Scalable dark matter searches using integrated photonics

Dark matter (DM) with masses of order an electronvolt or below can have a nonzero coupling to electromagnetism while being compatible with cosmological observations. In these models, the ambient DM behaves as a new classical source in Maxwell’s equations, which can excite potentially detectable electromagnetic (EM) fields in the laboratory. We propose a new integrated-photonics–based approach to search for dark matter candidates in the 0.1–few eV mass range. This approach offers a wide range of wavelength-scale devices like resonators and wave guides that are readily fabricated in large quantities, enabling a scalable and novel search. In particular, we demonstrate that refractive index-modulated resonators, such as etched/grooved microrings, or patterned slabs, support EM modes with efficient coupling to DM. When excited by DM, these modes are read out by coupling the resonators to a wave guide that terminates on a micron-scale–sized single photon detector, such as a single pixel of a low-noise charge-coupled device or a superconducting nanowire. We then estimate the sensitivity of this experimental concept in the context of axionlike particle and dark photon models of DM, demonstrating that nanophotonic confinement and scalability can extend dark matter sensitivity into previously unexplored parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors

Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $\eta$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning microwave losses in superconducting resonators

Abstract The performance of superconducting resonators, particularly cavities for particle accelerators and micro cavities and thin film resonators for quantum computations and photon detectors, has been improved substantially by recent material treatments and technological advances. As a result, the niobium cavities have reached the quality factors Q ∼ 10 11 at 1–2 GHz and 1.5 K and the breakdown radio-frequency (rf) fields H close to the dc superheating field of the Meissner state. These advances raise the questions of whether the state-of-the-art cavities are close to the fundamental limits, what these limits actually are, and to what extent the Q and H limits can be pushed by the materials nano structuring and impurity management. These issues are also relevant for many applications using high-Q thin film resonators, including single-photon detectors and quantum circuits. This topical review outlines basic physical mechanisms of the rf nonlinear surface impedance controlled by quasiparticles, dielectric losses and trapped vortices, as well as the dynamic field limit of the Meissner state. Sections cover methods of engineering an optimum quasiparticle density of states and superfluid density to reduce rf losses and kinetic inductance by pairbreaking mechanisms related to magnetic impurities, rf currents, and proximity-coupled metallic layers at the surface. A section focuses on mechanisms of residual surface resistance, which dominates rf losses at ultra low temperatures. Microwave losses of trapped vortices and their reduction by optimizing the concentration of impurities and pinning potential are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Revealing the loss mechanisms of a 3D superconducting microwave cavity for use in a dark matter search

Superconducting microwave cavities have found applications in many areas including quantum computing, particle accelerators, and dark matter searches. Their extremely high quality factors translate to very narrow bandwidth, which makes them key components of sensitive detectors. In this study, we aim to understand the loss mechanisms of an aluminium cavity, with a fundamental mode frequency of about 2.5123 GHz, and how they change as the cavity material transitions from the superconducting to normal state. We found that at temperatures not much lower than the transition temperature $T_c$, losses are dominated by quasiparticle excitations and are well described by the Bardeen–Cooper–Schrieffer theory. The exponential decrease of the quasiparticle density below $T_c$ results in a 1000-fold increase of the quality factor, as well as a shift of the resonance frequency due to the change of the kinetic inductance of the superconductor. At very low temperatures, losses due to two-level systems begin to dominate giving a peak in the quality factor of about 2.76 x 10 7 at 130 mK. Understanding the loss mechanisms is invaluable, as the working temperature of the cavity may vary during operation regardless of its application.

Physics - Physics of elementary particles and fiel↗

Involving the new generations in Fermilab endeavors

Since 1984 the Italian groups of the Istituto Nazionale di Fisica Nucleare (INFN) and Italian Universities, collaborating with the DOE laboratory of Fermilab (US) have been running a two-month summer training program for Italian university students. While in the first year the program involved only four physics students of the University of Pisa, in the following years it was extended to engineering students. This extension was very successful and the engineering students have been since then extremely well accepted by the Fermilab Technical, Accelerator, and Scientific Computing Division groups. Over the many years of its existence, this program has proven to be the most effective way to engage new students in Fermilab endeavors. Many students have extended their collaboration with Fermilab with their Master’s Thesis and PhD. Since 2004 the program has been supported in part by DOE in the frame of an exchange agreement with INFN. Over its almost 40 years of history, the program has grown in scope and size and has involved more than 550 Italian students from more than 20 Italian Universities, Several Institutes of Research, including ASI and INAF in Italy, and the ISSNAF Foundation in the US, have provided additional financial support. Since the program does not exclude appropriately selected non-Italian students, a handful of students from European and non-European Universities were also accepted over the years. Each intern is supervised by a Fermilab Mentor responsible for performing the training program. Training programs spanned from Tevatron, CMS, Muon (g-2), Mu2e, and Short Baseline Neutrino Experiments and DUNE design and experimental data analysis, development of particle detectors (silicon trackers, calorimeters, drift chambers, neutrino and dark matter detectors), design of electronic and accelerator components, development of infrastructures and software for exascale data handling, research on superconductive elements and on accelerating cavities, and theory of particle accelerators. Since 2010, within an extended program supported by the Italian Space Agency and the Italian National Institute of Astrophysics, a total of 30 students in physics, astrophysics, and engineering have been hosted for two months in the summer at US space science Research Institutes and laboratories. In 2015 the University of Pisa included these programs within its educational programs. Accordingly, Summer School students are enrolled at the University of Pisa for the duration of the internship and are identified and ensured as such. At the end of the internship, the students are required to write summary reports on their achievements. After positive evaluation by a University Examining Board, interns are acknowledged credits for their Diploma Supplement. The program was canceled in 2020 and 2021 due to the pandemic but restarted successfully in 2022. We believe this program can be taken as a model and easily adopted by interested institutions.

99 GENERAL AND MISCELLANEOUS↗

High resolution diagnostic tools for superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 –10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two high-resolution diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system, which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. This setup has a spatial resolution of ~ 13 μm in the azimuthal direction and ~ 1 cm along the cavity contour. The second setup is a stationary, combined magnetic and temperature mapping system, which uses anisotropic magnetoresistance sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. This system has a spatial resolution of 5 mm close to the iris and 11 mm at the equator. Initial results show a non-uniform distribution of trapped flux on the cavities’ surfaces, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The MU2E Experiment at FERMILAB: R&D, Design and Status

The Mu2e Experiment at Fermilab 1) will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus, µ - + N (A, Z) → e - + N (A, Z). This is an example of Charged Lepton Flavour Violation (CLFV) never observed experimentally. The dynamics of such a process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass (~104.967 MeV). If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between conversion and capture rate R µe ≤ 6 × 10 -17 (@ 90% C.L.). This will improve the current limit of a factor of 10 4 over previous experiments. The experiment complements and extends the current/planned searches (µ → eγdecay at MEG , mu3e) as well as the direct searches for new physics at the LHC. Indeed, such CLFV searches in the muon sector probe new physics at a mass scale inaccessible with direct searches at either present or planned high-energy colliders. To detect the muon conversion process, a very intense pulsed beam of negative muons is produced by means of a S-shape Superconducting Solenoid Magnet System that is organized into three subsystems: the Production Solenoid, the Transport Solenoid and the Detector Solenoid. The beam is stopped at 10 GHz on an Aluminum target inside the Detector Solenoid. The Mu2e detectors, also installed inside the Detector Solenoid, are a high-precision tracker made on ~20000 straw tubes, and a calorimeter composed of ~1500 pure CsI crystals organized in two disks and readout by two large area UV-extended Silicon Photomultipliers (SiPMs). The Detector Solenoid region is surrounded by a Cosmic Ray Veto based on scintillators readout by SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Simulation and Design of an On-Chip Superconducting Millimetre Filter-Bank Spectrometer

Abstract Superconducting on-chip filter banks provide a scalable, space saving solution to create imaging spectrometers at millimetre and submillimetre wavelengths. We present an easy to realise, lithographed superconducting filter design with a high tolerance to fabrication error. Using a capacitively coupled $$\lambda /2$$ λ / 2 microstrip resonator to define a narrow ( $$\lambda /\Delta \lambda = 300$$ λ / Δ λ = 300 ) spectral pass band, the filtered output of a given spectrometer channel directly connects to a lumped-element kinetic inductance detector. We show the tolerance analysis of our design, demonstrating $$<11\%$$ < 11 % change in filter quality factor to any one realistic fabrication error and a full filter-bank efficiency forecast to be 50% after accounting for fabrication errors and dielectric loss tangent.

Robson, G. (ORCID:0000000315279326)↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting low-energy interactions and the effects of energy accumulation in materials

Elusive as dark matter particles are, they are not the only entities that can produce small energy releases deep inside the most sensitive detectors. Cosmogenic and residual radioactivity as well as other factors can produce and slowly accumulate long-living excitations and defect configurations in materials. Unsteady and avalanche-like releases of accumulated energy can limit the dynamic range of detectors and the sensitivity of experiments. This type of mechanism, while not widely discussed in the dark matter and neutrino detectors community, got a lot of attention in discussions about systems with energy flow in the context of nonequilibrium thermodynamic. Here this paper explores the avalanche hypothesis using published data on low-energy background in detectors and available condensed-matter physics information on excitations, defects, and energetic molecules which can be produced in detector materials and examine ways to use these models to understand the origin of low-energy background in dark matter and other detectors and for suppression of these backgrounds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

General Failure Modes and Effects Analysis for Accelerator and Detector Magnet Design at JLab

The aim of this article is to develop a risk management procedure, which could be applied to the magnet design process, for both superconducting and normal magnets at the Jefferson Laboratory (JLab). This procedure allowed us to identify the key risks at each of the critical phases of design and propose procedures, tests, and checks to mitigate each risk. In this article, we present a qualitative and quantitative risk management procedure commonly referred to a “failure modes and effects analysis.” As part of this procedure, we calculated a risk priority number (RPN) for each activity of the process, identified the most critical activities and proposed mitigation activities, which in turn resulted in a revised RPN. Additionally, another benefit of this procedure was the identification of appropriate “control and hold” points within the design process, which allowed one to review and approve a particular outcome before proceeding to the next sequential activity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oxide-nitride heteroepitaxy for low-loss dielectrics in superconducting quantum circuits

Superconducting qubits show great promise for the realization of fault-tolerant quantum computing, but lossy, amorphous dielectrics limit current technology. Identifying highly crystalline and stoichiometric dielectrics with intrinsically low microwave loss is therefore a central materials challenge, yet experimentally validated platforms remain scarce. In this work, we integrate a crystalline dielectric into a heteroepitaxial TiN/$γ$-Al$_2$O$_3$/TiN trilayer grown via pulsed laser deposition. Correlative high-resolution imaging, diffraction, and spectroscopy measurements confirm the single-crystal quality and chemical integrity of all layers, with minimal defects and limited anion interdiffusion across the oxide-nitride interfaces. Using microwave lumped-element resonators with parallel-plate capacitors, we report the first direct measurement of the dielectric loss of epitaxial $γ$-Al$_2$O$_3$, for which we find a low intrinsic two-level system loss, $δ_{\text{TLS}}^0 = (2.8 \pm 0.1) \times 10^{-5}$. These results establish heteroepitaxial oxides on transition metal nitrides as an attractive materials platform for superconducting quantum circuits, particularly for integration into compact device architectures such as merged-element transmons and microwave kinetic inductance detectors.

Garcia-Wetten, David A. [Northwestern U.]↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Splitting phonons: Building a platform for linear mechanical quantum computing

Linear optical quantum computing provides a desirable approach to quantum computing, with only a short list of required computational elements. The similarity between photons and phonons points to the interesting potential for linear mechanical quantum computing using phonons in place of photons. Although single-phonon sources and detectors have been demonstrated, a phononic beam splitter element remains an outstanding requirement. Here we demonstrate such an element, using two superconducting qubits to fully characterize a beam splitter with single phonons. We further use the beam splitter to demonstrate two-phonon interference, a requirement for two-qubit gates in linear computing. In conclusion, this advances a new solid-state system for implementing linear quantum computing, further providing straightforward conversion between itinerant phonons and superconducting qubits.

97 MATHEMATICS AND COMPUTING↗

Critical thermonuclear reactions in classical novae and type I X-ray bursts

The goal of this project was to experimentally constrain the nuclear reaction rates whose uncertainties have the largest impact on models of classical novae and Type-I X-ray bursts. These astrophysical events occur when a white dwarf or neutron star, respectively, accretes hydrogen and helium from a companion star until a thermonuclear runaway ensues. The primary reactions of interest to this project for novae and X-ray bursts are 30 P(ρ,γ) 31 S and 15 O(α,γ) 19 Ne. The project methodology was to develop a new radiation detection system in two phases to measure the low-energy beta-delayed particle emissions of 31 Cl and 20 Mg at the National Superconducting Cyclotron Laboratory (NSCL) in order to constrain these two reaction rates. In particular, a gas-filled charged-particle detector was to be designed, constructed and operated, in concert with the SeGA array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Utilizing the Quantum Zeno Effect in superconducting qubit based particle sensors

Superconducting qubit sensors are a compelling option for detecting faint signals from dark matter or low energy neutrino interactions. Improving their reach calls for both signal amplification and background suppression. The Quantum Zeno Effect (QZE)--which governs how entanglement reshapes a quantum system's time evolution--addresses both needs. By quantifying these modified time dynamics, we can better predict a qubit's response to a genuine particle event while suppressing coherence dips from other local disturbances. We present a new QZE-based protocol that could mitigate a dominant source of coherence fluctuations from Two Level Systems, show initial measurements of the QZE in superconducting qubits, and discuss additional opportunities where understanding and exploiting the effect are critical for building robust, high-sensitivity qubit detectors.

Seidel, Olivia [Fermilab]↗

The Italian Summer Students Program at Fermilab and other US Laboratories: 40 years of education in particle physics and technology

Since 1983 the Italian groups collaborating with Fermilab (US) have been running a 2-month summer training program for Master students. While in the first year the program involved only 4 physics students, in the following years it was extended to engineering students. Many students have extended their collaboration with Fermilab with their Master Thesis and PhD. The program has involved more than 600 Italian students from more than 20 Italian universities. Each intern is supervised by a Fermilab Mentor responsible for the training program. Training programs spanned from Tevatron, CMS, Muon (g-2), Mu2e and SBN (MicroBooNE, Icarus, and SBND) and DUNE design and data analysis, development of particle detectors, design of electronic and accelerator components, development of infrastructures and software for tera-data handling, quantum computing and research on superconductive elements and accelerating cavities. In 2015 the University of Pisa included the program within its own educational programs. Summer Students are enrolled at the University of Pisa for the duration of the internship and at the end of the internship they write summary reports on their achievements. After positive evaluation by a University of Pisa Examining Board, interns are acknowledged 6 ECTS credits for their Diploma Supplement. The program was paused in 2020 and 2021 due to the COVID-19 pandemic, but it resumed in 2022. From 2022 to 2024, a total of 60 students participated in the nine-week training at Fermilab. We are currently organizing the 2025 program. This paper provides an overview of the program, which can serve as a model for other interested laboratories.