Surface characterization of Nb samples electropolished together with real superconducting rf accelerator cavities

Here, we report the results of surface characterizations of niobium (Nb) samples electropolished together with a single cell superconducting radio-frequency accelerator cavity. These witness samples were located in three regions of the cavity, namely at the equator, the iris and the beam-pipe. Auger electron spectroscopy (AES) was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive X-ray for elemental analysis (SEM/EDX) was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulfur (S) were found covering the samples non-uniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulfur.

43 PARTICLE ACCELERATORS↗

Is light-induced degradation of a-Si:H/c-Si interfaces reversible?

Thin hydrogenated amorphous silicon (a-Si:H) films deposited on crystalline silicon (c-Si) surfaces are sensitive probes for the bulk electronic properties of a-Si:H. Here, we use such samples during repeated low-temperature annealing and visible-light soaking to investigate the long-term stability of a-Si:H films. We observe that during annealing the electronic improvement of the interfaces follows stretched exponentials as long as hydrogen evolution in the films can be detected. Once such evolution is no longer observed, the electronic improvement occurs much faster. Based on these findings, we discuss how the reversibility of light-induced defects depends on (the lack of observable) hydrogen evolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FAINT TIDAL FEATURES IN GALAXIES WITHIN THE CANADA-FRANCE-HAWAII TELESCOPE LEGACY SURVEY WIDE FIELDS

We present an analysis of the detectability of faint tidal features in galaxies from the wide-field component of the Canada-France-Hawaii Telescope Legacy Survey. Our sample consists of 1781 luminous (M{sub r{sup '}}<-19.3 mag) galaxies in the magnitude range 15.5 mag < r' < 17 mag and in the redshift range 0.04 < z < 0.2. Although we have classified tidal features according to their morphology (e.g., streams, shells, and tails), we do not attempt to interpret them in terms of their physical origin (e.g., major versus minor merger debris). Instead, we provide a catalog that is intended to provide raw material for future investigations which will probe the nature of low surface brightness substructure around galaxies. We find that around 12% of the galaxies in our sample show clear tidal features at the highest confidence level. This fraction rises to about 18% if we include systems with convincing, albeit weaker tidal features, and to 26% if we include systems with more marginal features that may or may not be tidal in origin. These proportions are a strong function of rest-frame color and of stellar mass. Linear features, shells, and fans are much more likely to occur in massive galaxies with stellar masses >10{sup 10.5} M {sub Sun }, and red galaxies are twice as likely to show tidal features than are blue galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Scanning photoelectron microscopy using a pointed capillary probe

The possibilities of a new type of scanning probe microscopy (SPM) for two different samples are experimentally demonstrated. The method is based on the use of a pointed capillary, which can simultaneously act as a ‘classical’ SPM probe and also as a controlled thin channel for transporting charged particles emitted by the surface to the detector. In the experiment, photoelectrons pass through a dielectric hollow cone probe with an aperture radius of 1 μm and detected by microchannel plates at different points of the investigated conducting surface irradiated by the second harmonic of a femtosecond Ti : sapphire laser. As a result, the sample’s surface profile is visualised with a subwavelength spatial resolution. This method makes it possible to control spatially localised beams of electrons, ions, neutral atoms (molecules) and soft X-ray radiation, as well as opens a possibility for research in the field of nanoscale photodesorption of molecular ions. (electron microscopy)

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of Vacuum on Force Response of an Ultrasonic Penetrator

Introduction: The Apollo astronauts encountered higher than expected resistances when interacting with the lunar soil via the Apollo Lunar Surface Drill (ALSD) and the trenching tool. Reducing the force required to move tools or other mechanical components through regolith will impact many steps of the resource extraction process. Force reduction has been achieved in soil materials by imparting vibration to tooling interfaces such as a vibratory farming cultivator, a percussive scoop, and ultrasonically resonant penetrators. Vibration-assisted tools in granular media reduce interaction forces by fluidizing a volume around the tool, allowing the tool to progress through a dynamic (fluid) medium instead of a static (solid) medium. This work seeks to quantify ultrasonic vibration’s effect on the force response of a penetrator in lunar soil simulant in vacuum sufficient to be within the molecular flow regime of any disturbed gases. Methods: A custom vacuum chamber setup, CUBEvac, was designed and built to facilitate penetration testing in a high vacuum environment, for comparison to penetration behavior in ambient terrestrial environment. A two-stage pumping system (Agilent Triscroll 600 roughing pump, Agilent VHS-6 oil diffusion pump) reached chamber pressures of about 5x10-6 Torr with regolith simulant in place. Figure 1 is a schematic of the heart of the assembly (note the penetration drive mechanisms above the chamber feedthrough and the regolith simulant sample in the bottom are not shown). The penetration actuation stack was comprised of a stepper motor driving a lead screw to move the ultra-sonic probe vertically inside the chamber. Motion was coordinated with an Arduino Uno. GRC-3 lunar simulant was used for this set of experiments. Samples were prepared in a four-liter stain-less steel, cylindrical pot with an internal diameter of approximately 15.56 cm (6.125 in) and a depth of 19.37 cm (7 5/8 in) for testing. The soil was baked out prior to compaction preparation as a measure to reduce soil moisture which interfered with pump down capacity. The soil was not baked again if it was removed from the vacuum chamber, prepped, and immediately returned to the vacuum chamber for pump down. The soil was compacted using a 60 Hz vibration table with a surcharge of 34 kg place on top of the soil in the container. Prepared soil samples weighed approximately 6.5 kg (bulk density 1.895-1.934 g/cm3). Two probe end effectors were tested: A cone penetrometer (static only) with a nominal diameter of 12.7 mm (0.5 in) and a nominal height of 28.6 mm (1.125 in); and a vibrating cylindrical probe measuring 12.7 mm in diameter and 50.8 mm in effective length from the tip (Figure 2). The cylindrical probe vibrated resonantly at 20 kHz with an amplitude 23 μm. The cone penetration tests were conducted to assess potential soil behavior differences in vacuum. The cylinder probe tests were conducted as the primary subject of this investigation to assess force response in vacuum. For each test, a regolith simulant sample was load-ed and compacted in the chamber, which was then evacuated for roughly 18 hours to reach the lowest possible pressure (approximately 5x10-6 Torr for most tests). The probe was then moved to about 10 mm above the soil surface before being pushed to a depth of 50 mm for the cylinder probe tests and to a depth of 100 mm for the cone penetrometer tests, both at a speed of 2 mm/s. The simulant samples were prepared the same for all tests. Ideally, they would respond consistently to probe penetration under ambient and vacuum conditions. This was evaluated by measuring the resistance of representative prepared simulant beds with a standard cone penetrometer in both environments. Results and Discussion: The resistance of the simulant samples in the vacuum tests was consistently lower than in the ambient tests as determined by the cone penetration tests. Thus, the ambient and vacuum results cannot be compared directly; work is underway to de-confound and better correlate the data. Still, figures 3-6 show that probe penetration forces are lower overall in the vacuum environment. In both environments, resonant vibration of the probe provides two useful effects: It reduces the probe penetration force and smooths the force-depth curve, significantly reducing local maxima. These effects have implications for various potential applications, such as astronaut hand-tools, where benefits (reducing astronaut effort) outweigh the cost of the additional energy re-quired to generate vibration. These results demonstrate that resonantly vibrating tools can meaningfully reduce the penetration force required for excavation, probing, and drilling tools in simulated lunar regolith deposits under vacuum levels approaching those that will be experience on the Moon’s surface. Lunar-gravity, ambient environment tests are scheduled soon. The effects of realistic temperatures and temperature gradients and deeper vacuum remain to be tested.

E Rezich↗

An ultra-compact, high-throughput molecular beam epitaxy growth system

We present a miniaturized molecular beam epitaxy (miniMBE) system with an outer diameter of 206 mm, optimized for flexible and high-throughput operation. The three-chamber system, used here for oxide growth, consists of a sample loading chamber, a storage chamber, and a growth chamber. The growth chamber is equipped with eight identical effusion cell ports with linear shutters, one larger port for either a multi-pocket electron beam evaporator or an oxygen plasma source, an integrated cryoshroud, retractable beam-flux monitor or quartz-crystal microbalance, reflection high energy electron diffraction, substrate manipulator, main shutter, and quadrupole mass spectrometer. The system can be combined with ultrahigh vacuum (UHV) end stations on synchrotron and neutron beamlines, or equivalently with other complex surface analysis systems, including low-temperature scanning probe microscopy systems. Substrate handling is compatible with most UHV surface characterization systems, as the miniMBE can accommodate standard surface science sample holders. We introduce the design of the system, and its specific capabilities and operational parameters, and we demonstrate the epitaxial thin film growth of magnetoelectric Cr{sub 2}O{sub 3} on c-plane sapphire and ferrimagnetic Fe{sub 3}O{sub 4} on MgO (001)

36 MATERIALS SCIENCE↗

The Lewis Research Center geomagnetic substorm simulation facility

A simulation facility was established at the NASA-Lewis Research Center to determine the response of typical spacecraft materials to the geomagnetic substorm environment and to evaluate instrumentation that will be used to monitor spacecraft system response to this environment. Space environment conditions simulated included the thermal-vacuum conditions of space, solar simulation, geomagnetic substorm electron fluxes and energies, and the low energy plasma environment. Measurements for spacecraft material tests included sample currents, sample surface potentials, and the cumulative number of discharges. Discharge transients were measured by means of current probes and oscilloscopes and were verified by a photomultiplier.

Berkopec, F. D.↗

The Lewis Research Center geomagnetic substorm simulation facility

A simulation facility was established to determine the response of typical spacecraft materials to the geomagnetic substorm environment and to evaluate instrumentation that will be used to monitor spacecraft system response to this environment. Space environment conditions simulated include the thermal-vacuum conditions of space, solar simulation, geomagnetic substorm electron fluxes and energies, and the low energy plasma environment. Measurements for spacecraft material tests include sample currents, sample surface potentials, and the cumulative number of discharges. Discharge transients are measured by means of current probes and oscilloscopes and are verified by a photomultiplier. Details of this facility and typical operating procedures are presented.

Berkopec, F. D.↗

Mathematical models of continuous flow electrophoresis: Electrophoresis technology

Two aspects of continuous flow electrophoresis were studied: (1) the structure of the flow field in continuous flow devices; and (2) the electrokinetic properties of suspended particles relevant to electrophoretic separations. Mathematical models were developed to describe flow structure and stability, with particular emphasis on effects due to buoyancy. To describe the fractionation of an arbitrary particulate sample by continuous flow electrophoresis, a general mathematical model was constructed. In this model, chamber dimensions, field strength, buffer composition, and other design variables can be altered at will to study their effects on resolution and throughput. All these mathematical models were implemented on a digital computer and the codes are available for general use. Experimental and theoretical work with particulate samples probed how particle mobility is related to buffer composition. It was found that ions on the surface of small particles are mobile, contrary to the widely accepted view. This influences particle mobility and suspension conductivity. A novel technique was used to measure the mobility of particles in concentrated suspensions.

Saville, Dudley A.↗

Time-domain imaging of gigahertz surface waves on an acoustic metamaterial

We extend time-domain imaging in acoustic metamaterials to gigahertz frequencies. Using a sample consisting of a regular array of ~1 μm diameter silica microspheres forming a two-dimensional triangular lattice on a substrate, we implement an ultrafast technique to probe surface acoustic wave propagation inside the metamaterial area and incident on the metamaterial from a region containing no microspheres, which reveals the acoustic metamaterial dispersion, the presence of band gaps and the acoustic transmission properties of the interface. Here, a theoretical model of this locally resonant metamaterial based on normal and shear-rotational resonances of the spheres fits the data well. Using this model, we show analytically how the sphere elastic coupling parameters influence the gap widths.

42 ENGINEERING↗

Fabrication of anti-adhesion surfaces on aluminium substrates of rubber plastic moulds using electrolysis plasma treatment

An anti-adhesion surface with a water contact angle of 167° was fabricated on aluminium samples of rubber plastic moulds by electrolysis plasma treatment using mixed electrolytes of C{sub 6}H{sub 5}O{sub 7}(NH{sub 4}){sub 3} and Na{sub 2}SO{sub 4}, followed by fluorination. To optimise the fabrication conditions, several important processing parameters such as the discharge voltage, discharge time, concentrations of supporting electrolyte and stearic acid ethanol solution were examined systematically. Using scanning electron microscopy (SEM) to analyse surfaces morphology, micrometer scale pits, and protrusions were found on the surface, with numerous nanometer mastoids contained in the protrusions. These binary micro/nano-scale structures, which are similar to the micro-structures of soil-burrowing animals, play a critical role in achieving low adhesion properties. Otherwise, the anti-adhesion behaviours of the resulting samples were analysed by the atomic force microscope (AFM), Fourier-transform infrared spectrophotometer (FTIR), electrons probe micro-analyzer (EPMA), optical contact angle meter, digital Vickers microhardness (Hv) tester, and electronic universal testing. The results show that the electrolysis plasma treatment does not require complex processing parameters, using a simple device, and is an environment-friendly and effective method. Under the optimised conditions, the contact angle (CA) for the modified anti-adhesion surface is up to 167°, the sliding angle (SA) is less than 2°, roughness of the sample surface is only 0.409μm. Moreover, the adhesion force and H{sub v} are 0. 9KN and 385, respectively.

36 MATERIALS SCIENCE↗

Nondestructive characterization of polycrystalline 3D microstructure with time-domain Brillouin scattering

In this paper, we employ gigahertz frequency ultrasonic waves to non-invasively image grain microstructure in polycrystalline ceria, an important electrolyte material for solid oxide fuel cells. This technique, termed time domain Brillouin scattering (TDBS), is a pump-probe technique that launches and monitors ultrasonics waves as they propagate from the surface into the depth of a sample. We demonstrate the capability of TDBS to image surface and subsurface grain structure by measuring mode and depth dependent velocity of the ultrasonic wave. A neural network tool is adopted to determine grain orientation from measured velocities. The TDBS results compare closely with electron backscatter diffraction (EBSD) measurements. This work expands the application of picosecond ultrasonics to three-dimensional imaging and offers a new route for the nondestructive microstructure characterization and in situ examination of polycrystalline materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of activities

Four space projects' activities are summarized. Design work on the Mars Penetrator Project, in cooperation with the NASA Ames Research Center, is being continued. Efforts are focused on the drilling mechanism which must penetrate the martian subsurface soil to collect and retrieve an uncontaminated sample. The new design consists of a rotary-percussive drill mechanism. This mechanism is optimum for dry drilling, necessary to avoid contamination of the soil sample, in many different soil types. The need for a small, relatively inexpensive device to study the chemical structure of this martian soil was also established. The egg design was chosen for its low cost compared to other systems and potential for a large number of eggs to be deployed on the martian surface. The design process included analysis of the dynamics of reentry, dissipation of heat during reentry, impact with the surface, access to undisturbed soil samples, and ability to gather samples from the soil at three depths. The egg consists of the reentry systems, soil probe lifting system, soil probe package, gas chromatograph, transmitter, and battery power supply. The egg must function only once, but is designed to withstand one martian year. The Mars Mole is designed as a rover-based device which penetrates the martian soil to a depth of up to 10 m, obtains a sample of soil, and returns it to the surface for analysis. The mole was designed to meet the following specifications: (1) weight less than 10 kg; (2) size less than 20 x 20 x 30 cm; (3) power less than 100 W; (4) ability to obtain a sample of at least 5 cc; (5) ability to penetrate fine, loose sand; and (6) need to obtain at least one sample. The space station umbilical connector project is a device which provides the translational motion of the connectors on the Space Station Freedom to allow engagement for power and data transfer. The design is capable of delivering a 20 lb force within the necessary tolerances and will operate reliably in the space environment.

Source record↗

Pressure-shear experiments on granular materials.

Pressure-shear experiments were performed on granular tungsten carbide and sand using a newly-refurbished slotted barrel gun. The sample is a thin layer of the granular material sandwiched between driver and anvil plates that remain elastic. Because of the obliquity, impact generates both a longitudinal wave, which compresses the sample, and a shear wave that probes the strength of the sample. Laser velocity interferometry is employed to measure the velocity history of the free surface of the anvil. Since the driver and anvil remain elastic, analysis of the results is, in principal, straightforward. Experiments were performed at pressures up to nearly 2 GPa using titanium plates and at higher pressure using zirconium plates. Those done with the titanium plates produced values of shear stress of 0.1-0.2 GPa, with the value increasing with pressure. On the other hand, those experiments conducted with zirconia anvils display results that may be related to slipping at an interface and shear stresses mostly at 0.1 GPa or less. Recovered samples display much greater particle fracture than is observed in planar loading, suggesting that shearing is a very effective mechanism for comminution of the grains.

36 MATERIALS SCIENCE↗

Accuracy of tip-sample interaction measurements using dynamic atomic force microscopy techniques: Dependence on oscillation amplitude, interaction strength, and tip-sample distance

Atomic force microscopy (AFM) is a versatile surface characterization method that can map a sample’s topography with high spatial resolution while simultaneously interrogating its surface chemistry through the site-specific high-resolution quantification of the forces acting between the sample and the probe tip. Thanks to considerable advances in AFM measurement technology, such local measurements of chemical properties have gained much popularity in recent years. To this end, dynamic AFM methodologies are implemented where either the oscillation frequency or the oscillation amplitude and phase of the vibrating cantilever are recorded as a function of tip-sample distance and subsequently converted to reflect tip-sample forces or interaction potentials. Such conversion has, however, been shown to produce non-negligible errors when applying the most commonly used mathematical conversion procedures if oscillation amplitudes are of the order of the decay length of the interaction. Extending on these earlier findings, the computational study presented in this paper reveals that the degree of divergence from actual values may also critically depend on both the overall strength of tip-sample interaction and the distance at which the interaction is obtained. These systematic errors can, however, be effectively eliminated by using oscillation amplitudes that are sufficiently larger than the decay length of the interaction potential.

Electrical properties and parameters↗

Reduced deuterium retention in simultaneously damaged and annealed tungsten

Deuterium (D) retention in polycrystalline tungsten (W) with copper (Cu) ion damage concurrently produced at elevated surface temperature is investigated in this paper. An in situ heated stage held W samples at a controlled temperature up to 1243 K, which were subjected to displacement damage produced by 3.4 MeV Cu ions. D retention is subsequently explored by exposure of the W samples held at 383 K to a D 2 plasma ion fluence of 10 24 D + /m 2 . Nuclear reaction analysis (NRA), utilizing the D( 3 He,p) 4 He nuclear reaction, is used to probe the D concentration in the near surface up to 6 μm. Thermal desorption spectroscopy (TDS) is used to measure outgassed HD and D 2 molecules to determine the bulk D concentration. Both NRA and TDS measure a significant reduction in D retention for samples damaged at elevated temperature. TDS quantitatively shows that the lowest energy trap remains largely unaffected while higher energy traps, induced by Cu ions, are annealed and approach intrinsic concentrations as the temperature during ion damage approaches 1243 K. Finally, analysis of TDS data yields an activation energy of (0.10 ± 0.02) eV for recovery of ion-damage induced traps at elevated temperature.

36 MATERIALS SCIENCE↗

Reexamining circular dichroism in photoemission from a topological insulator

The orbital angular momentum (OAM) of electron states is an essential ingredient for topological and quantum geometric quantities in solids. For example, Dirac surface states with helical spin- and orbital-angular momenta are a hallmark of a 3D topological insulator. Angle-resolved photoemission spectroscopy (ARPES) with variable circular light polarization, known as circular dichroism (CD), has been assumed to be a direct probe of OAM and, by proxy, of the Berry curvature of electronic bands in energy- and momentum-space. Indeed, topological surface states have been shown to exhibit angle-dependent CD (CDAD), and more broadly, CD is often interpreted as evidence of spin-orbit coupling. Meanwhile, it is well-established that CD originates from the photoemission matrix elements, which can have extrinsic contributions related to the experimental geometry and the inherently broken inversion symmetry at the sample surface. Therefore, it is important to broadly examine CD-ARPES to determine the scenarios in which it provides a robust probe of intrinsic material physics. We performed CD-ARPES on the canonical topological insulator Bi 2 ⁢Se 3 over a wide range of incident photon energies. Not only do we observe angle-dependent CD in the surface states, as expected, but we also find CD of a similar magnitude in virtually all bulk bands. Since OAM is forbidden by inversion symmetry in the bulk, we conclude this originates from symmetry-breaking in the photoemission process. Comparison with theoretical calculations supports this view and suggests that “hidden” OAM—localized to atomic sites within each unit cell—contributes significantly. Additional effects, including inter-atomic interference and final-state resonances, are responsible for the rapid variation of the CDAD signal with photon energy.

Sidilkover, Ittai [Tel Aviv University, Tel Aviv (↗

Reexamining Circular Dichroism in Photoemission From a Topological Insulator

The orbital angular momentum (OAM) of electron states is an essential ingredient for topological and quantum geometric quantities in solids. For example, Dirac surface states with helical spin- and orbital-angular momenta are a hallmark of a 3D topological insulator. Angle-resolved photoemission spectroscopy (ARPES) with variable circular light polarization, known as circular dichroism (CD), has been assumed to be a direct probe of OAM and, by proxy, of the Berry curvature of electronic bands in energy- and momentum-space. Indeed, topological surface states have been shown to exhibit angle-dependent CD (CDAD), and more broadly, CD is often interpreted as evidence of spin-orbit coupling. Meanwhile, it is well-established that CD originates from the photoemission matrix elements, which can have extrinsic contributions related to the experimental geometry and the inherently broken inversion symmetry at the sample surface. Therefore, it is important to broadly examine CD-ARPES to determine the scenarios in which it provides a robust probe of intrinsic material physics. We performed CD-ARPES on the canonical topological insulator $\mathrm{Bi}_2\mathrm{Se}_3$ over a wide range of incident photon energies. Not only do we observe angle-dependent CD in the surface states, as expected, but we also find CD of a similar magnitude in virtually all bulk bands. Since OAM is forbidden by inversion symmetry in the bulk, we conclude this originates from symmetry-breaking in the photoemission process. Comparison with theoretical calculations supports this view and suggests that $\textit{hidden}$ OAM - localized to atomic sites within each unit cell - contributes significantly. Additional effects, including inter-atomic interference and final-state resonances, are responsible for the rapid variation of the CDAD signal with photon energy.

FOS: Physical sciences↗