Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral element”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Resolution-enhanced Mapping Spectrometer

A familiar mapping spectrometer implementation utilizes two dimensional detector arrays with spectral dispersion along one direction and spatial along the other. Spectral images are formed by spatially scanning across the scene (i.e., push-broom scanning). For imaging grating and prism spectrometers, the slit is perpendicular to the spatial scan direction. For spectrometers utilizing linearly variable focal-plane-mounted filters the spatial scan direction is perpendicular to the direction of spectral variation. These spectrometers share the common limitation that the number of spectral resolution elements is given by the number of pixels along the spectral (or dispersive) direction. Resolution enhancement by first passing the light input to the spectrometer through a scanned etalon or Michelson is discussed. Thus, while a detector element is scanned through a spatial resolution element of the scene, it is also temporally sampled. The analysis for all the pixels in the dispersive direction is addressed. Several specific examples are discussed. The alternate use of a Michelson for the same enhancement purpose is also discussed. Suitable for weight constrained deep space missions, hardware systems were developed including actuators, sensor, and electronics such that low-resolution etalons with performance required for implementation would weigh less than one pound.

Kumer, J. B.↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

Establishing an isoelectronic line ratio temperature diagnostic for soft X-ray absorption spectroscopy

For diagnosing temperatures of high-energy-density plasmas, relying on the ratio of a pair of isoelectronic spectral lines provides the alternative of ‘‘matched charge-state transits in different elements’’ to the more conventional, ‘‘unmatched charge-state transits in the same-element’’ spectral-line-ratio technique. In contrast to a novel previous establishment of isoelectronic emission-line ratio determination of plasma temperature, this report determines plasma temperature from the ratio of isoelectronic absorption spectral line pairs. Here, the feasibility of this technique is assessed from experimentally acquired transmission spectra, spanning the 7– 15 Å range, through a 0.4 μm MgO-NaF foil, tamped with CH, x-ray-radiation heated by a z-pinch dynamic hohlraum (ZPDH), and backlit by the brief X-ray burst upon imploding-wire stagnation on the Z pulsed-power facility at Sandia National Laboratories. As expected from the slight difference between interstage and isoelectronic absorption processes, a quantitative comparison between the value of isoelectronic-absorption-derived temperature and the value of inter-stage-absorption-derived temperature is shown to yield a well correlated, slight difference in inferred values of plasma temperature associated with local thermodynamic equilibrium.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics

In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Fraenkel, M. (ORCID:0000000291939544)↗

The Magellan Evolution of Galaxies Spectroscopic and Ultraviolet Reference Atlas (MegaSaura). II. Stacked Spectra

We stack the rest-frame ultraviolet spectra of N = 14 highly magnified gravitationally lensed galaxies at redshifts 1.6 < z < 3.6. The resulting new composite spans 900 < lambda rest < 3000 Angstrom, with a peak signal-to-noise ratio of 103 per spectral resolution element (approximately 100 km s (exp -1)). It is the highest signalto-noise ratio, highest spectral resolution composite spectrum of z approximately 2-3 galaxies yet published. The composite reveals numerous weak nebular emission lines and stellar photospheric absorption lines that can serve as new physical diagnostics, particularly at high redshift with the James Webb Space Telescope (JWST). We report equivalent widths to aid in proposing for and interpreting JWST spectra. We examine the velocity profiles of strong absorption features in the composite, and in a matched composite of z approximately 0 COS/HST galaxy spectra. We find remarkable similarity in the velocity profiles at z approximately 0 and z approximately 2, suggesting that similar physical processes control the outflows across cosmic time. While the maximum outflow velocity depends strongly on ionization potential, the absorptionweighted mean velocity does not. As such, the bulk of the high-ionization absorption traces the low-ionization gas, with an additional blueshifted absorption tail extending to at least approximately 2000 km s (exp -1). We interpret this tail as arising from the stellar wind and photospheres of massive stars. Starburst99 models are able to replicate this high-velocity absorption tail. However, these theoretical models poorly reproduce several of the photospheric absorption features, indicating that improvements are needed to match observational constraints on the massive stellar content of star-forming galaxies at z approximately 2. We publicly release our composite spectra.

Rigby, J. R.↗

The use of large-scale aerial photography for interpreting Landsat digital data in an elk habitat-analysis project

Large-scale aerial photography was used to interpret Landsat multispectral scanner data processed through an unsupervised classifier. After scale adjustment and interpretation by application of an elk-habitat photointerpretation legend, the photographs were registered with the spectral classification, and the co-occurrence of spectral picture elements with photointerpreted habitat classes was tabulated. Analysis of the resulting table of data permitted the description of spectral classes in terms meaningful and useful to elk research and management unit in the Blue Mountains of northeastern Oregon.

Isaacson, D. L.↗

Spectral Equivalence Properties of Higher-Order Tensor Product Finite Elements and Applications to Preconditioning

In this study, we present spectral equivalence results for higher-order tensor product edge-, face- and interior-based finite elements. Specifically, we show for certain choices of shape functions that the mass and stiffness matrices of the higher-order elements are spectrally equivalent to those for an assembly of lowest-order elements on the associated Gauss-Lobatto-Legendre mesh. Based on this equivalence, efficient preconditioners can be designed with favorable computational complexity. Numerical results are presented which confirm the theory and demonstrate the benefits of the equivalence results for overlapping Schwarz preconditioners.

97 MATHEMATICS AND COMPUTING↗

Spectral Peak Enhancement by Combining Trusted Response Elements via Machine Learning (SPECTRE-ML) v0.8.0

SPECTRE-ML (Spectral Peak Enhancement by Combining Trusted Response Elements via Machine Learning) is a machine learning based program for finding optimal clusters of radiation detector segments (i.e., pixels or voxels) in order to improve spectral performance. It provides facilities for pre-processing and analyzing training datasets, running ML algorithms, and evaluating and visualizing outputs. SPECTRE-ML outperforms simpler ad-hoc segmentation methods such as uniform depth clusters, learning detector performance trends such as dead layers, edge effects, and gain shifts. Although extensible to arbitrary highly-segmented spectroscopic radiation detectors, SPECTRE-ML currently focuses on improving spectral performance in highly-segmented CdZnTe (CZT) detectors for International Atomic Energy Agency (IAEA) non-destructive assay (NDA) safeguards tasks.

Vavrek, Jayson↗

Optical Reflection Spectroscopy of GEO Objects

We report on optical reflection spectroscopy of geosynchronous (GEO) objects in the US Space Surveillance Network (SSN) catalog. These observations were obtained using imaging spectrographs on the 6.5-m Magellan telescopes at the Las Campanas Observatory in Chile. Our goal is to determine the composition of these objects by comparing these spectral observations with ground-based laboratory measurements of spacecraft materials. The observations are all low resolution (1 nm after smoothing) obtained through a 5 arcsecond wide slit and using a grism as the dispersing element. The spectral range covered was from 450 nm to 800 nm. All spectra were flux calibrated using observations of standard stars with the exact same instrumental setup. An effort was made to obtain all observations within a limited range of topocentric phase angle, although the solar incident angle is unknown due to the lack of any knowledge of the attitude of the observed surface at the time of observation.

Seitzer, Patrick↗

Lines in the 2736-3303 A spectrum of Arcturus

Results are reported for a study of the near-UV spectrum of Arcturus as recorded with a balloon-borne echelle spectrograph-vidicon detector system in the spectral region from 2700 to 3300 A at 0.1-A resolution. A condensed version of the Arcturus spectrum is provided along with profile descriptions and identifications for 383 absorption features detected in the near-UV. Elements definitely present include Na, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Sr, Zr, and La. Elements with spectral features indicating possible presence include Be, O, S, K, Ga, Ge, Nb, Sn, Gd, and Bi. Line blocking is shown to be extensive in the spectral region studied, and eight possible continuum 'windows' are found in the near-UV. Emission lines of chromospheric origin due to Mg II, Fe I, Fe II, and possibly Cr II are also identified in the region from 2736 to 3303 A. It is noted that the Fe I emission lines at 2823 and 2844 A are optically pumped.

Stencel, R. E.↗

Dye laser tuning with pellicles.

Thin nitrocellulose membranes (pellicles) are shown to exhibit properties which make them suitable for intracavity tuning elements in high-energy pulsed dye lasers. Uncoated pellicles of 2-micron and 8-micron thickness with surface figures of lambda/1 are shown to closely approximate the properties of low-finesse etalons with wide free spectral ranges. Pellicles of 8-micron thickness, coated on both surfaces with 50% reflectivity multilayer dielectrics, are shown to be effective as spectral narrowing elements with peak transmission greater than 80% and resultant laser linewidths of 0.57 nm full width at half-maximum.

Mumola, P. B.↗

The moderately interacting Algol binary RS Cephei

In agreement with previous observers, it is found that the eclipsing binary RS Cep is an Algol-type semidetached system. From IUE spectra and Lick Observatory optical scans, the spectral types of the components are determined as B9.7e V + G8 III-IV. The effective temperature of the primary star is found to be 9670 K (with an uncertainty of about 150 K). From the photometric elements, the spectral types, and the semidetached nature of the system, a satisfactory model of the system is developed, giving masses 2.4 and 0.4 solar mass, radii 2.3 and 7.6 solar radii, and separation of the components 32 solar radii. This model leads to a distance of 910 pc; the color excess is E(B - V) = 0.03 mag. Balmer emission lines are observed in the optical scans, so that the system is a Be star. An IUE spectrum obtained during the total primary eclipse reveals a number of UV emission lines, typical for interacting Algols and W Ser stars. Power emitted in these lines is about twice as high as that in TT Hya or U Cep, therefore, RS Cep is a relatively active Algol system. A broad 'bulge' of excess relative flux is observed roughly between wavelengths 210 and 270 nm in the totality spectrum, and interpreted as broad blends of emission lines of Fe II; the same Fe II lines, formed in a circumstellar shell or disk, cause additional absorption in the out-of-eclipse spectra.

Plavec, Mirek J.↗

The Advanced Spectral Library (ASTRAL): Abundance Analysis of the Chemically Peculiar Star HR 465

This paper presents the results of the spectrum analysis of the B-type magnetic chemically peculiar star HR 465. HR 465 shows unusual abundance patterns that vary with a period of 21.5 yr. Our observations are recorded at ϕ = 0.45, 0.68, and 0.85 of the spectroscopic period, where ϕ = 0 represents the phase of maximum flux in the photometric y-band. Synthetic spectra, computed using an LTE atmosphere model, are fit to high-resolution ultraviolet Hubble Space Telescope (ϕ = 0.45) spectra obtained as part of the Advanced Spectral Library Project: Hot Stars program. The ultraviolet data are supplemented by high-resolution optical spectra (ϕ = 0.68 and 0.85) recorded at the Nordic Optical Telescope with the SOFIN spectrograph. The optical data are used as a complement to the high line-density ultraviolet spectrum to derive accurate abundances for elements without spectral lines in the ultraviolet and to improve the abundance phase coverage for many atoms/ions. This analysis presents abundance results for more than 70 atoms/ions and confirms parts of the abundance characteristics previously reported where elements with high mass numbers show significant abundance enhancements compared with solar values while some of the lighter elements show abundance deficiencies. In addition, our measured abundances are consistent with the periodic variability for chromium and rare-earth elements. Our results are compared with earlier investigations of this peculiar object to constrain stellar abundance and diffusion.

Krister E. Nielsen↗

Energy Finite Element Analysis Developments for Vibration Analysis of Composite Aircraft Structures

The Energy Finite Element Analysis (EFEA) has been utilized successfully for modeling complex structural-acoustic systems with isotropic structural material properties. In this paper, a formulation for modeling structures made out of composite materials is presented. An approach based on spectral finite element analysis is utilized first for developing the equivalent material properties for the composite material. These equivalent properties are employed in the EFEA governing differential equations for representing the composite materials and deriving the element level matrices. The power transmission characteristics at connections between members made out of non-isotropic composite material are considered for deriving suitable power transmission coefficients at junctions of interconnected members. These coefficients are utilized for computing the joint matrix that is needed to assemble the global system of EFEA equations. The global system of EFEA equations is solved numerically and the vibration levels within the entire system can be computed. The new EFEA formulation for modeling composite laminate structures is validated through comparison to test data collected from a representative composite aircraft fuselage that is made out of a composite outer shell and composite frames and stiffeners. NASA Langley constructed the composite cylinder and conducted the test measurements utilized in this work.

Vlahopoulos, Nickolas↗

The ultraviolet emission properties of five low-redshift active galactic nuclei at high signal-to-noise ratio and spectral resolution

We analyze the ultraviolet (UV) emission line and continuum properties of five low-redshift active galactic nuclei (four luminous quasars: PKS 0405-123, H1821 + 643, PG 0953 + 414, and 3C 273, and one bright Seyfert 1 galaxy: Mrk 205). The HST spectra have higher signal-to-noise ratios (typically approximately 60 per resolution element) and spectral resolution (R = 1300) than all previously published UV spectra used to study the emission characteristics of active galactic nuclei. We include in the analysis ground-based optical spectra covering H beta and the narrow (O III) lambda lambda 4959, 5007 doublet. New results are obtained and presented.

Laor, Ari↗

High energy yield bifacial spectrum-splitting photovoltaic system

In this paper a photovoltaic system is proposed that achieves high energy yield by integrating bifacial silicon cells into a spectrum-splitting module. Spectrum splitting is accomplished using volume holographic optical elements to spectrally divide sunlight onto an array of photovoltaic cells with different bandgap energies. Light that is reflected from the ground surface onto the rear side of the module is converted by the bifacial silicon cells. The energy yield of the system is optimized by tuning the volume holographic element parameters, such as film thickness, index modulation, and construction point source positions. An example is presented for utility-scale illumination parameters in Tucson, Arizona, that attains an energy yield of 1010 k w ⋅ <#comment/> h r y r ⋅ <#comment/> m 2 , which is 32.8% of the incident solar insolation.

Chrysler, Benjamin D. (ORCID:0000000186250147)↗

A Fast Solver for the Fractional Helmholtz Equation

The purpose of this paper is to study a Helmholtz problem with a spectral fractional Laplacian, instead of the standard Laplacian. Recently, it has been established that such a fractional Helmholtz problem better captures the underlying behavior in Geophysical Electromagnetics. In this work, we establish the well-posedness and regularity of this problem. We introduce a hybrid spectral-finite element approach to discretize it and show well-posedness of the discrete system. In addition, we derive a priori discretization error estimates. Finally, we introduce an efficient solver that scales aswell as the best possible solver for the classical integer-order Helmholtz equation. We conclude withseveral illustrative examples that confirm our theoretical findings.

97 MATHEMATICS AND COMPUTING↗

Real-time simulation of dynamically deformable finite element models using modal analysis and spectral Lanczos decomposition methods

We present two efficient methods for simulating real-time behavior of a dynamically deformable 3D object modeled by finite element equations. The first method is based on modal analysis, which uses the most significant vibration modes of the object to compute the deformations in real-time for applied forces. The second method uses the spectral Lanczos decomposition to obtain the explicit solutions of the finite element equations.

medical↗