Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transmission x-ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Laboratory Investigation of the Growth and Crystal Structure of Nitric Acid Hydrates by Transmission Electron Microscopy (TEM)

A great deal of recent laboratory work has focussed on the characterization of the nitric acid hydrates, thought to be present in type I Polar Stratospheric Clouds (PSCs). Phase relationships and vapor pressure measurements (1-3) and infrared characterizations (4-5) have been made. However, the observed properties of crystalline solids (composition, melting point, vapor pressure, surface reactivity, thermodynamic stability, extent of solid solution with other components, etc.) are controlled by their crystal structure. The only means of unequivocal structural identification for crystalline solids is diffraction (using electrons, X-rays, neutrons, etc.). Other observed properties of crystalline solids, such as their infrared spectra, their vapor pressure as a function of temperature, etc. yield only indirect information about what phases are present, their relative proportions, or whether they are crystalline or amorphous.

Blake, David F.↗

Mechanical, Chemical and Microstructural Characterization of Monazite-Coated Silicon Carbide Fibers

Tensile strengths of as-received Hi-Nicalon and Sylramic fibers and those having monazite surface coatings, deposited by atmospheric pressure chemical vapor deposition, were measured at room temperature and the Weibull statistical parameters determined. The average tensile strengths of uncoated Hi-Nicalon and Sylramic fibers were 3.19 +/- 0.73 and 2.78 +/- 0.53 GPa with a Weibull modulus of 5.41 and 5.52, respectively. The monazite-coated Hi-Nicalon and Sylramic fibers showed strength loss of approx. 10 and 15 percent, respectively, compared with the as-received fibers. The elemental compositions of the fibers and the coatings were analyzed using scanning Auger microprobe and energy dispersive X-ray spectroscopy. The LaPO4 coating on Hi-Nicalon fibers was approximately stoichiometric and about 50 nm thick. The coating on the Sylramic fibers extended to a depth of about 100 to 150 nm. The coating may have been stoichiometric LaPO4 in the first 30 to 40 nm of the layer. However, the surface roughness of Sylramic fiber made this profile somewhat difficult to interpret. Microstructural analyses of the fibers and the coatings were done by scanning electron microscopy, transmission electron microscopy, and selected area electron diffraction. Hi-Nicalon fiber consists of fine beta-SiC nanocrystals ranging in size from 1 to 30 mn embedded in an amorphous matrix. Sylramic is a polycrystalline stoichiometric silicon carbide fiber consisting of submicron beta-SiC crystallites ranging from 100 to 300 nm. Small amount of TiB2 nanocrystallites (approx. 50 nm) are also present. The LaPO4 coating on Hi-Nicalon fibers consisted of a chain of peanut shape particles having monazite-(La) structure. The coating on Sylramic fibers consisted of two layers. The inner layer was a chain of peanut shape particles having monazite-(La) structure. The outer layer was comprised of much smaller particles with a microcrystalline structure.

Bansal, N. P.↗

The interaction of atomic oxygen with copper: An XPS, AES, XRD, optical transmission, and stylus profilometry study

The University of Alabama in Huntsville (UAH) experiment A-0114 was designed to study the reaction of material surfaces with low earth orbits (LEO) atmospheric oxygen. The experiment contained 128 one-inch circular samples; metals, polymers, carbons, and semiconductors. Half of these samples were exposed on the front of the Long Duration Exposure Facility (LDEF) and remaining on the rear. Among metal samples, copper has shown some interesting new results. There were two forms of copper samples: a thin film sputter-coated on fused silica and a solid piece of OFHC copper. They were characterized by x-ray and Auger electron spectroscopies, x-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to demonstrate the presence of Cu2O and CuO and to determine the oxidation states.

Raikar, Ganesh N.↗

Observation of hard X-rays from the Crab pulsar and A0535+26

The Crab pulsar PSR0531+21 was observed in a balloon flight from the Xianghe Balloon Station (China). Data were obtained in the range 20 to 200 keV with a poswish hard X-ray telescope which comprised a 150 sq cm primary crystal of 5 mm thick CsI(T1) which actively shielded the lower 2 pi steradians by a 5 cm thick NaI(T1) crystal. The scintillation pulses originating in CsI and NaI crystals are distinguished by pulse shape discrimination. The telescope has a field of view of approximately 4 deg H psi H pi determined by graded shield and collimator. The effective geometric area of the detector is 116 sq cm. It is noted that when folding a data flow on a long period interference from the data acquisition, transmission and recording system considerably affect the result.

Wu, M.↗

Coded aperture imaging with uniformly redundant arrays

The paper discusses uniformly redundant arrays (URA) as applied to coded aperture imaging. The URA system offers the high-transmission characteristics of random arrays as well as a flat sidelobe advantage. The high-transmission yields the imaging of very low-intensity sources and the flat sidelobes provide the suppression of inherent noise which obscures low-contrast sources. Simulations have shown that the URA with shot and background noise produces a better reconstructed object than random arrays without shot or background noise. The URA also offers an arrangement which involves a mosaic of basic URA patterns forming a circular correlation of the object on the picture plane. Thus the information needed to reconstruct the object is contained in an area equal to that of the basic aperture pattern. This smaller required detector is important in applications including X-ray astronomy.

Fenimore, E. E.↗

Microstructure, Chemistry, and Origin of Grain Rims on ilmenite from the Lunar Soil Finest Fraction

Analytical transmission electron microscope (TEM) observations reveal that ilmenite grains sampled from the sub-10 micron size fraction of Apollo 11 (10084) and Apollo 16 (61221, 67701) soils have rims 10-300 nm thick that are chemically and microstructurally distinct from the host ilmenite. The rims have a thin outer sublayer 10-50 nm thick that contains the ilmenite-incompatible elements Si, Al, Ca and S. This overlies a relatively thicker (50-250 nm) inner sublayer of nanocrystalline Ti-oxide precipitates in a matrix of single-crystal ilmenite that is structurally continuous with the underlying host grain. Microstructural information, as well as data from x-ray spectrometry (EDS) and electron energy loss spectrometry (EELS) analysis of the inner sublayer, suggest that both the inner and outer sublayer assemblages are reduced and that the inner layer is depleted in Fe relative to the underlying ilmenite. The chemistry of the outer sublayer suggests that it is a surface deposit of sputtered or impact-vaporized components from the bulk lunar soil. The inner sublayer is part of the original host grain that has been physically and chemically processed, but not amorphized, by solar ion irradiation and possibly some subsolidus heating. The fact that the deposited outer sublayer is consistently much thinner than the radiation-altered inner sublayer indicates that only a minor fraction of the total rim volume is a product of vapor or sputter deposition. This finding is in contrast to recent descriptions of thick deposited layers on one-third of regolith silicate grains and indicates that ilmenite and silicate rims as a group are different in the fraction of deposited material that they contain.

Christoffersen, Roy↗

SPIKE: Application for ASTRO-D mission planning

SPIKE is a mission planning software system developed by a team of programmers at the STScI for use with the Hubble Space Telescope (HST). SPIKE has been developed for the purpose of automating observatory scheduling to increase the effective utilization and ultimately, scientific return from orbiting telescopes. High-level scheduling strategies using both rule-based and neural network approaches have been incorporated. Graphical displays of activities, constraints, and schedules are an important feature of the system. Although SPIKE was originally developed for the HST, it can be used for other astronomy missions including ground-based observatories. One of the missions that has decided to use SPIKE is ASTRO-D, a Japanese X-ray satellite for which the U.S. is providing a part of the scientific payload. Scheduled to fly in Feb. 1993, its four telescopes will focus X-rays over a wide energy range onto CCD's and imaging gas proportional counters. ASTRO-D will be the first X-ray imaging mission operating over the 0.5-12 keV band with high energy resolution. This combination of capabilities will enable a varied and exciting program of astronomical research to be carried out. ASTRO-D is expected to observe 5 to 20 objects per day and a total of several thousands per year. This requires the implementation of an efficient planning and scheduling system which SPIKE can provide. Although the version of SPIKE that will be used for ASTRO-D mission is almost identical to that used for the HST, there are a few differences. For example, ASTRO-D will use two ground stations for data downlinks, instead of the TDRSS system for data transmission. As a consequence ASTRO-D is constrained by limited on-board data storage capacity to schedule high data-rate observations during periods of frequent high bit rate observations accordingly. We will demonstrate the ASTRO-D version of SPIKE to show what SPIKE can provide and how efficiently it creates an observational schedule.

Isobe, T.↗

Laboratory Astrophysics Using a Spare XRS Microcalorimeter

The XRS instrument on Astro-E is a fully self-contained microcalorimeter x-ray instrument capable of acquiring optimally filtering, and characterizing events for 32 independent pixels. With the launch of the Astro-E spacecraft, a full flight spare detector system has been integrated into a laboratory cryostat for use on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory. The detector system contains a microcalorimeter array with 32 instrumented pixels heat sunk to 60 mK using an adiabatic demagnetization refrio,erator. The instrument has a composite resolution of 8eV at 1 keV and 12eV at 6 keV with a minimum of 95% quantum efficiency. This will allow high spectral resolution, broadband observations of collisionally excited plasmas which are produced in the EBIT experiment. Unique to our instrument are exceptionally well characterized 1000 Angstrom thick aluminum on polyimide infrared blocking filters. The detailed transmission function including the edc,e fine structure of these filters has been measured in our laboratory using an erect field grating spectrometer. This will allow the instrument to perform the first broadband absolute flux measurements with the EBIT instrument. The instrument performance as well as the results of preliminary measurements will be discussed. Work performed under the auspices of the U.S. D.o.E. by Lawrence Livermore National Laboratory under contract W-7405-ENG-48 and was supported by the NASA High Energy Astrophysics Supporting Research and Technology Program.

Audley, M. Damian↗

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗

Ascorbate, added after irradiation, reduces the mutant yield and alters the spectrum of CD59- mutations in A(L) cells irradiated with high LET carbon ions

It has been reported that X-ray induced HPRT- mutation in cultured human cells is prevented by ascorbate added after irradiation. Mutation extinction is attributed to neutralization by ascorbate, of radiation-induced long-lived radicals (LLR) with half-lives of several hours. We here show that post-irradiation treatment with ascorbate (5 mM added 30 min after radiation) reduces, but does not eliminate, the induction of CD59- mutants in human-hamster hybrid A(L) cells exposed to high-LET carbon ions (LET of 100 KeV/microm). RibCys, [2(R,S)-D-ribo-1',2',3',4'-Tetrahydroxybutyl]-thiazolidene-4(R)-ca riboxylic acid] (4 mM) gave a similar but lesser effect. The lethality of the carbon ions was not altered by these chemicals. Preliminary data are presented that ascorbate also alters the spectrum of CD59- mutations induced by the carbon beam, mainly by reducing the incidence of small mutations and mutants displaying transmissible genomic instability (TGI), while large mutations are unaffected. Our results suggest that LLR are important in initiating TGI.

NASA Discipline Radiation Health↗

Determination of plasma temperatures and luminosities using multiple extreme-ultraviolet and X-ray filters

We carefully examine the techniques used to infer temperatures of stellar coronal plasmas from the count rates of several broadband instruments in the X-ray and extreme-ultraviolet spectral ranges. In particular, we determine to what extent temperatures can be constrained and the corresponding uncertainties in the luminosities and emission measures lowered by fitting simultaneously count rates from the Einstein imaging proportional counter (IPC), the ROSAT Position Sensitive Proportional Counter (PSPC), the ROSAT Wide Field Camera (WFC) (both filters), and the EXOSAT Low Energy Telescope (LET) with the 3-Lex filter. We use published plasma emissivities with solar photospheric abundances. Since it has been found that single-temperature plasmas do not fit IPC data well, we assume a two-temperature plasma model. We find that, even with count rates from all of the above filters and overly optimistic error estimates, it is still not possible to determine a unique two-temperature solution. However, since the use of count rates from many filters can reduce substantially the number of possible solutions, temperature solutions determined by other means can be tested. We carry out such an analysis on a set of 18 nearby late-type stars to determine possible two-temperature solutions using multifilter photometry, and we compare these results with the temperature solutions derived by Schmitt et al. (1990) using IPC spectral data. In general, the two-temperature fits derived from the IPC spectral data are inconsistent with our results, with our data implying that, for many stars, the two temperatures derived by the IPC may be too low by about a factor of 2. The EXOSAT transmission grating Spectrometer (TGS) spectra of capella and sigma(exp 2) CrB support this conclusion. For Procyon and 70 Oph, though, the presence of a temperature component cooler than a million degress (not detected by the IPC) is deduced. While our analysis suggests the existence of more than one temperature in the coronae of late-type stars, in many instances our WFC data appear to be inconsistent with the presence of significant emission measure over a broad temperature distribution. This, together with the success of two-temperature plasmas in fitting IPC and TGS data, implies that for many stars, the coronal emission measure distribution may in fact be dominated by two distinct temperature regimes.

Wood, Brian E.↗

Imaging slitless spectrometer for X-ray astronomy

Imaging slitless spectrometer, a combination of an X ray transmission /or reflection/ grating and image-forming X ray telescope, is capable of obtaining simultaneous spatial and spectral information about celestial X ray sources.

Gursky, H.↗

Microscopic observations of X-ray and gamma-ray induced decomposition of ammonium perchlorate crystals

The X-ray and gamma-ray induced decomposition of ammonium perchlorate was studied by optical, transmission, and scanning electron microscopy. This material is a commonly used oxidizer in solid propellents which could be employed in deep-space probes, and where they will be subjected to a variety of radiations for as long as ten years. In some respects the radiation-induced damage closely resembles the effects produced by thermal decomposition, but in other respects the results differ markedly. Similar radiation and thermal effects include the following: (1) irregular or ill-defined circular etch pits are formed in both cases; (2) approximately the same size pits are produced; (3) the pit density is similar; (4) the c face is considerably more reactive than the m face; and (5) most importantly, many of the etch pits are aligned in crystallographic directions which are the same for thermal or radiolytic decomposition. Thus, dislocations play an important role in the radiolytic decomposition process.

Herley, P. J.↗

Large-aperture high-resolution X-ray collimator for the Solar Maximum Mission

A description is presented of a flight-qualified large-aperture 12 x 12-arcsec angular resolution multigrid X-ray collimator developed for the Solar Maximum Mission (SMM) flat crystal spectrometer. This collimator, designed for the 1.4-22.4-A wavelength range, utilizes an optical bench/metering structure to align and support prealigned grid subassemblies. The optical bench is a lightweight, rigid, and stable aluminum honeycomb structure. The grids are of a compound and bimetallic design, having 63.5-micron square holes on an 88.9-micron spacing in 8-micron thick gold, which is in turn supported by a 76-micron thick Invar grid having 600-micron square holes on a 739-micron spacing. The small apertures in the gold provide the 12-arcsec collimation with the Invar grids providing wide angle off-axis blocking out to an approximately 35 arcmin view angle. The collimator has seven individual channels, four of a 5.1- x 10-cm area and three of a 1.3- x 10-cm area. Laboratory measurements gave an average angular resolution of 12.5 arcsec FWHM with 0.259 transmission for the large-area channels and 12.0 arcsec and 0.200 transmission for the small-area channels. A thermal filter composed of two layers of approximately 1000-A thick aluminum prevents solar heating of the front collimator grids by absorbing longer wavelength radiation while passing most of the X radiation in the band of interest.

Nobles, R. A.↗

Optical fibers and components experiment (A0138-7)

Fiber optics permanent damages induced by ionizing radiation after a long exposure in space and after laboratory tests were examined. Irradiation tests performed with radioactive sources (Sr90 - Y90) were validataed, computer coses used for the fluence and dose profile were verified. The performance of fiber optics waveguides in a low altitude orbit, and the origin of transmission losses in the material were dtermined. High sensitivity to ionizing radiations, however, may be a restriction for optic fiber use on satellites. Irradiation tests on these components using neutrons, gamma rays, and X-rays are carried out. Radiation damage on opticao materials, however, is strongly linked to the test conditions.

Bourrieau, J.↗

High-resolution imaging gamma-ray spectroscopy with externally segmented germanium detectors

Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. An angular resolution of 0.2 deg becomes practical by combining position-sensitive germanium detectors having a segment thickness of a few millimeters with a one-dimensional coded aperture located about a meter from the detectors. Correspondingly higher angular resolutions are possible with larger separations between the detectors and the coded aperture. Two-dimensional images can be obtained by rotating the instrument. Although the basic concept is similar to optical or X-ray coded-aperture imaging techniques, several complicating effects arise because of the penetrating nature of gamma rays. The complications include partial transmission through the coded aperture elements, Compton scattering in the germanium detectors, and high background count rates. Extensive electron-photon Monte Carlo modeling of a realistic detector/coded-aperture/collimator system has been performed. Results show that these complicating effects can be characterized and accounted for with no significant loss in instrument sensitivity.

Callas, J. L.↗

Organometallic chemical vapor deposition and characterization of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates

The epitaxial growth of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates by open tube organometallic chemical vapor deposition (OMCVD) is reported. The chemical composition of the alloys characterized by energy dispersive X-ray spectroscopy shows that alloys with x up to 0.13 can be deposited on (001) GaP. Epitaxial growth with mirror smooth surface morphology was achieved for x less than or equal to 0.05. Transmission electron microscopy (TEM) micrographs of these alloys show specular epitaxy and the absence of microstructural defects indicating a defect density of less than 10(exp 7) cm(sup -2). Selected area electron diffraction pattern of the alloy shows that the epitaxial layer crystallizes in the chalcopyrite structure with relatively weak superlattice reflections indicating certain degree of randomness in the cation sublattice. Hall measurements show that the alloys are p-type, like the unalloyed films; the carrier concentration, however, dropped about 10 times from 2 x 10(exp 18) to 2 x 10(exp 17) cm(sup -3). Absorption measurements indicate that the band tailing in the absorption spectra of the alloy was shifted about 0.04 eV towards shorter wavelength as compared to the unalloyed material. Diodes fabricated from the n(+)-GaP/p-ZnSiP2-ZnGeP2-Ge heterostructure at x = 0.05 have a reverse break-down voltage of -10.8 V and a reverse saturation current density of approximately 6 x 10(exp -8) A/sq cm.

Xing, G. C.↗