Search NASA⌕ Search

SEARCH · Search NASA

Results for “TPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Time Projection Chamber for High Accuracy and Precision Fission Cross-Section Measurements

The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross-section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4p acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross-sections and examine the associated systematic errors. This paper provides a detailed description of the design requirements, the design solutions, and the initial performance of the fissionTPC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

β-Octabromo- and β-Octakis(trifluoromethyl)isocorroles: New Sterically Constrained Macrocyclic Ligands

Here, we present a study of the acid-induced demetalation of two sterically hindered copper corroles, Cu β-octabromo-meso-triphenylcorrole (Cu[Br 8 TPC]) and β-octakis(trifluoromethyl)-meso-tris(p-methoxyphenyl)corrole (Cu[(CF 3 ) 8 TpOMePC]). Unlike reductive demetalation, which affords the free-base β-octabromocorrole, demetalation of Cu[Br 8 TPC] under non- reductive conditions (CHCl 3 /H 2 SO 4 ) resulted in moderate yields of free-base 5- and 10-hydroxy isocorroles. The isomeric free bases could be complexed to Co II and Ni II , affording stable complexes. Only reductive demetalation was found to work for Cu[(CF 3 ) 8 TpOMePC], affording a highly saddled, hydrated corrole, H 3 [5-OH,10-H-(CF 3 ) 8 TpOMePC], where the elements of water had added across C5 and C10. Interaction of this novel free base with Co II resulted in Co[iso-10-H-[CF 3 ) 8 TpOMePC], a Co II 10-hydro isocorrole. Finally, the new metal complexes were all characterized by single-crystal X-ray diffraction analysis and, despite their sterically hindered nature, were found to exhibit almost perfectly planar isocorrole cores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bioactivity Potentials of Biodegradable Chitosan/Gelatin Film Forming Solutions Combined with Monoterpenoid Compounds

Novel food packaging systems including biodegradable/edible films have been introduced to the market for consumers who desire natural products for their nutrition. Biochemically active plant compounds are added to the biopolymer-based films to improve their functionality. Within the present study, chitosan (1%) and gelatin (4%) biopolymer-based film forming solutions (FFSs) combined with 1, 2, 5 and 10% (v/v) eugenol, pulegone and carvacrol, monoterpenoid compounds, were evaluated for their antimicrobial and antioxidative potential. Antioxidant activities and total phenolic contents (TPC) of the FFSs were determined by 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical scavenging activity and Folin–Ciocalteau assays, respectively. Screening the antimicrobial activity of FFSs were performed against food spoilage microorganisms including Bacillus cereus, Escherichia coli, Salmonella typhimurium, Staphylococcus aureus and Listeria monocytogenes and a fungi, Candida albicans by using agar well diffusion method. The chitosan FFS containing 10% carvacrol had greater TPC (3857.3 ± 0.07 mg gallic acid equivalent/L). The highest antioxidative capacity was observed for the chitosan FFS containing 10% eugenol as 97.92 ± 0.01%. FFSs with monoterpenoids showed promising antimicrobial activities against tested microorganisms. Based on antioxidative and antimicrobial potentials of the FFSs, it can be envisaged to use monoterpenoid incorporation to biopolymer films for food packaging applications.

60 APPLIED LIFE SCIENCES↗

Absolute position measurement in a gas time projection chamber via transverse diffusion of drift charge

Time Projection Chambers (TPCs) with charge readout via micro pattern gaseous detectors can provide detailed measurements of charge density distributions. We here report on measurements of alpha particle tracks, using a TPC where the drift charge is amplified with Gas Electron Multipliers and detected with a pixel ASIC. We find that by measuring the 3-D topology of drift charge and fitting for its transverse diffusion, we obtain the absolute position of tracks in the drift direction. For example, we obtain a precision of 1~cm for 1~cm-long alpha track segments. To our knowledge this is the first demonstration of such a measurement in a gas TPC. This technique has several attractive features: it does not require knowledge of the initial specific ionization, is robust against bias from diffuse charge below detection threshold, and is also robust against high charge densities that saturate the detector response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Generic Electronics for Time Projection Chamber ($\mathrm{GET}$) readout system for heavy Radioactive isotope collision experiments

Here we have implemented the Generic Electronics for Time Projection Chamber (GET) in a SAMURAI Pion Reconstruction and Ion-Tracker (SπRIT) readout system for heavy radioactive ion collision experiments at RIKEN-RIBF. The SπRIT experiment is designed for heavy ion collision experiments with radioactive ion beams, where a Time Projection Chamber (TPC) with 12096 pixelized readout pads is employed as the main device. Since the TPC is located on the beam line, the readout electronics must handle small signals from pions as well as very large signals from beam or large fragment particles. Operation of the GET electronics during experiment functioned well using 270 time-bucket readout with 25 MHz sampling at an event Data acquisition (DAQ) rate of 60 Hz. Using the slope information of acquired signals it is possible to extend the dynamic range of dE/dx information compared to using the peak height information. However, huge signals arising from energetic δ-rays produced by un-interacted projectiles induce dead channels, which can be recovered after 70 μs on average.

47 OTHER INSTRUMENTATION↗

The Mini-CAPTAIN liquid argon time projection chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unsupervised learning for identifying events in active target experiments

This article presents novel applications of unsupervised machine learning methods to the problem of event separation in an active target detector, the Active-Target Time Projection Chamber (AT-TPC). The overarching goal is to group similar events in the early stages of the data analysis, thereby improving efficiency by limiting the computationally expensive processing of unnecessary events. The application of unsupervised clustering algorithms to the analysis of two-dimensional projections of particle tracks from a resonant proton scattering experiment on 46 Ar is introduced. We explore the performance of autoencoder neural networks and a pre-trained VGG16 Simonyan and Zisserman (2015) convolutional neural network. We study clustering performance on both data from a simulated 46 Ar experiment, and real events from the AT-TPC detector. We find that a -means algorithm applied to simulated data in the VGG16 latent space forms almost perfect clusters. Additionally, the VGG16+-means approach finds high purity clusters of proton events for real experimental data. Here, we also explore the application of clustering the latent space of autoencoder neural networks for event separation. While these networks show strong performance, they suffer from high variability in their results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of ion backflow using a quadruple GEM detector with various gas mixtures

In gaseous tracking detectors with a large gaseous volume, like Time Projection Chambers (TPC), multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. TPCs with multilayer GEM readout are used in the recently upgraded ALICE experiment, and in the upcoming sPHENIX experiment. In both cases, suppression of ion backflow (IBF) is important for achieving the desired detector performance. Here, we report on studies of effective gain, IBF, and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers. These studies are performed as baseline measurements intended to aid in the optimization of the operating conditions of the GEMs of the sPHENIX TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signatures of clustering accessible with a Time Projection Chamber: TexAT

Many experimental observables in clustering require high-sensitivity, almost background-free measurements. The use of Time Projection Chambers (TPCs) over the past 15 years have demonstrated their capability as a step change in the accessibility of many of these observables, as well as the possibility to study clustering via new techniques. A summary of the difficulties and pitfalls of determining the type of clustering from observables is briefly discussed, with a focus on α-condensation and the possibility of an additional (Efimov) 0 + state in 12 C, below the Hoyle state. The expansion of the technique used to tackle this challenge to study 3α + p clustering in 13 N is also discussed, highlighting the exciting opportunities TPCs provide to study clustering inaccessible by conventional means. Finally, an overview of the recent and upcoming advances in TPC technology is given as well as listing additional future challenges that are needed to be overcome, in the context of discussing the next-generation upgrade to the existing TexAT TPC, known as TeBAT (TExas Birmingham Active Target).

Bishop, Jack↗

Measurement of identified charged hadron spectra in proton-proton collisions using the Inner Tracking System of the ALICE experiment at the LHC

The measurement of the identified charged hadron p{sub t} spectra using the ITS energy loss signal in the pp data at {radical}(s) = 900 GeV collected by the ALICE experiment at LHC will be discussed. It is performed using the Inner Tracking System (ITS) in stand-alone mode, both for track reconstruction and particle identification, allowing one to detect low momentum particles with p{sub t} below 200 MeV/c. A second method using the tracks reconstructed by both the ITS and the Time Projection Chamber (TPC) has also been developed. The obtained results will be compared with the ones obtained from the TPC and from the Time Of Flight detector and used to extract the mean p{sub t} value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Present and Future of Central Production With STAR Detector at RHIC

The present status and future of the physics program of Central Production using the STAR detector at RHIC are described. The program focuses on particle production in the Double Pomeron Exchange (DPE) process. Forward protons from the DPE interaction are detected in the Roman Pot system installed at 55.5 m and 58.5 m on both sides of the STAR interaction point. The recoil system of charged particles from the DPE process is measured in the STAR Time Projection Chamber (TPC). The first data were taken during the 2009 RHIC Run 9 using polarized proton-proton collisions at {radical}(s) 200 GeV. The preliminary spectra of two pion and four pion invariant mass reconstructed by STAR TPC in central region of pseudo-rapidity |{eta}|<1, are presented. Plans to take data with the current system at {radical}(s) = 500 GeV and plans to upgrade the forward proton tagging system, so that it can reach higher masses and obtain large data samples to allow searching for glueballs that could be produced in the DPE process, are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiopurity control in the NEXT-100 double beta decay experiment

An extensive material screening and selection process is underway in the construction of the 'Neutrino Experiment with a Xenon TPC' (NEXT), intended to investigate neutrinoless double beta decay using a high-pressure xenon gas TPC filled with 100 kg of Xe enriched in {sup 136}Xe. Determination of the radiopurity levels of the materials is based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain) and also on Glow Discharge Mass Spectrometry. Materials to be used in the shielding, pressure vessel, electroluminescence and high voltage components and energy and tracking readout planes have been already taken into consideration. The measurements carried out are presented, describing the techniques and equipment used, and the results obtained are shown, discussing their implications for the NEXT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pattern recognition techniques to reduce backgrounds in the search for the {sup 136}Xe double beta decay with gaseous TPCs

The observation of the neutrinoless double beta decay may provide essential information on the nature of neutrinos. Among the current experimental approaches, a high pressure gaseous TPC is an attractive option for the search of double beta decay due to its good energy resolution and the detailed topological information of each event. We present in this talk a detailed study of the ionization topology of the {sup 136}Xe double beta decay events in a High Pressure Xenon TPC, as well as that of the typical competing backgrounds. We define some observables based on graph theory concepts to develop automated discrimination algorithms. Our criteria are able to reduce the background level by about three orders of magnitude in the region of interest of the {sup 136}Xe Q{sub ββ} for a signal acceptance of 40%. This result provides a quantitative assessment of the benefit of topological information offered by gaseous TPCs for double beta decay search, and proves that it is a promising feature in view of future experiments in the field. Possible ideas for further improvement in the discrimination algorithms and the dependency of these results with the gas diffusion and readout granularity will be also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme argon purity in a large, non-evacuated cryostat

Liquid Argon Time Projection Chambers (LArTPCs) show promise as scalable devices for the large detectors needed for long-baseline neutrino oscillation physics. Over the last several years at Fermilab a staged approach to developing the technology for large detectors has been developed. The TPC detectors require ultra-pure liquid argon with respect to electronegative contaminants such as oxygen and water. The tolerable electronegative contamination level may be as pure as 60 parts per trillion of oxygen. Three liquid argon cryostats operated at Fermilab have achieved the extreme purity required by TPCs. These three cryostats used evacuation to remove atmospheric contaminants as the first purification step prior to filling with liquid argon. Future physics experiments may require very large detectors with tens of kilotonnes of liquid argon mass. The capability to evacuate such large cryostats adds significant cost to the cryostat itself in addition to the cost of a large scale vacuum pumping system. This paper describes a 30 ton liquid argon cryostat at Fermilab which uses purging to remove atmospheric contaminants instead of evacuation as the first purification step. This cryostat has achieved electronegative contamination levels better than 60 parts per trillion of oxygen equivalent. The results of this liquid argon purity demonstration will strongly influence the design of future TPC cryostats.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon and material radiopurity assessment for the NEXT double beta decay experiment

The ”Neutrino Experiment with a Xenon TPC” (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in {sup 136}Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗