Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Neutron-induced fission cross section of {sup 234}U and {sup 237}Np measured at the CERN Neutron Time-of-Flight (n{sub T}OF) facility

A high-resolution measurement of the neutron-induced fission cross section of {sup 234}U and {sup 237}Np has been performed at the CERN Neutron Time-of-Flight facility. The cross sections have been determined in a wide energy range from 1 eV to 1 GeV using the evaluated {sup 235}U cross section as reference. In these measurements the energy determination for the {sup 234}U resonances could be improved, whereas previous discrepancies for the {sup 237}Np resonances were confirmed. New cross-section data are provided for high neutron energies that go beyond the limits of prior evaluations, obtaining important differences in the case of {sup 237}Np.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemical imaging of molecular changes in a hydrated single cell by dynamic secondary ion mass spectrometry and super-resolution microscopy

Chemical imaging of single cells is important in capturing biological dynamics. Single cell correlative imaging is realized between structured illumination microscopy (SIM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) using System for Analysis at the Liquid Vacuum Interface (SALVI), a multimodal microreactor. SIM characterized cells and guided subsequent ToF-SIMS analysis. Dynamic ToF-SIMS provided time- and space-resolved cell molecular mapping. Lipid fragments were identified in the hydrated cell membrane. Principal component analysis was used to elucidate chemical component differences among mouse lung cells that uptake zinc oxide nanoparticles. Our results provided submicron chemical spatial mapping for investigations of cell dynamics at the molecular level.

correlative chemical imaging • microfluidic • surf↗

Correlative Surface Imaging Reveals Chemical Signatures for Bacterial Hotspots on Plant Roots

The rhizosphere is arguably the most complex microbial habitat on earth, comprising an integrated network of plant roots, soil and a highly diverse microbial community (the rhizosphere microbiome)1. Understanding, predicting and controlling plant-microbe interactions in the rhizosphere will allow us to harness the plant microbiome as a means to increase or restore plant ecosystem productivity, improve plant responses to a wide range of environmental perturbations, and mitigate effects of climate change by designing ecosystems for long-term soil carbon storage1. To this end, it is imperative to develop new molecular approaches with high spatial resolution to capture interactions at the plant-microbe, microbe-microbe, and plant-plant interfaces. In this work, we designed an imaging sample holder that allows integrated surface imaging tools to map the same locations of a plant root-microbe interface with submicron lateral resolutions, providing novel in vivo analysis of root-microbe interactions. Specifically, confocal fluorescence microscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), and scanning electron microscope (SEM) were used for the first time for correlative imaging of the Brachypodium distachyon root and its interaction with Pseudomonas SW25, a typical plant growth-promoting soil bacterium. Imaging data suggest that the root surface is inhomogeneous and that the interaction between Pseudomonas and Brachypodium roots was confined to only few spots along the sampled root segments and that the bacterial attachment spots were enriched in Na- and S-related and high-mass organic species. We conclude that attachment of the Pseudomonas cells to the root surface is outcompeted by strong root-soil mineral interactions but facilitated by formation of extracellular polymeric substances (EPS).

Plant root, Plant growth-promoting bacteria, soil,↗

PID techniques: Alternatives to RICH Methods

In this review article we discuss the recent progress in PID techniques other than the RICH methods. In particular we mention the recent progress in the Transition Radiation Detector (TRD), dE/dx cluster counting, and Time Of Flight (TOF) techniques. The TRD technique is mature and has been tried in many hadron colliders. It needs space though, about 20cm of detector radial space for every factor of 10 in the {pi}/e rejection power, and this tends to make such detectors large. Although the cluster counting technique is an old idea, it was never tried in a real physics experiment. Recently, there are efforts to revive it for the SuperB experiment using He-based gases and waveform digitizing electronics. A factor of almost 2 improvement, compared to the classical dE/dx performance, is possible in principle. However, the complexity of the data analysis will be substantial. The TOF technique is well established, but introduction of new fast MCP-PMT and G-APD detectors creates new possibilities. It seems that resolutions below 20-30ps may be possible at some point in the future with relatively small systems, and perhaps this could be pushed down to 10-15ps with very small systems, assuming that one can solve many systematic issues. However, the cost, rate limitation, aging and cross-talk in multi-anode devices at high BW are problems. There are several groups working on these issues, so progress is likely. Table 6 summarizes the author's opinion of pros and cons of various detectors presented in this paper based on their operational capabilities. We refer the reader to Ref.40 for discussion of other more general limits from the PID point of view.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection system for high-resolution gamma radiation spectroscopy with neutron time-of-flight filtering

A .gamma.-radiation detection system that includes at least one semiconductor detector such as HPGe-Detector, a position-sensitive .alpha.-Detector, a TOF Controller, and a Digitizer/Integrator. The Digitizer/Integrator starts to process the energy signals of a .gamma.-radiation sent from the HPGe-Detector instantly when the HPGe-Detector detects the .gamma.-radiation. Subsequently, it is determined whether a coincidence exists between the .alpha.-particles and .gamma.-radiation signal, based on a determination of the time-of-flight of neutrons obtained from the .alpha.-Detector and the HPGe-Detector. If it is determined that the time-of-flight falls within a predetermined coincidence window, the Digitizer/Integrator is allowed to continue and complete the energy signal processing. If, however, there is no coincidence, the Digitizer/Integrator is instructed to be clear and reset its operation instantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and characterization of perovskite-type Sr{sub x}Y{sub 1−x}FeO{sub 3−δ} (0.63≤x<1.0) and Sr{sub 0.75}Y{sub 0.25}Fe{sub 1−y}M{sub y}O{sub 3−δ} (M=Cr, Mn, Ni), (y=0.2, 0.33, 0.5)

Oxygen-deficient ferrates with the cubic perovskite structure Sr{sub x}Y{sub 1−x}FeO{sub 3−δ} were prepared in air (0.71≤x≤0.91) as well as in N{sub 2} (x=0.75 and 0.79) at 1573 K. The oxygen content of the compounds prepared in air increases with increasing strontium content from 3−δ=2.79(2) for x=0.75 to 3−δ=2.83(2) for x=0.91. Refinement of the crystal structure of Sr{sub 0.75}Y{sub 0.25}FeO{sub 2.79} using TOF neutron powder diffraction (NPD) data shows high anisotropic atomic displacement parameter (ADP) for the oxygen atom resulting from a substantial cation and anion disorder. Electron diffraction (ED) and high-resolution electron microscopy (HREM) studies of Sr{sub 0.75}Y{sub 0.25}FeO{sub 2.79} reveal a modulation along 〈1 0 0〉{sub p} with G± ∼0.4〈1 0 0〉{sub p} indicating a local ordering of oxygen vacancies. Magnetic susceptibility measurements at 5–390 K show spin-glass behaviour with dominating antiferromagnetic coupling between the magnetic moments of Fe cations. Among the studied compositions, Sr{sub 0.75}Y{sub 0.25}FeO{sub 2.79} shows the lowest thermal expansion coefficient (TEC) of 10.5 ppm/K in air at 298–673 K. At 773–1173 K TEC increases up to 17.2 ppm/K due to substantial reduction of oxygen content. The latter also results in a dramatic decrease of the electrical conductivity in air above 673 K. Partial substitution of Fe by Cr, Mn and Ni according to the formula Sr{sub 0.75}Y{sub 0.25}Fe{sub 1−y}M{sub y}O{sub 3−δ} (y=0.2, 0.33, 0.5) leads to cubic perovskites for all substituents with y=0.2. Their TECs are higher in comparison with un-doped Sr{sub 0.75}Y{sub 0.25}FeO{sub 2.79}. Only M=Ni has increased electrical conductivity compared to un-doped Sr{sub 0.75}Y{sub 0.25}FeO{sub 2.79}. - Graphical abstract: Oxygen-deficient ferrates with the cubic perovskite structure Sr{sub x}Y{sub 1−x}FeO{sub 3−δ} were prepared both in air (0.71≤x≤0.91) and N{sub 2} (x=0.75 and 0.79) at 1573 K. Refinement of the crystal structure of Sr{sub 0.75}Y{sub 0.25}FeO{sub 2.79} using TOF neutron powder diffraction (NPD) data (S.G. Pm-3m, a=3.86455(3) Å; χ{sup 2}=6.71, R{sub p}=0.03; R{sub wp}=0.04) confirmed the cubic perovskite structure. The observed high anisotropic atomic displacement parameter for the oxygen atom indicates a substantial anion sublattice disorder. Electron diffraction (ED) and high-resolution electron microscopy (HREM) studies of Sr{sub 0.75}Y{sub 0.25}FeO{sub 2.79} show compositional modulation along 〈1 0 0〉{sub p} with G± ∼0.4〈1 0 0〉{sub p} indicating ordering of oxygen vacancies at the local scale. Highlights: ► Cubic perovskites Sr{sub x}Y{sub 1−x}FeO{sub 3−δ} (0.71≤x<0.91) were synthesized. ► Sr{sub 0.75}Y{sub 0.25}Fe{sub 1−y}M{sub y}O{sub 3−δ}, M=Cr, Mn, Ni were prepared. ► High-temperature conductivity properties and crystal structure were studied. ► High-temperature thermal expansion behavior was investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MALDI MS Imaging at Acquisition Rates Exceeding 100 Pixels per Second

The practicality of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) applied to molecular imaging of biological tissues is limited by the analysis speed. Typically, a relatively low speed of stop-and-go micromotion of XY stages is considered as a factor substantially reducing the rate with which fresh sample material can be supplied to the laser spot. The sample scan rate in our laboratory-built high-throughput imaging TOF mass spectrometer was significantly improved through the use of a galvanometer-based optical scanner performing fast laser spot repositioning on a target plate. The optical system incorporated into the ion source of our MALDI TOF mass spectrometer allowed focusing the laser beam via a modified grid into a 10-μm round spot. This permitted the acquisition of high-resolution MS images with a well-defined pixel size at acquisition rates exceeding 100 pixel/s. The influence of selected parameters on the total MS imaging time is discussed. The new scanning technique was employed to display the distribution of an antitumor agent in 3D colorectal adenocarcinoma cell aggregates; a single MS image comprising 100 × 100 pixels with 10-μm lateral resolution was recorded in approximately 70 s. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument development continues in Oak Ridge

Peer review panels composed of 80 external scientists recently visited Oak Ridge National Laboratory (ORNL) to review almost 700 proposals for experiments on 23 instruments at the Spallation Neutron Source (SNS) and High Flux Isotope Reactor (HFIR). These were proposed for the time period from January-June 2012. About 40% of the proposals were approved for beam time and 20% were placed on an alternate list if time becomes available. The Hybrid Spectrometer HYSPEC at SNS began its commissioning in September 2011. HYSPEC is otpimized for studying low energy dynamics in single-crystal samples using a broad variety of sample environments, and is equipped with a polarization analysis capability. It is expected to be available for users on a limited basis in the second half of 2012. The detector tank of CORELLI has been installed on beamline 9 at SNS. Now that the tank is in place, banks of neutron detectors and boron carbide shielding will be installed around the interior. CORELLI is optimized to probe complex disorder in crystalline materials through diffuse scattering from single-crystal samples. It will begin commissioning in 2014. CORELLI is one of four instruments being developed under the SING II (SNS Instruments Next Generation II) project. The others are the Macromolecular Neutron Diffractometer (MANDI), the Vibrational Spectrometer (VISION, scheduled to begin commissioning in 2012), and the Time of Flight Ultra Small Angle Neutron Scattering Instrument (TOF-USANS). The single crystal neutron diffractometer IMAGINE, was deliverd to HFIR in October 2011. Preliminary testing has been carried out. IMAGINE will provide atomic resolution information on chemical, organic, metallo-organic and protein single crystals that will enable their chemical, physical and biological structure and function to be understood. This instrument will benefit scientists with interests in pharmaceuticals, minerals and other inorganic crystals, small molecules, molecular organo-metallic crystals and metal-organic frameworks (MOFs) molecular crystal structures. The quasi-Laue geometry, combined with a large solid angle detector, will enable rapid data collection from crystals with volume < 1mm{sup 1} and unit cell < 100 {angstrom}. Construction and installation of the optical system is in progress. Commissioning is expected to start in April 2012.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and modeling results to describe the performance of a field emission electron gun as employed in the Volatile Analysis by Pyrolysis of Regolith (VAPoR) TOF-MS prototype.

Southard, Adrian E.↗

Investigating the Effects of Chemical Gradients on Performance and Reliability within Perovskite Solar Cells with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS), a powerful analytical technique sensitive to all components of perovskite solar cell (PSC) materials, can differentiate between the various organic species within a PSC absorber or a complete device stack. The ability to probe chemical gradients through the depth of a device (both organic and inorganic), with down to 100 nm lateral resolution, can lead to unique insights into the relationships between chemistry in the absorber bulk, at grain boundaries, and at interfaces as well as how they relate to changes in performance and/or stability. In this essay, the technique is described; then, from the literature, several examples of how TOF-SIMS have been used to provide unique insight into PSC absorbers and devices are covered. Finally, the common artifacts that can be introduced if the data are improperly collected, as well as methods to mitigate these artifacts are discussed.

14 SOLAR ENERGY↗

Integration of High-Resolution Mass Spectrometry with Cryogenic Ion Vibrational Spectroscopy

We describe an instrumental configuration for the structural characterization of fragment ions generated by collisional dissociation of peptide ions in the typical MS{sup 2} scheme widely used for peptide sequencing. Structures are determined by comparing the vibrational band patterns displayed by cryogenically cooled ions with calculated spectra for candidate structural isomers. These spectra were obtained in a linear action mode by photodissociation of weakly bound D{sub 2} molecules. This is accomplished by interfacing a Thermo Fisher Scientific Orbitrap Velos Pro to a cryogenic, triple focusing time-of-flight photofragmentation mass spectrometer (the Yale TOF spectrometer). The interface involves replacement of the Orbitrap’s higher-energy collisional dissociation cell with a voltage-gated aperture that maintains the commercial instrument’s standard capabilities while enabling bidirectional transfer of ions between the high-resolution FT analyzer and external ion sources. The performance of this hybrid instrument is demonstrated by its application to the a{sub 1}, y{sub 1} and z{sub 1} fragment ions generated by CID of a prototypical dipeptide precursor, protonated L-phenylalanyl-L-tyrosine (H{sup +}-Phe-Tyr-OH or FY-H{sup +}). The structure of the unusual z{sub 1} ion, nominally formed after NH{sub 3} is ejected from the protonated tyrosine (y{sub 1}) product, is identified as the cyclopropane-based product is tentatively identified as a cyclopropane-based product. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New beam line for time-of-flight medium energy ion scattering with large area position sensitive detector

A new beam line for medium energy ion mass scattering (MEIS) has been designed and set up at the Angstroem laboratory, Uppsala University, Sweden. This MEIS system is based on a time-of-flight (ToF) concept and the electronics for beam chopping relies on a 4 MHz function generator. Repetition rates can be varied between 1 MHz and 63 kHz and pulse widths below 1 ns are typically obtained by including beam bunching. A 6-axis goniometer is used at the target station. Scattering angle and energy of backscattered ions are extracted from a time-resolved and position-sensitive detector. Examples of the performance are given for three kinds of probing ions, {sup 1}H{sup +}, {sup 4}He{sup +}, and {sup 11}B{sup +}. Depth resolution is in the nanometer range and 1 and 2 nm thick Pt layers can easily be resolved. Mass resolution between nearby isotopes can be obtained as illustrated by Ga isotopes in GaAs. Taking advantage of the large size detector, a direct imaging (blocking pattern) of crystal channels are shown for hexagonal, 4H-SiC. The ToF-MEIS system described in this paper is intended for use in semiconductor and thin film areas. For example, depth profiling in the sub nanometer range for device development of contacts and dielectric interfaces. In addition to applied projects, fundamental studies of stopping cross sections in this medium energy range will also be conducted.

43 PARTICLE ACCELERATORS↗

SU-F-J-206: Systematic Evaluation of the Minimum Detectable Shift Using a Range- Finding Camera

Purpose: The robotic table used for patient alignment in proton therapy is calibrated only at commissioning under well-defined conditions and table shifts may vary over time and with differing conditions. The purpose of this study is to systematically investigate minimum detectable shifts using a time-of-flight (TOF) range-finding camera for table position feedback. Methods: A TOF camera was used to acquire one hundred 424 × 512 range images from a flat surface before and after known shifts. Range was assigned by averaging central regions of the image across multiple images. Depth resolution was determined by evaluating the difference between the actual shift of the surface and the measured shift. Depth resolution was evaluated for number of images averaged, area of sensor over which depth was averaged, distance from camera to surface, central versus peripheral image regions, and angle of surface relative to camera. Results: For one to one thousand images with a shift of one millimeter the range in error was 0.852 ± 0.27 mm to 0.004 ± 0.01 mm (95% C.I.). For varying regions of the camera sensor the range in error was 0.02 ± 0.05 mm to 0.47 ± 0.04 mm. The following results are for 10 image averages. For areas ranging from one pixel to 9 × 9 pixels the range in error was 0.15 ± 0.09 to 0.29 ± 0.15 mm (1σ). For distances ranging from two to four meters the range in error was 0.15 ± 0.09 to 0.28 ± 0.15 mm. For an angle of incidence between thirty degrees and ninety degrees the average range in error was 0.11 ± 0.08 to 0.17 ± 0.09 mm. Conclusion: It is feasible to use a TOF camera for measuring shifts in flat surfaces under clinically relevant conditions with submillimeter precision.

60 APPLIED LIFE SCIENCES↗

High-Spatial-Resolution Quantitative Chemomechanical Mapping of Organic Composite Cathodes for Sulfide-Based Solid-State Batteries

Understanding the chemo-mechanical behaviors of electrodes, particularly at the electrode/electrolyte interfaces, is critical for improving the performance of all-solid-state batteries. However, due to the instability of electrolyte materials under ambient conditions, such characterizations are challenging, particularly for sulfide-based all-solid-state batteries. Herein, by combining time-of-flight secondary-ion mass spectroscopy (ToF-SIMS) and in-SEM nanoindentation measurements, a systematic quantitative investigation of the chemo-mechanical behaviors of pyrene-4,5,9,10-tetraone (PTO) /Li 6 PS 5 Cl composite cathodes is carried out. Chemical and quantitative mechanical information of the composite cathode were collected with high spatial resolution after developing and implementing an air-free characterization protocol. By directly connecting the Young’s modulus and hardness with the Li distribution in the composite cathode, a comprehensive chemo-mechanical mapping of the PTO/ Li 6 PS 5 Cl composite cathode has been established. Furthermore, this work improves our knowledge of the critical chemo-mechanical phenomena that occur at the cathode/electrolyte interfaces in all-solid-state batteries.

25 ENERGY STORAGE↗

Trace gases at TRACER ANC site

Speciated volatile organic compounds (VOCs) were measured using an Ionicon PTR-TOF 8000 from 20 June to 3 July 2022 at the TRACER ancillary (TRACER ANC) site in Guy, TX. The dataset is reported at 1-min time resolution. Mixing ratios (ppb) are provided for acetone, methanol, acetaldehyde, dimethyl sulfide (DMS), furan, isoprene, methyl vinyl ketone plus methyl ethyl ketone (MVK + MEK), terpenes, xylene, and trimethylbenzene. Instrument calibrations for these species were performed weekly using a certified gas standard.

acetaldehyde↗

Multielement analysis of interplanetary dust particles using TOF-SIMS

Sections of three stratospheric particles (U2015G1, W7029*A27, and L2005P9) were analyzed with TOF-SIMS (Time Of Flight-Secondary Ion Mass Spectrometry) continuing our efforts to investigate the element distribution in interplanetary dust particles (IDP's) with high lateral resolution (approximately 0.2 micron), to examine possible atmospheric contamination effects, and to further explore the abilities of this technique for element analysis of small samples. The samples, previously investigated with SXRF (synchrotron X-ray fluorescence analysis), are highly enriched in Br (Br/Fe: 59 x CI, 9.2 x CI, and 116 x CI, respectively). U2015G1 is the IDP with the by far highest Zn/Fe-ratio (81 x CI) ever reported in chondritic particles.

Stephan, T.↗

Volatile Organic Compounds and Meteorological Conditions in the Missouri Ozark AmeriFlux (MOFLUX) Site, 2023

This data set contains measurements of atmospheric components and meteorological conditions of central Missouri, United States during the summer of 2023. Data serve to examine the impact of meteorological conditions relevant to future climate on the emission and transformation of volatile organic compounds (VOCs). During the field campaign, researchers were also able to incorporate opportunistic analyses of the long-range transport of smoke plumes generated from extreme forest fire activities in Canada. VOC measurements were conducted at the Missouri Ozark AmeriFlux (MOFLUX) site (latitude 38.7441, longitude −92.2000) using a proton transfer reaction time of flight mass spectrometer (PTR-ToF-MS 6000 X2). The sampling campaign was conducted during the summer of 2023 (2023-06-25 to 2023-08-12) with measurements being taken at high temporal resolution (1 hour). Particular VOCs analyzed include: Methanol, Acetonitrile, Acetone, Isoprene, Methylvinyl ketone (MVK) and methacrolein (MACr), Benzene, Toluene, Catechol, and Monoterpene. Meteorological parameters included in this dataset were collected from a nearby Columbia Regional Airport (~10 km). Global solar radiation data were measured at a weather site in Ashland, MO, 5.22 km from the MOFLUX tower. The data were accessed using the MesoWest online website (https://mesowest.utah.edu/) provided by the Department of Atmospheric Sciences, University of Utah. Discussion of the data providers, database, and dissemination were highlighted in prior studies (Horel et al., 2002a; Horel et al., 2002b) . Smoke mixing ratios (in mg m−3) were estimated from the High-Resolution Rapid Refresh (HRRR) 3 km weather model for Missouri at 6-hour intervals (Dowell et al., 2022). This dataset contains three data files in comma separate (*.csv) format. Additional metadata are provided: three data dictionaries and a file-level metadata file in comma separate (*.csv) format and a user guide in PDF (*.pdf) format.

Acetone↗

High-accuracy {sup 233}U(n,f) cross-section measurement at the white-neutron source n{sub T}OF from near-thermal to 1 MeV neutron energy

The {sup 233}U(n,f) cross section has been measured at the white neutron source n{sub T}OF in a wide energy range with a dedicated fission ionization chamber. We report here the results from {approx}30 meV to 1 MeV neutron energy. The {sup 233}U(n,f) cross section has been determined relative to a reference sample of {sup 235}U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n{sub T}OF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous measurements, and indicated that even the latest evaluations underestimate the cross section in the epithermal region. The present high-quality data provide the basis for a more precise evaluation of the {sup 233}U fission cross section and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗