Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization

Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the dbposition and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered Camelina and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relating Molecular Properties to the Persistence of Marine Dissolved Organic Matter with Liquid Chromatography–Ultrahigh-Resolution Mass Spectrometry

Marine dissolved organic matter (DOM) contains a complex mixture of small molecules that eludes rapid biological degradation. Spatial and temporal variations in the abundance of DOM reflect the existence of fractions that are removed from the ocean over different time scales, ranging from seconds to millennia. However, it remains unknown whether the intrinsic chemical properties of these organic components relate to their persistence. Here, we elucidate and compare the molecular compositions of distinct DOM fractions with different lability along a water column in the North Atlantic Gyre. Our analysis utilized ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry at 21 T coupled to liquid chromatography and a novel data pipeline developed in CoreMS that generates molecular formula assignments and metrics of isomeric complexity. Clustering analysis binned 14 857 distinct molecular components into groups that correspond to the depth distribution of semilabile, semirefractory, and refractory fractions of DOM. The more labile fractions were concentrated near the ocean surface and contained more aliphatic, hydrophobic, and reduced molecules than the refractory fraction, which occurred uniformly throughout the water column. These findings suggest that processes that selectively remove hydrophobic compounds, such as aggregation and particle sorption, contribute to variable removal rates of marine DOM.

54 ENVIRONMENTAL SCIENCES↗

High-Resolution Tandem Mass Spectrometry-Based Analysis of Model Lignin–Iron Complexes: Novel Pipeline and Complex Structures

Understanding the chemical nature of soil organic carbon (SOC) with great potential to bind iron (Fe) minerals is critical for predicting the stability of SOC. Organic ligands of Fe are among the top candidates for SOCs able to strongly sorb on Fe minerals, but most of them are still molecularly uncharacterized. To shed insights into the chemical nature of organic ligands in soil and their fate, this study developed a protocol for identifying organic ligands using ultrahigh-performance liquid chromatography-high-resolution tandem mass spectrometry (UHPLC-HRMS/MS) and metabolomic tools. The protocol was used for investigating the Fe complexes formed by model compounds of lignin-derived organic ligands, namely, caffeic acid (CA), p-coumaric acid (CMA), vanillin (VNL), and cinnamic acid (CNA). Isotopologue analysis of 54/56 Fe was used to screen out the potential UHPLC-HRMS (m/z) features for complexes formed between organic ligands and Fe, with multiple features captured for CA, CMA, VNL, and CNA when 35/37 Cl isotopologue analysis was used as supplementary evidence for the complexes with Cl. MS/MS spectra, fragment analysis, and structure prediction with SIRIUS were used to annotate the structures of mono/bidentate mono/biligand complexes. The analysis determined the structures of monodentate and bidentate complexes of FeL x Cl y (L: organic ligand, x = 1–4, y = 0–3) formed by model compounds. The protocol developed in this study can be used to identify unknown organic ligands occurring in complex environmental samples and shed light on the molecular-level processes governing the stability of the SOC.

54 ENVIRONMENTAL SCIENCES↗

Time of Flight Secondary Ion Mass Spectrometry for Characterization of Pt-Coated Porous Transport Layers in PEM Water Electrolyzers

Titanium-based porous transport layers (PTLs) and iridium-based catalyst layers (CLs) are two main components of proton exchange membrane water electrolyzers (PEMWEs). PTLs are typically coated with platinum to minimize interfacial losses and to support long-term operation. Optimizing coatings and the PTL-CL interface requires comprehensive characterization. This study establishes time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a valuable technique for PTL characterization, addressing capabilities and limitations related to PTL morphology. A methodology was developed that uses a Cs + sputter beam for dynamic depth profiling, with data collected in both positive-ion (MCs + ) and negative-ion modes to generate depth profiles, 2D ion maps, and 3D ion reconstructions. ToF-SIMS detected relative differences in platinum-layer thickness between samples; these trends were validated by cross-sectional scanning transmission electron microscope (STEM) measurements and flat-titanium substrate controls. Interfacial oxide layers are identified in both ion modes, with enhanced oxide sensitivity in negative mode. The technique’s high sensitivity enables detection of nanometer-scale coatings and trace impurities within the bulk PTL structure. These results provide a methodological framework for analyzing Pt-coated PTLs, with the potential to extend to other components in PEMWEs and other electrolyzer systems.

36 MATERIALS SCIENCE↗

Helium Ion Microscopy with Secondary Ion Mass Spectrometry for Nanoscale Chemical Imaging and Analysis of Polyolefins

To date, chemical imaging of polymers and polymer blends has been primarily accomplished using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to directly visualize the distribution of components in a complex material with spatial resolution ranging from 100 nm to 5 μm. However, in many cases, this resolution falls far short of visualizing interfaces directly. To overcome these limitations, recent work has focused on developing a SIMS detection system based on a helium ion microscope (HIM) enabling chemical imaging with a demonstrated ~14 nm spatial resolution. Here, we utilize HIM-SIMS for differentiation between the olefin-based polymers of polyethylene (PE) and polypropylene (PP). We illustrate both analyses for separating PE and PP using specific mass fragment ratios as well as demonstrate spatially resolved imaging of phase-separated domains within PE. Altogether, we demonstrate the abilities of HIM-SIMS as a multimodal chemical technique for imaging and quantification of polyolefin interfaces, which could be more broadly applied to the analysis of more complex polymeric systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolved Gas Analysis–Mass Spectrometry Exposes Polymer Network Structures

Polymer network structures in epoxy thermosets play an important role in the final thermoset material properties. However, analytical characterization of these network structures is difficult due to their amorphous nature. In this work, the application of evolved gas analysis–mass spectrometry (EGA-MS) to characterize the polymer network structures of bisphenol A (BPA)-based thermosets is demonstrated. Analytical characterization of the polymer network structures is accomplished by monitoring the Product-Specific Kinetics (PSK) of BPA monomer formation during thermal degradation investigations. We relate observed differences in the activation energy (E a ) of BPA monomer formation to the local packing environment around the BPA monomer units within the polymer network. Variations in the local environment related to the polymer networks manifest qualitatively as broadening in the thermal profile of the BPA monomer evolution and quantitatively as changes in the activation energy (E a ). Three BPA thermoset formulations were investigated; two amine-cured thermoset with 4,4′-diaminodiphenylmethane (DDM) or poly(propylene glycol) bis(2-amino-propyl ether) (PPG400) and a homopolymerized thermoset via curing with Epikure 3253 catalyst (3253). Results revealed that the 3253 thermoset contained two distinct packing densities in the polymer network, while DDM and PPG400 thermosets had uniform distributions of packing densities. Results from the DDM thermoset revealed a gradually decreasing E a , while the apparent E a of PPG400 was consistent over the entire degradation. Furthermore, these differences in E a were concluded to stem from the flexibility of the corresponding polymer networks and the ability of the network components to rearrange and occupy formed voids. Due to the minimal sample required for analysis (100–200 μg), this EGA-MS technique has great potential for postproduction evaluation of composite parts to identify changes in the polymer networks from use and aging, which could signal compromised performance.

Degradation↗

Characterization of Sequentially Extracted Soil Organic Matter by Electrospray Ionization and Atmospheric Pressure Photoionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Soil organic matter (SOM) is a complex mixture of small molecules and biopolymers that are active in various biogeochemical processes. However, the chemical diversity of biopolymer-derived SOM remains poorly explored. Identifying this diversity is important because global environmental changes may well alter SOM chemistry, as field experiments are beginning to show. Here, organic solvent-extractable (DcMe-SOM), base-hydrolyzable (KOH Hy -SOM), and CuO-oxidizable (CuO Ox -SOM) SOM fractions from a forest with a long-term nitrogen addition experiment were sequentially extracted and characterized by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled with negative-ion electrospray ionization (ESI) or atmospheric pressure photoionization (APPI). From DcMe-SOM to CuO Ox -SOM, the total number of assigned formulas, average O/C ratio, aromaticity, and unsaturation degree of SOM continuously increased, while the average m/z and H/C ratio decreased. Moreover, the dominant chemical category shifted from lipid-like components to phytochemical- and protein-like components. Complementary to ESI, APPI effectively facilitated detection of additional compounds with low polarity. With long-term nitrogen addition, the average m/z, unsaturation degree, aromaticity, and oxidation state of SOM increased, and more aromatic nitrogen-containing formulas were detected in CuOOx-SOM. Our study demonstrates that chronic nitrogen deposition in forests alters both the small molecules and biopolymers of SOM fundamentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Mass Spectrometry Multimodal Imaging via Tip-Enhanced Photothermal Desorption

Materials ranging from adhesives, pharmaceuticals, lubricants, and personal care products are traditionally studied using macroscopic characterization techniques. However, their functionality is in reality defined by details of chemical organization on often noncrystalline matter with characteristic length scales on the order of microns to nanometers. Additionally, these materials are traditionally difficult to analyze using standard vacuum-based approaches that provide nanoscale chemical characterization due to their volatile and beam-sensitive nature. Therefore, approaches that operate under ambient conditions need to be developed that allow probing of nanoscale chemical phenomena and correlated functionality. Here, we demonstrate a tool for probing and visualizing local chemical environments and correlating them to material structure and functionality using advanced multimodal chemical imaging on a combined atomic force microscopy (AFM) and mass spectrometry (MS) system using tip-enhanced photothermal desorption with atmospheric pressure chemical ionization (APCI). We demonstrate enhanced performance metrics of the technique for correlated imaging and point sampling and illustrate the applicability for the analysis of trace chemicals on a human hair, additives in adhesives on paper, and pharmaceuticals samples notoriously difficult to analyze in a vacuum environment. Overall, this approach of correlating local chemical environments to structure and functionality is key to advancing research in many fields ranging from biology, to medicine, to material science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution

Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

A Fast-Pass, Desorption Electrospray Ionization Mass Spectrometry Strategy for Untargeted Metabolic Phenotyping

Desorption electrospray ionization mass spectrometry imaging (DESI-MSI) provides direct analytical readouts of small molecules that can be used to characterize the metabolic phenotypes of genetically engineered bacteria. In an effort to accelerate the time frame associated with the screening of mutant libraries, we have developed a high-throughput DESI-MSI analytical workflow implementing a single raster line-scan strategy that facilitates the collection of location-resolved molecular information from engineered strains on a subminute time scale. Evaluation of this “Fast-Pass” DESI-MSI phenotyping workflow on analytical standards demonstrated the capability of acquiring full metabolic profiling information with a throughput of ~40 s per sample. This Fast-Pass strategy was implemented in the analysis of genetically edited Escherichia coli strains that have been engineered to produce various free-fatty acids (FFAs) for applications relevant to biofuels. Due to the untargeted nature of DESI-MSI, the investigation of these strains yielded molecular information for both global metabolites and targeted detection of accumulated bioproducts, allowing simultaneous readouts of strain-specific chemical profiles and comparative measurements of FFA production levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unimodal Imaging of Monovalent Metal-Chelator Complexes and Lipids by MALDI Imaging Mass Spectrometry

Careful regulation of monovalent metal ions (M + ) is necessary to maintain a functional cellular system. Of these ions, appropriate sodium (Na + ) and potassium (K + ) concentrations are particularly integral for electrochemical signaling, as well as the secondary transport of nutrients and waste. Dysregulation of M + homeostasis can disrupt these mechanisms, potentially influencing the metabolism of downstream biomolecules such as lipids. Thus, the relationship between M + abundances and related biomolecular distributions must be elucidated to better understand the physiology of healthy and disordered tissues. Traditional techniques for imaging biological metal distributions include SIMS, LA-ICP-MS, and XRF; however, these capabilities are limited to elemental analysis or the analysis of molecular fragments and must be paired with other modalities to visualize distributions of more complex biomolecules within the same or similar samples. Conversely, matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) is a powerful tool often used for mapping such biomolecular distributions, but current methods are unable to detect metals within tissue. This study illustrates a novel methodology that adds metal detection to the MALDI IMS repertoire through which the simultaneous detection of M + metals and lipids is achievable. Using a robotic sprayer for homogeneous application, on-tissue deposition of the chelator deferiprone (DEF) enables subsequent detection of the ionizable metal-chelator complex by MALDI without hindering lipid detection. Our work provides proof-of-concept data for the simultaneous detection of K + , Na + , and intact lipids using MALDI IMS.

59 BASIC BIOLOGICAL SCIENCES↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

MolDiscovery: learning mass spectrometry fragmentation of small molecules

Identification of small molecules is a critical task in various areas of life science. Recent advances in mass spectrometry have enabled the collection of tandem mass spectra of small molecules from hundreds of thousands of environments. To identify which molecules are present in a sample, one can search mass spectra collected from the sample against millions of molecular structures in small molecule databases. The existing approaches are based on chemistry domain knowledge, and they fail to explain many of the peaks in mass spectra of small molecules. Here, we present molDiscovery, a mass spectral database search method that improves both efficiency and accuracy of small molecule identification by learning a probabilistic model to match small molecules with their mass spectra. A search of over 8 million spectra from the Global Natural Product Social molecular networking infrastructure shows that molDiscovery correctly identify six times more unique small molecules than previous methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Auto-deconvolution and molecular networking of gas chromatography–mass spectrometry data

We engineered a machine learning approach, MSHub, to enable auto-deconvolution of gas chromatography–mass spectrometry (GC–MS) data. We then designed workflows to enable the community to store, process, share, annotate, compare and perform molecular networking of GC–MS data within the Global Natural Product Social (GNPS) Molecular Networking analysis platform. MSHub/GNPS performs auto-deconvolution of compound fragmentation patterns via unsupervised non-negative matrix factorization and quantifies the reproducibility of fragmentation patterns across samples.

47 OTHER INSTRUMENTATION↗

Simultaneous isotopic analysis of fission product Sr, Mo, and Ru in spent nuclear fuel particles by resonance ionization mass spectrometry

Abstract Fission product Sr, Mo, and Ru isotopes in six 10-μm particles of spent fuel from a pressurized water reactor were analyzed by resonance ionization mass spectrometry (RIMS) and evaluated for utility in nuclear material characterization. Previous measurements on these same samples showed widely varying U, Pu, and Am isotopic compositions owing to the samples’ differing irradiation environments within the reactor. This is also seen in Mo and Ru isotopes, which have the added complication of exsolution from the UO 2 fuel matrix. This variability is a hindrance to interpreting data from a collection of particles with incomplete provenance since it is not always possible to assign particles to the same batch of fuel based on isotopic analyses alone. In contrast, the measured 90 Sr/ 88 Sr ratios were indistinguishable across all samples. Strontium isotopic analysis can therefore be used to connect samples with otherwise disparate isotopic compositions, allowing them to be grouped appropriately for interpretation. Strontium isotopic analysis also provides a robust chronometer for determining the time since fuel irradiation. Because of the very high sensitivity of RIMS, only a small fraction of material in each of the 10 μm samples was consumed, leaving the vast majority still available for other analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗