Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Atomistic Simulation of Track Formation by Energetic Recoils in Zircon

We have performed classical molecular dynamics simulations of fission track formation in zircon. We simulated the passage of a swift heavy ion through crystalline zircon using cylindrical thermal spikes with energy deposition (dE/dx) of 2.5 to 12.8 keV/nm and radius of 3 nm. At a low dE/dx of 2.55 keV/nm, the structural damage recovered almost completely and a damage track was not produced. At higher values of dE/dx, tracks were observed and the radius of the track increased with increasing dE/dx. Our structural analysis shows amorphization in the core of the track and phase separation into Si-rich regions near the center of the track and Zr-rich regions near the periphery. These simulations establish a threshold dE/dx for fission-track formation in zircon that is relevant to thermo-chronology and nuclear waste immobilization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Study of a Mini-Drift GEM Tracking Detector

In this paper, a GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a 1.6 cm drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge deposited in the drift region were measured on the readout plane which allowed the reconstruction of a short vector for the track traversing the chamber. The resulting position and angle information from the vector could then be used to improve the position resolution of the detector for larger angle tracks, which deteriorates rapidly with increasing angle for conventional GEM tracking detectors using only charge centroid information. Two types of readout planes were studied. One was a COMPASS style readout plane with 400 μm pitch XY strips and the other consisted of 2 × 10 mm 2 chevron pads. The detector was studied in test beams at Fermilab and CERN, along with additional measurements in the lab, in order to determine its position and angular resolution for incident track angles up to 45 degrees. Several algorithms were studied for reconstructing the vector using the position and timing information in order to optimize the position and angular resolution of the detector for the different readout planes. Finally, applications for large angle tracking detectors at RHIC and EIC are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking

Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID image acquisition at the frame rate of at least 4.29 Hz is recommended. Motion blurring in the images with frame rates below 4.29 Hz can significantly reduce the accuracy of autotracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-18A-05: Assessing Elekta MLC Tracking Performance

Purpose: To investigate the technical feasibility of using Elekta MLCs in tracked radiotherapy, specifically to show the capability of an Agility MLC to follow model tumor trajectories using object tracking. The system performance of the MLC is to be assessed via dosimetric experiments and temporal response measures. Methods: The system observer in the tracking cascade consisted of a camera serving for this proof of concept; Images of a moving object were acquired continuously and decorrelated for the position information, which was fed forward to the RT computer controlling the MLC via an interface provided by Elekta. The 1D motion (in the direction of the leaves) was induced by a CIRS motion controller. Additionally, the aperture position was observed by means of the light field of the linac. Calculating the phase between aperture and object yielded the mean aperture lag for the current setup. The object was restricted to sinusoidal motion with a period of 10s. For dosimetry, GafChromic radiosensitive film was irradiated with a total dose of 1000MU using an aperture size of 40mm and a motion range of 30mm. Results: Object tracking can substantially reconstruct the geometric dose response of a static target. In the dynamic case, dose is smeared out into the legs of the static distribution, leading to a reduced plateau and increased FWHM of 5mm, compared to the static width of 38mm. The time-lag between object and aperture was determined to be approximately 300ms for the current set-up. Conclusion: We demonstrated a tracking experiment performed on a clinical Elekta linear accelator for the first time. Observed profile variations show the dosimetric impact of tracked delivery. The determined lag is a valuable descriptor for a future tracking cascade employing predictor filters. The performed experiments are generic and possible predecessors for future applications with MR-Linac or ultrasound probes. Conflict of interest: this project is partly funded by Elekta.

60 APPLIED LIFE SCIENCES↗

Compensation of Axis Errors of Azimuth and Zenith Moving Concentrators in Programmable Solar-Tracking Systems

The solar-energy industry is currently concerned with improving software systems of sun-tracking concentrators. It is a feature of programmable tracking that there is no feedback from the tracked object, unlike in the case of optical tracking. In this regard, the accuracy of programmable tracking is affected by a large number of factors—in particular, axis-alignment errors. An error-checking algorithm is considered for the azimuth and zenith concentrator axes in programmable sun tracking. Effects of these errors on the accuracy of programmable tracking are assessed. It is shown that zenith axis errors have the same amount of influence as the vertical deviation of the azimuth axis, primarily affecting the azimuth angle, while its influence on the solar elevation can be neglected. The cumulative effect of axial errors is most noticeable when they have the same signs and lie in the same plane.

14 SOLAR ENERGY↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomistic simulation of track formation by energetic ions in zircon

We have performed classical molecular dynamics simulations of fission track formation in zircon. We simulated the passage of a swift heavy ion through crystalline zircon using cylindrical thermal spikes with energy deposition (dE/dx) of 2.5-12.8 keV nm{sup -1} and a radius of 3 nm. At a low dE/dx of 2.55 keV nm{sup -1}, the structural damage recovered almost completely and a damage track was not produced. At higher values of dE/dx, tracks were observed and the radius of the track increased with increasing dE/dx. Our structural analysis shows amorphization in the core of the track and phase separation into Si-rich regions near the center of the track and Zr-rich regions near the periphery. These simulations establish a threshold dE/dx for fission track formation in zircon that is relevant to thermochronology and nuclear waste immobilization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A formalism for extracting track functions from jet measurements

The continued success of the jet substructure program will require widespread use of tracking information to enable increasingly precise measurements of a broader class of observables. The recent reformulation of jet substructure in terms of energy correlators has simplified the incorporation of universal non-perturbative matrix elements, so called “track functions”, in jet substructure calculations. These advances make it timely to understand how these universal non-perturbative functions can be extracted from hadron collider data, which is complicated by the use jet algorithms. In this paper we introduce a new class of jet functions, which we call (semi-inclusive) track jet functions, which describe measurements of the track energy fraction in identified jets. These track jet functions can be matched onto the universal track functions, with perturbatively calculable matching coefficients that incorporate the jet algorithm dependence. We perform this matching, and present phenomenological results for the charged energy fraction in jets at the LHC and EIC/HERA at collinear next-to-leading logarithmic accuracy. We show that higher moments of the charged energy fraction directly exhibit non-linear Lorentzian renormalization group flows, allowing the study of these flows with collider data. Our factorization theorem enables the extraction of universal track functions from jet measurements, opening the door to their use for a precision jet substructure program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle filter-based modulation domain infrared targets tracking

Faced with problems of low contrast, poor SNR, and relatively complicated tracking environment, stable infrared target tracking is worth researching for its many potential applications. In this paper, instead of traditional target tracking in the pixel domain, we propose a sampling importance resampling (SIR) particle filter method with indirect velocity measurements to track infrared targets in the modulation domain. The dominant amplitude modulation (AM) features used for tracking is extracted by decomposing the input image using an 18-channel Gabor filter bank followed by the application of the dominant component analysis approach. The dominant AM modulation features provide a significant partial texture characteristic of the target which can be separated from background with better discrimination. To take advantage of observed kinematics, we utilize the augmented state vector with indirect velocity information via combining the measurements of velocity in adjacent frames to the SIR particle filter framework, which weakens weights of particles with bad velocity estimates but still having association with the cluttered background or other moving objects. A dynamic template update strategy is also provided to prevent the tracker from appearance model drift. Experiments indicate that the proposed method is effective for raising the tracking accuracy compared with other tracking methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Usefulness of Guided Breathing for Dose Rate-Regulated Tracking

Purpose: To evaluate the usefulness of guided breathing for dose rate-regulated tracking (DRRT), a new technique to compensate for intrafraction tumor motion. Methods and Materials: DRRT uses a preprogrammed multileaf collimator sequence that tracks the tumor motion derived from four-dimensional computed tomography and the corresponding breathing signals measured before treatment. Because the multileaf collimator speed can be controlled by adjusting the dose rate, the multileaf collimator positions are adjusted in real time during treatment by dose rate regulation, thereby maintaining synchrony with the tumor motion. DRRT treatment was simulated with free, audio-guided, and audiovisual-guided breathing signals acquired from 23 lung cancer patients. The tracking error and duty cycle for each patient were determined as a function of the system time delay (range, 0-1.0 s). Results: The tracking error and duty cycle averaged for all 23 patients was 1.9 {+-} 0.8 mm and 92% {+-} 5%, 1.9 {+-} 1.0 mm and 93% {+-} 6%, and 1.8 {+-} 0.7 mm and 92% {+-} 6% for the free, audio-guided, and audiovisual-guided breathing, respectively, for a time delay of 0.35 s. The small differences in both the tracking error and the duty cycle with guided breathing were not statistically significant. Conclusion: DRRT by its nature adapts well to variations in breathing frequency, which is also the motivation for guided-breathing techniques. Because of this redundancy, guided breathing does not result in significant improvements for either the tracking error or the duty cycle when DRRT is used for real-time tumor tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of Real-Time Internal Electromagnetic Position Monitoring Coupled With Dynamic Multileaf Collimator Tracking: An Intensity-Modulated Radiation Therapy Feasibility Study

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. Methods and Materials: A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Results: Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: {+-}3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Conclusions: Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking

Purpose: To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory monitoring, and to investigate the performance of a dynamic multileaf collimator tracking system using this method. Methods and Materials: The real-time three-dimensional internal target position estimation was established by creating a time-varying correlation model that connected the external respiratory signals with the internal target motion measured intermittently using kV/MV imaging. The method was integrated into a dynamic multileaf collimator tracking system. Tracking experiments were performed for 10 thoracic/abdominal traces. A three-dimensional motion platform carrying a gold marker and a separate one-dimensional motion platform were used to reproduce the target and external respiratory motion, respectively. The target positions were detected by kV (1 Hz) and MV (5.2 Hz) imaging, and external respiratory motion was captured by an optical system (30 Hz). The beam-target alignment error was quantified as the positional difference between the target and circular beam center on the MV images acquired during tracking. The correlation model error was quantified by comparing a model estimate and measured target positions. Results: The root-mean-square errors in the beam-target alignment that had ranged from 3.1 to 7.6 mm without tracking were reduced to <1.5 mm with tracking, except during the model building period (6 s). The root-mean-square error in the correlation model was submillimeters in all directions. Conclusion: A novel real-time target position estimation method was developed and integrated into a dynamic multileaf collimator tracking system and demonstrated an average submillimeter geometric accuracy after initializing the internal/external correlation model. The method used hardware tools available on linear accelerators and therefore shows promise for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Invisible ship tracks show large cloud sensitivity to aerosol

Cloud reflectivity is sensitive to atmospheric aerosol concentrations because aerosols provide the condensation nuclei on which water condenses. Increased aerosol concentrations due to human activity affect droplet number concentration, liquid water and cloud fraction, but these changes are subject to large uncertainties. Ship tracks, long lines of polluted clouds that are visible in satellite images, are one of the main tools for quantifying aerosol–cloud interactions. However, only a small fraction of the clouds polluted by shipping show ship tracks. Here we show that even when no ship tracks are visible in satellite images, aerosol emissions change cloud properties substantially. We develop a new method to quantify the effect of shipping on all clouds, showing a cloud droplet number increase and a more positive liquid water response when there are no visible tracks. We directly detect shipping-induced cloud property changes in the trade cumulus regions of the Atlantic, which are known to display almost no visible tracks. Our results indicate that previous studies of ship tracks were suffering from selection biases by focusing only on visible tracks from satellite imagery. The strong liquid water path response we find translates to a larger aerosol cooling effect on the climate, potentially masking a higher climate sensitivity than observed temperature trends would otherwise suggest.

54 ENVIRONMENTAL SCIENCES↗

Different X-ray spectral evolution for black hole X-ray binaries in dual tracks of radio-X-ray correlation

Recently, an 'outlier' track of radio-X-ray correlation was found, which is much steeper than the former universal correlation, where dual tracks were speculated to be triggered by different accretion processes. In this work, we test this issue by exploring hard X-ray spectral evolution in four black-hole X-ray binaries with multiple, quasi-simultaneous radio and X-ray observations. First, we find that hard X-ray photon indices, Γ, are negatively and positively correlated with X-ray fluxes when the X-ray flux, F{sub 3-9} {sub keV}, is below and above a critical flux, F{sub X,} {sub crit}, which are consistent with predictions of the advection-dominated accretion flow and the disk-corona model, respectively. Second, and most importantly, we find that the radio-X-ray correlations are also clearly different when the X-ray fluxes are higher and lower than the critical flux as defined by X-ray spectral evolution. The data points with F{sub 3-9} {sub keV} ≳ F{sub X,} {sub crit} have a steeper radio-X-ray correlation (F{sub X}∝F{sub R}{sup b} and b ∼ 1.1-1.4), which roughly forms the ''outlier'' track. However, the data points with anti-correlation of Γ – F{sub 3-9} {sub keV} either stay in the universal track with b ∼ 0.61 or stay in the transition track (from the universal to 'outlier' tracks or vice versa). Therefore, our results support that the universal and ''outlier'' tracks of radio-X-ray correlations are regulated by radiatively inefficient and radiatively efficient accretion model, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Role of ocean coupling in the weakening of the extratropical storm tracks from Arctic sea ice loss

Abstract Within the changing climate, the Northern Hemisphere storm tracks have been projected to shift poleward and expand eastward. Changes in the Northern Hemisphere storm tracks arise from a variety of sometimes competing effects on the region's baroclinicity. Arctic amplification weakens the meridional temperature gradient, hence weakening the storm track, while low-latitude warming has the opposite effect, and surface-amplified warming at high latitudes reduces static stability. To determine the mechanisms driving these competing changes, we use a hierarchy of models with different levels of ocean-atmosphere coupling, using forcings from the Polar Amplification Model Intercomparison Project (PAMIP) to assess the role of Arctic sea ice loss on the Northern Hemisphere storm tracks. We find that ocean-atmosphere coupling enhances and sharpens the weakening of both the North Atlantic and North Pacific storm tracks in response to Arctic sea ice loss, that surface turbulent heat flux modulates the intensity of the weakening, and that local ocean dynamics controls the meridional location of the response. A moist isentropic diagnostic of the atmospheric overturning circulation shows that most of the weakening of the storm tracks and its associated changes in atmospheric heat transport (AHT) arise from a weakening of the transient eddy mass flux. Poleward of the storm tracks, the AHT also decreases, but through weakened effective stratification rather than weakening mass fluxes, an effect which occurs even in the absence of ocean dynamical coupling.

Audette, Alexandre (ORCID:0000000163321088)↗

Comparative Performance of Three Eye-Tracking Devices in Detection of Mild Traumatic Brain Injury in Acute Versus Chronic Subject Populations

ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.

General & Internal Medicine↗

Effect of geometric and motion tracking error for awake small animal SPECT

A series of simulation studies were performed to evaluate the effects of geometric and motion tracking errors on reconstruction image quality for a single pinhole collimator awake animal imaging SPECT system. List-mode SPECT data generated using a custom Monte Carlo program that incorporated experimental mouse motion data were reconstructed by MLEM with Siddon's ray tracing. To better understand the impact of motion tracking and system geometric parameter errors on reconstructed system data, an offset of up to 1 mm or degree was separately applied to each for evaluation. In the absence of motion tracking or system geometric error, the applied motion compensation algorithm successfully reconstructed volumes without any degradation or distortion. Presented results reveal that motion tracking errors propagate through the SPECT reconstruction process. However, it is confirmed that the impact of tracking errors in the currently employed motion tracking system, is minimal because of their accuracy. The results also reveal the direct and indirect impact of geometric errors to motion compensated reconstruction quality and that a wrong assumption of pinhole transaxial position produces the most amount of distortion of all the investigated errors. Finally, system geometric errors are shown to have a greater impact on reconstruction quality than equivalent tracking errors.

60 APPLIED LIFE SCIENCES↗