SEARCH · Search NASA
Results for “TIME”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Monte Carlo Simulations of High-speed, Time-gated MCP-based X-ray Detectors: Saturation Effects in DC and Pulsed Modes and Detector Dynamic Range
We present here results of continued efforts to understand the performance of microchannel plate (MCP)–based, high-speed, gated, x-ray detectors. This work involves the continued improvement of a Monte Carlo simulation code to describe MCP performance coupled with experimental efforts to better characterize such detectors. Our goal is a quantitative description of MCP saturation behavior in both static and pulsed modes. We have developed a new model of charge buildup on the walls of the MCP channels and measured its effect on MCP gain. The results are compared to experimental data obtained with a short-pulse, high-intensity ultraviolet laser; these results clearly demonstrate MCP saturation behavior in both DC and pulsed modes. The simulations compare favorably to the experimental results. The dynamic range of the detectors in pulsed operation is of particular interest when fielding an MCP–based camera. By adjusting the laser flux we study the linear range of the camera. These results, too, are compared to our simulations.
Time-dependent density functional theory for ion diffusion in electrochemical systems
Explore the source record for details and available documents.
Conventional and acoustic surface plasmons on noble metal surfaces: a time-dependent density functional theory study
Explore the source record for details and available documents.
Electron Transfer in Hydrogenated Nanocrystalline Silicon Observed by Time-Resolved Terahertz Spectroscopy
Abstract not provided
Photoinduced changes in the cuprate electronic structure revealed by femtosecond time- and angle-resolved photoemission
Explore the source record for details and available documents.
Generic Mechanism of Optimal Energy Transfer Efficiency: A Scaling Theory of the Mean First-Passage Time in Exciton Systems
Explore the source record for details and available documents.
EMBERS: EpheMeral Biometrically Enhanced Real-time location System.
Abstract not provided.
Supervisory System for a Wide Area Damping Controller Using PDCI Modulation and Real-Time PMU Feedback.
Abstract not provided.
Effect of Time Delay Asymmetries in Power System Damping Control.
Abstract not provided.
Time Delay Definitions and Characterization in the Pacific DC Intertie Wide Area Damping Controller.
Abstract not provided.
Cygnus System Timing
Explore the source record for details and available documents.
A new time-dependent analytic compact model for radiation-induced photocurrent in epitaxial structures.
Abstract not provided.
On the ""early-time"" evolution of variables relevant to turbulence models for the Rayleigh-Taylor instability
Abstract Not Provided
Adaptive Model Predictive Control for Real-Time Dispatch of Energy Storage Systems.
Abstract not provided.
Laser ranging to lunar retroreflectors - A. Signal detection, location in range-time, and timing precision. B. Laser pulse uniformity and timing
Laser ranging to lunar retroreflectors
Night‐time electromechanical activation time, pulsatile hemodynamics, and discharge outcomes in patients with acute heart failure
Abstract Aims Both electromechanical activation time (EMAT) and pulsatile hemodynamics measured during the hospitalization course are useful in the prediction of cardiovascular outcomes in patients with acute heart failure syndrome (AHFS). We investigated whether night‐time monitoring of EMAT with the ambulatory acoustic cardiography is superior to the measures of pulsatile hemodynamics for prediction of AHFS post‐discharge outcomes. Methods and results A total of 97 patients (71.1 ± 15.4 years old, 81% male, and 73.8% systolic heart failure) hospitalized for AHFS were included. Before discharge, 24 h ambulatory acoustic cardiography and a comprehensive echocardiographic and pulsatile hemodynamic study were performed to assess the mean 24 h, daytime, and night‐time EMAT, carotid systolic blood pressure (SBP) and pulse pressure (PP), amplitude of the reflected pressure wave from a decomposed carotid pressure wave (Pb), and carotid–femoral pulse wave velocity (cfPWV), in addition to measurement of N‐terminal pro‐brain natriuretic peptide (NT‐proBNP) levels. During a mean follow‐up of 389 ± 281 days, 49 patients (50.5%) experienced events including re‐hospitalization for heart failure, myocardial infarction, stroke, or death. Pulsatile hemodynamics, including carotid SBP and PP and Pb, but not cfPWV, and night‐time EMAT, but not daytime EMAT, significantly predicted post‐discharge events when age and NT‐proBNP were accounted for (all P < 0.05). In a final model with adjustment for age and NT‐proBNP, night‐time EMAT, but not Pb, significantly predicted post‐discharge events [hazard ratio per 1 SD and 95% confidence intervals: 1.33 (1.05–1.69), P < 0.05]. Conclusion Pre‐discharge night‐time EMAT may be a better predictor for post‐discharge adverse events than the measures of the pulsatile hemodynamics in patients with AHFS.
Large-Strain Time-Temperature Equivalence and Adiabatic Heating of Polyethylene
Time-temperature equivalence is a well-known phenomenon in time-dependent material response, where rapid events at a moderate temperature are indistinguishable from some occurring at modest rates but elevated temperatures. However, there is as-yet little elucidation of how well this equivalence holds for substantial plastic strains. In this work, we demonstrate time-temperature equivalence over a large range in a previously studied high-density polyethylene formulation (HDPE). At strain-rates exceeding 0.1/s, adiabatic heating confounds the comparison of nominally isothermal material response, apparently violating time-temperature equivalence. Strain-rate jumps can be employed to access the instantaneous true strain rate without heating. Adiabatic heating effects were isolated by comparing a locus of isothermal instantaneous flow stress measurements from strain-rate jumps up to 1/s with the predicted equivalent states at 0.01/s and 0.001/s in compression. Excellent agreement between the isothermal jump condition locus and the quasi-static tests was observed up to 50% strain, yielding one effective isothermal plastic response for each material for a given time-temperature equivalent state. These results imply that time-temperature equivalence can be effectively used to predict the deformation response of polymers during extreme mechanical events (large strain and high strain-rate) from measurements taken at reduced temperatures and nominal strain-rates in the laboratory.