Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Numerical analyses of high temperature dense, granular flows coupled to high temperature flow property measurements for solar thermal energy storage

High temperature particle flow properties necessary to predict granular flow behavior for solar thermal energy storage applications were measured and calculated for Carbobead CP 30/60 up to 800 °C. Here, the measured properties included elastic and shear moduli, particle-particle coefficients of static sliding and rolling friction, and particle-particle coefficients of restitution. Poisson’s ratio was calculated with elastic and shear moduli. The flow properties were used as inputs for a numerical model using the discrete element method to examine granular flows along an inclined plane at high temperature. The flow behavior was strongly influenced by the coefficients of static friction, which impacted the particle residence time, shear effects from the side walls, and particle flow mass flux. An 8.7%, 15.6%, and 8.5% increase and 37.9% decrease in steady state mass flow rate was observed for 200 °C, 400 °C, 600 °C, and 800 °C, respectively, when compared to room temperature simulations. A 52%, 59%, and 33% decrease in the time to reach steady state was observed for 200 °C, 400 °C, and 600 °C, respectively, while a 53% increase in time was observed for 800 °C. A significant delay in the flow development at 800 °C was observed due to significantly higher frictional forces.

14 SOLAR ENERGY↗

Experimental characterization of extreme temperature granular flows for solar thermal energy transport and storage

High-temperature, dense granular flows along an inclined plane were considered for solar thermal energy transport and storage with sintered bauxite particles. A series of experiments was performed for particle inlet temperatures of ~ 200, 400, 600, and 800 °C to understand the mechanisms of granular flows at extreme temperatures. Mass flow rates were measured using a load cell and free-surface velocities were measured and computed using particle image velocimetry. Surface temperatures were measured using infrared cameras. A significant decrease in steady-state particle mass flow rate was observed with increasing temperature due to changing flow properties. A decrease in bulk particle free-surface velocities was observed at higher temperatures. Free-surface velocity measurement error between experiments were within 20% of the average. The particle surface temperatures decreased from inlet to outlet with larger gradients at higher temperatures observed due to increasing convection and radiative heat losses. Here, a decrease in temperature was observed along the side walls due to a decrease in particle velocities.

14 SOLAR ENERGY↗

HP-FLEX MPC v0.1.0

HP-FLEX MPC is control software developed by Lawrence Berkeley National Laboratory with support from the California Energy Commission (CEC) through EPIC-19-301. HP-FLEX aims to provide load flexibility for heat pumps (HPs) in response to dynamic grid signals (including Time-of-Use, Dynamic Pricing, and Critical Peak Pricing) while maintaining thermostat temperatures within user-specified bounds. The software includes a system-identification module, which models the dynamics of the building envelope with thermostat data, and a control module based on a model predictive controller (MPC) to make optimal decisions. HP-FLEX receives forecasts of outdoor air temperature, solar irradiation, and internal gain (if available), as well as trajectories of energy price, temperature lower and upper bounds over a prediction horizon. It then optimizes heating and cooling capacities to minimize energy cost and peak power (with a user-defined weight on peak power) over the prediction horizon, while maintaining room air temperature within the temperature constraints, and outputs the optimal thermostat setpoints.

Kim, Donghun↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY↗

Integrated linker-regulation and ring-fusion engineering for efficient additive-free non-fullerene organic solar cells

The rational molecular design and structural modification of quasi-two-dimensional fused perylene diimide (quasi-2D FPDI) acceptors have received growing attention for application in non-fullerene organic solar cells (NF-OSCs). Herein, we designed and synthesized two pairs of FPDI acceptors, one in the form of FPDI–π-bridge–FPDI with the π-bridge being either an axisymmetric thiophene (T) or a centrosymmetric thienothiophene (TT) unit, and the other being the corresponding ring-fusion counterpart. Additionally, four small molecule acceptors, namely T-FPDI, TT-FPDI, FT-FPDI and FTT-FPDI, were paired with a common PTB7-Th polymeric electron donor as active materials for a comparative study of the effects of linkers and ring fusion on their photovoltaic performances. The T-FPDI-based NF-OSC exhibited a decent power conversion efficiency (PCE) of 5.50%, while a higher PCE of 7.17% with a simultaneous enhancement in the open circuit voltage ( V oc ), the short-circuit current density ( J sc ) and the fill factor (FF) was achieved for the TT-FPDI-based solar cells. The solar cells based on the ring-fused FT-FPDI and FTT-FPDI acceptors displayed PCEs of 6.75% and 7.66%, respectively, both higher than those of the corresponding non-fused counterparts. Notably, the trade-off between the J sc and V oc , commonly observed in fullerene OSCs, is alleviated in these systems. It is also worth noting that the NF-OSCs based on these FPDI acceptors do not need any solvent additives. Overall, this successful molecular engineering based on novel quasi-2D FPDI building blocks may inspire the development of emergent electron acceptors for high performance additive-free NF-OSCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the Generation 3 Particle Pilot Plant Falling Particle Receiver

A falling particle receiver (FPR) has been designed to integrate with the G3P3-USA pilot plant currently being constructed at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories. This receiver integrates several innovative design features including a converging tunnel (SNOUT), an optimized cavity geometry, and a multistage “catch-and-release” trough. Details about the integration of these features and the final G3P3-USA FPR design and construction are described. Ray-tracing models of the FPR utilizing the NSTTF heliostat field are developed leveraging previous modeling efforts using SolTrace. Models demonstrate that at least 1.5 MWth of incident radiative energy can be provided to the FPR on a clear day throughout a typical year in Albuquerque, NM. Spillage fluxes around the periphery of the aperture are within acceptable bounds for the majority of the year. Intercept factors are computed for each utilized heliostat at the Vernal equinox to provide guidance to heliostat operators during operation of the system.

Mills, Brantley↗

Case Studies and Parametric Analysis of Heliostat Performance With a Tradeoff-Informed Technoeconomic Analysis Metric

The Heliostat Consortium (HelioCon) was launched in 2021 to advance heliostat technology. Here this work presents a collection of baseline case studies for the technoeconomic analysis (TEA) of candidate heliostat improvements for concentrating solar power (CSP) and concentrated solar thermal (CST) systems that employ central receivers. The case studies we develop include a large-scale CSP plant, a smaller, modular CSP plant, and a small CST plant used for industrial process heat. In this work, we also propose a novel metric for TEA of a plant component technology that recasts relative changes in levelized system costs into component-specific capital cost budgets. This measure, which we refer to as the equivalent breakeven installed cost, is the maximum budget for the technology component that leads to improved levelized costs. Finally, we perform a parametric analysis to show the impact of candidate technologies on the levelized cost of heat and, by extension, equivalent breakeven installed cost.

14 SOLAR ENERGY↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver (2 nd Ed)

High - temperature particle receivers are being pursued to enable next - generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 C) to enable more efficient power cycles, lower overall system costs, and emerging CSP - based process - heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera - based imaging methods were developed and applied to both laboratory - scale and larger 1 MW t on - sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle - sampling methods using volumetric particle - air samplers were applied to the on - sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3 - D printed tipping buckets and tethered balloons were also developed and applied to the on - sun particle - receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera - based imaging methods correlated well with measured values during the on - sun tests.

14 SOLAR ENERGY↗

Performance of a Prototype Heliostat Having a Twisting Mechanism to Maintain Focus Throughout the Day

A prototype heliostat has been designed and built with a rectangular reflector whose shape is altered automatically through the day, to maximize concentration at the receiver. The shape changes needed to form solar disc images, which give the highest possible concentration, can be realized by twisting the reflector from its corners, provided that a target-oriented, dual-axis mount is used. Then a cam mechanism connected to the second (cross) axis drive, turning with the angle of incident sunlight, may be used to twist the reflector as needed. Our prototype reflector comprises a single glass mirror, 2.4 m x 3.3 m, attached to a steel frame. Four diagonal back struts extend from the central mechanism out to the rectangular frame corners. The glass mirror of the prototype is attached to the steel frame by 58 screw actuators. Before twisting the frame, the glass shape is adjusted to the biconic shape needed to form a 1 m diameter disc image on a 113 m distant target when sunlight is incident at 60°. To form disc images over the full range of angles of incidence from 0° (normal incidence) to 70°, the struts push the corners up and down by up to 17 mm. A reflectometry metrology system has been used to set the 58 adjustment screws for the initial shape to an accuracy of ≤ 0.6 mrad, and to measure the accuracy of the different twisted shapes. The prototype will be tested at NSTTF early next year.

14 SOLAR ENERGY↗

Secondary reflectors for solar collectors and methods of making the same

A secondary reflector for receiving light from a plurality of primary reflectors that includes a reflecting surface having a length aligned along a first axis (z), where a cross-section of the reflecting surface in a plane perpendicular to the first axis (z) forms a curve comprising a concave section positioned between a first endpoint and a second endpoint, at least a portion of the concave section is accurately approximated by a polynomial equation, an aperture is formed by a straight line connecting the first endpoint to the second endpoint, and the concave section is configured to focus a plurality of beams of light passing through the aperture onto a focal point.

Zhu, Guangdong↗

Real-time dispatch optimization for concentrating solar power with thermal energy storage

Concentrating solar power (CSP) plants present a promising path towards utility-scale renewable energy. The power tower, or central receiver, configuration can achieve higher operating temperatures than other forms of CSP, and, like all forms of CSP, naturally pairs with comparatively inexpensive thermal energy storage, which allows CSP plants to dispatch electricity according to market price incentives and outside the hours of solar resource availability. Currently, CSP plants commonly include a steam Rankine power cycle and several heat exchange components to generate high-pressure steam using stored thermal energy. The efficiency of the steam Rankine cycle depends on the temperature of the plant's operating fluid, and so is a main concern of plant operators. However, the variable nature of the solar resource and the conservatism with which the receiver is operated prevent perfect control over the receiver outlet temperature. Therefore, during periods of solar variability, collection occurs at lower-than-design temperature. To support operator decisions in a real-time setting, we develop a revenue-maximizing non-convex mixed-integer, quadradically-constrained program which determines a dispatch schedule with sub-hourly time fidelity and considers temperature-dependent power cycle efficiency. The exact nonlinear formulation proves intractable for real-time decision support. Here we present exact and inexact techniques to improve problem tractability that include a hybrid nonlinear and linear formulation. Our approach admits solutions within approximately 3% of optimality, on average, within a five-minute time limit, demonstrating its usability for decision support in a real-time setting.

14 SOLAR ENERGY↗

Techno-Economic Analysis of CSP Incorporating sCO2 Brayton Power Cycles: Trade-Off Between Cost and Performance

Concentrating solar power (CSP) plants, thanks to the implementation of cost-competitive thermal energy storage, represent a dispatchable zero-emission alternative to traditional fossil fuel power plants. Next generation solar towers are expected to adopt high temperature receivers (>700 degrees C) coupled to sCO2-based power blocks, which optimal design is generally pushed towards the maximum cycle efficiency, often neglecting the economic impact with the justification that the main share of the capital cost is represented by the heliostat field. As result, the scientific literature lacks in comprehensive studies on techno-economic evaluation of CSP+sCO2 power plants addressing the important correlation that exists between system cost and performances. This work provides a preliminary techno-economic analysis of a solar power tower comparing four different cycle configurations for the sCO2 power block. Results have been reported on a Pareto front, highlighting the tradeoff between the plant investment cost and the solar-to-electricity plant efficiency. The trends of the optimization variables and cycle results have been reported to give useful insights about proper assumptions for the sCO2 power block design. The recompressed cycle with intercooling resulted as the most promising configuration and it has been further analyzed through a comparison of different solutions on the Pareto front. The cost breakdown of the sCO2 power block has been reported to highlight which components have the greatest impact on the overall plant cost and how they vary along the optimal solutions front. Eventually, the optimization has been repeated introducing a correlation to compute the turbomachinery isentropic efficiencies, to investigate their effect on the techno- economic analysis.

concentrated solar power↗

Demonstrating SolarPILOT’s Python API Through Heliostat Optimal Aimpoint Strategy Use Case

SolarPILOT is a software package that generates solar field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. SolarPILOT was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL’s1 System Advisor Model (SAM) in a simplified format. Prior means for user interaction with SolarPILOT have included the application’s graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called “LK.” This paper presents a new, full-featured, Python-based application programmable interface (API) for SolarPILOT, which we hereafter refer to as CoPylot. CoPylot provides access to all SolarPILOT’s capabilities to generate and characterize power tower CSP systems seamlessly through Python. Supported capabilities include (i) creating and destroying a model instance with message reporting tools; (ii) accessing and setting any SolarPILOT variable including custom land boundaries for field layouts; (iii) programmatically managing receiver and heliostat objects with varied attributes for systems with multiple receiver or heliostat types; (iv) generating, assigning, and modifying solar field layouts including the ability to set individual heliostat locations, aimpoints, soiling rates, and reflectivity levels; (v) simulating solar field performance; (vi) returning detailed results describing performance of individual heliostats, the aggregate field, and receiver flux distribution; and, (vii) exporting Python-based model instances to multiple file formats. CoPylot enables Python users to perform detailed CSP tower analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. In addition to CoPylot’s functionality, Python users have access to the over 100,000 open-source libraries to develop, analyze, optimize, and visualize power tower CSP research. This enables CSP researchers to perform analysis that was previously not possible through SolarPILOT’s existing interfaces. This paper discusses the capabilities of CoPylot and presents a use case wherein we demonstrate optimal solar field aiming strategies.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Performance Assessment of Pakistani Central Receiver Plant Case Study Using Aimpoint Strategy Optimization Tools

Pakistan has a high potential for both photovoltaic and Concentrated Solar Power (CSP) deployment to meet its energy requirements. Previous feasibility studies have shown that a variety of CSP technologies are both technically and economically viable in the Pakistani climate and can significantly mitigate the country's current lack of grid reliability. This work aims to enhance the performance of a previously designed Central Receiver System (CRS) plant for Pakistan using state-of-the-art aimpoint optimization methods. Results from our case study show that optimized aiming strategies have increased practicality due to their adherence to flux limitations on the receiver, and offer ~2.4% more thermal energy delivered to the receiver for the Pakistani case study compared to modern performance characterization software, translating to up to 149 additional hours of nameplate-capacity production to address the shortfall in an electricity-starved market.

central receiver system↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Particle Receiver Models for Systems Analysis

Particle receivers are gaining importance in the field of Concentrating Solar Power (CSP) due to the high temperature that particles can achieve without degradation. Several researchers are studying the potential of this technology by means of system analyses, which need simple and light models of the system. This study presents two simple models for the particle receiver. The simplest model is a correlation obtained by fitting the results calculated with a more complex receiver model simulated in CFD. The other model is a 1D model, which is benchmarked against the same CFD results. Although both models achieve high coefficient of determination, R2, when compared to CFD results, the 1D model seems to provide more accurate results (especially during sunsets and sunrises). Both models are integrated into a tecno-economic model developed in previous work. The LCOE obtained with the 1D model is between 7% and 10% greater than the one obtained with the correlation.

González-Portillo, Luis F. (ORCID:0000000348643825↗