Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Projection Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Main Injector Particle Production Experiment (MIPP) at Fermilab

The Main Injector Particle Production Experiment at Fermilab uses particle beams of charged pions, kaons, proton and anti-proton with beam momenta of 5 to 90 GeV/c and thin targets spanning the periodic table from (liquid) hydrogen to uranium to measure particle production cross sections in a full acceptance spectrometer with charged particle identification for particles from 0.1 to 120 GeV/c using Time Projection Chamber, Time of Flight, multicell Cherenkov, and Ring Imaging Cherenkov detectors and Calorimeter for neutrons. Particle production using 120 GeV/c protons from Main Injector on the MINOS target was also measured. We describe the physics motivation to perform such cross section measurements and highlight the impact of hadronic interaction data on neutrino physics. Recent results on forward neutron cross sections and analysis of MINOS target data are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Main Injector Particle Production Experiment (MIPP) at Fermilab

The Main Injector Particle Production Experiment at Fermilab uses particle beams of charged pions, kaons, proton and anti-proton with beam momenta of 5 to 90 GeV/c and thin targets spanning the periodic table from (liquid) hydrogen to uranium to measure particle production cross sections in a full acceptance spectrometer with charged particle identification for particles from 0.1 to 120 GeV/c using Time Projection Chamber, Time of Flight, multicell Cherenkov, and Ring Imaging Cherenkov detectors and Calorimeter for neutrons. Particle production using 120 GeV/c protons from Main Injector on the MINOS target was also measured. We describe the physics motivation to perform such cross section measurements and highlight the impact of hadronic interaction data on neutrino physics. Recent results on forward neutron cross sections and analysis of MINOS target data are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developing Detectors for Scintillation Light in Liquid Argon for DUNE

The Deep Underground Neutrino experiment will conduct a broad program of physics research by studying a beam of neutrinos from Fermilab, atmospheric neutrinos, neutrinos from potential supernovae, and potential nucleon decay events. In pursuit of these studies, the experiment will deploy four 10kt fiducial mass liquid argon time projection chambers underground in Lead, South Dakota. Liquid argon time projection chambers allow high-resolution tracking and energy measurements. A precise timing signal is needed to provide the necessary time stamp to localize events in the drift direction. As liquid argon is a natural scintillator, a photon detection system will be deployed to provide such a signal, especially for non-beam events. In the baseline design for the single-phase time projection chamber, the detectors are contained within the anode plane assemblies. The design of two prototypes utilizing wavelength shifters and light guides are presented, and aspects of the research and development program are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and Technical Challenges of Liquid Argon Detectors

Liquid argon time projection chambers offer the possibility of incredible resolution of particle interactions. This review outlines the ongoing research and development towards the realization of a multi-kiloton scale detector. The ICARUS and ArgoNeuT experiments which make use of liquid argon time projection chamber technology are also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DUNE Near Detector

DUNE is a next-generation experiment aiming to provide precision measurements of neutrino oscillation parameters. It will detect neutrinos produced in the Long-Baseline Neutrino Facility beamline at Fermilab, using a Near Detector situated near the beam target where the neutrinos originate and a Far Detector located 1300 km away in South Dakota. A comparison of the spectra of neutrinos measured at the Far and the Near Detector will allow for the extraction of oscillation probabilities from which the oscillation parameters can be inferred. The specific role of the Near Detector is to serve as the experiment’s control: it will establish the no oscillation null hypothesis, measure and monitor the beam, constrain systematic uncertainties, and provide essential measurements of the neutrino interactions to improve models. The Near Detector complex will include three primary detector components: a liquid argon time projection chamber, a high-pressure gas time projection chamber and an on-axis beam monitor. The three detectors will serve important individual and overlapping functions, with two of them being also able to move transverse to the beam’s axis via the DUNE-PRISM program. The overall mission of the Near Detector, as well as the three sub-detectors’ unique capabilities and physics programs will be discussed in these proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results from the HMPID detector in the ALICE experiment at LHC

The ALICE experiment is dedicated to the study of heavy-ion collisions at LHC energies. ALICE has a high-quality hadron identification system in the central region e.g. a Inner Tracking System, a large Time-Projection-Chamber, a Time-Of-Flight and the High Momentum Particle Identification Detector (HMPID). The ALICE HMPID detector has been designed to identify charged hadrons ({rho}, K, p) in the momentum range 1<p<5 GeV/c. Despite its limited geometrical acceptance, less than 10% of the central ALICE barrel, the HMPID detector has successfully accumulated enough statistics during the first proton-proton runs at LHC, to allow the detector alignment and to evaluate the calibration parameters needed to estimate its performance. Preliminary HMPID results from p-p collisions at {radical}(s) = 7 TeV and its future contribution to the ALICE physics programme, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Multi-Purpose Detector for NICA heavy-Ion Collider at JINR

The Multi-Purpose Detector (MPD) is designed to study heavy-ion collisions at the Nuclotron-based heavy Ion Collider fAcility (NICA) at JINR, Dubna. Its main components located inside a superconducting solenoid are a tracking system composed of a silicon microstrip vertex detector followed by a large volume time-projection chamber, a time-of-flight system for particle identification and a barrel electromagnetic calorimeter. A zero degree hadron calorimeter is designed specifically to measure the energy of spectators. In this paper, all parts of the apparatus are described and their tracking and particle identification parameters are discussed in some detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Study of Particle Production in Proton Induced Collisions Using the MIPP Detector at Fermilab

The Main Injector Particle Production (MIPP) experiment is a fixed target hadron production experiment at Fermilab. MIPP is a high acceptance spectrometer which provides excellent charged particle identification using Time Projection Chamber (TPC), Time of Flight (ToF), multicell Cherenkov (Ckov), ring imaging Cherenkov (RICH) detectors, and Calorimeter for neutrons. The MIPP experiment is designed to measure particle production in interactions of 120 GeV/c primary protons from the Main Injector and secondary beams of $\pi^{\pm}, \rm{K}^{\pm}$, p and $\bar{\rm{p}}$ from 5 to 90 GeV/c on nuclear targets which include H, Be, C, Bi and U, and a dedicated run with the NuMI target. The goal of the experiment is to measure hadron production cross sections or yields using these beams and targets. These hadronic interaction data can have a direct impact on the detailed understanding of the neutrino fluxes of several accelerator-based neutrino experiments like MINOS, MINER$\nu$A, NO$\ nu$A and ELBNF. In this thesis, we present inelastic cross section measurements for 58 and 85 GeV/c p+p interactions, and 58 and 120 GeV/c p+Be, p+C and p+Bi interactions. A new method is described to account for the low multiplicity inefficiencies in the interaction trigger using KNO scaling. Inelastic cross sections as a function of multiplicity are also presented for p+H and p+C interactions at different beam momenta. The MIPP data are compared with the Monte Carlo predictions and existing data. We also describe an algorithm to identify charged particles ($\pi^{\pm}/\rm{p}/\bar{\rm{p}}$ etc.), and present the inclusive charged pion production cross sections in bins of true momentum using 58 and 120 GeV/c p+C interactions for both the data and Monte Carlo.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Burst Chasing X-ray Polarimeter

Gamma-ray bursts are one of the most powerful explosions in the universe and have been detected out to distances of almost 13 billion light years. The exact origin of these energetic explosions is still unknown but the resulting huge release of energy is thought to create a highly relativistic jet of material and a power-law distribution of electrons. There are several theories describing the origin of the prompt GRB emission that currently cannot be distinguished. Measurements of the linear polarization would provide unique and important constraints on the mechanisms thought to drive these powerful explosions. We present the design of a sensitive, and extremely versatile gamma-ray burst polarimeter. The instrument is a photoelectric polarimeter based on a time-projection chamber. The photoelectric time-projection technique combines high sensitivity with broad band-pass and is potentially the most powerful method between 2 and 100 keV where the photoelectric effect 1s the dominant interaction process We present measurements of polarized and unpolarized X-rays obtained with a prototype detector and describe the two mission concepts, the Gamma-Ray Burst Polarimeter (GRBP) for thc U S Naval Academy satellite MidSTAR-2, and thc Low Energy Polarimeter (LEP) onboard POET, a broadband polarimetry concept for a small explorer mission.

Hill, Joanne E.↗

A Burst Chasing X-ray Polarimeter

Tihs is a viewgraph presentation of a discussion of the X-ray Polarimeter. Gamma-ray bursts are one of the most powerful explosions in the universe and have been detected out to distances of almost 13 billion light years. The exact origin of these energetic explosions is still unknown but the resulting huge release of energy is thought to create a highly relativistic jet of material and a power-law distribution of electrons. There are several theories describing the origin of the prompt GRB emission that currently cannot be distinguished. Measurements of the linear polarization would provide unique and important constraints on the mechanisms thought to drive these powerful explosions. We present the design of a sensitive, and extremely versatile gamma-ray burst polarimeter. The instrument is a photoelectric polarimeter based on a time-projection chamber. The photoelectric time-projection technique combines high sensitivity with broad band-pass and is potentially the most powerful method between 2 and 100 keV where the photoelectric effect is the dominant interaction process We present measurements of polarized and unpolarized X-rays obtained with a prototype detector and describe the two mission concepts, the Gamma-Ray Burst Polarimeter (GRBP) for thc U S Naval Academy satellite MidSTAR-2, and thc Low Energy Polarimeter (LEP) onboard POET, a broadband polarimetry concept for a small explorer mission.

Hill, Joanne↗

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift dis tance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high and low-energy events. Using point-like energy deposits from 83m Kr calibration electron captures (E ~ 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias < 1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E ≥ 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q ββ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

Spurious-electron signals in dual-phase noble-liquid time projection chambers have been observed in both xenon and argon Time Projection Chambers (TPCs). This paper presents the first comprehensive study of spurious electrons in argon, using data collected by the DarkSide-50 experiment at the INFN Laboratori Nazionali del Gran Sasso (LNGS). Understanding these events is a key factor in improving the sensitivity of low-mass dark matter searches exploiting ionization signals in dual-phase noble liquid TPCs. We find that a significant fraction of spurious-electron events, ranging from 30 to 70% across the experiment's lifetime, are caused by electrons captured from impurities and later released with delays of order 5-50 ms. The rate of spurious-electron events is found to correlate with the operational condition of the purification system and the total event rate in the detector. Finally, we present evidence that multi-electron spurious electron events may originate from photo-ionization of the steel grid used to define the electric fields. These observations indicate the possibility of reduction of the background in future experiments and hint at possible spurious electron production mechanisms.

Agnes, P. [GSSI, Aquila; Gran Sasso]↗

Perspectives of a mid-rapidity dimuon program at the RHIC: a novel and compact muon telescope detector

We propose a large-area, cost-effective Muon Telescope Detector (MTD) at mid-rapidity for the Solenoidal Tracker at RHIC (STAR) and for the next generation of detectors at a possible electron-ion collider. We utilize large Multi-gap Resistive Plate Chambers with long readout strips (long-MRPC) in the detector design. The results from cosmic ray and beam tests show the intrinsic timing and spatial resolution for a long-MRPC are 60-70 ps and {approx} 1 cm, respectively. The performance of the prototype muon telescope detector at STAR indicates that muon identification at a transverse momentum of a few GeV/c can be achieved by combining information from track matching with the MTD, ionization energy loss in the Time Projection Chamber, and time-of-flight measurements. A primary muon over secondary muon ratio of better than 1/3 can be achieved. This provides a promising device for future quarkonium programs and primordial dilepton measurements at RHIC. Simulations of the muon efficiency, the signal-to-background ratio of J/{psi}, the separation of {Upsilon} 1S from 2S+3S states, and the electron-muon correlation from charm pair production in the RHIC environment are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of an Ionization Readout Tile for nEXO

Anewdesign for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3 mm wide, on a 10 cm 10 cm fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a 207Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution E=5.5% is observed at 570 keV, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936 V/cm.

Jewell, M J.↗

The Quantum Nature and Mass of the Neutrino. FY20 Annual Laboratory Continuation Progress Report

Over the last 100 years we have learned a much about the neutrino, but there remain interesting questions about this weakly interacting particle. In particular, at LLNL we are developing experiments to measure the mass and the quantum nature of the neutrino. The 2015 long range plan recommended tonne-scale neutrinoless double beta decay experiments as the top new project priority and this experiment will target the quantum nature of the neutrino. The LLNL team is motivated and focused on developing the best technology for this experiment which is a liquid xenon time project chamber called nEXO. On a longer time scale, LLNL is also developing technology to measure the neutrino mass with tritium decay experiments. Work on nEXO at LLNL started in 2015 with an LDRD and program development funds to develop the nEXO concept, publish sensitivity predictions, explore alternatives and risks, and to build a credible project team and this effort is on going. In addition, we received research funding from DOE-SC NP and LLNL manages pre-conceptual R&D for the nEXO collaboration a portion of which is executed at LLNL. The Project 8 effort is solely funded by LLNL LDRD, and ends this year. A second LDRD effort is focused on repurposing cyclotron radiation emission spectroscopy for eV-scale X-ray detection. This second effort, while separated from Project 8, still has scientific and technical commonalities with Project 8. The funding for this X-ray detection effort will continue for one more year. LLNL has a long history of building large projects, science projects and time projection chambers, but nEXO is in fact the first project of this scale that LLNL is prepared to lead for DOE-SC NP.We have the tools, skills, people and motivation to make nEXO a reality. The current program development dollars are used to prepare the nEXO concept for down select and CD1. These internal LLNL dollars pay for a number of things including project staff to organize the nEXO collaboration for the various reviews that lie ahead, to develop the draft plans and structure to manage the project as well as setting up an external advisory committee. The current LDRD is exploring alternatives that effect the risk profile as well as possible performance improvements. The DOE-SC NP base funding is targeted at simulation and analysis of the nEXO concept in preparation for the down select and refinement of the understanding of the detector as well as scientific effort on the large xenon test stand (LXTS) that will burn down one of the largest risks to the nEXO project. Lastly, LLNL is leading the pre-conceptual R&D effort and managing the funds for the nEXO collaboration. The results of this effort are reported elsewhere, but the scope of this executed at LLNL will be reported here and is primarily the engineering and construction of the LXTS experiment. The primary technical contribution of LLNL to the Project 8 concept is the formation and study of atomic tritium. Atomic tritium is necessary for Project 8 to reach the ultimate sensitivity. LLNL has considerable experience with tritium and is well suited for this crucial work. Although the focus of this work is strictly fundamental science, there has already been one significant spinoff to develop a new means to measure radio xenon in the air

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter directionality revisited with a high pressure xenon gas detector

An observation of the anisotropy of dark matter interactions in a direction-sensitive detector would provide decisive evidence for the discovery of galactic dark matter. Directional information would also provide a crucial input to understanding its distribution in the local Universe. Most of the existing directional dark matter detectors utilize particle tracking methods in a low-pressure gas time projection chamber. These low pressure detectors require excessively large volumes in order to be competitive in the search for physics beyond the current limit. In order to avoid these volume limitations, we consider a novel proposal, which exploits a columnar recombination effect in a high-pressure gas time projection chamber. The ratio of scintillation to ionization signals observed in the detector carries the angular information of the particle interactions. In this paper, we investigate the sensitivity of a future directional detector focused on the proposed high-pressure Xenon gas time projection chamber. We study the prospect of detecting an anisotropy in the dark matter velocity distribution. We find that tens of events are needed to exclude an isotropic distribution of dark matter interactions at 95% confidence level in the most optimistic case with head-to-tail information. However, one needs at least 10-20 times more events without head-to-tail information for light dark matter below ~50 GeV. For an intermediate mass range, we find it challenging to observe an anisotropy of the dark matter distribution. Our results also show that the directional information significantly improves precision measurements of dark matter mass and the elastic scattering cross section for a heavy dark matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Observation of the β3αp Decay of 13 O via β-Delayed Charged-Particle Spectroscopy

The β-delayed proton decay of 13 O has previously been studied, but the direct observation of β-delayed 3⁢α⁢p decay has not been reported. Rare 3⁢α⁢p events from the decay of excited states in 13 N* provide a sensitive probe of cluster configurations in 13 N*. To measure the low-energy products following β-delayed 3⁢αp decay, the Texas Active Target (TexAT) time projection chamber was employed using the one-at-a-time β-delayed charged-particle spectroscopy technique at the Cyclotron Institute, Texas A&M University. A total of 1.9 × 10 5 13 O implantations were made inside the TexAT time projection chamber. Furthermore, a total of 149 3⁢αp events were observed, yielding a β-delayed 3⁢αp branching ratio of 0.078(6)%. Four previously unknown α-decaying excited states were observed in 13 N at 11.3, 12.4, 13.1, and 13.7 MeV decaying via the 3⁢α + p channel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗