Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Low-Power CMOS Digital Autocorrelator Spectrometer

Prototype digital autocorrelator spectrometer circuit designed and built as assembly of few very-large-scale integrated (VLSI) complementary metal oxide/semiconductor (CMOS) circuit chips. Spectrometer contains 128 frequency channels and operates at clock rate of as much as 40 MHz. Total dc power needed is only 6 W. Digital autocorrelator spectrometer consists of four 32-channel autocorrelator chips that collectively produce 128-point spectrum of input signal as computed by use of Fourier transform.

Chandra, Kumar M.↗

The Los Alamos neutron spectrometer for the Lunar Scout-1 mission

We review the current status of the Los Alamos program to develop a neutron spectrometer for the Lunar Scout-1 mission, which is the first of two such missions to obtain global compositional, gravity, topography, and image maps of the lunar surface during nominal one-year missions. The neutron spectrometer will measure fast and slow (epithermal and thermal) neutrons in the ranges of 0.5 MeV to 25 MeV and 0.01 eV to more than 1 keV, respectively. The neutron spectrometer will consist of two independent instruments, a fast-neutron one, and a thermal and epithermal one. The measured neutron fluxes are very sensitive to hydrogen in the top meter of the lunar surface and provide additional information about lunar composition.

Auchampaugh, George↗

A comparison of LOWTRAN-7 corrected Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data with ground spectral measurements

Atmospheric correction of imaging spectroscopy data is required for quantitative analysis. Different models were proposed for atmospheric correction of these data. LOWTRAN-7 is a low-resolution model and computer code for predicting atmospheric transmittance and background radiance from 0 to 50,00 cm(sup -1) which was developed by the Air Force Geophysics Laboratory. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data used are radiometrically calibrated and include the 28 Sep. 1989 Providence Fan flight line segment 07, California. It includes a dark gravel surface defined as a calibration site by the Geologic Remote Sensing Field Experiment (GRSFE). Several ground measurements of portable spectrometer DAEDALUS AA440 Spectrafax were taken during the GRSFE, July 1989 field campaign. Comparisons of the LOWTRAN-7 corrected AVIRIS data with the ground spectrometer measurement were made.

Xu, Peng-Yang↗

Far-infrared heterodyne spectrometer

A far-infrared heterodyne spectrometer was designed and built by our group for observations of atomic and molecular lines from interstellar clouds. Linewidths as narrow as 1 km/s can be expected from such regions, and so the spectrometer is designed with sub-km/s resolution so that observed line profiles will be resolved. Since its debut on the Kuiper Airborne Observatory (KAO) in 1985, the instrument has been used in regular annual flight programs from both Moffett Field, CA and Christchurch, NZ. The basic plan of the spectrometer remains unchanged from the original design presented at the previous airborne science symposium. Numerous improvements and updates to the technical capability have of course been included over the many years of operational service.

Boreiko, Rita T.↗

Shuttle Upper Atmosphere Mass Spectrometer Experimental Flight Results

Calibrated pressure measurements for species with mass-to-charge ratios up to 50 amu/e(-) were obtained trom the shuttle upper atmosphere mass spectrometer experiment during re-entry on the STS-35 mission. The principal experimental objective is to obtain measurements of freestream density in the hypersonic rarefied flow flight regime. Data were collected from 180 to about 87 km. However, data above 115 km were contaminated from a source of gas emanating from pressure transdueers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data are compared to the mass spectrometer total pressure with excellent agreement. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions. The freestream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. Standard Atmosphere model, exhibits the wavelike nature seen on previous flights using accelerometry. Selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump.

Blanchard, R. C.↗

Performance of an INTEGRAL spectrometer model

Model calculations for the INTEGRAL spectrometer (SPI) onboard the future INTErnational Gamma Ray Astrophysics Laboratory (INTEGAL) are presented, where the sensitivity for narrow lines is based on estimates of the background level and the detection efficiency. The instrumental background rates are explained as the sum of various components that depend on the cosmic ray intensity and the spectrometer characteristics, such as the mass distribution around the Ge detectors, the passive material, the characteristics of the detector system and the background reduction techniques. Extended background calculations were performed with Monte Carlo simulations and using semi-empirical and calculated neutron and proton cross sections. In order to improve the INTEGRAL spectrometer sensitivity, several designs and background reduction techniques were compared for an instrument with a fixed detector volume.

Jean, P.↗

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

An Optics Free Spectrometer for the Extreme Ultraviolet

The optics-free spectrometer is a photon spectrometer. It provides the photon spectrum of a broadband source by converting photons of energy E into electrons of energy E', according to the Einstein relation, E' = E - Ei. E, is the ionization threshold of the gas target of interest (any of the rare gases are suitable) and E is the incoming photon energy. As is evident from the above equation, only a single order spectrum is produced throughout the energy range between the first and second ionization potentials of the rare gas used. Photons with energy above the second ionization potential produce two groups of electrons, but they are readily distinguished from each other. This feature makes this device extremely useful for determining the true spectrum of a continuum source or a many line source. The principle of operation and the laboratory results obtained with a representative configuration of the optics-free spectrometer are presented.

Judge, D. L.↗

Interchange for Joint Research Entitled: Miniature Laser Spectrometer for Stable Isotope Measurements

As a first step in successfully measuring carbon isotopes optically we have previously demonstrated the measurement of C-13/C-12 to a precision of 0.1% using a tunable diode laser and CO2 spectral lines in the 2300/cm spectral region. This precision of 0.1% (1 per mil) for carbon isotopes is a value sufficiently precise to provide important isotopic data of interest to astrobiologists. The precision presently attainable in gases is sufficient to permit our instrument to be used in the measurement of isotopic ratios of interest to astrobiologists as well as geologists and planetary scientists. A small stable isotope laser spectrometer with a 10 cm path gas cell was designed and constructed. The cell was integrated with a liquid nitrogen cooled tunable diode laser and indium antimonide detector for evaluation. Using the small gas cell, preliminary measurements of 13C/12C in CO2 were made employing single-beam sequential acquisitions of the required spectral data. The results indicate an accuracy of 0.1% which is sufficiently high to make meaningful measurements of martian samples. In addition, improvements in the spectrometer gas handling system have been made to markedly reduce C-13/C-12 isotopic fractionation during sample gas cell loading which we expect will lead to further improvements in precision and accuracy. An important part of making isotopic ratio measurements in solid samples using diode lasers is the conversion of the elements of interest to molecules that have absorption spectra in the mid-ir spectral range accessible by tunable diode lasers. In this project we have investigated the necessary sample preparation procedures to extract carbon, an element of astrobiological importance, from model soil compounds and to convert it to CO2, a molecule with appropriate optical absorption characteristics for reliable laser spectrometer isotopic ratio measurements of 13C/12C. We have considered calcium carbonate as a model for a component of the martian regolith, and we have formulated a simple heating protocol for extracting carbon in the form of CO2.

Becker, J. F.↗

Using the World Primary Standard Dobson Spectrometer to Monitor the Stability of a Multi-Instrument Satellite Ozone Dataset

NASA is creating a long term satellite ozone time series by combining data from multiple instruments: Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) (1978 - 1993), Meteor 3 TOMS (1991 - 1994), Earth Probe TOMS (1996 - present), Nimbus 7 SB-JV (1978 - 1990), NOAA-9 Solar Backscatter UV Spectrometer (SBUV/2) (1984 - 1997), NOAA-11 SBUV/2 (1989 - 1994), and NOAA-14 SBUV/2 (1995 - present). The stability of individual data sets and possible instrument-to-instrument differences are best checked by comparison with ground-based measurements. We have examined the time dependence of the calibrations of these instruments by comparing satellite derived ozone with that measured by the world primary standard Dobson spectrometer No. 83. This instrument has been maintained since 1962 as a standard for total ozone to an uncertainty of plus or minus 0.5%. Measurements of AD pair ozone made with instrument No. 83 at Mauna Loa observatory most summers since 1979 were compared with coincident TOMS and SBUV(/2) ozone measurements. The comparison shows that the various instruments were stable relative to instrument No. 83 to within about plus or minus 1%, but that there are instrument-to-instrument biases of as much as 3%. Earth Probe TOMS, for example, is 1% to 2% high relative to Nimbus 7 TOMS when the world standard instrument is used as a transfer standard. Similar results are seen when comparisons are made with an ensemble of 41 Dobson stations throughout the world, demonstrating that the ensemble as a whole is stable despite the fact that many instruments within the ensemble have clear calibration changes.

McPeters, R.D.↗

Spectral Anomalies in the 11 and 12 micron Region From the Mariner Mars 7 Infrared Spectrometer

Two hundred-forty infrared spectra acquired by the 1969 Mariner Mars 7 Infrared Spectrometer (IRS), spanning the wavelength region 1.8-14.4 micron (5550-690/cm), have recently been recovered and calibrated in both wavelength and intensity. An examination of these IRS spectra has revealed absorptions at 11.25 and 12.5 micron that have not previously been reported for Mars. A search of the literature and spectral data bases shows that materials that exhibit a doublet at 11.25 and 12.5 micron are rare. In this paper we examine potential causes for these features and include a detailed discussion of carbonates, goethite, CO2 ice, and water ice. CO2 ice and water ice measured in transmission do not exhibit bands that match those recorded at 11.25 and 12.5 micron for Mars, which indicates that CO2 or water ice clouds are not the source of these features. Since these bands show no clear correlation with atmospheric path length, they are most likely caused by a surface material. In the IRS database they appear to be exceptionally intense in the western part of the Hellas basin. Goethite exhibits bands that are a good spectral match, but confirming whether goethite causes the features will require additional studies of the 20-50 micron region. These studies will require laboratory measurements of weathering coatings and an examination of spectra recorded of Mars by the 1971 Mariner Mars Infrared Interferometer Spectrometer (IRIS; 5-50 micron 2000200/cm) and the 1996 Thermal Emission Spectrometer (TES; 6-50 micron 1667-200/cm).

Kirkland, Laurel E.↗

Development of a Submillimeter-Wavelength Immersion Grating Spectrometer

The broad goal of this project was to develop a broadband, moderate-resolution spectrometer for submillimeter wavelengths. Our original approach was to build an immersion grating spectrometer, and as such, the first step was to identify the best material (lowest loss, highest index) for the grating medium, and to characterize its properties at the foreseen optical-bench operating temperature of 1.5 K. To this end, we put our initial efforts into upgrading an existing laboratory submillimeter Fourier transform spectrometer, which allowed us to carry out the requisite materials measurements. The associated cryogenic detector dewar was also redesigned and rebuilt to carry out this work. This dewar houses the 1.5 K detector and the filter wheel used in the materials characterization. Our goal was to have the beam propagate through the samples as uniformly as possible, so the optics were redesigned to allow for the samples to be traversed by a well-defined collimated beam. The optics redesign also placed the samples at an image of the aperture stop located within the FTS. After the rebuild, we moved into the testing phase.

Phillips, T. G.↗

A Quadrupole Ion Trap Mass Spectrometer for Quantitative Analysis of Nitrogen-Purged Compartments within the Space Shuttle

To enter orbit, the Space Shuttle burns 1.8 million liters of liquid hydrogen combined with 0.8 million liters of liquid oxygen through three rocket engines mounted in the aft. NASA monitors the nitrogen-purged aft compartment for increased levels of hydrogen or oxygen in order to detect and determine the severity of a cryogenic fuel leak. Current monitoring is accomplished with a group of mass spectrometer systems located as much as 400 feet away from the Shuttle. It can take up to 45 seconds for gas to reach the mass spectrometer, which precludes monitoring for leaks in the final moments before liftoff (the orbiter engines are started at T-00:06 seconds). To remedy the situation, NASA is developing a small rugged mass spectrometer to be used as point-sensors around the Space Shuttle. As part of this project, numerous mass analyzer technologies are being investigated. Presented here are the preliminary results for one such technology, quadrupole ion trap mass spectrometry (QITMS). A compact QITMS system has been developed in-house at the University of Florida for monitoring trace levels of four primary gases, hydrogen, helium, oxygen, and argon, all in a nitrogen background. Since commercially available QITMS systems are incapable of mass analysis at m/z(exp 2), the home-built system is preferred for the evaluation of QITMS technology.

Ottens, Andrew K.↗

A Quadrupole Ion Trap Mass Spectrometer for Quantitative Analysis of Nitrogen-Purged Compartments within the Space Shuttle

To enter orbit the Space Shuttle burns 1.8 million liters of liquid hydrogen combined with 0.8 million liters of liquid oxygen through three rocket engines mounted in the aft. NASA monitors the nitrogen-purged aft compartment for increased levels of hydrogen or oxygen in order to detect and determine the severity of a cryogenic fuel leak. Current monitoring is accomplished with a group of mass spectrometer systems located as much as 400 feet away from the shuttle. It can take up to 45 seconds for gas to reach the mass spectrometer, which precludes monitoring for leaks in the final moments before liftoff (the orbiter engines are started at T-00:06 seconds). To remedy the situation, NASA is developing a small rugged mass spectrometer to be used as point-sources around the Space Shuttle.

Ottens, Andrew K.↗

Solar Imaging UV/EUV Spectrometers Using TVLS Gratings

It is a particular challenge to develop a stigmatic spectrograph for UV, EUV wavelengths since the very low normal-incidence reflectance of standard materials most often requires that the design be restricted to a single optical element which must simultaneously provide both reimaging and spectral dispersion. This problem has been solved in the past by the use of toroidal gratings with uniform line-spaced rulings (TULS). A number of solar extreme ultraviolet (EUV) spectrometers have been based on such designs, including SOHO/CDS, Solar-B/EIS, and the sounding rockets Solar Extreme ultraviolet Research Telescope and Spectrograph (SERTS) and Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS). More recently, Kita, Harada, and collaborators have developed the theory of spherical gratings with varied line-space rulings (SVLS) operated at unity magnification, which have been flown on several astronomical satellite missions. We now combine these ideas into a spectrometer concept that puts varied-line space rulings onto toroidal gratings. Such TVLS designs are found to provide excellent imaging even at very large spectrograph magnifications and beam-speeds, permitting extremely high-quality performance in remarkably compact instrument packages. Optical characteristics of three new solar spectrometers based on this concept are described: SUMI and RAISE, two sounding rocket payloads, and NEXUS, currently being proposed as a Small-Explorer (SMEX) mission.

Thomas, Roger J.↗

X-ray Spectrometer

The X-ray Spectrometer (XRS) instrument is a revolutionary non-dispersive spectrometer that will form the basis for the Astro-E2 observatory to be launched in 2005. We have recently installed a flight spare X R S microcalorimeter spectrometer at the EBIT-I facility at LLNL replacing the XRS from the earlier Astro-E mission and providing twice the resolution. The X R S microcalorimeter is an x-ray detector that senses the heat deposited by the incident photon. It achieves a high energy resolution by operating at 0.06K and by carefully controlling the heat capacity and thermal conductance. The XRS/EBIT instrument has 32 pixels in a square geometry and achieves an energy resolution of 6 eV at 6 keV, with a bandpass from 0.1 to 12 keV (or more at higher operating temperature). The instrument allows detailed studies of the x-ray line emission of laboratory plasmas. The XRS/EBIT also provides an extensive calibration "library" for the Astro-E2 observatory.

Porter, F. Scott↗

Analysis of a crossed Bragg cell acousto-optical spectrometer for SETI

The search for radio signals from extraterrestrial intelligent beings (SETI) requires the use of large instantaneous bandwidth (500 MHz) and high resolution (20 Hz) spectrometers. Digital systems with a high degree of modularity can be used to provide this capability, and this method has been widely discussed. Another technique for meeting the SETI requirement is to use a crossed Bragg cell spectrometer as described by Psaltis and Casasent. This technique makes use of the Folded Spectrum concept, introduced by Thomas. The Folded Spectrum is a 2-D Fourier Transform of a raster scanned 1-D signal. It is directly related to the long 1-D spectrum of the original signal and is ideally suited for optical signal processing. The folded spectrum technique has received little attention to date, primarily because early systems made use of photographic film which are unsuitable for the real time data analysis and voluminous data requirements of SETI. An analysis of the crossed Bragg cell spectrometer is presented as a method to achieve the spectral processing requirements for SETI. Systematic noise contributions unique to the Bragg cell system will be discussed.

NASA Discipline Number 52-60↗

Design, tolerancing and alignment of pushbroom imaging spectrometers for high response uniformity

We present a design and tolerancing approach that permits the achievement of a high degree of spatial and spectral uniformity of response from a pushbroom imaging spectrometer. Such uniformity of response is crucial for the extraction of accurate spectroscopic information from remotely sensed data. The spectrometer system example comprises two independent spectrometer modules covering the 400-2500 nm range, seperated through a dichroic mirror.

imaging spectrometry optical design tolerancing↗