initial Tropical Rainfall Measurement Mission (TRMM) tungsten calibration results indicate a 0.6% change over the first six months of mission life. The three channel intercomparison technique and the solar diffuser calibration results show shortwave stabilities of 0.2% and 0.3% for the same time period. Current belief is that the tungsten lamp, not the radiometer, has drifted. Radiometers, optics, and onboard calibrators exposed to the harsh space environment often degrade. Independent validation studies based on bright Earth viewing measurements are necessary to support the in-flight filtered calibration results. Instrument measurements of filtered radiances are

Currey, Chris↗

MODIS Solar Calibration Simulation Assisted Refinement

A detailed optical radiometric model has been created of the MODIS instruments solar calibration process. This model takes into account the orientation and distance of the spacecraft with respect to the sun, the correlated motions of the scan mirror and the sun, all of the optical elements, the detector locations on the visible and near IR focal planes, the solar diffuser and the attenuation screen with all of its hundreds of pinholes. An efficient computational scheme, takes into account all of these factors and has produced results which reproduce the observed time dependent intensity variations on the two focal planes with considerable fidelity. This agreement between predictions and observations, has given insight to the causes of some small time dependent variations and how to incorporate them into the overall calibration scheme. The radiometric model is described and modeled and actual measurements are presented and compared.

Waluschka, Eugene↗

The Calibration of AVHRR Visible Dual Gain using Meteosat-8 for NOAA-16 to 18

The NOAA AVHRR program has given the remote sensing community over 25 years of imager radiances to retrieve global cloud, vegetation, and aerosol properties. This dataset can be used for long-term climate research, if the AVHRR instrument is well calibrated. Unfortunately, the AVHRR instrument does not have onboard visible calibration and does degrade over time. Vicarious post-launch calibration is necessary to obtain cloud properties that are not biased over time. The recent AVHRR-3 instrument has a dual gain in the visible channels in order to achieve greater radiance resolution in the clear-sky. This has made vicarious calibration of the AVHRR-3 more difficult to unravel. Reference satellite radiances from well-calibrated instruments, usually equipped with solar diffusers, such as MODIS, have been used to successfully vicariously calibrate other visible instruments. Transfer of calibration from one satellite to another using co-angled, collocated, coincident radiances has been well validated. Terra or Aqua MODIS and AVHRR comparisons can only be performed over the poles during summer. However, geostationary satellites offer a transfer medium that captures both parts of the dual gain. This AVHRR-3 calibration strategy uses, calibrated with MODIS, Meteosat-8 radiances simultaneously to determine the dual gains using 50km regions. The dual gain coefficients will be compared with the nominal coefficients. Results will be shown for all visible channels for NOAA-17.

Doelling, David R.↗

Summary of Terra and Aqua MODIS On-orbit Calibration and Characterization Results

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard NASA's EOS Terra spacecraft has been in operation for more than seven years since its launch in December 1999 and the MODIS onboard Aqua spacecraft has been in operation for more than 4.5 years since its launch in May 2002. Compared to its heritage sensors, such as AVHRR, CZCS, SeaWiFS, HIRS, and Landsat TM, the MODIS instrument was developed with improved spectral and spatial resolutions, and temporal scale or global coverage frequency. The two MODIS instruments are nearly identical with each collecting data in 36 spectral bands: 20 reflective solar bands (RSB) with center wavelengths from 0.41 to 2.2jm and 16 thermal emissive bands (TEB) from 3.7 to 4.4 microns. MODIS makes the Earth view observations with a scan angle range of +/-55 degree relative to instrument nadir and at three nadir spatial resolutions: 0.25km for bands 1-2.05km for bands 3-7, and 1km for bands 8-36, thus enabling complete global coverage of the Earth in less than 2 days. Both Terra and Aqua MODIS observations have been routinely used to generate a broad range of science data products that are widely distributed and extensively applied for the studies of the Earth's land, oceans, and atmosphere and for the monitoring of climate and environmental changes. It is obvious that the MODIS science data product quality strongly relies on sensor on-orbit performance and its capability of continuously tracking sensor response changes over time. Because of this, each MODIS was built with a comprehensive set of on-board calibrators (OBC) that include a solar diffuser (SD) for the RSB calibration, a blackbody (BB) for the TEB calibration, and a spectro-radiometric calibration assembly (SRCA) for the spatial (RSB and TEB) and spectral (RSB only) characterization. Most importantly, extensive and dedicated sensor calibration and characterization efforts have been constantly made by the MODIS Characterization Support Team (MCST) at NASA/GSFC. In this presentation, we will provide an overview of MODIS sensor operations since 1aunh and the onorbit calibration and characterization methodologies with emphasis on the differences between Terra and Aqua MODIS characteristics. We will summarize both Terra and Aqua MODIS onorbit calibration and characterization results, including their RSB and TEB detector noise characterization, the sensor response changes, and the corrections to the optics degradation. In addition to radiometric calibration performance, we will illustrate both sensors' spectral and spatial characterization results in terms of their band-to-band registrations and spectral band center wavelength shifts.

Xiong, X.↗

Sensor On-orbit Calibration and Characterization Using Spacecraft Maneuvers

Spacecraft flight operations often require activities that involve different kinds of maneuvers for orbital adjustments (pitch, yaw, and roll). Different maneuvers, when properly planned and scheduled, can also be applied to support and/or to perform on-board sensor calibration and characterization. This paper uses MODIS (Moderate Resolution Imaging Spectroradiometer) as an example to illustrate applications of spacecraft maneuvers for Earth-observing sensors on-orbit calibration and characterization. MODIS is one of the key instruments for NASA's Earth Observing System (EOS) currently operated on-board the EOS Terra and Aqua spacecraft launched in December 1999 and May 2002, respectively. Since their launch, both Terra and Aqua spacecraft have made a number of maneuvers, specially the yaw and roll maneuvers, to support the MODIS on-orbit calibration and characterization. For both Terra and Aqua MODIS, near-monthly spacecraft roll maneuvers are executed for lunar observations. These maneuvers are carefully scheduled so that the lunar phase angles are nearly identical for each sensor's lunar observations. The lunar observations are used to track MODIS reflective solar bands (RSB) calibration stability and to inter-compare Terra and Aqua MODIS RSB calibration consistency. To date, two sets of yaw maneuvers (each consists of two series of 8 consecutive yaws) by the Terra spacecraft and one set by the Aqua spacecraft have been performed to validate MODIS solar diffuser (SD) bi-directional reflectance factor (BRF) and to derive SD screen transmission. Terra spacecraft pitch maneuvers, first made on March 26, 2003 and the second on April 14, 2003 (with the Moon in the spacecraft nadir view), have been applied to characterize MODIS thermal emissive bands (TEB) response versus scan angle (RVS). This is particularly important since the pre-launch TEB RSV measurements made by the sensor vendor were not successful. Terra MODIS TEB RVS obtained from pitch maneuvers have been used in the current LIB calibration algorithm. Lunq observations from pitch maneuvers also provided information to cross-calibrate MODIS with other sensors (MISR and ASTER) on the same platform. We will provide a summary of MODIS maneuver activities and their applications for MODIS calibration and characterization. The results and lessons learned discussed in this paper from MODIS maneuver activities will provide useful insights into future spacecraft and sensor operation.

Xiong, X.↗

Characterization of MODIS VIS/NIR Spectral Band Detector-to-Detector Difference

MODIS has 36 spectral bands with wavelengths in the visible (VIS), near-infrared (NIR), shortwave infrared (SWTR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). It makes observations at three nadir spatial resolutions: 0,25km for bands 1-2 with 40 detectors per band, 0.5km for bands 3-7 with 20 detectors per band, and 1km for bands 8-36 with 10 detectors per band. The VIS, NIR, and S\VIR spectral bands are the reflective solar bands (RSB), which are calibrated on-orbit by a solar diffuser (SD). In addition, MODIS lunar observations are used to track the RSB calibration stability. In this study, we examine detector-to-detector calibration difference for the VIStNIR spectral bands using the SD and lunar observations. The results will be compared with an independent analysis with additional information, such as polarization correction, derived from standard ocean color data products. The current MODIS RSB calibration approach only carries a band-averaged RVS (response versus scan angle) correction. The results from this study suggest that a detector-based RVS correction should be used to improve the L1B data quality, especially for several VIS bands in Terra MODIS due to large changes of the scan mirror's optical properties in recent years.

Xiong, X.↗

Landsat Data Continuity Mission Calibration and Validation

The primary payload for the Landsat Data Continuity Mission (LDCM) is the Operational Land Imager (OLI), being built by Ball Aerospace and Technologies, under contract to NASA. The OLI has spectral bands similar to the Landsat-7 ETM+, minus the thermal band and with two new bands, a 443 nm band and 1375 nm cirrus detection band. On-board calibration systems include two solar diffusers (routine and pristine), a shutter and three sets of internal lamps (routine, backup and pristine). Being a pushbroom opposed to a whiskbroom design of ETM+, the system poses new challenges for characterization and calibration, chief among them being the large focal plane with 75000+ detectors. A comprehensive characterization and calibration plan is in place for the instrument and the data throughout the mission including Ball, NASA and the United States Geological Survey, which will take over operations of LDCM after on-orbit commissioning. Driving radiometric calibration requirements for OLI data include radiance calibration to 5% uncertainty (1 q); reflectance calibration to 3% uncertainty (1 q) and relative (detector-to-detector) calibration to 0.5% (J (r). Driving geometric calibration requirements for OLI include bandto- band registration of 4.5 meters (90% confidence), absolute geodetic accuracy of 65 meters (90% CE) and relative geodetic accuracy of 25 meters (90% CE). Key spectral, spatial and radiometric characterization of the OLI will occur in thermal vacuum at Ball Aerospace. During commissioning the OLI will be characterized and calibrated using celestial (sun, moon, stars) sources and terrestrial sources. The USGS EROS ground processing system will incorporate an image assessment system similar to Landsat-7 for characterization and calibration. This system will have the added benefit that characterization data will be extracted as part of the normal image data processing, so that the characterization data available will be significantly larger than for Landsat-7 ETM+.

Markham, Brian L.↗

The Characterization of Deep Convective Cloud Albedo as a Calibration Target Using MODIS Reflectances

There are over 25 years of historical satellite data available to climate analysis. The historical satellite data needs to be well calibrated, especially in the visible, where there is no onboard calibration on operational satellites. The key to the vicarious calibration of historical satellites relies on invariant targets, such as the moon, Dome C, and deserts. Deep convective clouds (DCC) also show promise of being a stable invariant or predictable target viewable by all satellites, since they behave as solar diffusers. However DCC have not been well characterized for calibration. Ten years of well-calibrated MODIS is now available. DCC can easily be identified using IR thresholds, where the IR calibration can be traced to the onboard black-bodies. The natural variability of DCC albedo will be analyzed geographically and seasonally, especially difference of convection initiated over land or ocean. Functionality between particle size and ozone absorption with DCC albedo will be examined. Although DCC clouds are nearly Lambertion, the angular distribution of reflectances will be sampled and compared with theoretical models. Both Aqua and Terra MODIS DCC angular models will be compared for consistency. Normalizing angular geostationary DCC reflectances, which were calibrated against MODIS, with SCIAMACHY spectral reflectances and comparing them to MODIS DCC reflectances will inspect the usage of DCC albedos as an absolute calibration target.

Doelling, David R.↗

MODIS On-orbit Calibration Uncertainty Assessment

MODIS has 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration uncertainty requirements. As a result, MODIS was designed and built with a set of on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and an in-depth analysis of its on-orbit calibration uncertainties. Also discussed in this paper are uncertainty contributions from individual components and differences due to Terra and Aqua MODIS instrument characteristics and on-orbit performance.

Chiang, Vincent↗

A Maximum Likelihood Approach to Determine Sensor Radiometric Response Coefficients for NPP VIIRS Reflective Solar Bands

Optical sensors aboard Earth orbiting satellites such as the next generation Visible/Infrared Imager/Radiometer Suite (VIIRS) assume that the sensors radiometric response in the Reflective Solar Bands (RSB) is described by a quadratic polynomial, in relating the aperture spectral radiance to the sensor Digital Number (DN) readout. For VIIRS Flight Unit 1, the coefficients are to be determined before launch by an attenuation method, although the linear coefficient will be further determined on-orbit through observing the Solar Diffuser. In determining the quadratic polynomial coefficients by the attenuation method, a Maximum Likelihood approach is applied in carrying out the least-squares procedure. Crucial to the Maximum Likelihood least-squares procedure is the computation of the weight. The weight not only has a contribution from the noise of the sensor s digital count, with an important contribution from digitization error, but also is affected heavily by the mathematical expression used to predict the value of the dependent variable, because both the independent and the dependent variables contain random noise. In addition, model errors have a major impact on the uncertainties of the coefficients. The Maximum Likelihood approach demonstrates the inadequacy of the attenuation method model with a quadratic polynomial for the retrieved spectral radiance. We show that using the inadequate model dramatically increases the uncertainties of the coefficients. We compute the coefficient values and their uncertainties, considering both measurement and model errors.

Lei, Ning↗

MODIS Radiometric Calibration and Uncertainty Assessment

Since launch, Terra and Aqua MODIS have collected more than II and 9 years of datasets for comprehensive studies of the Earth's land, ocean, and atmospheric properties. MODIS observations are made in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration and uncertainty requirements. As a result, MODIS was designed and built with a set of state of the art on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated if necessary. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and discusses details of its on-orbit calibration uncertainties. It assesses uncertainty contributions from individual components and differences between Terra and Aqua MODIS due to their design characteristics and on-orbit periormance. Also discussed in this paper is the use of MODIS LIB uncertainty index CUI) product.

Xiong, Xiaoxiong↗

The Landsat Data Continuity Mission Operational Land Imager: Radiometric Performance

The Operational Land Imager (OLI) is one of two instruments to fly on the Landsat Data Continuity Mission (LDCM), which is scheduled to launch in December 2012 to become the 8th in the series of Landsat satellites. The OLI images in the solar reflective part of the spectrum, with bands similar to bands 1-5, 7 and the panchromatic band on the Landsat-7 ETM+ instrument. In addition, it has a 20 nm bandpass spectral band at 443 nm for coastal and aerosol studies and a 30 nm band at 1375 nm to aid in cirrus cloud detection. Like ETM+, spatial resolution is 30 m in the all but the panchromatic band, which is 15 meters. OLI is a pushbroom radiometer with approximately 6000 detectors per 30 meter band as opposed to the 16 detectors per band on the whiskbroom ETM+. Data are quantized to 12 bits on OLI as opposed to 8 bits on ETM+ to take advantage of the improved signal to noise ratio provided by the pushbroom design. The saturation radiances are higher on OLI than ETM+ to effectively eliminate saturation issues over bright Earth targets. OLI includes dual solar diffusers for on-orbit absolute and relative (detector to detector) radiometric calibration. Additionally, OLI has 3 sets of on-board lamps that illuminate the OLI focal plane through the full optical system, providing additional checks on the OLI's response[l]. OLI has been designed and built by Ball Aerospace & Technology Corp. (BATC) and is currently undergoing testing and calibration in preparation for delivery in Spring 2011. Final pre-launch performance results should be available in time for presentation at the conference. Preliminary results will be presented below. These results are based on the performance of the Engineering Development Unit (EDU) that was radiometrically tested at the integrated instrument level in 2010 and assembly level measurements made on the flight unit. Signal-to-Noise (SNR) performance: One of the advantages of a pushbroom system is the increased dwell time of the detectors allowing for significantly higher SNR than equivalent aperture whiskbroom systems. OLI performance based on the EDU at the "typical" radiance level as specified in the OLI requirements document are about 10 times better than ETM+ performance and 2-3 times better than the requirements for OLI (Table 1).

Markham, Brian↗

An Algorithm for the Retrieval of 30-m Snow-Free Albedo from Landsat Surface Reflectance and MODIS BRDF

We present a new methodology to generate 30-m resolution land surface albedo using Landsat surface reflectance and anisotropy information from concurrent MODIS 500-m observations. Albedo information at fine spatial resolution is particularly useful for quantifying climate impacts associated with land use change and ecosystem disturbance. The derived white-sky and black-sky spectral albedos maybe used to estimate actual spectral albedos by taking into account the proportion of direct and diffuse solar radiation arriving at the ground. A further spectral-to-broadband conversion based on extensive radiative transfer simulations is applied to produce the broadband albedos at visible, near infrared, and shortwave regimes. The accuracy of this approach has been evaluated using 270 Landsat scenes covering six field stations supported by the SURFace RADiation Budget Network (SURFRAD) and Atmospheric Radiation Measurement Southern Great Plains (ARM/SGP) network. Comparison with field measurements shows that Landsat 30-m snow-free shortwave albedos from all seasons generally achieve an absolute accuracy of +/-0.02 - 0.05 for these validation sites during available clear days in 2003-2005,with a root mean square error less than 0.03 and a bias less than 0.02. This level of accuracy has been regarded as sufficient for driving global and regional climate models. The Landsat-based retrievals have also been compared to the operational 16-day MODIS albedo produced every 8-days from MODIS on Terra and Aqua (MCD43A). The Landsat albedo provides more detailed landscape texture, and achieves better agreement (correlation and dynamic range) with in-situ data at the validation stations, particularly when the stations include a heterogeneous mix of surface covers.

Shuai, Yanmin↗

Initial On-Orbit Radiometric Calibration of the Suomi NPP VIIRS Reflective Solar Bands

The on-orbit radiometric response calibration of the VISible/Near InfraRed (VISNIR) and the Short-Wave InfraRed (SWIR) bands of the Visible/Infrared Imager/Radiometer Suite (VIIRS) aboard the Suomi National Polar-orbiting Partnership (NPP) satellite is carried out through a Solar Diffuser (SD). The transmittance of the SD screen and the SD's Bidirectional Reflectance Distribution Function (BRDF) are measured before launch and tabulated, allowing the VIIRS sensor aperture spectral radiance to be accurately determined. The radiometric response of a detector is described by a quadratic polynomial of the detector?s digital number (dn). The coefficients were determined before launch. Once on orbit, the coefficients are assumed to change by a common factor: the F-factor. The radiance scattered from the SD allows the determination of the F-factor. In this Proceeding, we describe the methodology and the associated algorithms in the determination of the F-factors and discuss the results.

Lei, Ning↗

VIIRS On-Orbit Optical Anomaly - Investigation, Analysis, Root Cause Determination and Lessons Learned

A gradual, but persistent, decrease in the optical throughput was detected during the early commissioning phase for the Suomi National Polar-Orbiting Partnership (SNPP) Visible Infrared Imager Radiometer Suite (VIIRS) Near Infrared (NIR) bands. Its initial rate and unknown cause were coincidently coupled with a decrease in sensitivity in the same spectral wavelength of the Solar Diffuser Stability Monitor (SDSM) raising concerns about contamination or the possibility of a system-level satellite problem. An anomaly team was formed to investigate and provide recommendations before commissioning could resume. With few hard facts in hand, there was much speculation about possible causes and consequences of the degradation. Two different causes were determined as will be explained in this paper. This paper will describe the build and test history of VIIRS, why there were no indicators, even with hindsight, of an on-orbit problem, the appearance of the on-orbit anomaly, the initial work attempting to understand and determine the cause, the discovery of the root cause and what Test-As-You-Fly (TAYF) activities, can be done in the future to greatly reduce the likelihood of similar optical anomalies. These TAYF activities are captured in the lessons learned section of this paper.

Iona, Glenn↗

Overview of Aqua MODIS 10-year On-orbit Calibration and Performance

Since launch in May 2002, Aqua MODIS has successfully operated for nearly 10 years, continuously collecting global datasets for scientific studies of key parameters of the earth's land, ocean, and atmospheric properties and their changes over time. The quality of these geophysical parameters relies on the input quality of sensor calibrated radiances. MODIS observations are made in 36 spectral bands with wavelengths ranging from visible (VIS) to longwave infrared (LWIR). Its reflective solar bands (RSB) are calibrated using data collected from its on-board solar diffuser and regularly scheduled lunar views. The thermal emissive bands (TEB) are calibrated using an on-board blackbody (BB). The changes in the sensor's spectral and spatial characteristics are monitored by an on-board spectroradiometric calibration assembly (SRCA). This paper presents an overview of Aqua MODIS 10-year on-orbit operation and calibration activities, from launch to present, and summarizes its on-orbit radiometric, spectral, and spatial calibration and characterization performance. In addition, it will illustrate and discuss on-orbit changes in sensor characteristics and corrections applied to continuously maintain the sensor level 1B (L1B) data quality, as well as lessons learned that could benefit future calibration efforts.

Xiong, X.↗

Time-Dependent Response Versus Scan Angle for MODIS Reflective Solar Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments currently operate onboard the National Aeronautics and Space Administration (NASA's) Terra and Aqua spacecraft, launched on December 18, 1999 and May 4, 2002, respectively. MODIS has 36 spectral bands, among which 20 are reflective solar bands (RSBs) covering a spectral range from 0.412 to 2.13 μm. The RSBs are calibrated on orbit using a solar diffuser (SD) and an SD stability monitor and with additional measurements from lunar observations via a space view (SV) port. Selected pseudo-invariant desert sites are also used to track the RSB on-orbit gain change, particularly for short-wavelength bands. MODIS views the Earth surface, SV, and the onboard calibrators using a two-sided scan mirror. The response versus scan angle (RVS) of the scan mirror was characterized prior to launch, and its changes are tracked using observations made at different angles of incidence from onboard SD, lunar, and Earth view (EV) measurements. These observations show that the optical properties of the scan mirror have experienced large wavelength-dependent degradation in both the visible and near infrared spectral regions. Algorithms have been developed to track the on-orbit RVS change using the calibrators and the selected desert sites. These algorithms have been applied to both Terra and Aqua MODIS Level 1B (L1B) to improve the EV data accuracy since L1B Collection 4, refined in Collection 5, and further improved in the latest Collection 6 (C6). In C6, two approaches have been used to derive the time-dependent RVS for MODIS RSB. The first approach relies on data collected from sensor onboard calibrators and mirror side ratios from EV observations. The second approach uses onboard calibrators and EV response trending from selected desert sites. This approach is mainly used for the bands with much larger changes in their time-dependent RVS, such as the Terra MODIS bands 1-4, 8, and 9 and the Aqua MODIS bands 8- and 9. In this paper, the algorithms of these approaches are described, their performance is demonstrated, and their impact on L1B products is discussed. In general, the shorter wavelength bands have experienced a larger on-orbit RVS change, which, in general, are mirror side and detector dependent. The on-orbit RVS change due to the degradation of band 8 can be as large as 35 percent for Terra MODIS and 20 percent for Aqua MODIS. Vital to maintaining the accuracy of the MODIS L1B products is an accurate characterization of the on-orbit RVS change. The derived time-independent RVS, implemented in C6, makes an important improvement to the quality of the MODIS L1B products.

MODIS↗