Search NASA⌕ Search

SEARCH · Search NASA

Results for “Timing resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

High-Speed PLIF Imaging of Hypersonic Transition over Discrete Cylindrical Roughness

In two separate test entries, advanced laser-based instrumentation has been developed and applied to visualize the hypersonic flow over cylindrical protrusions on a flat plate. Upstream of these trips, trace quantities of nitric oxide (NO) were seeded into the boundary layer. The protuberances were sized to force laminar-to-turbulent boundary layer transition. In the first test, a 10-Hz nitric oxide planar laser-induced fluorescence (NO PLIF) flow visualization system was used to provide wide-field-of-view, high-resolution images of the flowfield. The images had sub-microsecond time resolution. However these images, obtained with a time separation of 0.1 sec, were uncorrelated with each other. Fluorescent oil-flow visualizations were also obtained during this test. In the second experiment, a laser and camera system capable of acquiring NO PLIF measurements at 1 million frames per second (1 MHz) was used. This system had lower spatial resolution, and a smaller field of view, but the images were time correlated so that the development of the flow structures could be observed in time.

Danehy, P. M.↗

The annual cycle of satellite-derived sea surface temperature in the southwestern Atlantic Ocean

The annual cycle of sea surface temperature (SST) in the southwestern Atlantic Ocean was estimated using four years (July 1984-July 1988) of NOAA Advanced Very High Resolution Radiometer observations. High resolution satellite observations at 1-km space and daily time resolution were grided at 100-km space and 5-day time intervals to develop an analysis dataset for determination of low frequency SST variability. The integral time scale, a measure of serial correlation, was found to vary from 40 to 60 days in the domain of interest. The existence of superannual trends in the SST data was investigated, but conclusive results could not be obtained. The annual cycle (and, in particular, the annual harmonic) explains a large proportion of the SST variability. The estimated amplitude of the cycle ranges between 5 deg and 13 deg C throughout the study area, with minima in August-September and maxima in February. The resultant climatology is compared with an arbitrary 5-day satellite SST field, and with the COADS/ICE SST climatology. It was found that the higher resolution satellite-based SST climatology resolves boundary current structure and has significantly better structural agreement with the observed field.

Podesta, Guillermo P.↗

Impurity-enhanced core valence luminescence via Zn-doping in cesium magnesium chlorides

Scintillators with faster timing capabilities are currently in high demand for use in radiation detection systems in the fields of nuclear and medical physics. The limited number of suitable materials that meet the performance criteria of next generation detection systems presents an opportunity for discovery of new fast scintillator materials. In this work, the effects of doping several ultrafast core-valence luminescent (CVL) scintillators with divalent Zn is explored. Three compounds are investigated – CsMgCl 3 , Cs 2 MgCl 4 , and Cs 3 MgCl 5 – and single crystals of each doped with 5 mol% Zn are grown via the Bridgman method. Additionally, mixing across the full range of concentrations (from 0 % to 100 % Zn) is explored in the Cs 2 Mg 1-x Zn x Cl 4 and Cs 3 Mg 1-x Zn x Cl 5 systems. For low concentrations of Zn, light yields of all three compounds are enhanced (by up to ~60 %) compared to the pure crystals, achieving what we believe to be the brightest known CVL, CsMgCl 3 :Zn 5 % (3400 ± 170 ph/MeV light yield). More importantly, Zn doping does not affect the ultrafast timing properties, with each composition maintaining a single-component decay time around 1–3 ns. A sub-100 ps coincidence time resolution (CTR) is also achieved with CsMgCl 3 :Zn 5 %. The results of this work reveal a new avenue towards obtaining brighter CVL materials, which could open up possibilities for more advanced ultrafast scintillators to be discovered moving forward.

36 MATERIALS SCIENCE↗

A Geostationary Instrument Simulator for Aerosol Observing System Simulation Experiments

In the near future, there will be several new instruments measuring atmospheric composition from geostationary orbit over North America, East Asia, and Europe. This constellation of satellites will provide high resolution, time resolved measurements of trace gases and aerosols for monitoring air quality and tracking pollution sources. This paper describes a detailed, fast, and accurate (less than 1.0% uncertainty) method for calculating synthetic top of the atmosphere (TOA) radiances from a global simulation with a mesoscale free running model, the GEOS-5 Nature Run, for remote sensing instruments in geostationary orbit that measure in the ultraviolet-visible spectral range (UV-Vis). Generating these synthetic observations is the first step of an Observing System Simulation Experiment (OSSE), a framework for evaluating the impact of a new observation or algorithm. This paper provides details of the model sampling, aerosol and cloud optical properties, surface reflectance modeling, Rayleigh scattering calculations, and a discussion of the uncertainties of the simulated TOA radiance. An application for the simulated TOA radiance observations is demonstrated in the manuscript. Simulated TEMPO (Tropospheric Emissions: Monitoring of Pollution) and GOES-R (Geostationary Operational Environmental Satellites) observations were used to show how observations from the two instruments could be combined to facilitate aerosol type discrimination. The results demonstrate the viability of a detailed instrument simulator for radiance measurements in the UV-Vis that is capable of accurately simulating high resolution, time-resolved measurements with reasonable computational efficiency.

Castellanos, Patricia↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

XIPE the X-Ray Imaging Polarimetry Explorer

X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017. The proposal was, unfortunately, not selected. To be compliant with this schedule, we designed the payload mostly with existing items. The XIPE proposal takes advantage of the completed phase A of POLARIX for an ASI small mission program that was cancelled, but is different in many aspects: the detectors, the presence of a solar flare polarimeter and photometer and the use of a light platform derived by a mass production for a cluster of satellites. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus. Two additional GPDs filled with a 3-bar Ar-DME mixture always face the Sun to detect polarization from solar flares. The Minimum Detectable Polarization of a 1 mCrab source reaches 14 in the 210 keV band in 105 s for pointed observations, and 0.6 for an X10 class solar flare in the 1535 keV energy band. The imaging capability is 24 arcsec Half Energy Width (HEW) in a Field of View of 14.7 arcmin 14.7 arcmin. The spectral resolution is 20 at 6 keV and the time resolution is 8 s. The imaging capabilities of the JET-X optics and of the GPD have been demonstrated by a recent calibration campaign at PANTER X-ray test facility of the Max-Planck-Institut fr extraterrestrische Physik (MPE, Germany). XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil). The data policy is organized with a Core Program that comprises three months of Science Verification Phase and 25 of net observing time in the following 2 years. A competitive Guest Observer program covers the remaining 75 of the net observing time.

Astronomy X-ray Polarimetry↗

Observations of potential ultra high energy gamma-ray sources above 10(15) eV

The Haverah Park 50 m water-Cerenkov array has been used to examine a number of periodic sources for ultra high energy gamma-ray emission above 10 to the 15th power eV. The data, recorded between 1 Jan. 1979 and 31 Dec. 1984, feature a modest angular resolution of approx 3 deg with millisecond arrival time resolution post 1982. The sources investigated include the Crab pulsar, Her X-1, Au0115 + 63 and Geminga. All objects have been detected by workers in the TeV region, with varying degrees of confidence.

Lambert, A.↗

Holocinematographic Velocimeter

Holographic movies used to study turbulent flows. High-speed movie composed of single-exposure holograms of tracer particles in each of two simultaneous orthogonal views of flow. Time resolution set by movie frame rate, and total time limited by length of movie. Data from system used to verify results of theoretical models and numerical simulations of turbulence, visualize and measure coherent structures in "non-simple" turbulent flows, to examine mechanisms operative in various turbulence-control/drag-reduction concepts.

Weinstein, Leonard M.↗

Peeking through the picket fence - What astrophysical surprises may be present in the 100-200 A region?

In anticipation of more sensitive EUV and FUV spectroscopic instruments, spectra are simulated including interstellar absorption of solarlike, RS CVn, and flare stars as folded through the instrument parameters of the EUVE, Lyman/FUSE Phase A, and a desirable next-generation spectrometer. Even the relatively insensitive EUVE spectrometer is able to detect sufficient spectral lines from many active binary and dMe stars to determine their coronal-emission-measure distributions. The Lyman/FUSE or next-generation spectrometers are needed to study solar-type stars or flaring stars with high time resolution. The high throughput and effective area of a nex-generation spectrometer is needed for Doppler imaging studies, stellar wind and downflow measurements, and high time and spectral resolution of stellar flares.

Linsky, Jeffrey L.↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

Space and time variations of the solar Na D line profiles.

Preliminary results are presented of observations of the solar Na D lines obtained with high space and time resolution. The line profiles vary strongly with space and time implying that time averaging over a long period and large area will not produce the 'true' profile. The centre-limb increase in apparent Doppler width in the D lines is intrinsic. It is not due to space or time averaging. The amplitude of the 300-sec oscillation may range up to 1.5 km/sec in the region of formation of the D lines. The variation of the D line profile caused by the 300-sec oscillation may be described as follows: (1) the core is raised and lowered without change of shape, and (2) the wings broaden as the central intensity rises and narrow as it falls. Doppler width values derived from pairs of D line profiles are strongly correlated with the motion of the element observed. Indications of running waves have been found in the time variation of the core line bisectors.

Slaughter, C. D.↗

The M.I.T. Blowdown compressor facility

A blowdown compressor test facility has been developed which allows time-resolved aerodynamic testing of full-scale transonic compressor rotors at low cost. The rotor is brought to speed in vacuum, a diaphragm is opened, and the test gas is allowed to flow for a time of the order of 0.1 sec, during which the rotor is driven by its own inertia. Both 'steady-state' performance evaluation and detailed time resolution of the flow on the blade-passing time scale have been demonstrated for a two-ft-diam transonic rotor with a tangential Mach number of 1.2 and a nominal pressure ratio of 1.6. The steady-state performance as determined in the experiments includes an efficiency of 0.92 and a pressure ratio of 1.55 at design speed. The time-resolved measurements include the combination tone structure in the upstream flow field, resolved both axially and radially, and the wake structure downstream of the rotor, also resolved both radially and axially.

Kerrebrock, J. L.↗

JPL self pulsed laser surface measurement system development

The use of a self pulsed laser system for accurately describing the surface shape of large space deployed antenna structures was evaluated. Tests with a breadboard system verified functional operation with short time resolution on the order of .2 mm, nonambiguous ranging, and a maximum range capability on the order of 150 m. The projected capability of the system is resolution of less than .1 mm over a reasonable time period and a range extension to over 300 m.

Berdahl, M.↗

Fine time structure in the 1979 March 5 gamma ray burst

Data on the impulsive phase of the 1979 March 5 gamma ray burst, taken by three identical detectors aboard the Prognoz 7, Venera 11, and Venera 12 spacecraft with 2 ms time resolution, are presented. The first 200 ms of the time history may be described by an exponential decay with time constant of approximately 120 ms up to approximately 100 ms, and time constant of approximately 30 ms thereafter; at low energies, a pulsating component with a period of approximately 23 ms appears. The data could be consistent with torsional vibrations of a neutron star, the rotation of a rapidly spinning neutron star, or oscillations caused by interactions between hot plasma and a magnetic field.

Barat, C.↗

The observation of possible reconnection events in the boundary changes of solar coronal holes

Coronal holes are large scale regions of magnetically open fields which are easily observed in solar soft X-ray images. The boundaries of coronal holes are separatrices between large-scale regions of open and closed magnetic fields where one might expect to observe evidence of solar magnetic reconnection. Previous studies by Nolte and colleagues using Skylab X-ray images established that large-scale (more than 90,000 km) changes in coronal hole boundaries were due to coronal processes, i.e., magnetic reconnection, rather than to photospheric motions. Those studies were limited to time scales of about one day, and no conclusion could be drawn about the size and time scales of the reconnection process at hole boundaries. Sequences of approximate Skylab X-ray images with a time resolution of about 90 min are here used during times of the central meridian passages of the coronal hole labelled 'Coronal Hole 1' to search for hole-boundary changes which can yield the spatial and temporal scales of coronal magnetic reconnection. It is found that 29 of 32 observed boundary changes could be associated with bright points. The appearance of the bright point may be the signature of reconnection between small-scale and large-scale magnetic fields. The observed boundary changes contributed to the quasi-rigid rotation of Coronal Hole 1.

Kahler, S. W.↗

X-Ray Optics: Past, Present, and Future

X-ray astronomy started with a small collimated proportional counter atop a rocket in the early 1960s. It was immediately recognized that focusing X-ray optics would drastically improve both source location accuracy and source detection sensitivity. In the past 5 decades, X-ray astronomy has made significant strides in achieving better angular resolution, large photon collection area, and better spectral and timing resolutions, culminating in the three currently operating X-ray observatories: Chandra, XMM/Newton, and Suzaku. In this talk I will give a brief history of X-ray optics, concentrating on the characteristics of the optics of these three observatories. Then I will discuss current X-ray mirror technologies being developed in several institutions. I will end with a discussion of the optics for the International X-ray Observatory that I have been developing at Goddard Space Flight Center.

Zhang, William W.↗

An Investigation into the Elementary Temporal Structure of Solar Flare Hard X-Ray Bursts Using BATSE

The research performed under this contract is part of an on-going investigation to explore the finest time-resolution hard X-ray data available on solar flares. Since 1991, the Burst and Transient Source Experiment (BATSE) aboard the Compton Gamma Ray Observatory has provided almost continual monitoring of the Sun in the hard X-ray and gamma-ray region of the spectrum. BATSE provides for the first time a temporal resolution in the data comparable to the timescales on which flare particle energization occurs. Under this contract, we have employed an important but under-utilized BATSE data type, the Time-To-Spill (TTS) data, to address the question of how fine a temporal structure exists in flare hard X-ray emission. By establishing the extent to which "energy release fragments," or characteristic (recurrent) time structures, are building blocks of flare emission, it is possible to place constraints on particle acceleration theories. We have utilized a spectral estimation technique, known as Lomb's normalized periodogram, to overcome the challenge of computing the power spectra of the unevenly sampled TTS data. By comparing the flare's power spectra to the expected power arising from Poisson noise, we obtain measurements of the smallest, statistically significant timescales present in the data. We have found, in an initial sample of 100 flares, that the smallest statistically significant timescales detected in a single flare are: 89 ms (30 May 1991 11:26:06) in channel 0, 117 ms (17 May 1991 09:03:20) in channel 1, 167 ms (31 May 1991 16:53:12) in channel 2, and 1.55 s (06 June 1991 01:02:08) in channel 3. We have also found some evidence for the existence of preferred timescales, however, the significance of this finding awaits a larger sample of flares.

Newton , Elizabeth↗

An Investigation into the Elementary Temporal Structure of Solar Flare Hard X-Ray Bursts Using BATSE

The research performed under this contract is part of an on-going investigation to explore the finest time-resolution hard X-ray data available on solar flares. Since 1991, the Burst and Transient Source Experiment (BATSE) aboard the Compton Gamma Ray Observatory has provided almost continual monitoring of the Sun in the hard X-ray and gamma-ray region of the spectrum. BATSE provides for the first time a temporal resolution in the data comparable to the timescales on which flare particle energization occurs. Under this contract, we have employed an important but under-utilized BATSE data type, the Time-To-Spill (TTS) data, to address the question of how fine a temporal structure exists in flare hard X-ray emission. By establishing the extent to which 'energy release fragments,' or characteristic (recurrent) time structures, are building blocks of flare emission, it is possible to place constraints on particle acceleration theories.

Newton, Elizabeth↗