At least 235 records · Page 13

A heat-driven monochromatic light source

The efficiency with which heat may be converted into resonance radiation in a cesium thermionic diode is investigated theoretically. An analytical model of a thermionic converter is used which combines the coupled effects of line radiation transport, excited-state kinetics, and plasma diffusion. Operating regimes are established for various degrees of optical density in the plasma. The results indicate that monochromatic radiation can be produced with efficiencies on the order of 30 percent, provided that there is an adequate voltage drop across the plasma. A drop of 1 V was used since it can be maintained without any electrical power input to the device. It is found that high efficiencies are ude to the higher interelectrode distances which the solutions accommodate, and that radiation can be generated efficiently, even with optically dense gases.

Stefani, Francis↗

Metal-to-ceramic seals - A literature survey

Survey of unclassified literature furthers design and development of nuclear thermionic converter seals. Data cover topics which are particularly relevant to thermionics. Data are reviewed and review discussion is presented along with summary of earlier work.

Phillips, W. M.↗

Prospects of thermionic power systems

Potential thermionic power systems for space or terrestrial applications are described so that the development goals can be clearly identified. The thermionic power systems considered are a space nuclear power system, a fossil-fuel thermionic topping steam power system, a solar thermionic topping steam power system, and advanced systems. Attention is given to a discussion of the current status of technology development in thermionic converters and associated elements in power systems. Future prospects of thermionic power systems are also discussed. It is concluded that thermionic conversion has a great potential for a variety of applications.

Shimada, K.↗

Mathematical Modeling Of A Nuclear/Thermionic Power Source

Report discusses mathematical modeling to predict performance and lifetime of spacecraft power source that is integrated combination of nuclear-fission reactor and thermionic converters. Details of nuclear reaction, thermal conditions in core, and thermionic performance combined with model of swelling of fuel.

Vandersande, Jan W.↗

Nuclear thermionic power system for spacecraft

Mission studies have shown that nuclear electric propulsion is necessary for providing the needed propulsion system for detailed outer planet exploration. The study is centered around thermionic conversion based on an out-of-core approach employing heat pipes to thermally couple the nuclear reactor with the thermionic converters. Emphasis is on a parametric study to size a 500 kWe thermionic power conversion system suitable for a single shuttle launch. It is shown that out-of-core thermionic conversion results in a large L/D system that produces minimum weight. This evolving thermionic technology is compatible with developing insulator technology allowing operation at temperatures compatible with both molybdenum and insulators while retaining a sufficiently high heat rejection temperature to minimize radiator size and weight.

Phillips, W. M.↗

Closed-loop Dynamics of In-core Thermionic Reactor Systems

Using a point model of an in-core thermionic converter, alternative schemes for providing closed loop reactor control were investigated. It was found that schemes based on variable gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small-even for a complete electric load drop the emitter temperature transient is less than 100 deg K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that even though the emitter temperature distribution is about 200 deg K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗

Closed loop dynamics of in-core thermionic reactor systems.

Use of a point model of an in-core thermionic converter to investigate alternative schemes for providing closed-loop reactor control. It was found that schemes based on variable-gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small; even for a complete electric load drop the emitter temperature transient is less than 100 K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that, even though the emitter temperature distribution is about 200 K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗

Inductively coupled TI-MPD spacecraft electric propulsion

A nuclear electric propulsion concept using a thermionic reactor inductively coupled to a magnetoplasma-dynamic (MPD) accelerator is described and the results of preliminary analyses are presented. In this system, the thermionic generating unit operates continuously at a power level of approximately 0.4 MW, while the MPD thruster operates intermittently at higher voltages and power levels. Energy storage is provided by building up a large current in an inductor. Periodically, the charging current is interrupted and the energy stored in the magnetic field of the inductor is utilized for a short duration thrust pulse. A typical thrust pulse is characterized by a power level of 1 to 4 MWe, a duration of 1 msec, and a duty cycle of approximately 20%. Results of the preliminary analysis show that approximately 85 to 90% of the power available from the thermionic converter array can be delivered to the MPD thruster for a nominal 400 kWe system with an inductive unit suitable for a flight vehicle. Optimized values of the total specific mass of the system including the thermionic reactor, the inductor, and the MPD thruster are estimated in the range of 23 to 24 kg/kWe.

Britt, E. J.↗

DEXTER: A one-dimensional code for calculating thermionic performance of long converters

A versatile code is described for computing the coupled thermionic electric-thermal performance of long thermionic converters in which the temperature and voltage variations cannot be neglected. The code is capable of accounting for a variety of external electrical connection schemes, coolant flow paths and converter failures by partial shorting. Example problem solutions are included along with a user's manual.

Sawyer, C. D.↗

NEP heat pipe radiators

This paper covers improvements of heat pipe radiators for the thermionic NEP design. Liquid metal heat pipes are suitable as spacecraft radiator elements because of high thermal conductance, low mass and reliability, but the NEP thermionic system design was too large and difficult to fabricate. The current integral collector-radiator design consisting of several layers of thermionic converters, the annular-tangential collector heat pipe, the radiator heat pipe, and the transition zone designed to minimize the temperature difference between the collector heat pipe and radiator heat pipe are described. Finally, the design of micrometeoroid armor protection and the fabrication of the stainless steel annular heat pipe with a tangential arm are discussed, and it is concluded that the heat rejection system for the thermionic NEP system is well advanced, but the collector-radiator heat pipe transition and the 8 to 10 m radiator heat pipe with two bends require evaluation.

Ernst, D. M.↗

Dexter - A one-dimensional code for calculating thermionic performance of long converters.

This paper describes a versatile code for computing the coupled thermionic electric-thermal performance of long thermionic converters in which the temperature and voltage variations cannot be neglected. The code is capable of accounting for a variety of external electrical connection schemes, coolant flow paths and converter failures by partial shorting. Example problem solutions are given.

Sawyer, C. D.↗

Distillation device supplies cesium vapor at constant pressure

Distillation apparatus in the form of a U tube supplies small amounts of pure cesium vapor at constant pressure to a thermionic converter. The upstream leg of the U tube is connected to a vacuum pump to withdraw noncondensable impurities, the bottom portion serves as a reservoir for the liquid cesium.

Basiulis, A.↗