Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Impact of the delayed energy deposition in TREAT on transient dynamics

Estimating the energy released during a reactivity insertion accident (RIA) is of prime importance. TREAT is an experimental reactor designed to simulate these transients. Typically, models of these transients assume instantaneous energy deposition. However, a delayed energy deposition component exists. This work leverages the advanced capabilities of ALFRED, a high-fidelity Monte Carlo code for particle transport, to study the impact of this delayed component on RIA transient dynamics in TREAT. The study reveals that the delayed component can affect the energy released by up to $3\%$ for natural pulse transients. Understanding the impact of the delayed energy deposition component will enable the development of more accurate models, which will assist in designing experiments in TREAT and evaluating their safety.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated Multi-Fidelity Model and Co-Simulation Platform for Distribution System Transient and Dynamic Analysis—DistribuDyn

As inverter-based, distributed energy resources (DERs) and variable loads continue to proliferate across distribution systems, it is increasingly important to understand their impacts on system stability and reliability. However, most commercially available simulation tools for distribution planning primarily focus on steady-state and quasi-steady state analysis, offering limited capabilities to study transient and dynamic behaviors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

RE-INTEGRATE EMT Simulation Software: Graph Convolutional Network for Sparse Matrix Pattern Detection

The increasing complexity of power networks, driven by proliferation of inverters, presents analytical challenges that simplified models often fail to capture, necessitating Electromagnetic Transient (EMT) simulations. EMT models are represented as discretized differential-algebraic equations (DAEs), forming a linear system Ax = b that is computationally intensive to solve. Due to inherent sparsity of adjacency matrix A, distinct patterns emerge that, when accurately identified, enable efficient solver selection to minimize computation time. However, identifying ideal pattern is complicated by numerous reordering algorithms and limited structural insights. To address this, we introduce a Graph Convolutional Network (GCN) model for classifying sparse matrix patterns common in power system analysis. The model, achieving 96% test accuracy, is validated using PV plant models of 125 MW capacities connected to New England 39-bus transmission system (TS), and further scaled to a 4,992-bus network with 384 PV plants, yielding 191, 616 × 191, 616 sized A matrix. For all cases, the GCN model accurately identifies the matrix’s intrinsic sparse pattern, demonstrating its potential to enhance solver performance in EMT analysis.

Hossain, Md Rifat [Florida International Universit↗

METHOD FOR EXPOSING IRRADIATED FUEL CLADDING TO RAPID THERMAL TRANSIENTS

Reactor core materials exposed to rapid thermal transients during accidents can experience significant changes in mechanical properties as irradiation hardness is recovered. Understanding material performance during transients using computer modeling requires accurate descriptions of mechanical property evolution with time and temperature. A simple experimental capability was developed to expose irradiated Zircaloy to a simulated thermal transient using immersion in molten tin (at 675°C) to rapidly heat and hold before rapidly cooling with a water quench. Multiple heating-cooling cycles using a nonirradiated tensile specimen showed simplicity and viability. Based on preliminary test results, a robust system was established for routine evaluation of simulated thermal accident scenarios in the Low Activation Materials Design and Analysis (LAMDA) laboratory at Oak Ridge National Laboratory (ORNL). This paper summarizes system development and nonirradiated Zircaloy commissioning test results. Future experiments will conduct tensile tests on irradiated Zircaloy after various rapid temperature profiles.

Byun, TS↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

Development of the TREAT M2 experiment as a transient benchmark

A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Emerging Computing Architectures: Simulation of Power Electronics in Power Grids

As the penetration of power electronics increases in power grids, new computing architectures needed to be evaluated for the simulation of high-fidelity models of power electronics in power grids in operations. In this paper, emerging computing architectures such as quantum processing units are evaluated for the simulation of power electronics in power grids. A hybrid algorithm based on classical computing and quantum computing is developed and tested for different use cases of electromagnetic transient (EMT) simulation of power electronics (PE)-based systems and simple circuits. The algorithms needed to simulate power electronics in emerging computing architectures are discussed and thereafter, simulation results are shown.

Debnath, Suman↗

Full-core high-burnup BWR LOCA fuel performance analysis and FFRD susceptibility

The susceptibility of the boiling water reactor (BWR) Limerick Unit 1 to fuel fragmentation, relocation, and dispersal during a postulated large-break loss-of-coolant accident (LBLOCA) was calculated using a multiphysics framework. The simulations include full-core, rod-resolved neutronic, thermal hydraulic, and fuel performance models using the VERA, TRACE, and BISON codes. This work focused on the transient BISON simulations, which include both the normal operation and LBLOCA periods in the same simulations. Cladding integrity was assessed using two correlations that are included with BISON. make page break Several new BWR-specific features were recently added to BISON. This work represents the first time these features have been included in a core-scale set of simulations. This study hence evaluates the performance of these new models for an operating reactor with realistic operating conditions. Simulation results showed that cladding integrity was maintained (i.e., no rods burst). Finally, future work to improve BWR and PWR predictions using this framework is suggested.

BISON↗

Parameterization of generic positive sequence models to represent behavior of inverter based resources in low short circuit scenarios

The connection of large inverter based resources (IBR) in transmission systems is often located geographically and electrically far away from load centers. This, coupled with the displacement of synchronous machine plants, results in a reduction of the network short circuit strength at the point of connection. Under these conditions, state-of-the-art positive sequence simulation platforms and models can have difficulties maintaining numerical stability and/or providing an accurate representation of IBR plant dynamic behavior. As a result, computationally heavy time domain electromagnetic transient (EMT) simulations may be required to evaluate these systems. In this paper, a recently developed improved generic positive sequence model is parameterized to provide a representation of IBR behavior in low short circuit networks. Further, comparisons against generic and detailed EMT models demonstrate the suitability of the improved positive sequence model to study practical stability issues experienced with presently in-service plants. Such a model can provide some of the accuracy of an EMT representation with a much lower computational burden. The performance of the positive sequence model is validated against the behavior shown by both open white box and closed black box EMT domain models from around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modelled land use and land cover change emissions – a spatio-temporal comparison of different approaches

Abstract. Quantifying the net carbon flux from land use and land cover changes (fLULCC) is critical for understanding the global carbon cycle and, hence, to support climate change mitigation. However, large-scale fLULCC is not directly measurable and has to be inferred from models instead, such as semi-empirical bookkeeping models and process-based dynamic global vegetation models (DGVMs). By definition, fLULCC estimates are not directly comparable between these two different model types. As an important example, DGVM-based fLULCC in the annual global carbon budgets is estimated under transient environmental forcing and includes the so-called loss of additional sink capacity (LASC). The LASC results from the impact of environmental changes on land carbon storage potential of managed land compared to potential vegetation and accumulates over time, which is not captured in bookkeeping models. The fLULCC from transient DGVM simulations, thus, strongly depends on the timing of land use and land cover changes mainly because LASC accumulation is cut off at the end of the simulated period. To estimate the LASC, the fLULCC from pre-industrial DGVM simulations, which is independent of changing environmental conditions, can be used. Additionally, DGVMs using constant present-day environmental forcing enable an approximation of bookkeeping estimates. Here, we analyse these three DGVM-derived fLULCC estimations (under transient, pre-industrial, and present-day forcing) for 12 models within 18 regions and quantify their differences as well as climate- and CO2-induced components and compare them to bookkeeping estimates. Averaged across the models, we find a global fLULCC (under transient conditions) of 2.0±0.6 PgC yr−1 for 2009–2018, of which ∼40 % are attributable to the LASC (0.8±0.3 PgC yr−1). From 1850 onward, the fLULCC accumulated to 189±56 PgC with 40±15 PgC from the LASC. Around 1960, the accumulating nature of the LASC causes global transient fLULCC estimates to exceed estimates under present-day conditions, despite generally increased carbon stocks in the latter. Regional hotspots of high cumulative and annual LASC values are found in the USA, China, Brazil, equatorial Africa, and Southeast Asia, mainly due to deforestation for cropland. Distinct negative LASC estimates in Europe (early reforestation) and from 2000 onward in the Ukraine (recultivation of post-Soviet abandoned agricultural land), indicate that fLULCC estimates in these regions are lower in transient DGVM compared to bookkeeping approaches. Our study unravels the strong dependence of fLULCC estimates on the time a certain land use and land cover change event happened to occur and on the chosen time period for the forcing of environmental conditions in the underlying simulations. We argue for an approach that provides an accounting of the fLULCC that is more robust against these choices, for example by estimating a mean DGVM ensemble fLULCC and LASC for a defined reference period and homogeneous environmental changes (CO2 only).

54 ENVIRONMENTAL SCIENCES↗

Enhancing EnergyPlus capabilities to model dynamic building envelopes using python plugin

Nearly half of the energy consumption in the United States is related to buildings, resulting in an urgent need to develop innovative technologies to improve building energy efficiency. Dynamic building envelopes, comprising switchable insulation and thermal energy storage materials, have been proposed recently as a promising solution to reduce buildings' heating and cooling loads by thermally coupling the indoor environment with the ambient environment when beneficial while decoupling them when outdoor conditions are not favorable. Although various related technologies are still underway, the whole-building energy modeling tools, like EnergyPlus, do not have the capability to simulate the transient and dynamic nature of dynamic envelope materials and components to accurately predict their impact on building energy use. The objective of this study is to formulate a method in EnergyPlus simulation engine to model multilayer envelopes, comprising dynamic building materials with variable thermophysical properties, and discuss the changes made to the program using a Python plugin. Furthermore, the thermal performance of the dynamic envelopes using the proposed method is compared and verified with the results from a well-established commercial code, COMSOL Multiphysics. A parametric assessment is also conducted to evaluate the energy efficiency benefits of dynamic envelopes in a single-family residential building, demonstrating total annual energy savings up to 11.6 %, when a dynamic envelope operates alone, and up to 18.2 % when it is combined with a thin layer of phase change material as a thermal storage medium. Finally, a United States wide energy efficiency assessment is presented to showcase the geographical spread of the energy savings. The method designed and implemented in this study provides the researchers with the ability to implement their dynamic insulation methods in EnergyPlus and evaluate the whole building energy impact.

25 ENERGY STORAGE↗

The Transient Multi-Level method for Monte Carlo reactor statics calculations

The Transient Multi-Level (TML) method is applied to a time-dependent Monte Carlo transport solver to offload some of the computational burden of the expensive Monte Carlo solve to lower-order Coarse Mesh Finite Difference (CMFD) and Exact Point Kinetics Equations (EPKE) solvers via factorization of the neutron flux at the transport and CMFD levels using the Predictor Corrector Quasi-Static Method (PCQM). The Monte Carlo transient is solved by a modified fission source iteration scheme that introduces a single transient source bank. The method is implemented in the production-level Monte Carlo code, Shift, and verified with prescribed reactivity ramps from the two-dimensional version of the C5G7-TD reactor benchmark. The results show that, as compared to other quasi-static methods, the TML reduces the stochastic noise inherent to the transient Monte Carlo solver by factors of ~2 to 6 for various norm comparisons of the reactor power amplitude. Finally, the TML additionally reduces the number of Monte Carlo evaluations needed to simulate the transient, leading to roughly an order of magnitude improvement in CPU time relative to the standard PCQM for the problems tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computationally inexpensive part-scale thermal history of additive friction-stir deposition

This study presents an analytical model for steady-state power generation and tool heat loss in additive friction-stir deposition (AFSD), developed to enable part-scale thermal simulation while remaining computationally inexpensive. The model predicts total generated power, yielding 3.7–4.7 kW across deposition temperature setpoints of 400–460 °C for the deposition of AA6061 with a Be-Cu tool. This corresponds to 90–95% of the reported spindle power. Tool heat loss is experimentally determined by calibrating a steady-state energy balance between the generated power, the substrate-deposition thermal gradient, and a temperature dependent tool heat loss term: q tool (T) = a + b (T - 400°C) with a = 2.7 x 10 6 Wm -2 and b = 9.5 x 10 3 Wm -2 K -1 . The calibration indicates that about 69% of the generated heat is conducted into the tool for this configuration, which is much higher than previously reported. The calibrated heat-source is implemented in finite element software (Adamantine) to simulate the transient thermal history of a 100 cm 3 representative build in 8 min on a standard desktop (at 0.635 mm build-height resolution). For the first three layers, the substrate temperatures between simulation and experiment are within 10% mean absolute percentage error. Sensitivity analysis indicates that uncertainties in average deposition temperature and deformation localization (stir-zone geometry, depth, and spatial dependance of strain-rate and flow stress) dominate model variance, motivating additional experimental verification.

Additive Friction-Stir Deposition↗

Fluoride-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model Updates

This work presents the latest improvements to, and investigations performed with, the Fluoride-Cooled High-Temperature Pebble-Bed Reactor reference plant models for the United States Nuclear Regulatory Commission. These models, developed with the Comprehensive Reactor Analysis Bundle, or BlueCRAB, serve as the foundation for the future development of detailed design evaluation models based on license applications. BlueCRAB is the code suite proposed for non-light-water reactor systems safety analyses, and it incorporates various simulation tools developed by the Nuclear Energy Advance Modeling and Simulation program, including the Griffin code for reactor physics, the Pronghorn and SAM codes for core thermal fluids, the BISON code for solid conduction and fuel performance, and the SAM code for system analysis. The primary objective of this work is to assess the level of readiness of BlueCRAB for modeling fluoride-cooled high-temperature pebble-bed reactors. We first developed numerical models in BlueCRAB that include the key physics for this technology, ensuring an adequate level of fidelity for modeling the core performance during accident scenarios. This was followed by simulation of transient scenarios, two loss-of-forced-cooling events (one protected and one unprotected), and two control rod withdrawal events (one delayed and one prompt supercritical reactivity insertion). The analysis includes comparisons between the 2-D thermal fluid porous media models in Pronghorn and SAM, comparisons between coupled Pronghorn-Griffin and coupled SAM-Griffin models for two loss-of-forced cooling events and one control rod withdrawal event, and comparisons between SAM single-solve and domain-overlapping approaches for multi-scale thermal fluid coupling. In addition, we performed comparisons between 3-D, 2-D, and 0-D neutronic models for the two control rod withdrawal scenarios with Pronghorn-Griffin. The results show that the BlueCRAB models led to physically intuitive solutions for the scenarios examined. The changes in the various scalar and vector fields such as the neutron flux, power, temperatures, densities, pressures, and velocities are all within the expected ranges, and their distributions can be explained from the system response of the transients and the geometric and material variations. Several comparisons suggest that the porous media models in Pronghorn and SAM can lead to similar solutions, even though they are based on different methodologies. The simulations demonstrate that there are differences between the various levels of fidelity, and it is advisable to have flexible tools that can cover the breadth and depth of needs that may arise in future technical evaluations. We believe that BlueCRAB’s capabilities represent a significant asset for confirmatory analyses aimed at resolving important safety questions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗