Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOXICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Relative toxicity of the pyrolysis products from some thermoplastic and thermoset polymers

Relative toxicity data on the pyrolysis products of a variety of thermoplastic and thermoset polymers are presented. The data are presented in terms of time to incapacitation and time to death with a fixed sample weight of 1.0 g, and in terms of the apparent lethal concentration required to produce 50 percent mortality within a fixed exposure period of 30 min.

Kourtides, D. A.↗

Effect of foam age on toxicity of pyrolysis gases from polyurethane flexible foams

The toxicity of the pyrolysis gases from some samples of polyurethane flexible foams appears to have decreased with age, while other samples seem to exhibit no significant change with age in this respect. The changes observed were greater than could be accounted for by variations in the material, or test variations or artifacts.

Hilado, C. J.↗

Fire resistivity and toxicity studies of candidate aircraft passenger seat materials

This paper describes fire resistivity studies of a wide range of candidate nonmetallic materials for the construction of improved fire resistant aircraft passenger seats. These materials were evaluated on the basis of FAA airworthiness burn and smoke generation tests, colorfastness, and animal toxicity tests. Physical, mechanical, and aesthetic properties were also included in the evaluations. Candidate seat materials that have significantly improved thermal response to various thermal loads corresponding to reasonable fire threats, as they relate to in-fight fire situations, are identified.

Fewell, L. L.↗

Statistical studies of animal response data from USF toxicity screening test method

Statistical examination of animal response data obtained using Procedure B of the USF toxicity screening test method indicates that the data deviate only slightly from a normal or Gaussian distribution. This slight departure from normality is not expected to invalidate conclusions based on theoretical statistics. Comparison of times to staggering, convulsions, collapse, and death as endpoints shows that time to death appears to be the most reliable endpoint because it offers the lowest probability of missed observations and premature judgements.

Hilado, C. J.↗

Relative toxicity of pyrolysis gases from materials - Effects of chemical composition and test conditions

Relative toxicity test data on 270 materials are presented, based on test procedures developed at the University of San Francisco. The effects of chemical composition, using data on 13 types of synthetic polymers and eight types of fabrics, are discussed. Selected materials were evaluated using nine test conditions with the USF method, and using methods developed at the FAA Civil Aeromedical Institute, Douglas Aircraft Company and San Jose State University.

Hilado, C. J.↗

Less-toxic corrosion inhibitors

Combinations of borates, nitrates, phosphates, silicates, and sodium MBT protect aluminum from corrosion in fresh water. Most effective combinations contained sodium phosphate and were alkaline. These inhibitors replace toxic chromates which are subject to governmental restrictions, but must be used in larger quantities. Experimental exposure times varied from 1 to 14 months depending upon nature of submersion solution.

Humphries, T. S.↗

Relative toxicity testing of spacecraft materials. 1: Spacecraft materials

In chamber thermodegradation procedures were used to access the lethality to rats of the pyrolysis/combustion products of three foams, an adhesive backed metallic tape and RTV silicone rubber adhesive sealant used in spacecraft construction. The role of carbon monoxide in the overall pyrolysate toxicity was also investigated. Post exposure observation of the rats, histological evaluation of selected organs, carbon monoxide concentration in the chamber atmosphere during exposure and the percent carboxyhemoglobin in the animals expiring in the chamber are discussed. Thermogravimetric analysis and dosage response results are given. The lethal effect of the RTV silicon appears to be due to physical obstruction of the respiratory system by particulate matter from pyrolysis.

Lawrence, W. H.↗

Relative toxicity testing of spacecraft materials. 2: Aircraft materials

The relative toxicity of thermodegradation (pyrolysis/combustion) products of aircraft materials was studied. Two approaches were taken to assess the biological activity of the pyrolysis/combustion products of these materials: (1) determine the acute lethality to rats from inhalation of these pyrolysates and (2) examine the tendency for sublethal exposure to the pyrolysates to disrupt behavioral (shock avoidance) performance of exposed rats. The ralative importance of lethality vs. behavioral effects in selection of a material may be dictated by whether or not individuals potentially exposed to such products, would have an opportunity to escape if they were behaviorally capable of doing so. If so, the second parameter would assume greater importance, but if not the first parameter may be of much greater importance in selecting materials.

Lawrence, W. H.↗

Effect of type of explosives and physical-mechanical properties of explosive rock on formation of toxic gases in atmosphere of shafts

The quality of toxic gases formed during explosive work in underground shafts depends upon the type of explosives and the conditions of explosion. Several types of explosives and rocks were examined. All remaining conditions were maintained the same (sandy-argillaceous stemming, electrical method of explosions, diameter of blast holes, and the direct triggering of charges).

Mindeli, E. O.↗

Reproducibility of polycarbonate reference material in toxicity evaluation

A specific lot of bisphenol A polycarbonate has been used for almost four years as the reference material for the NASA-USF-PSC toxicity screening test method. The reproducibility of the test results over this period of time indicate that certain plastics may be more suitable reference materials than the more traditional cellulosic materials.

Hilado, C. J.↗

Non-toxic invert analog glass compositions of high modulus

Glass compositions having a Young's modulus of at least 15 million psi are described. They and a specific modulus of at least 110 million inches consist essentially of, in mols, 15 to 40% SiO2, 6 to 15% Li2O, 24 to 45% of at least two bivalent oxides selected from the group consisting of Ca, NzO, MgO and CuO; 13 to 39% of at least two trivalent oxides selected from the group consisting of Al2O3, Fe2O3, B2O3, La2O3, and Y2O3 and up to 15% of one or more tetravelent oxides selected from the group consisting of ZrO2, TiO2 and CeO2. The high modulus, low density glass compositions contain no toxic elements. The composition, glass density, Young's modulus, and specific modulus for 28 representative glasses are presented. The fiber modulus of five glasses are given.

Bacon, J. F.↗

Destroying Toxic Wastes

Toxic pesticides and halogenated hydrocarbons converted to fuels and harmless waste by catalyzed combustion. These product gases used directly as fuel or catalytically converted to methanol.

Voecks, G. E.↗

Rapid toxicity detection in water quality control utilizing automated multispecies biomonitoring for permanent space stations

The objective of this study was to evaluate proposed design characteristics and applications of automated biomonitoring devices for real-time toxicity detection in water quality control on-board permanent space stations. Simulated tests in downlinking transmissions of automated biomonitoring data to Earth-receiving stations were simulated using satellite data transmissions from remote Earth-based stations.

Morgan, E. L.↗

Rapid Dry Etching Of Photoresists Without Toxic Gases

Experimental dry etching technique strips photoresists from semiconductor wafers without damaging semiconductor materials. Makes use of afterglow existing downstream from plasma generated by radio-frequency electric field. Constituents of afterglow react with sacrificial polymer to make reactive gases that quickly etch-away photoresist. Strips quickly at room temperature; not necessary to heat substrates. No hazardous or toxic chemicals used.

Lerner, Narcinda R.↗

Space Station Freedom Toxic and Reactive Materials Handling

Viable research in materials processing in space requires the utilization of a wide variety of chemicals and materials, many of which are considered toxic and/or highly reactive with other substances. A realistic view of the experiments which are most likely to be accomplished in the early Space Station phases are examined and design issues addressed which are related to their safe implementation. Included are discussions of materials research on Skylab, Spacelab, and the Shuttle mid-deck; overviews of early concepts for specialized Space Station systems designed to help contain potential problems; descriptions of industrial experience with ground-based research; and an overview of the state-of-the-art in contamination detection systems.

Baugher, Charles R.↗

Low toxicity high temperature PMR polyimide

In-situ polymerization of monomer reactants (PMR) type polyimides constitute an important class of ultra high performance composite matrix resins. PMR-15 is the best known and most widely used PMR polyimide. An object of the present invention is to provide a substantially improved high temperature PMR-15 system that exhibits better processability, toughness, and thermo-oxidative stability than PMR-15, as well as having a low toxicity. Another object is to provide new PMR polyimides that are useful as adhesives, moldings, and composite matrices. By the present invention, a new PMR polyimide comprises a mixture of the following compounds: 3,4'-oxydianiline (3,4'-ODA), NE, and BTDE which are then treated with heat. This PMR was designated LaRC-RP46 and has a broader processing window, better reproducibility of high quality composite parts, better elevated temperature mechanical properties, and higher retention of mechanical properties at an elevated temperature, particularly, at 371 C.

Pater, Ruth H.↗

Toxic substances registry system. Index of material safety data sheets

The January 1995 revision of the index of material safety data sheets is presented. The index of toxic substances is divided by maufacturer, tradename, stock number, and distributor. This index provides a means of accessing information including hazards, uses, and chemical composition of materials stored and used at KSC's Biomedical Operations and Research Office.

Source record↗

Application of Ni-63 photo and corona discharge ionization for the analysis of chemical warfare agents and toxic wastes

Over the past decade, advances in instrumental design and refinements in the understanding of ion molecule reactions at atmospheric pressure enabled the application of Ion Mobility Spectrometry (IMS) as a simple inexpensive and sensitive analytical method for the detection of organic trace compounds. Positive and negative gas-phase ions for ion mobility spectrometry have been produced by a variety of methods, including photo-ionization, laser multi photon ionization, surface ionization, corona discharge ionization. The most common ion source used in ion mobility spectrometry is a radioactive Ni-63 foil which is favored due to simplicity, stability, convenience, and high selectivity. If reactant ions like (H2O(n)H)(+) or (H2O(n)O2)(-) dominate in the reaction region, nearly all kinds of compounds with a given proton or electron affinity; are ionized. However, the radioactivity of the Ni-63 foil is one disadvantage of this ion source that stimulates the development and application of other ionization techniques. In this paper, we report analyses of old chemical warfare agents and toxic wastes using Bruker RAID ion mobility spectrometers. Due to the modular construction of the measuring cell, the spectrometers can be equipped with different ion sources. The combined use of Ni-63, photo- and corona discharge ionization allows the identification of different classes of chemical compounds and yields in most cases comparable results.

Stach, J.↗