Search NASASearch

SEARCH · Search NASA

Results for “Spaceflight experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

227 records · Page 13

Wide-Bandgap Semiconductor Amplifiers for Fusion Plasma Heating and Control

This paper discusses power electronics developed under the ARPA-E GAMOW program to support nuclear fusion power production. The goal of this project was to develop and assess the potential for wide-bandgap (WBG) semiconductor devices in power electronics to enable high-efficiency and high-voltage solid-state systems for fusion plasma generation, heating, and control. The power electronics use an architecture in which multiple high-power boards can be combined to produce megawatt-level power, where using multiple boards provides high reliability. Two main areas of power electronics boards are developed in this project for fusion plasma heating and control applications: (1) pulse generation and control and (2) radiofrequency generation. The first area is for boards capable of driving high-voltage millisecond pulses at high duty cycles. The envisioned application of these pulses is in plasma control of magnetohydrodynamic instabilities, plasma position, and edge-localized modes. Pulse-width modulation allows for the implementation of a wide variety of linear and nonlinear control systems. The boards developed for this project could actuate control coils based on digital input signals and can be parallelized to provide megawatts of output power. The design of the pulse generator is a low-side load switch. A load switch was designed and constructed that utilized 2-kV-rated field-effect transistor (FET)-based cascodes developed by Qorvo under this project to perform initial testing of these cascodes. The second area is being implemented using class E amplifiers with WBG devices and a reactance steering network to handle inductive or capacitive plasma loads. Applications include ion cyclotron resonance heating (ICRH) and high-harmonic fast-wave (HHFW) heating. A class E reactance steering network is demonstrated in modeling and experiment with a resistive-inductive load that models an inductively-coupled plasma. Power combining of boards with class E reactance steering networks is also simulated and demonstrated experimentally, to enable scaling up to high power. Modeling of high-power-density cooling and remaining useful life is conducted to enable reliable, effectively cooled high-power electronics for fusion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

Wetter, Michael [Lawrence Berkeley National Labora

Erosion of high-Z refractory coatings for helicon plasma source window

Proto-MPEX (Materials Plasma Exposure eXperiment), a linear plasma device (LPD), using a high power radio frequency (RF) (⩾100 kW, 13.56 MHz) helicon plasma source, has suffered RF sheath-induced window erosion. The sputtered impurities from the window surface transport toward the downstream target affecting plasma-material interaction studies. The rectified sheath voltage formed was high enough to cause window erosion by light ions due to its low-Z components (e.g. Si 3 N 4 and AlN). Hence, we are proposing impurity mitigation strategies, which involve the application of a Faraday screen to lower the rectified sheath voltage and the application of high-Z refractory coatings on the existing window plasma-facing surface. In this work, we report the erosion of two different coatings, i.e., tantalum oxide (Ta 2 O 5 ) and hafnium oxide (HfO 2 ) on a silicon nitride (Si 3 N 4 ) window material under conditions of low-energy deuterium (D) ion impact, well below the Ta 2 O 5 sputtering energy threshold (i.e. 250 eV). The test samples were RF-biased and exposed to a high D-ion fluence (∼10 26 m −2 ) in Plasma Interaction with Surface Component Experimental Station (PISCES-A) LPD. The experimentally measured sputtering yields of the high-Z refractory coatings below the sputtering energy threshold of Ta 2 O 5 indicate an increased erosion due to the plasma impurities, especially due to oxygen. Improving the vacuum level could reduce the oxygen impurities and increase the lifespan of the coated helicon window for plasma operation. Post-surface analysis indicates no preferential erosion of oxygen or enrichment of the high-Z surface component. This is likely due to an effective energy transfer from the impurity ion for sputtering of the high-Z component in the coating. With the reduced rectified sheath voltage at the window surface and improved vacuum conditions, the proposed high-Z refractory coatings offer a promising solution for reducing window erosion in future MPEX plasma operations at ORNL.

RF bias

String-Breaking Dynamics in Quantum Adiabatic and Diabatic Processes

Confinement prohibits isolation of color charges, e.g., quarks, in nature via a process called string breaking : the separation of two charges results in an increase in the energy of a color flux, visualized as a string, connecting those charges. Eventually, creating additional charges is energetically favored, hence breaking the string. Such a phenomenon can be probed in simpler models, including quantum spin chains, enabling enhanced understanding of string-breaking dynamics. A challenging task is to understand how string breaking occurs as time elapses, in an out-of-equilibrium setting. This work establishes the phenomenology of dynamical string breaking induced by a gradual increase of string tension over time. It, thus, goes beyond instantaneous quench processes and enables tracking the real-time evolution of strings in a more controlled setting. We focus on domain-wall confinement in a family of quantum Ising chains. Our results indicate that, for sufficiently short strings and slow evolution, string breaking can be described by the transition dynamics of a two-state quantum system akin to a Landau-Zener process. For longer strings, a more intricate spatiotemporal pattern emerges: the string breaks by forming a superposition of bubbles (domains of flipped spins of varying sizes), which involve highly excited states. We finally demonstrate that string breaking driven only by quantum fluctuations can be realized in the presence of sufficiently long-ranged interactions. This work holds immediate relevance for studying string breaking in quantum-simulation experiments.

Ising model

Observational evidence for Criegee intermediate oligomerization reactions relevant to aerosol formation in the troposphere

Criegee intermediates are reactive intermediates that are implicated in transforming the composition of Earth’s troposphere and in the formation of secondary organic aerosol, impacting Earth’s radiation balance, air quality and human health. Yet, direct identification of their signatures in the field remains elusive. Here, from particulate and gas-phase mass-spectrometric measurements in the Amazon rainforest, we identify sequences of masses consistent with the expected signatures of oligomerization of the CH 2 OO Criegee intermediate, a process implicated in ozonolysis-driven aerosol formation. In this study, we assess the potential contributions of oligomerization through laboratory ozonolysis experiments, direct kinetic studies of Criegee intermediate reactions, and high-level theoretical calculations. Global atmospheric models built on these kinetics results indicate that Criegee intermediate chemistry may play a larger role in altering the composition of Earth’s troposphere than is captured in current atmospheric models, especially in areas of high humidity. However, the models still capture only a relatively small fraction of the observed signatures, suggesting considerable underestimates of Criegee intermediate concentrations and reactivity and/or the dominance of other, presently uncharacterized, oxidation mechanisms. Resolving the remaining uncertainties in emission inventories and the effects of atmospheric water vapour on key chemical reactions will be required to definitively assess the role of Criegee intermediate oligomerization reactions.

58 GEOSCIENCES

UCB-GLOBES: An open-access mass spectral database of identified and unidentified atmospheric organic compounds

Chemical characterization of atmospheric organic aerosols using gas chromatography with 70 eV electron ionization mass spectrometry (GC/EI-MS) has been used for decades in advancing molecular marker detection and identification, though primarily through suspect screening and/or targeted analyses. To advance non-targeted analyses of environmental samples, we have catalogued approximately 27 000 mass spectra (MS) of the trimethylsilyl derivatives of semi-volatile organic aerosol (OA) analytes in the open-access University of California Berkeley Goldstein Library of Organic Biogenic Environmental Spectra (UCB-GLOBES). Analytes were observed in ambient samples from the U.S. and the Central Amazon and/or laboratory simulations of secondary OA (SOA) formation. These samples are representative of OA under urban and biomass burning influences as well as SOA derived from biogenic precursors (e.g., isoprene, monoterpenes, sesquiterpenes) and biomass burning intermediates. MS are documented in UCB-GLOBES without regard to known chemical identity, annotated with extensive metadata such as sample source/experimental conditions, any structural information gained from MS analyses, and predicted chemical properties such as average carbon oxidation state and carbon number. UCB-GLOBES MS are compatible for importing into the NIST MS Search program, and we have also provided a Jupyter Notebook for MS visualization and comparisons. We demonstrate the utility of UCB-GLOBES through MS reanalyses of prior analytes observed in ambient data, finding a 20 % reduction in the number of analytes assigned to OA source categories reliant solely on time series correlation and an overall 11 % increase in new MS-based OA source categorization for the Southeast U.S. For 1513 analytes observed previously in the Central Amazon, we found 375 MS matches using UCB-GLOBES vs. 136 MS matches during prior analyses, representing a 14 % gain in newly confirmed or newly categorized OA species. While OA from laboratory oxidation experiments in UCB-GLOBES are highly diverse chemically, on average only 29 % of UCB-GLOBES MS have a mass spectral match to another MS entry in UCB-GLOBES and/or in databases of known compounds (i.e. NIST MS Database, Adams Essential Oil, MANE Flavor and Fragrance Company). This indicates that roughly 70 % of UCB-GLOBES MS are unique thus far, not observed more than once among the laboratory oxidation samples and ambient data in UCB-GLOBES MS. Further, only 18 % can be positively identified using these databases or known authentic standards. This points to a large gap between these laboratory simulations and ambient OA. Overall, the UCB-GLOBES database can be utilized for improving confidence in OA source categorization and/or identification, novel chemical marker discovery, tracking chemical diversity, de novo structure and properties prediction, and improving MS search and matching algorithms. This can ultimately inform future research priorities for the chemical characterization of atmospheric organic samples.

Mass spectrometry

Laser–plasma amplification of an ultrabroadband laser pulse to 0.3 TW

Producing on-target laser intensities much greater than 10 23 W cm −2 with current laser technologies is a roadblock to accessing new regimes of physics such as strong-field quantum electrodynamics. Laser–plasma amplifiers show promise to realize these intensities by augmenting the final amplifier and compressor in traditional chirped-pulse-amplification architectures with a plasma-based amplification and compression stage that operates at a much higher damage threshold. Here we demonstrate amplification of an ultrabroadband (>60 nm) pulse in a laser–plasma Raman amplifier. We directly amplified seed intensities up to 3.7 × 10 15 W cm −2 and measured efficiencies up to 8.7%. Single-shot SPIDER measurements show a factor-of-2 reduction in the amplified pulse duration with final powers up to 0.3 TW, a 10× improvement over previous results. Final pulse durations of 64 fs are measured. Energy transfers greater than 220 mJ from the picosecond pump into the seed result in a 30× energy amplification of a 7.6 mJ seed. These results set the stage for a compact plasma afterburner based on Raman amplification that could extend the scientific capability of existing petawatt-class laser facilities to enable experiments at the intensity frontier.

Shaw, J. L. [Univ. of Rochester, NY (United States

Gear Test Assembly - Experimental Testing and Analysis of Gears and Bearings - FY2026

The Gear Test Assembly (GTA) is an experimental test apparatus built and installed in the Mechanisms and Engineering Test Loop (METL) at Argonne National Laboratory (ANL). While designed to accommodate a variety of components intended for use in advanced compact in-vessel transfer machine, the focus of GTA been the testing of large radial spur gears. The performance of the components used in GTA motivates the choices made in the design, components, and material choices for the forthcoming METL test articles; the Gripper Test Assembly (GrTA), and the Bearing Test Assembly (BTA). To date, GTA has completed nine experimental testing campaigns and achieved over 21 million revolutions under prototypic sodium fast reactor loads and operating conditions. This report provides an overview and results for the two most recent experiments Campaign #8 and Campaign #9. `Campaign #8 was the first campaign to make use of a set of nickel alloy radial spur gears, made from Hastelloy C-22HS, and combined with heat-treated tapered roller bearings. The bearings and torque profile used allowed Campaign #8 to be directly compared with Campaign #1 where Inconel 718 gears were used instead. Campaign #8 attained 1,058,880 shaft revolutions within 23% of the 1,314,855 revolutions achieved in Campaign #1. These results demonstrate that the heat-treated tapered roller bearings show consistent increased lifetimes, approximately three times longer than for non heat-treated taper rollers, and that the particular material of the gear does not play a substantial role in performance. Similar to Campaign #7 where bearing failure resulted in fragmentation and transport of bearing material into the gear teeth led to tooth damage in the Inconel gears, a similar process led to the damage of the Hastelloy gears. Subsequent NDE analysis showed that the damage was only limited to the tooth surface and does not extend into the gear interiors. Based on the NDE reports, the Hastelloy gears can be reconditioned and put back into service for future campaigns as was done for the Inconel gears. Reconditioned Inconel 718 gears damaged in Campaign #7 were returned to service in Campaign #9 and paired with non heat-treated tapered roller bearings. In Campaign #9 a novel set of operating conditions were implemented whereby the gears and bearings were cycled between hot, submerged refueling conditions where fuel handling operations occurred and cold, dry, and inert conditions where the sodium was drained and the vessel was allowed to cool simulating long, ex-vessel storage of the fuel handling machine. A total of eight of these operating cycles were achieved before a bearing failure occurred after the accumulation of 475,692 shaft revolutions were achieved. During Campaign #9, one of the drive motors was damaged and over the course of a 240 day standby period, the entire GTA drive system was upgraded from a 480VAC system to a 240VAC system that provided the opportunity to consolidate wall-space in the METL facility and provide more space for additional test articles being installed in the coming year. The over 475,000 shaft revolutions achieved in Campaign #9 eclipses the previous record for lifetime of non heat-treated tapered roller bearings held by Campaign #3 of 392,000 shaft revolutions. Further analysis and future campaigns hope to shed light on the cause of this approximately 17% increase in lifetime.

42 ENGINEERING

The MuFusE large-volume diamond anvil cell for exploring muon-catalyzed fusion at higher pressures and temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion (μCF) Experiment (MuFusE), enabling the compression and heating of deuterium–tritium (d–t) mixtures to pressures and temperatures needed to advance μCF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm 3 at liquid density, pressures up to 933 MPa and temperatures up to 400 K—benchmarks that significantly exceed previously reported limits for static d–t targets.

Kalow, J. D. [Acceleron Fusion, Inc., Cambridge, M

HydraGNN_Predictive_GFM_2026 - Ensemble of predictive graph foundation models for atomistic materials modeling

This release contains data and parameters of HydraGNN-based graph foundation models trained as a result of the work published in the pre-print "Exascale Multi-Task Graph Foundation Models for Imbalanced, Multi-Fidelity Atomistic Data" by M. Lupo Pasini et al. (https://arxiv.org/abs/2604.15380). We jointly train on 16 open first-principles datasets (544+ million structures covering 85+ elements) using a multi-task architecture with per-dataset heads and a scalable ADIOS2/DDStore data pipeline. On Frontier, we execute six large-scale DeepHyper hyperparameter optimization campaigns in FP64 and promote the top-performing message-passing models to sustained 2,048-node training, yielding a PaiNN-based lead model. The version of HydraGNN used to generate the outputs provided in this release is HydraGNN v5.0 (https://github.com/ORNL/HydraGNN/releases/tag/v5.0) The list of datasets used for the training of the graph foundation model is the following: 1) Alexandria [1] 2) ANI1x [2] 3) MPTrj [3] 4) Open Catalyst 2020 (OC20) [4] 5) Open Catalyst 2022 (OC22) [5] 6) Open Catalyst 2025 (OC25) [6] 7) Open Direct ir Capture 2023 (ODAC23) [7] 8) Open Materials 2024 (OMat24) [8] 9) Open Molecules 2025 (OMol25) [9] 10) OMol25-neutral (subset of OMol25 that contains only molecules with zero total charge) 11) OMol25-non-neutral (subset of OMol25 that contains only molecules with non-zero total charge) 12) Open Polymers 2026 (OPoly2026) [10] 13) Nabla2DFT [11] 14) QCML [12] 15) QM7X [reference 13] 16) transition1x [14] Dataset references: [1] J. Schmidt et al., “A dataset of 175k stable and metastable materials calculated with the PBEsol and SCAN functionals,” Scientific Data, vol. 9, p. 64, 2022. [2] J. S. Smith et al., “The ANI-1ccx and ANI-1x data sets, coupled-cluster and density functional theory properties for molecules,” Scientific Data, vol. 7, p. 134, 2020. [Online]. Available: https: //www.nature.com/articles/s41597-020-0473-z [3] A. Jain et al., “Commentary: The Materials Project: A materials genome approach to accelerating materials innovation,” APL Materials, vol. 1, no. 1, p. 011002, 07 2013. [Online]. Available: https://doi.org/10.1063/1.4812323 [4] L. Chanussot et al., “Open catalyst 2020 (oc20) dataset and community challenges,” ACS Catalysis, vol. 11, no. 10, pp. 6059–6072, 2021. [Online]. Available: https://doi.org/10.1021/acscatal.0c04525 [5] K. Tran et al., “Open catalyst 2022 (oc22) dataset and challenges for oxidation electrocatalysts,” ACS Catalysis, vol. 13, no. 5, pp. 3066–3084, 2023. [Online]. Available: https://doi.org/10.1021/acscatal.2c05426 [6] S. J. Sahoo et al., “The open catalyst 2025 (oc25) dataset and models for solid-liquid interfaces,” arXiv preprint arXiv:2509.17862, 2025. [Online]. Available: https://arxiv.org/abs/2509.17862 [7] A. Sriram et al., “The open DAC 2023 dataset and challenges for sorbent discovery in direct air capture,” ACS Central Science, vol. 10, no. 5, pp. 923–941, 2024. [8] L. Barroso-Luque et al., “Open materials 2024 (omat24) inorganic materials dataset and models,” 2024. [Online]. Available: https://arxiv.org/abs/2410.12771 [9] D. S. Levine et al., “The open molecules 2025 (OMol25) dataset, evaluations, and models,” 2025. [Online]. Available: https://arxiv.org/abs/2505.08762 [10] D. S. Levine et al., The open polymers 2026 (OPoly26) dataset and evaluations,” arXiv preprint arXiv:2512.23117, 2025. [Online]. Available: https://arxiv.org/abs/2512.23117 [11] K. Khrabrov et al., “Nabla2dft: A universal quantum chemistry dataset of drug-like molecules and a benchmark for neural network potentials,” in NeurIPS 2024 Datasets and Benchmarks Track, 2024. [Online]. Available: https://openreview.net/forum?id=ElUrNM9U8c [12] S. Ganscha et al., “The QCML dataset, quantum chemistry reference data from 33.5M DFT and 14.7B semi-empirical calculations,” Scientific Data, vol. 12, p. 406, 2025. [13] J. Hoja et al., “QM7-X, a comprehensive dataset of quantum-mechanical properties spanning the chemical space of small organic molecules,” Scientific Data, vol. 8, p. 43, 2021. [Online]. Available: https://www.nature.com/articles/s41597-021-00812-2 [14] M. Schreiner et al., “Transition1x - a dataset for building generalizable reactive machine learning potentials,” Scientific Data, vol. 9, p. 779, 2022. The folder "datasets_ADIOS2_format" contains the set of pre-processed datasets in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used for the development and training of GFMs in this work. The "datasets_ADIOS2_format" directory contains 2 sub-directories, one for the version "v1" of the datasets and one for the version "v2" of the datasets. The version "v1" of the datasets provides values of the total energy as they are extracted from the original data as it was released by the respective institutions. The version "v2" of the datasets provides values of the energy that have been realigned. The realignment was performed by training a linear regression model that predicts the total energy as a function of the chemical composition of the atomistic structure, and then subtract such prediction from the original value of the total energy. Both folders "v1" and "v2" contain 16 sub-directories, each corresponding to an ADIOS2-formatted dataset The folder "DeepHyper-results" contains the configurational files and model's parameters for all the 186 HPO trials that were successfully completed by the scalable hyperparameter optimization (HPO) runs on Frontier. The content of the folder "DeepHyper-results" I structured as follows: 1) task-list.txt: list of mpnn name, jobid, and deephyper task id 2) gfm_${MPNN}_${JOBID}_0.${TASKID}: run directory with checkpoint files 3) gfm_${MPNN}: deephyper summary directory (*.csv) for each specific MPNN type 4) deephyper-experiment-${JOBID}: output and error logs for each job The file "deephyper-sorted.csv" contains the details of each HydraGNN model built and tested by HPO, obtained by merging the (*.csv) filed from each HPO run executed. Out of all the HPO trials, we selected 10 to continue the training of the respective HydraGNN models. Due to limited computational budget available in the LRN070 allocation we could not complete the training till convergence for all these 10 selected models. The folder "models" contains multiple sub-folders, one per each HydraGNN model trained. Each model sub-folder contains the parameters of each HydraGNN model, with multiple checkpoint-restarts. The list of sub-folders are as follows: 1) multidataset_hpo-BEST1-fp64 2) multidataset_hpo-BEST2-fp64 3) multidataset_hpo-BEST3-fp64 4) multidataset_hpo-BEST4-fp64 5) multidataset_hpo-BEST5-fp64 6) multidataset_hpo-BEST6-fp64 7) multidataset_hpo-BEST7-fp64 8) multidataset_hpo-BEST8-fp64 9) multidataset_hpo-BEST9-fp64 10) multidataset_hpo-BEST10-fp64 Within each one of these folders, additional auxiliary log files are provided with descriptions about how the training proceeded. The lead PaiNN-model is contained inside "multidataset_hpo-BEST6-fp64". The file "mlp_branch_weights" contains the parameters of the multi-layer perceptron (MLP) used to reconcile the predictions of the 16 output decoding heads of the HydragNN architectures. The MLP takes in input the chemical composition of the atomistic structure and predicts averaging weights to linearly mix the predictions of each output decoding head toward consolidating them into a single one. The folder "1.1billion-structure-inference" contains 1.1 billion atomistic structures randomly generated. Each structures is associated with energy and forces predicted with the lead-PaiNN model combined with the MLP model for reconciliation of the multi-branch predictions generated by the 16 output decoding heads. The folder "1.1billion-structure-inference" contains 9,300 (*.tar.gz) subdirectories, one per Frontier compute node used to execute the inference at exascale. Once uncompressed, each (*.tar.gz) subdirectory contains an ADIOS2 (*.bp) file container, where each atomistic structure is stored as a PyTorch-Geometric Data object. The file "export_dataset_environment_variables.sh" contains the environment variables that need to be set before running the HydraGNN code to reproduce the results provided in this dataset release. The code that can be used to load the ADIOS2 files, load HydraGNN models, and run inference is available at: https://github.com/ORNL/HydraGNN/releases/tag/v5.0

36 MATERIALS SCIENCE

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI