Search NASA⌕ Search

SEARCH · Search NASA

Results for “Structural Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Low-rank factorization of electron integral tensors and its application in electronic structure theory

In this letter, we introduce the reverse Cuthill-McKee (RCM) algorithm, which is often used for the bandwidth reduction of sparse tensors, to transform the two-electron integral tensors to their block diagonal forms. By further applying the pivoted Cholesky decomposition (CD) on each of the diagonal blocks, we are able to represent the high-dimensional two-electron integral tensors in terms of permutation matrices and low-rank Cholesky vectors. This representation facilitates the low-rank factorization of the high-dimensional tensor contractions that are usually encountered in post-Hartree-Fock calculations. In this letter, we discuss the second-order Møller-Plesset (MP2) method and linear coupled- cluster model with doubles (L-CCD) as two simple examples to demonstrate the efficiency of the RCM-CD technique in representing two-electron integrals in a compact form.

electronic structure theory↗

PEGylation affects cytotoxicity and cell-compatibility of poly(ethylene imine) for lung application: Structure-function relationships

Poly(ethylene imine) (PEI) has widely been used as non-viral gene carrier due to its capability to form stable complexes by electrostatic interactions with nucleic acids. To reduce cytotoxicity of PEI, several studies have addressed modified PEIs such as block or graft copolymers containing cationic and hydrophilic non-ionic components. Copolymers of PEI and hydrophilic poly(ethylene glycol) (PEG) with various molecular weights and graft densities were shown to exhibit decreased cytotoxicity and potential for DNA and siRNA delivery. In this study, we evaluated the cytotoxicity and cell-compatibility of different PEGylated PEI polymers in two murine lung cell lines. We found that the degree of PEGylation correlated with both cytotoxicity and oxidative stress, but not with proinflammatory effects. AB type copolymers with long PEG blocks caused high membrane damage and significantly decreased the metabolic activity of lung cells. In addition, they significantly increased the release of two lipid mediators such as 8-isoprostanes (8-IP) and prostaglandin E{sub 2} (PGE{sub 2}) in a dose-dependent manner. In contrast, the cytokine profiles which indicated high levels of acute-phase cytokines such as TNF-alpha, IL-6, and G-CSF did not follow any clear structure-function relationship. In conclusion, we found that modification of PEI 25kDa with high degree of PEGylation and low PEG chain length reduced cytotoxic and oxidative stress response in lung cells, while the proinflammatory potential remained unaffected. A degree of substitution in the range of 10 to 30 and PEG-chain lengths up to 2000 Da seem to be beneficial and merit further investigations.

60 APPLIED LIFE SCIENCES↗

Auger Electrons as Probes for Composite Micro- and Nano- structured Materials: Application to Solid Electrolyte Interphases in Graphite and Silicon-Graphite Electrodes

In this study, Auger electron spectroscopy (AES) combined with ion sputtering profilometry, Xray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) have been used in a complementary fashion to examine chemical and microstructural changes in graphite (Gr) and silicon/graphite (Si/Gr) blends contained in the negative electrodes of lithium-ion cells. We demonstrate how AES can be used to characterize morphology of the solid-electrolyte interphase (SEI) deposits in such heterogeneous media, complementing well-established methods, such as XPS and SEM. In this way we demonstrate that the SEI does not consist of uniformly thick layers on the graphite and silicon; the thickness of the SEI layers in cycle-life aged electrodes follows an exponential distribution with a mean of ca. 13 nm for the graphite and ca. 20-25 nm for the silicon nanoparticles (with a crystalline core of 50-70 nm in diameter). Furthermore, a “sticky-sphere” model, in which Si nanoparticles are covered with a layer of polymer binder (that is replaced by the SEI during cycling) of variable thickness is introduced to account for the features observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomistic modeling and HAADF investigations of misfit and threading dislocations in GaSb/GaAs hetero-structures for applications in high electron mobility transistors

A detailed investigation on the misfit and threading dislocations at GaSb/GaAs interface has been carried out using molecular dynamics simulation and quantitative electron microscopy techniques. The sources and propagation of misfit dislocations have been elucidated. The nature and formation mechanisms of the misfit dislocations as well as the role of Sb on the stability of the Lomer configuration have been explained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment of Acoustic Sensor Application to Structural Health Monitoring of Reactor Components

The objectives of SHM of advanced fission reactors include the following: (1) Maintain safe, reliable, and efficient operation of structures, systems, and components in accordance with design intent; (3) Reduce cost; (4) Improve the comprehensive life management of structures, systems, and components; and (5) Extend the operational life of a power system through retirement for cause. Advanced reactor designs currently being considered are expected to operate at higher temperatures than light water-cooled reactors and to support missions beyond baseload electricity generation. Methods to monitor and detect for these mechanisms will require structural health monitoring (SHM) techniques, with ultrasonic methods an ideal candidate given their widespread use for NDE. This document summarized the state of technology for ultrasonic technologies, as part of an assessment of technology gaps and needed research. The great majority of sensor development to date addresses elevated temperatures and radiation tolerance, and more work is needed in both areas. Little data exists regarding corrosion effects of advanced coolants on sensor materials and couplants. Of high importance is the need for ARDs and regulatory bodies to engage and define what level of SHM is needed for autonomous or semi-autonomous control of reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Fast Parallel Algorithm for Selected Inversion of Structured Sparse Matrices with Application to 2D Electronic Structure Calculations

We present an efficient parallel algorithm and its implementation for computing the diagonal of $H^-1$ where $H$ is a 2D Kohn-Sham Hamiltonian discretized on a rectangular domain using a standard second order finite difference scheme. This type of calculation can be used to obtain an accurate approximation to the diagonal of a Fermi-Dirac function of $H$ through a recently developed pole-expansion technique \cite{LinLuYingE2009}. The diagonal elements are needed in electronic structure calculations for quantum mechanical systems \citeHohenbergKohn1964, KohnSham 1965,DreizlerGross1990. We show how elimination tree is used to organize the parallel computation and how synchronization overhead is reduced by passing data level by level along this tree using the technique of local buffers and relative indices. We analyze the performance of our implementation by examining its load balance and communication overhead. We show that our implementation exhibits an excellent weak scaling on a large-scale high performance distributed parallel machine. When compared with standard approach for evaluating the diagonal a Fermi-Dirac function of a Kohn-Sham Hamiltonian associated a 2D electron quantum dot, the new pole-expansion technique that uses our algorithm to compute the diagonal of $(H-z_i I)^-1$ for a small number of poles $z_i$ is much faster, especially when the quantum dot contains many electrons.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study of an experimental technique for application to structural dynamic problems

An experimental program was conducted to determine the feasibility of using subscale plastic models to determine the response of full-scale aerospace structural components to impulsive, pyrotechnic loadings. A monocoque cylinder was impulsively loaded around the circumference of one end, causing a compressive stress wave to propagate in the axial direction. The resulting structural responses of two configurations of the cylinder (with and without a cutout) were recorded by photoelasticity, strain gages, and accelerometers. A maximum dynamic stress concentration was photoelastically determined and the accelerations calculated from strain-gage data were in good agreement with those recorded by accelerometers. It is concluded that reliable, quantitative structural response data can be obtained by the experimental techniques described in this report.

Snell, R. F.↗