Search NASA⌕ Search

SEARCH · Search NASA

Results for “Timing spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Raman Spectroscopy Based On-Line, Real-Time Monitoring to Reduce Composition Uncertainties: Enhanced sensitivity through optimization of Raman Parameters

Optical spectroscopy-based on-line monitoring of Hanford processing streams can enable real-time characterization of chemical composition of process streams and batches, ultimately enabling and enhancing process control. It can provide immediate feedback on process conditions and has the potential to reduce the needed number of grab sample collections, thereby reducing times and costs associated with laboratory processing. Here we discuss the utilization of Raman spectroscopy to quantify multiple target analytes that are common within Hanford tanks and waste processing streams. Analytes include: nitrate, nitrite, carbonate, chromate, sulfate, phosphate, hydroxide, oxalate, ammonia, and aluminate. Most notably in this work, Raman applications to low-concentration streams are explored and optimized. Raman instrument specifications are compared; specifically, the impact of utilizing three different Raman excitation wavelengths, 405, 532, and 671 nm, is discussed. Also, Raman data collection parameters such as collection time and spectral averaging are measured and discussed. Finally, optical libraries of chemical targets were collected using optimized collection parameters and chemometric models were built to automate quantification of chemical targets. These models were validated through application to simulants and real Hanford process samples. Chemometric models performed well on both training and validation sets, suggesting these approaches can be successfully applied to on-line and real-time monitoring of low concentration Hanford processing streams. The use of the combine Raman wave lengths with the enhanced chemometric models for the low concentration streams significantly improved the chemical detection levels and significantly reduced uncertainties of those measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-dependent approach to inelastic scattering spectroscopies in and away from equilibrium: Beyond perturbation theory

We propose a nonperturbative numerical approach to calculate the spectrum of a many-body Hamiltonian with time and momentum resolution by exactly recreating a scattering event using the time-dependent Schrödinger equation. Akin to an actual inelastic scattering experiment, we explicitly account for the incident and scattered particles (e.g., photons, neutrons, electrons, etc.) in the Hamiltonian and obtain the spectrum by measuring the energy and momentum lost by the particle after interacting with the sample. We illustrate the method by calculating the spin excitations of a Mott-insulating Hubbard chain after a sudden quench with the aid of the time-dependent density matrix renormalization group method. Our formalism can be applied to different forms of spectroscopies, such as neutron and Compton scattering and electron-energy-loss spectroscopy, as an example.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tensor factorization for elucidating mechanisms of piezoresponse relaxation via dynamic Piezoresponse Force Spectroscopy

Spatially resolved time and voltage-dependent polarization dynamics in PbTiO 3 thin films is explored using dynamic piezoresponse force microscopy (D-PFM) in conjunction with interferometric displacement sensing. This approach gives rise to 4D data sets containing information on bias-dependent relaxation dynamics at each spatial location without long-range electrostatic artifacts. To interpret these data sets in the absence of defined physical models, we employ a non-negative tensor factorization method which clearly presents the data as a product of simple behaviors allowing for direct physics interpretation. Correspondingly, we perform phase-field modeling finding the existence of ‘hard’ and ‘soft’ domain wall edges. This approach can be extended to other multidimensional spectroscopies for which even exploratory data analysis leads to unsatisfactory results due to many components in the decomposition.

36 MATERIALS SCIENCE↗

Comparison of time-resolved photoluminescence and deep-level transient spectroscopy defect evaluations in an InAs nBn detector subjected to in situ and ex situ 63 MeV proton irradiation

Deep-level transient spectroscopy and temperature-dependent time-resolved photoluminescence experiments are performed on identical InAs nBn photodetector structures as a function of in situ and ex situ 63 MeV proton irradiation to assess their generation and recombination dynamics. Pre-irradiation, the n-type InAs absorbing region, exhibits a steadily increasing minority carrier lifetime with increasing temperature, providing evidence that excited minority carriers may be recombining via shallow defect levels. From deep-level transient spectroscopy, two features are found between 10 and 275 K: a low temperature broad “shoulder,” which suggests emission from multiple shallow electron defect levels with energies <29 meV and a high temperature minimum occurring at ∼230 K with an activation energy of 539 meV, which suggests a defect in the barrier layer in the device. Two similar nBn detectors are then subjected to 63 MeV proton irradiation in step doses and measured between steps. One experiment is performed in situ with an nBn held at ∼10 K during dosing, and the other experiment is performed ex situ with a similar nBn held at room temperature for dosing. The ex situ dosing results in an evaluation of the defect introduction rate that is three to four times lower than in situ due to partial annealing of the proton-induced displacement damage at room temperature. The results of these two experiments are then compared with the dose-dependent recombination rate analysis, resulting in an estimated recombination defect cross section of 1.6 × 10 −13 cm 2 for the shallow shoulder defect.

Carrasco, Rigo A. [Air Force Research Laboratory (↗

Out-of-equilibrium charge redistribution in a copper-oxide based superconductor by time-resolved X-ray photoelectron spectroscopy

Charge-transfer excitations are of paramount importance for understanding the electronic structure of copper-oxide based high-temperature superconductors. In this study, we investigate the response of a Bi 2 Sr 2 CaCu 2 O 8+δ crystal to the charge redistribution induced by an infrared ultrashort pulse. Element-selective time-resolved core-level photoelectron spectroscopy with a high energy resolution allows disentangling the dynamics of oxygen ions with different coordination and bonds thanks to their different chemical shifts. Our experiment shows that the O 1s component arising from the Cu–O planes is significantly perturbed by the infrared light pulse. Conversely, the apical oxygen, also coordinated with Sr ions in the Sr-O planes, remains unaffected. This result highlights the peculiar behavior of the electronic structure of the Cu–O planes. It also unlocks the way to study the out-of-equilibrium electronic structure of copper-oxide-based high-temperature superconductors by identifying the O 1s core-level emission originating from the oxygen ions in the Cu–O planes. This ability could be critical to gain information about the strongly-correlated electron ultrafast dynamical mechanisms in the Cu–O plane in the normal and superconducting phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

BODIPY based A-D-A molecules: Effect of CF3 group substitution at meso phenyl group

Two pairs of A-D-A molecules have been created with fluorene and benzodithiophene as the central donor subunits and terminal BODIPY units, functionalized with either a 4-methylphenyl or 4-trifluoromethylphenyl group at the meso position. The effect of the para substituent of the meso phenyl group on the photophysical properties of these molecules is studied through steady state absorption and fluorescence spectroscopy as well as femtosecond transient absorption and time resolved fluorescence spectroscopy techniques. Applicability of these molecules as donors in solution processed solar cell active layers was investigated through time resolved microwave conductivity measurements on blends with PC60BM acceptor, which shows a varying yield of charge transfer with choice of substituent. Transient absorption spectroscopy is then employed to investigate the role of the 4-trifluoromethylphenyl group in altering the efficiency of charge transfer from these A-D-A molecules to PC60BM. The results show a consistent picture of picosecond charge transfer and a component of a few hundred ps geminate recombination that results in a small yield of long-lived free charges optimized for the methylphenyl derivatives.

36 MATERIALS SCIENCE↗

Thermalization of the Kerr index of refraction in acetone and methanol using femtosecond pump-probe scattering spectroscopy

Femtosecond time-resolved pump-probe scattering is used to temporally investigate the index thermalization Δn(t) of the molecular motions associated with the Kerr nonlinear index n 2 . This is done using an intense 300 fs 1034 nm pump pulse and temporally probed by a 517 nm and supercontinuum pulse in acetone and methanol. The optically pumped molecular states change the index of refraction and through the processes of Raman and Rayleigh scattering are shown to engage in a 4-step energy relaxation process. Here, the pump first initiates the Kerr effect as well as populate resonant vibrational molecular motions, which act as a “mother” energy state. The electronic component of the Kerr effect is shown to couple with these vibrational modes through the process of Born-Oppenheimer coupling, which can be measured through the Raman scattering of the probe. The “mother” coupled state then decays into “daughter” anharmonic non-resonant states, which then further decay into “granddaughter” and thermal bath states. The population of these states alter the index of refraction in time, Δn(t), and can be measured through the changing in the probe beam’s Rayleigh scattering. This thermalization process takes ~5.5 ps in acetone and ~3.7 ps in methanol. The scattering signals from each Δn(t) thermalization stage in the localized region, (“mother”, to “daughter”, to “granddaughter”, to the bath states, to the ground state), are fitted to theoretical decay equations that show the rise and fall times of the energy decay routes.

47 OTHER INSTRUMENTATION↗

Time-Resolved X-ray Emission Spectroscopy and Synthetic High-Spin Model Complexes Resolve Ambiguities in Excited-State Assignments of Transition-Metal Chromophores: A Case Study of Fe-Amido Complexes

To fully harness the potential of abundant metal coordination complex photosensitizers, a detailed understanding of the molecular properties that dictate and control the electronic excited-state population dynamics initiated by light absorption is critical. In the absence of detectable luminescence, optical transient absorption (TA) spectroscopy is the most widely employed method for interpreting electron redistribution in such excited states, particularly for those with a charge-transfer character. The assignment of excited-state TA spectral features often relies on spectroelectrochemical measurements, where the transient absorption spectrum generated by a metal-to-ligand charge-transfer (MLCT) electronic excited state, for instance, can be approximated using steady-state spectra generated by electrochemical ligand reduction and metal oxidation and accounting for the loss of absorptions by the electronic ground state. However, the reliability of this approach can be clouded when multiple electronic configurations have similar optical signatures. Using a case study of Fe(II) complexes supported by benzannulated diarylamido ligands, we highlight an example of such an ambiguity and show how time-resolved X-ray emission spectroscopy (XES) measurements can reliably assign excited states from the perspective of the metal, particularly in conjunction with accurate synthetic models of ligand-field electronic excited states, leading to a reinterpretation of the long-lived excited state as a ligand-field metal-centered quintet state. Furthermore, a detailed analysis of the XES data on the long-lived excited state is presented, along with a discussion of the ultrafast dynamics following the photoexcitation of low-spin Fe(II)-N amido complexes using a high-spin ground-state analogue as a spectral model for the 5 T 2 excited state.

14 SOLAR ENERGY↗

Photophysical and Time‐resolved Infrared Properties of Long‐Lived Rhenium(I) 4,5‐Diazafluorene Tricarbonyl Chromophores

This report investigates the synthesis, structural characterization, fundamental molecular photophysics, electrochemistry, UV-Vis spectroelectrochemistry, and time-resolved infrared spectroscopic properties of eight [fac-Re(dafR)(CO) 3 L] 0/+ complexes, where R=ethyl [(dedaf); 1, 3, 5, 7] or H [(dafH); 2, 4, 6, 8] and L=Cl− (1, 2), imidazole [(Im); 3, 4], 4-ethylpyridine [(4-Etpy); 5, 6], or pyridine [(py); 7, 8]. Universally, 1–8 yield higher energy photoluminescence (PL) emission bands and higher PL quantum yields (up to 53 %) than the classic 2,2’-bipyridine (bpy) and 1,10-phenanthroline (phen) ligated Re(I) tricarbonyl complexes. The excited state lifetimes of 1–8 lie between those corresponding to the bpy and phen derivatives, ranging from 120 and 1300 ns at room temperature. Combinations of reductive UV-Vis spectroelectrochemistry, transient absorption spectroscopy, and time-resolved infrared spectroscopy consistently assigned the lowest excited states in 1–8 being of metal-to-ligand charge transfer (MLCT) character. These new ReI MLCT chromophores follow classic energy gap law behavior and possess the characteristics necessary for serving as valuable photosensitizers suitable to energize excited state electron and energy transfer photochemistry.

Charge transfer↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Time, momentum, and energy resolved pump-probe tunneling spectroscopy of two-dimensional electron systems

Abstract Real-time probing of electrons can uncover intricate relaxation mechanisms and many-body interactions in strongly correlated materials. Here, we introduce time, momentum, and energy resolved pump-probe tunneling spectroscopy (Tr-MERTS). The method allows the injection of electrons at a particular energy and observation of their subsequent decay in energy-momentum space. Using Tr-MERTS, we visualize electronic decay processes, with lifetimes from tens of nanoseconds to tens of microseconds, in Landau levels formed in a GaAs quantum well. Although most observed features agree with simple energy-relaxation, we discovered a splitting in the nonequilibrium energy spectrum in the vicinity of a ferromagnetic state. An exact diagonalization study suggests that the splitting arises from a maximally spin-polarized state with higher energy than a conventional equilibrium skyrmion. Furthermore, we observe time-dependent relaxation of the splitting, which we attribute to single-flipped spins forming skyrmions. These results establish Tr-MERTS as a powerful tool for studying the properties of a 2DES beyond equilibrium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Does Selectivity of Molecular Catalysts Change with Time? Polymerization Imaged by Single‐Molecule Spectroscopy

Abstract The chemoselectivity of molecular catalysts underpins much of modern synthetic organic chemistry. However, little is known about the selectivity of individual catalysts because this single‐catalyst‐level behavior is hidden by the bulk catalytic behavior. Here, for the first time, the selectivity of individual molecular catalysts for two different reactions is imaged in real time at the single‐catalyst level. This imaging is achieved through fluorescence microscopy paired with spectral probes that produce a snapshot of the instantaneous chemoselectivity of a single catalyst for either a single‐chain‐elongation or a single‐chain‐termination event during ruthenium‐catalyzed polymerization. Superresolution imaging of multiple selectivity events, each at a different single‐molecular ruthenium catalyst, indicates that catalyst selectivity may be unexpectedly spatially and time‐variable.

Garcia, IV, Antonio↗

Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients

We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.

(S2-FT-IR)↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

Substrate birefringence as a source of artifacts in spintronic THz emission spectra

Terahertz (THz) emission from spintronic THz emitters (STEs) has been extensively studied, both for its potential application in THz technologies and as a tool for probing spin dynamics, conductivity, and crystal anisotropy via time-domain THz spectroscopy. However, substrate birefringence can modify the emitted THz polarization, distorting the measured spectra and leading to potential misinterpretation of the results. While some aspects of substrate birefringence on THz emission have been studied in the time domain, its effects on THz spectra have not been discussed in detail. In the THz emission spectrum from STEs, we observe distinct spectral signatures that depend on sample orientation. To understand these signatures, we use STEs grown on c-cut sapphire and systematically vary the orientation of a (100) rutile TiO 2 window in both pump-through and THz-through geometries to identify the birefringence-induced effects. These findings demonstrate that substrate birefringence plays a critical role in the emitted THz spectrum and must be carefully considered in the analysis of time-domain THz spectroscopy data. We also show that artifacts from smaller birefringence can have a more misleading effect on the THz spectra.

Shrestha, Shreya [Univ. of Delaware, Newark, DE (U↗

Studies of surface adsorbate electronic structure and femtochemistry at the fundamental length and time scales. Final report

The electronic structure and ultrafast (10-15 s-femtosecond timescale) electron dynamics were investigated for clean and atom/molecule covered metal surfaces. The studies were performed by scanning tunneling microscopy (STM) to measure the structure of adsorbed atoms and molecules on metal surfaces, and to investigate their electronic properties. The electronic structure of the observed molecular networks was calculated by electronic structure theory in collaboration with Prof. Jin Zhao, who is a long-time collaborator, a Professor at the University of Science and Technology of China, and holds an Adjunct Professorship at the University of Pittsburgh. We also investigated the electronic properties of C60 molecules when they are templated by corrugated black phosphorous surfaces. We found unexpected charge delocalization that is enabled by the templating. This research was done in collaboration with Professor Min Feng at the Wuhan University, and who also holds an Adjunct Professorship at the University of Pittsburgh. Moreover, the electronic structure and electron dynamics in metal surfaces were investigated by time-resolved photoemission electron spectroscopy. The focus of ultrafast spectroscopy has been on the plasmonic response of silver surfaces. One direction has been to develop multidimensional (energy, momentum, and time) photoelectron spectroscopy of the coherent response of solid surfaces. This method was applied to study the collective electron excitations known generally as plasmons, which screen optical fields from penetration into metals. Although this collective response has been known for more than 60 years and is used extensively to deposit optical energy into metals, how this happens is poorly known. We investigated the plasmonic response of silver at the point where the dielectric response passes through zero and bulk plasmon is excited by light. We discovered that the plasmon excitation decays by exciting electrons from the Fermi level of a metal, which is contrary to what is believed in the plasmonic science community. This research has been performed in collaboration with Dr. Marcel Reutzel, who was a postdoctoral fellow working on this research at the University of Pittsburgh, and now has a faculty position at the University of Göttingen in Germany. Prof. Branko Gumhalter from the Institute of Physics in Zagreb contributed on the theory of plasmonic decay processes. Furthermore, we investigated the Floquet engineering of electronic bands in metals leading to multiphoton photoemission and above threshold photoemission. Finally, we demonstrated that it is possible to change the electronic structure of metals by application of optical fields. Our studies indicated that this happens on subfemtosecond time scale and could potentially be used in ultrafast information processing and quantum computation. Related document information

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advancing electrochemical impedance analysis through innovations in the distribution of relaxation times method

Electrochemical impedance spectroscopy (EIS) is a key tool across various scientific disciplines, including energy sciences, chemistry, and biology, enabling the analysis of electrochemical systems. However, conventional methods for interpreting EIS data are often complex and model dependent. The distribution of relaxation times (DRT) offers a non-parametric approach that simplifies the interpretation process by providing a timescale interpretation of EIS data. This article provides a comprehensive review of current methods for DRT inversion. Additionally, a survey of practitioners highlights key challenges in the field. Here, the findings underscore the need for standardized DRT analysis and benchmarks, as well as the development of automated analysis tools. These advancements would improve the usability and interpretability of EIS data. Ultimately, implementing these improvements could not only propel the field forward but also expand the application of DRT in scientific research by making it accessible to a broader range of researchers, including those without specialized expertise in programming or statistics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗