Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗

Exploring Dynamic P-Q Capability and Abnormal Operations of Inverter-Based Resources

Nowadays, inverter-based resources are rapidly growing in electric power systems. On the other side, abnormal inverter operations are also occurring more often. Traditionally, inverter PQ capability charts are employed by electric utility companies to ensure safe and reliable operations of inverter-based resources. However, it is found in this paper that existing inverter PQ capability charts do not address the operating characteristics of an inverter correctly, which can result in irregular and unstable inverter operations. Here in this paper, a novel study is conducted to investigate inverter PQ capability charts, where constraints that are specific to an inverter are considered. It is found in this paper that the inverter PQ capability charts exhibit a unique dynamic nature under uncertain grid conditions. This dynamic nature has not been considered by the industry in managing, designing, and controlling an inverter as well as in developing international standards for inverter-based resources. Via both electromagnetic transient simulation and hardware experimental investigations, it is found that the dynamic PQ capability nature, together with the limitations of the existing control methods, are the underlying causes of many unusual inverter operations that have been reported in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Forming Control of PMSG-based Wind Turbines under Fault Conditions

Grid-forming control is widely envisioned as core technology ensuring stable operation of future power systems with increasing deployment of converter-interfaced renewable generation. However, research on grid forming control of wind turbines, especially under faults, is still in its early stages. In this context, this paper augments dual-port grid-forming control for type IV wind turbines with auxiliary controls to enable reliable fault ride through capabilities. In particular, the proposed control does not require a dc chopper or mode switching to grid-following control. Instead, energy-balancing dual-port GFM control is augmented with active rotor speed damping control and threshold virtual impedance for current limiting during faults. Different operating conditions of wind turbines are considered in a detailed electromagnetic transient simulation study to validate the effectiveness of the proposed control.

Lyu, Xue↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Laplace-Domain Circuit Model for Fault and Stability Analysis Considering Unbalanced Topology

For systems subject to unbalanced faults, analytical model building for stability assessment is a challenging task. This letter presents a straightforward modeling approach. A generalized dynamic circuit representation is achieved by use of the Laplacian transform variable s . Here, we translate the voltage and current relationship at the fault location into the relationship of three subsystems. The final circuit model is an interconnected sequence network with impedances in the Laplace domain. This circuit can be directly converted from a steady-state sequence network. This modeling procedure is illustrated by an example case of an induction motor served by a grid through a series compensated line. Electromagnetic transient simulation results demonstrate that sub-synchronous oscillations can be mitigated when a single-line to ground fault is applied at the motor terminal. Stability analysis results based on the dynamic circuit corroborate the simulation results. What's more, the derived circuit effortlessly reveals why unbalance can enhance stability.

42 ENGINEERING↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GIST (Grid Impedance Scan Tool) [SWR-22-73]

NREL has developed GIST (Grid Impedance Scan Tool) to scan the impedance response of inverter-based resources such as land-based and offshore wind power plants, solar power plants, etc., from their electromagnetic transient simulation models to evaluate their impact on grid stability. GIST can scan impedance response of inverter-based resources from vendor-supplied black-box simulation models without requiring internal proprietary details, enabling detailed stability analysis of power systems with high levels of inverter-based generation.

Shah, Shahil↗

PDC Modifications for Analysis of Gas-Cooled Reactors with Direct Helium Brayton Cycle

Capabilities of the Plant Dynamics Code (PDC) have been extended to allow steady-state and transient simulation of graphite-cooled reactors with direct helium Brayton cycle. On the cycle side, the most significant code modification is the addition of helium properties, in the format required by the code’s equations. Since the code was already formulated to handle more complex real gas properties, adding helium as working fluid that behaves like ideal gas was fairly straightforward. A reactor module was added to PDC to simulate a reactor cooled by the working fluid of the Brayton cycle. Two options are supported: channel type, typical for graphite gas-cooled reactors, and pin type, typical for light-water and liquid metal-cooled reactors. The reactor module is an extension of the electrical heater model and simulates heat deposition in the fuel and transfer of this heat from the fuel to the coolant through the matrix and tube materials. The new reactor module becomes the third option in PDC for modeling heat addition to the cycle, besides previously modeled heat addition heat exchanger and electrical heater. In addition to those changes, other minor code modifications and improvements were introduced during the work of expanding PDC to modeling of gas-cooled reactors. These modifications are summarized in the last chapter of this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark Specifications for Select Experiments Conducted at the Kansas State University Gallium Thermal-hydraulic Experiment Facility

The Department of Energy (DOE) – Nuclear Energy University Programs (NEUP) supported the creation and operation of the Gallium Thermal-hydraulic Experiment (GaTE) facility at Kansas State University (KSU) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. GaTE was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements describing stratification behavior in the coolant were collected for use as experimental benchmarks in validation efforts for computational models. The results of these tests contribute to a greater understanding of thermal stratification behavior of liquid metal under various configurations and operating conditions. This report provides a complete description of the benchmark problem, including all necessary details and description of a set of four forced flow and four natural circulation tests and measured data for comparison with model results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Specification for Select Experiments Conducted at the University of Wisconsin-Madison Thermal Stratification Test Facility

The Department of Energy (DOE)-Nuclear Energy University Programs (NEUP) supported the creation and operation of the Thermal Stratification Test Facility (TSTF) at the University of Wisconsin Madison (UWM) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. The TSTF was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements of the flow and temperature were collected for use as experimental benchmarks to support validation efforts for computational models. The results of these tests contribute to the greater understanding of thermal stratification behavior of liquid sodium under various configurations and operating conditions. The six TSTF tests selected for benchmarking are a set of forced circulation tests at a fixed flow rate with different Upper Internal Structure (UIS) configurations in the test section (no UIS, solid UIS, and a UIS with flow area of 4, 8, 12, and 100%). This report provides a complete description of the benchmark problems, including all key test facility details, descriptions of each test condition, and measured data for comparison with modeled results.

42 ENGINEERING↗

Final Report on Predictive Analyses of PRD as Function of Anomalies

This report summarizes the work completed in FY-2024 to analyze the power reactivity decrement (PRD) concepts of the ARC-100 core. The PRD has been traditionally defined by the reactivity change from a hot zero power (HZP) to a particular power. Consequently, the PRD accounts for the core reactivity changes due to increase coolant temperature gradient axially and radially across the core, and increased fuel temperature. The coolant temperature gradient leads to sodium and structure density changes, to radial core expansion from assembly flowering and bowing (due to axial and radial temperature gradients within the assemblies), and to control rod driveline thermal expansion. The fuel temperature increase associated with coolant temperature and power increases leads to Doppler effect and axial thermal expansion. In this work, the normal operating Hot Full Power (HFP) state is the only power level of interest, so analyses focus on the PRD calculated from HZP to HFP. The PRD has been used to assess the reactor safety features asymptotically in unprotected accident scenarios, including the loss of heat sink (LOHS), loss of flow (LOF), and transient overpower (TOP) without scram. The PRD concept relies on the “global” reactivity coefficients A, B, and C that are estimated based on “individual” reactivity effects (Doppler, sodium density, etc.). The objectives of this work are: 1) to improve and verify the methodology used to calculate the ABC coefficients used in the PRD, 2) to assess if the PRD can be used to reliably identify abnormal events. This report fulfills the FY-2024 scope of WBS#1.15.8.3 activity, “ANL0120 – Predictive Analyses of PRD as function of deformation”. The PRD concept is described in Sections 2. Additional effort in refining the methodology for core bowing modeling is performed in Sections 3. Then, two verification exercises are proposed in Section 4 to benchmark these coefficients based on direct neutronic-only calculations and on dynamic core transient simulations. Finally, the PRD approach is assessed for the detection of several unexpected events, such as primary flow perturbation or improper fuel loading, in Section 5.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced System Thermal Fluids Solver Development for SAM

This work summarizes a feasibility study on testing numerical algorithms that are suitable and efficient for advanced system analysis code development under the mutli-physics framework, MOOSE. The key is the implementation of a high-order one-dimensional staggered-grid finite volume method (SG-FVM), and its direct interaction with the linear/nonlinear solver, PETSc. Leveraging the existing capabilities of the SAM code, significant code coverages were established in the finite volume method code. This in turn allows for a suite of test problems with different problem sizes and levels of complexity to be used to quantify the performance improvement of the finite volume method code. As evidently shown in this study, the implemented SG-FVM demonstrated superior performance improvement against a direct finite element method implementation through MOOSE for the wide range of selected problems. On two computer systems, the speedup was observed to be significant, with at least one order of magnitude of solving time reduction. In addition, for a complex reactor model, transient simulation was performed using the finite volume method code, the results of which agree very well with the reference results from the finite element method code. Overall, this study demonstrates a successful feasibility study on the proposed numerical algorithms and software structure to support advanced system analysis tool development. In this work, short-term priority development and testing items were identified, and long-term code adoption and integration plans were made for the eventual deployment of the finite volume method in the SAM code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gas-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model Updates

This work presents the latest improvements to, and investigations performed with, the pebble-bed high-temperature gas-cooled reactor (PB-HTGR) reference plant models for the United States Nuclear Regulatory Commission. These models serve as the foundation for the future development of detailed design evaluation models based on license applications. The reference plant models have been developed with the Comprehensive Reactor Analysis Bundle, or BlueCRAB, which is the code suite proposed for non-light-water reactor systems safety analysis. It incorporates various simulation tools developed by the Nuclear Energy Advanced Modeling and Simulation program, including the Griffin code for reactor physics, the Pronghorn and SAM codes for core thermal fluids, the BISON code for solid conduction and fuel performance, and the SAM code for system analysis. The primary objective of the work that was performed was to assess BlueCRAB’s level of readiness for modeling a PB-HTGR. To do so, we first developed numerical models in BlueCRAB that include the key physics for this technology to ensure an adequate level of fidelity for modeling PB-HTGR core performance and for performing multiphysics simulations for equilibrium core conditions and different accident scenarios. Then we simulated transient scenarios, including depressurized and pressurized loss of forced cooling accidents, over-cooling, and control rod withdrawal events with delayed and prompt supercritical reactivity insertions. The analysis in this report includes comparisons of the 2D thermal fluid porous media models in Pronghorn and SAM, and comparisons of coupled SAM/Griffin/SAM and coupled Pronghorn/Griffin for depressurized and pressurized loss of forced cooling, over-cooling, and control rod withdrawal events. In addition, we compare 3D, 2D, and 0D/PKE neutronic models for the two control rod withdrawal scenarios with coupled Pronghorn/Griffin. The comparisons show that the BlueCRAB models lead to physically intuitive solutions for the scenarios examined. The changes in the various scalar and vector fields, such as neutron flux, power, temperature, density, pressure, and velocity, are within the expected ranges, and their distributions can be explained by the system response of the transients and the geometric and material variations. Several comparisons suggest that the porous media models in Pronghorn and SAM can lead to similar solutions, even though they are based on different methodologies. This work further highlights the need for flexible tools with various levels of fidelity to cover the breadth and depth of needs that may arise in future technical evaluations of the PB-HTGR. We believe that the BlueCRAB capabilities will be a significant asset for confirmatory analyses in order to resolve important safety questions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable the bulk integration of renewable resources into the future power grid; however, the performance of GFM inverters during unbalanced faults remains underexplored. This paper proposes a novel current-limiting method for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built in the stationary reference frame, to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a realtime digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBRonly scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗