Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved X-ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Nanometer-Scale Acoustic Wave Packets Generated by Stochastic Core-Level Photoionization Events

We demonstrate that the absorption of femtosecond hard x-ray pulses excites quasispherical, high-amplitude, and high-wave-vector coherent acoustic phonon wave packets using an all hard-x-ray pump-probe scattering experiment. The time- and momentum-resolved diffuse scattering signal is consistent with an ensemble of 3D strain wave packets induced by the rapid electron cascade dynamics following photoionization at uncorrelated excitation centers. We quantify key parameters of this process, including the localization size of the stress field and the photon energy conversion efficiency into elastic energy. The parameters are determined by the photoelectron and Auger electron cascade dynamics, as well as the electron-phonon interaction. In particular, we obtain the localization size of the observed strain wave packet to be 1.5 and 2.5 nm for bulk SrTiO 3 and KTaO 3 single crystals, respectively. The results provide crucial information on the mechanism of x-ray energy deposition into matter and shed light on the shortest collective length scales accessible to coherent acoustic phonon generation using x-ray excitation. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Direct comparison of wire, foil, and hybrid X-pinches on a 200 kA, 150 ns current driver

Wire X-pinches (WXPs) have been studied comprehensively as fast (~1 ns pulse width), small (~1 μm) x-ray sources, created by twisting two or more fine wires into an “X” to produce a localized region of extreme magnetic pressure at the cross-point. Recently, two alternatives to the traditional WXP have arisen: the hybrid X-pinch (HXP), composed of two conical electrodes bridged by a thin wire or capillary, and the laser-cut foil X-pinch (LCXP), cut from a thin foil using a laser. We present a comparison of copper wire, hybrid, and laser-cut foil X-pinches on a single experimental platform: UC San Diego’s ~200 kA, 150 ns rise time GenASIS driver. All configurations produced 1–2 ns pulse width, ≤5 μm soft x-ray (Cu L-shell, ~1 keV) sources (resolutions diagnostically limited) with comparable fluxes. WXP results varied with linear mass and wire count, but consistently showed separate pinch and electron-beam-driven sources. LCXPs produced the brightest (~1 MW), smallest (≤5 μm) Cu K-shell sources, and spectroscopic data showed both H-like Cu K α lines indicative of source temperatures ≥2 keV, and cold K α (~8050 eV) characteristic of electron beam generated sources, which were not separately resolved on other diagnostics (within 1–2 ns and ≤200 μm). HXPs produced minimal K-shell emission and reliably single, bright, and small L-shell sources after modifications to shape the early current pulse through them. Benefits and drawbacks for each configuration are discussed to provide potential X-pinch users with the information required to choose the configuration best suited to their needs.

42 ENGINEERING↗

Combined multiplet theory and experiment for the Fe 2p and 3p XPS of FeO and Fe 2 O 3

The Al K alpha, 1486.6eV, based XPS of Fe 2p and Fe 3p for Fe(III) in Fe 2 O 3 and Fe(II) in FeO are compared with theoretical predictions based on ab initio wavefunctions that accurately treat the final, core-hole, multiplets. The principal objectives of this comparison are to understand the multiplet structure and to evaluate the use of both the 2p and 3p spectra in determining oxidation state. In order to properly interpret the features of these spectra and to use the XPS to provide atomistic insights as well as atomic composition, it is necessary to understand the origin of the multiplet energies and intensities. The theoretical treatment takes into account the ligand field and spin-orbit splittings, the covalent mixing of ligand and Fe 3d orbitals, and the angular momentum coupling of the open shell electrons. These effects lead to the distribution of XPS intensity into a large number of final, ionic, states that are only partly resolved with energies spread over a wide range of binding energies, BEs. For this reason, it is necessary to record the Fe 2p and 3p XPS spectra over a wide energy range which includes all the multiplets in the theoretical treatment as well as additional shake satellites. We also evaluate the effects of differing assumptions concerning the extrinsic background subtraction, to be sure our experimental spectrum may be fairly compared to the theory. In this work, we conclude that the Fe 3p XPS provides an additional means for distinguishing Fe(III) and Fe(II) oxidation states beyond just using the Fe 2p spectrum. In particular, with the use of the Fe 3p XPS, the depth of the material probed is about 1.5 times greater than for the Fe 2p XPS. In addition, a new type of atomic many-body effect that involves excitations into orbitals that have Fe f,$\ell$=3, symmetry has been shown to be important for the Fe 3p XPS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Reconciling the Different Apparent Decay Pathways for Iron(III) Tetraphenylporphyrin Chloride: Evidence for Excited State Branching

Detailed understanding of the photophysical properties of metalloporphyrins is key to rationally exploiting them in a variety of applications ranging from photocatalysis to opto-magnetics. Previous studies of the ferric-tetraphenylporphyrin chloride have provided contradictory descriptions of the excited state evolution. Optical transient-absorption suggested initial formation of a ππ* excited state, followed by ligand-to-metal charge-transfer (LMCT) from the porphyrin ring and then decay on the ∼2 ps time scale to a metal-centered excited state that had a lifetime of ∼15 ps. In contrast, femtosecond extreme ultraviolet transient-absorption at the Fe M 2,3 -edge, while agreeing on the initial formation of an LMCT state, found evidence that this decayed in ∼2 ps to the ground state. Here, we have used K-edge transient X-ray absorption and X-ray emission, together with time-resolved X-ray solution scattering to explore this system. Based on these data, we propose a new model, consistent with both the earlier and the current data, in which photoexcited FeTPPCl evolves through three different states on the LMCT manifold, with the ∼2 ps decay now seen to involve a branching between return to the ground state (∼70%) and formation of a long-lived LMCT state (∼30%).

Excited states↗

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

Experimental characterization of hot-electron emission and shock dynamics in the context of the shock ignition approach to inertial confinement fusion

We report on planar target experiments conducted on the OMEGA-EP laser facility performed in the context of the shock ignition (SI) approach to inertial confinement fusion. The experiment aimed at characterizing the propagation of strong shock in matter and the generation of hot electrons (HEs), with laser parameters relevant to SI (1-ns UV laser beams with I ~10 16 W/cm 2 ). Time-resolved radiographs of the propagating shock front were performed in order to study the hydrodynamic evolution. The hot-electron source was characterized in terms of Maxwellian temperature, T h , and laser to hot-electron energy conversion efficiency η using data from different x-ray spectrometers. The post-processing of these data gives a range of the possible values for T h and η [i.e., T h [keV] ϵ (20, 50) and η ϵ (2%, 13%)]. These values are used as input in hydrodynamic simulations to reproduce the results obtained in radiographs, thus constraining the range for the HE measurements. According to this procedure, we found that the laser converts ~10% ± 4% of energy into hot electrons with T h = 27 ± 8 keV. The paper shows how the coupling of different diagnostics and numerical tools is required to sufficiently constrain the problem, solving the large ambiguity coming from the post-processing of spectrometers data. The effect of the hot electrons on the shock dynamics is then discussed, showing an increase in the pressure around the shock front. Furthermore, the low temperature found in this experiment without pre-compression laser pulses could be advantageous for the SI scheme, but the high conversion efficiency may lead to an increase in the shell adiabat, with detrimental effects on the implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Epitaxial strain tuning of Er 3+ in ferroelectric thin films

Er 3+ color centers are promising candidates for quantum science and technology due to their long electron and nuclear spin coherence times, as well as their desirable emission wavelength. By selecting host materials with suitable, controllable properties, we introduce new parameters that can be used to tailor the Er 3+ emission spectrum. PbTiO 3 is a well-studied ferroelectric material with known methods of engineering different domain configurations through epitaxial strain. By distorting the structure of Er 3+ -doped PbTiO 3 thin films, we can manipulate the crystal fields around the Er 3+ dopant. This is resolved through changes in the Er 3+ resonant fluorescence spectra, tying the optical properties of the defect directly to the domain configurations of the ferroelectic matrix. Additionally, we are able to resolve a second set of peaks for films with in-plane ferroelectric polarization. We hypothesize these results to be due to either the Er 3+ substituting different sites of the PbTiO 3 crystal, differences in charges between the Er 3+ dopant and the original substituent ion, or selection rules. Systematically studying the relationship between the Er 3+ emission and the epitaxial strain of the ferroelectric matrix lays the pathway for future optical studies of spin manipulation by altering ferroelectric order parameters.

36 MATERIALS SCIENCE↗

Electron–Ion Covariance Reveals Geometry-Resolved Inner-Shell Spectra in CS 2 Photodissociation

The chemical shifts of inner-shell atomic orbitals are highly sensitive to chemical bonding and molecular structure. In evolving systems, however, the spectra of distinct molecular species and geometries overlap, obscuring the underlying chemical dynamics. Here we demonstrate the use of electron–ion covariance analysis to combine the structural sensitivity of Coulomb explosion imaging with inner-shell spectroscopy, yielding geometry-specific spectra of transient and product species. We apply this approach to the excited state dynamics of CS 2 probed by ionization above the S 2p edge. Electron–ion covariance with time- and momentum-selected S + and S 2+ ions isolates distinct S 2p photoelectron spectra for ground-state CS 2 , bent photoexcited CS 2 , the CS photoproduct, and bare atomic sulfur ─ species whose spectra overlap strongly in the channel-averaged measurement. Clear chemical shifts are observed in the covariance photoelectron spectrum for each of these species, all of which are consistent with high-level calculations. Here, by extracting the atomic S contribution to the photoelectron spectrum in a finely time-resolved manner we can disentangle this contribution to the overall time-resolved photoelectron spectrum as the photodissociation proceeds. These results demonstrate the promise of electron–ion covariance as a general approach to geometry-resolved inner-shell spectroscopy, opening a route to tracking structural evolution through chemical shifts in complex photoexcited molecules.

Ionization↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Electrolyte Vapor Induced Passivation and Transition Metal Redox on Electrode Active Materials

The gaseous environment that battery electrodes are exposed to is critical to their electrochemical performance, and yet, the impact of vapor-phase components in the glovebox is relatively unexplored. In this study, we examine how the surface of Li 4 Ti 5 O 12 and LiFePO 4 composite electrodes evolve upon exposure to 1 M LiPF 6 in ethylene carbonate:dimethyl carbonate electrolyte vapors in an argon-filled glovebox. Spatially resolved X-ray photoemission electron microscopy and X-ray photoelectron spectroscopy reveal that even brief (15 minutes) contact with electrolyte vapor initiates the formation of a LiF film and changes the oxidation state of transition metals at the particle surface. Notably, these modifications occur selectively on active material particles and not on binder or conductive carbon, underscoring the specificity of vapor-induced reactions. Prolonged exposure to electrolyte vapor over the course of 1 week yields thicker, more chemically complex interphases containing both LiF and lithium oxyfluorophosphate species (Li x PO y F z ). Subsequent electrochemical testing shows that vapor-induced passivation layers influence first cycle capacities, lithium (de)insertion overpotentials, and charge-transfer resistance values. In conclusion, these results indicate that vapor–electrode interactions may be a source of variability in electrochemical behavior over time and suggest that other, more reactive electrode materials may also be susceptible to interactions with electrolyte vapor.

36 MATERIALS SCIENCE↗

High-Temperature 2D Optical Relaxation Visualizes Enhanced Oxygen Exchange Kinetics at Metal-Mixed Conducting Oxide Interfaces

Solid-state heterointerfaces are of interest for emergent local behavior that is distinct from either bulk parent compound. One technologically relevant example is the case of mixed ionic/electronic conductor (MIEC)–metal interfaces, which play an important role in electrochemistry. Metal–MIEC composite electrodes can demonstrate improved catalytic activity vs single-phase MIECs, improving fuel cell efficiency. Similarly, MIEC surface reaction kinetics are often evaluated using techniques that place metal current collectors in contact with the surface under evaluation, potentially altering the response vs the native surface. Here, techniques enabling direct and local in situ observation of the behavior at and around such heterointerfaces are needed. Here, we develop a spatially resolved optical transmission relaxation (2D-OTR) method providing continuous evaluation of local, high-temperature, controlled atmosphere defect kinetics across a ~1 cm2 sample area simultaneously in a contact-free manner. We apply it to observe the spatial variance of oxygen incorporation and evolution rates at ~525–620 °C, in response to step changes in oxygen partial pressure, on MIEC SrTi 0.65 Fe 0.35 O 3–x films as a function of distance from porous Pt and Au layers. Using this model geometry, we find significant enhancements in kinetics adjacent to the metals that decay over a few millimeter distance. To extract kinetic parameters, we fit the short-term optical data (initial portion of relaxations) with an exponential decay function appropriate for surface-exchange-limited kinetics, yielding apparent surface exchange coefficients (k chem ) with spatial resolution, decreasing with distance from the metal. To understand the kinetic processes governing the complete (long-term) optical relaxations, we performed COMSOL simulations, which demonstrated that a combination of laterally varying k chem and in-plane diffusion controls the observed kinetics over the full time range. Further support for spatially varying kchem comes from demonstrations of changing surface and bulk chemistry vs distance from the metal–MIEC interface, by X-ray photoelectron and optical absorption spectroscopies, respectively. Although microporous Pt and Au are not excellent electrodes in isolation, both metals exert a synergistic effect on the oxygen surface exchange rate in the presence of the mixed conducting film.

36 MATERIALS SCIENCE↗

Dioxygen Activation Kinetics over Distinct Cu Site Types in Cu-Chabazite Zeolites

Cu-exchanged zeolites activate dioxygen to form active sites for partial methane oxidation (PMO), nitrogen oxide decomposition, and carbon monoxide oxidation. Apparent rates of O 2 activation depend both on the intrinsic kinetics of distinct Cu site types and the distributions of such sites within a given zeolite, which depend on the density and arrangement of the framework Al atoms. In this work, we use hydrothermal synthesis methods to control the arrangement of framework Al sites in chabazite (CHA) zeolites and, in turn, the distinct Cu site types formed. Time-resolved in situ Raman spectroscopy reveals the kinetics of O 2 adsorption and activation within these well-defined Cu-CHA materials and the concomitant structural evolution of copper–oxygen (Cu x O y ) complexes, which are interpreted alongside Cu(I) oxidation kinetics extracted from in situ X-ray absorption spectroscopy (XAS). Raman spectra of several plausible Cu x O y species simulated using density functional theory suggest that experimental spectra (λ ex = 532 nm) capture the formation of mono(μ-oxo)dicopper species (ZCuOCuZ). Transient experiments show that the timescales required to form Cu x O y structures that no longer change in Raman spectra correspond to the durations of oxidative treatments that maximize CH 3 OH yields in stoichiometric PMO cycles (approximately 2 h). Yet, these periods extend well beyond the timescales for the complete conversion of the initial Cu(I) intermediates to their Cu(II) states (<0.3 h, reflected in X-ray absorption near edge spectroscopy spectra), which demonstrates that Cu x O y complexes continue to evolve structurally following rapid Cu(I) oxidation. The dependence of ZCuOCuZ formation rates on O 2 pressure, H 2 O pressure, and temperature is consistent with a mechanism in which ZCuOH reduces to form ZCu + sites that bind molecular oxygen and form ZCu-O 2 intermediates. Subsequent reaction with proximate ZCu + forms bridging peroxo dicopper complexes that cleave O–O bonds to form ZCuOCuZ in steps facilitated by water. These data and interpretations provide evidence for the chemical processes that link rapid and kinetically irrelevant Cu oxidation steps (frequently probed by XAS and UV–vis spectroscopy) to the relatively slow genesis of reactive Cu complexes that form CH 3 OH during PMO. In doing so, we reveal previously unrecognized complexities in the processes by which Cu ions in zeolites activate O 2 to form active Cu x O y complexes, which underscore the insight afforded by judicious combinations of experimental and theoretical techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of Energy-Resolved γ-Ray Detection at Room Temperature by the CsPbCl 3 Perovskite Semiconductor

The detection of gamma-rays at room temperature with high-energy resolution using semiconductors is one of the most challenging applications. The presence of even the smallest amount of defects is sufficient to kill the signal generated from gamma-rays which makes the availability of semiconductors detectors a rarity. Lead halide perovskite semiconductors exhibit unusually high defect tolerance leading to outstanding and unique optoelectronic properties and are poised to strongly impact applications in photoelectric conversion/detection. Here we demonstrate for the first time that large size single crystals of the all-inorganic perovskite CsPbCl 3 semiconductor can function as a high-performance detector for gamma-ray nuclear radiation at room temperature. CsPbCl 3 is a wide-gap semiconductor with a bandgap of 3.03 eV and possesses a high effective atomic number of 69.8. We identified the two distinct phase transitions in CsPbCl 3 , from cubic (Pm-3m) to tetragonal (P4/mbm) at 325 K and finally to orthorhombic (Pbnm) at 316 K. Despite crystal twinning induced by phase transitions, CsPbCl 3 crystals in detector grade can be obtained with high electrical resistivity of similar to 1.7 X 10 9 Ω∙cm. The crystals were grown from the melt with volume over several cubic centimeters and have a low thermal conductivity of 0.6 W m -1 K -1 . The mobilities for electron and hole carriers were determined to similar to 30 cm 2 /(V s). Using photoemission yield spectroscopy in air (PYSA), we determined the valence band maximum at 5.66 +/- 0.05 eV. Under gamma-ray exposure, our Schottky-type planar CsPbCl 3 detector achieved an excellent energy resolution (similar to 16% at 122 keV) accompanied by a high figure-of-merit hole mobility-lifetime product (3.2 x 10 -4 cm 2 /V) and a long hole lifetime (16 mu s). The results demonstrate considerable defect tolerance of CsPbCl 3 and suggest its strong potential for gamma-radiation and X-ray detection at room temperature and above.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens

The performance of time-resolved photoemission experiments at fs-pulsed photon sources is ultimately limited by the e–e Coulomb interaction, downgrading energy and momentum resolution. Here, we present an approach to effectively suppress space-charge artifacts in momentum microscopes and photoemission microscopes. A retarding electrostatic field generated by a special objective lens repels slow electrons, retaining the k-image of the fast photoelectrons. The suppression of space-charge effects scales with the ratio of the photoelectron velocities of fast and slow electrons. Fields in the range from -20 to 01100 V/mm for E kin = 100 eV to 4 keV direct secondaries and pump-induced slow electrons back to the sample surface. Ray tracing simulations reveal that this happens within the first 40 to 3 μm above the sample surface for E kin = 100 eV to 4 keV. An optimized front-lens design allows switching between the conventional accelerating and the new retarding mode. Time-resolved experiments at E kin = 107 eV using fs extreme ultraviolet probe pulses from the free-electron laser FLASH reveal that the width of the Fermi edge increases by just 30 meV at an incident pump fluence of 22 mJ/cm2 (retarding field -21 V/mm). For an accelerating field of +2 kV/mm and a pump fluence of only 5 mJ/cm 2 , it increases by 0.5 eV (pump wavelength 1030 nm). At the given conditions, the suppression mode permits increasing the slow-electron yield by three to four orders of magnitude. The feasibility of the method at high energies is demonstrated without a pump beam at E kin = 3830 eV using hard x rays from the storage ring PETRA III. The approach opens up a previously inaccessible regime of pump fluences for photoemission experiments.

47 OTHER INSTRUMENTATION↗

Angularly resolved spectral reconstruction of x rays via filter pack attenuation

We have designed a new filter pack array to measure angular variations in x-ray spectra during a single shot. The filter pack was composed of repeating identical columns of aluminum and copper filters of varying thicknesses. These columns were located at different positions to measure the spectrum at each corresponding angle. This array was utilized in an experiment to measure the energy evolution of betatron x rays in a laser wakefield accelerator by curving the wakefield with a transverse density gradient, streaking the x rays across the array in front of an x-ray charge-coupled device (CCD) camera. After subtracting the background and “flattening” the image to remove spatial nonuniformities, a critical energy was calculated for each position that produced the best agreement with the measured signal. There was a clear change in critical energy with angle, shedding light on the dynamics of the electrons that traveled through the accelerator. Furthermore, these angles correspond to distinct emission times, covering a timescale of tens of picoseconds. The filter pack was capable of recovering these angular details without the impact of errors introduced by shot-to-shot variability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Across-Depth Heterogeneity and Irreversibility of Fast-Charge-Driven Lithium Plating

Enabling fast charging in lithium-ion batteries (LIBs) is a key factor for resolving consumers’ “range anxiety” concerns in choosing an electric vehicle over a gasoline-powered one. The best-known issue in the fast charging of current LIBs (based on LiNi x Mn y Co 1–x–y O 2 /graphite) is lithium plating, which is barely reversible and is accompanied by capacity loss over time. Therefore, understanding the reasons for the irreversibility of lithium plating driven by fast charging is critical to enhancing the fast-charging capability of LIBs. Here, a study of the irreversibility and heterogeneity of lithium plating is carried out by using electrochemical analyses, inductively coupled plasma mass spectroscopy, and X-ray photoelectron spectroscopy. Further, the study shows that the majority of the lithium plated during fast charging remains inactive even with very slow discharging rates, implying that most of the plated lithium is irreversibly lost. The study also reveals that chemical compounds such as LiF, Li 2 O and Li 2 (CO 3 ) are formed heterogeneously within the lithium plating and are responsible for some of the irreversibility of the plated lithium.

33 ADVANCED PROPULSION SYSTEMS↗