Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Improved determination of the 𝛽−‾‾𝜈𝑒 angular correlation coefficient 𝑎 in free neutron decay with the 𝑎⁢SPECT spectrometer

We report on a precise measurement of the electron-antineutrino angular correlation (𝑎 coefficient) in free neutron beta decay from the 𝑎⁢SPECT experiment. The 𝑎 coefficient is inferred from the recoil energy spectrum of the protons which are detected in 4⁢𝜋 by the 𝑎⁢SPECT spectrometer using magnetic adiabatic collimation with an electrostatic filter. Data are presented from a 100-day run at the Institut Laue Langevin in 2013. The sources of systematic errors are considered and included in the final result. We obtain 𝑎=−0.10430⁢(84) which is the most precise measurement of the neutron 𝑎 coefficient to date. From this, the ratio of axial vector to vector coupling constants is derived giving |𝜆|=1.2677⁢(28).

Beck, Marcus↗

Measurement of deeply virtual Compton scattering off 4 He with the CEBAF Large Acceptance Spectrometer at Jefferson Lab

We report on the measurement of the beam spin asymmetry in the deeply virtual Compton scattering off $^4$He using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab using a 6 GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target. We detail the method used to ensure the exclusivity of the measured reactions, in particular the upgrade of CLAS with a radial time projection chamber to detect the low-energy recoiling $^4$He nuclei and an inner calorimeter to extend the photon detection acceptance at forward angles. Our results confirm the theoretically predicted enhancement of the coherent ($e^4$He$~\to~e'$$^4$He$'\gamma'$) beam spin asymmetries compared to those observed on the free proton, while the incoherent ($e^4$He$~\to~e'$p$'\gamma'$X$'$) asymmetries exhibit a 30$\%$ suppression. From the coherent data, we were able to extract, in a model-independent way, the real and imaginary parts of the only $^4$He Compton form factor, $\cal H_A$, leading the way toward 3D imaging of the partonic structure of nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lifetime measurements of states of S 35 , S 36 , S 37 , and S 38 using the AGATA γ -ray tracking spectrometer

Lifetimes or lifetime limits of a small number of excited states of the sulfur isotopes with mass numbers A = 35 , 36, 37, and 38 have been measured using the differential recoil-distance method. The isotopes of sulfur were populated in binary grazing reactions initiated by a beam of 36 S ions of energy 225 MeV incident on a thin 208 Pb target which was mounted in the Cologne plunger apparatus. The combination of the PRISMA magnetic spectrometer and an early implementation of the AGATA γ-ray tracking array was used to detect γ rays in coincidence with projectile-like nuclear species. Lifetime measurements of populated states were measured within the range from about 1 to 100 ps. The number of states for which lifetime measurements or lifetime limits were possible was limited by statistics. For 35 S, the lifetime was determined for the first 1/2 + state at 1572 keV; the result is compared with a previous published lifetime value. The lifetime of the 3 - state of 36 S at 4193 keV was determined and compared with earlier measurements. No previous lifetime information exists for the (6 + ) state at 6690 keV; a lifetime measurement with large associated error was made in the present work. For 37 S, the states for which lifetime limits were established were those at 646 keV with J π = 3/2 - and at 2776 keV with J π = 11/2 - ; there are no previously published lifetime values for excited states of 37 S. Finally, a lifetime limit was established for the J π =(6 + ) state of 38 S at 3675 keV; no lifetime information exists for this state in the literature. Measured lifetime values were compared with the results of state-of-the-art shell-model calculations based on the PSDPF, SDPF-U, and FSU effective interactions. In addition, nuclear magnetic-dipole and electric-quadrupole moments, branching ratios, mixing ratios, and electromagnetic transition rates, where available, have been compared with shell-model values. The current work suffers from poor statistics; nevertheless, lifetime values and limits have been possible, allowing a useful discussion of the ability of state-of-the-art shell-model calculations to reproduce the experimental results.

electromagnetic transitions↗

Decay studies of the 𝛽-delayed neutron emitters 87 Br and 88 Br measured by means of the Modular Total Absorption Spectrometer at ORNL HRIBF

The β decays of 87 Br, 88 Br, and 87 Kr were measured with the Modular Total Absorption Spectrometer (MTAS) at Oak Ridge National Laboratory’s Holifield Radioactive Ion Beam Facility (HRIBF). Both bromine isotopes are β-delayed neutron emitters that have large cumulative fission yields and were identified as top-priority cases for total absorption study by the Nuclear Energy Agency in 2007. Our investigations corroborate that the decay schemes of 87 Br and 88 Br suffer from the so-called pandemonium effect. Unique MTAS properties enable direct neutron measurements. Here, we present MTAS-derived β-delayed neutron spectra, β-delayed neutron emission probabilities of P n ( 87 Br) = 2.36(24)%, and P n ( 88 Br) = 6.4(6)%, and the β-delayed neutron transitions intensity of 4(2)% to the first excited 87 Kr state, populated in the β-neutron decay of 88Br. Incorporating new data into calculations of the electromagnetic decay heat component emitted during thermal neutron fission of 235 U and 239 Pu improves agreement with experimental data up to approximately 80 s after fission. The estimation of the nuclear reactor $\bar{ν}_e$ flux results in changes of up to 1% in the expected $\bar{ν}_e$ interactions with the detector material for 235 U, 238 U, 239Pu, and 241 Pu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Properties of Cosmic Deuterons Measured by the Alpha Magnetic Spectrometer

Precision measurements by the Alpha Magnetic Spectrometer (AMS) on the International Space Station of the deuteron (𝐷) flux are presented. The measurements are based on 21 × 10 6 𝐷 nuclei in the rigidity range from 1.9 to 21 GV collected from May 2011 to April 2021. We observe that over the entire rigidity range the 𝐷 flux exhibits nearly identical time variations with the 𝑝, 3 He, and 4 He fluxes. Above 4.5 GV, the 𝐷/ 4 He flux ratio is time independent and its rigidity dependence is well described by a single power law ∝𝑅 Δ with Δ 𝐷/ 4 He = −0.108 ± 0.005. This is in contrast with the 3 He/ 4 He flux ratio for which we find Δ 3 He/ 4 He = −0.289 ± 0.003. Above ∼13 GV we find a nearly identical rigidity dependence of the 𝐷 and 𝑝 fluxes with a 𝐷/𝑝 flux ratio of 0.027 ± 0.001. These unexpected observations indicate that cosmic deuterons have a sizable primarylike component. With a method independent of cosmic ray propagation, we obtain the primary component of the 𝐷 flux equal to 9.4 ± 0.5% of the 4 He flux and the secondary component of the 𝐷 flux equal to 58 ± 5% of the 3 He flux.

cosmic ray acceleration↗

Properties of Cosmic Lithium Isotopes Measured by the Alpha Magnetic Spectrometer

We present the first measurement of cosmic-ray fluxes of 6 Li and 7 Li isotopes in the rigidity range from 1.9 to 25 GV. The measurements are based on 9.7 × 10 5 6 Li and 1.04 × 10 6 7 Li nuclei collected by the Alpha Magnetic Spectrometer on the International Space Station from May 2011 to October 2023. We observe that over the entire rigidity range the 6 Li and 7 Li fluxes exhibit nearly identical time variations and, above ∼4 GV, the time variations of 6 Li , 7 Li , He, Be, B, C, N, and O fluxes are identical. Above ∼7 GV, we find an identical rigidity dependence of the 6 Li and 7 Li fluxes. This shows that they are both produced by collisions of heavier cosmic-ray nuclei with the interstellar medium and, in particular, excludes the existence of a sizable primary component in the 7 Li flux.

cosmic ray acceleration↗

High-energy-resolution inelastic X-ray scattering spectrometer at beamline 30-ID of the Advanced Photon Source

Inelastic X-ray scattering is a powerful and versatile technique for studying lattice dynamics in materials of scientific and technological importance. In this article, the design and capabilities of the momentum-resolved high-energy-resolution inelastic X-ray spectrometer (HERIX) at beamline 30-ID of the Advanced Photon Source are reported. The instrument operates at 23.724 keV and has an energy resolution of 1.3–1.7 meV. It can accommodate momentum transfers of up to 72 nm -1 , at a typical X-ray flux of 4.5 × 10 9 photons s -1 meV -1 at the sample. A suite of in situ sample environments are provided, including high pressure, static magnetic fields and uniaxial strains, all at high or cryogenic temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-shot hard X-ray spectrometer with uniform spatial and spectral response

We demonstrate a single-shot hard X-ray spectrometer based on small-angle scattering from glassy carbon that is insensitive to XFEL beam-dependent spatial and spectral variations. Comparison with established X-ray Thomson scattering diagnostics using stochastic correlation X-ray spectroscopy demonstrates full-bandwidth coverage with meV-scale spectral resolution, enabling reliable single-shot spectroscopic measurements.

47 OTHER INSTRUMENTATION↗

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION↗

Kinematics reconstruction in solenoidal spectrometers operated in active target mode

Here, we discuss the reconstruction of low-energy nuclear reaction kinematics from charged-particle tracks in solenoidal spectrometers working in Active Target Time Projection Chamber mode. In this operation mode, reaction products are tracked within the active gas medium of the Active Target with a three dimensional space point cloud. We have inferred the reaction kinematics from the point cloud using an algorithm based on a linear quadratic estimator (Kalman filter). The performance of this algorithm has been evaluated using experimental data from nuclear reactions measured with the Active Target Time Projection Chamber (AT-TPC) detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A search for new physics in central exclusive production using the missing mass technique with the CMS detector and the CMS-TOTEM precision proton spectrometer

A generic search is presented for the associated production of a Z boson or a photon with an additional unspecified massive particle X, pp → pp + Z/γ + X, in proton-tagged events from proton–proton collisions at $\sqrt{s}$ = 13 TeV, recorded in 2017 with the CMS detector and the CMS-TOTEM precision proton spectrometer. The missing mass spectrum is analysed in the 600–1600 GeV range and a fit is performed to search for possible deviations from the background expectation. No significant excess in data with respect to the background predictions has been observed. Model-independent upper limits on the visible pro duction cross section of pp → pp + Z/γ + X are set

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lock In Spectrometer v0.1

A method that uses a spectrometer to run a lock in amplifier process on multiple frequencies simultaneously.

Slaughter, Daniel↗

A Methodology for Estimating the Energy and Moisture Budget of the Convective Boundary Layer Using Continuous Ground-Based Infrared Spectrometer Observations

Abstract Land–atmosphere interactions play a critical role in both the atmospheric water and energy cycles. Changes in soil moisture and vegetation alter the partitioning of surface water and energy fluxes, influencing diurnal evolution of the planetary boundary layer (PBL). The mixing-diagram framework has proven useful in understanding the evolution of the heat and moisture budget within the convective boundary layer (CBL). We demonstrate that observations from the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains site provide all of the needed inputs needed for the mixing-diagram framework, allowing us to quantify the impact from the surface fluxes, advection, radiative heating, encroachment, and entrainment on the evolution of the CBL. Profiles of temperature and humidity retrieved from the ground-based infrared spectrometer [Atmospheric Emitted Radiance Interferometer (AERI)] are a critical component in this analysis. Large-eddy simulation results demonstrate that mean mixed-layer values derived are shown to be critical to close the energy and moisture budgets. A novel approach demonstrated here is the use of network of AERIs and Doppler lidars to quantify the advective fluxes of heat and moisture. The framework enables the estimation of the entrainment fluxes as a residual, providing a way to observe the entrainment fluxes without using multiple lidar systems. The high temporal resolution of the AERI observations enables the morning, midday, and afternoon evolution of the CBL to be quantified. This work provides a new way to use observations in this framework to evaluate weather and climate models. Significance Statement The energy and moisture budget of the planetary boundary layer (PBL) is influenced by multiple sources, and accurately representing this evolution in numerical models is critical for weather forecasts and climate predictions. The mixing-diagram approach, driven by profiling observations as illustrated here, provides a powerful way to quantify the contributions from each of these sources. In particular, the energy and moisture mixed into the PBL from above the PBL can be determined accurately from ground-based remote sensors using this approach.

54 ENVIRONMENTAL SCIENCES↗