Search NASA⌕ Search

SEARCH · Search NASA

Results for “Turning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A 50 kA Superconducting Transformer for the Upcoming High-Field High-Current Testing Station at the BNL

Brookhaven national laboratory is upgrading its existing user facility to support R&D for High Energy Physics (HEP) and Fusion Energy Sciences (FES). The goal of this upgrade is to host the testing of the superconducting cables, conductors, joints and insert coils under high magnetic field (10 T), with currents up to 50 kA (present limit 20 kA) and at temperatures varying from 4 K to 40 K. To provide a current up to 50 kA to the sample, a superconducting core-less transformer is under construction. The superconducting transformer would additionally reduce the heat loss at the current leads at high currents. The SC transformer consists of two coaxial coils. The primary coil is inside the secondary coil. The primary coil consists of 3048 turns of rectangular wires (1.91 mm x 1.27 mm), wound in 24 layers. The secondary coil consists of 13 turns of the secondary cable (18.35 mm x 5.96 mm), wound in one layer. The parameters of the transformer are chosen to satisfy the space restrictions while using the available conductor. Here this paper presents the design of the 50-kA transformer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of the MQXFB Nb 3 Sn Quadrupoles for the HL-LHC

Here, the cold powering test of the first two prototypes of the MQXFB quadrupoles (MQXFBP1, now disassembled, and MQXFBP2), the Nb 3 Sn inner triplet magnets to be installed in the HL-LHC, has validated many features of the design, such as field quality and quench protection, but has found performance limitations. In fact, both magnets showed a similar phenomenology, characterized by reproducible quenches in the straight part inner layer pole turn, with absence of training and limiting the performance at 93% (MQXFBP1) and 98% (MQXFBP2) of the nominal current at 1.9 K, required for HL-LHC operation at 7 TeV. Microstructural inspections of the quenching section of the limiting coil in MQXFBP1 have identified fractured Nb 3 Sn sub-elements in strands located at one specific position of the inner layer pole turn, allowing to determine the precise origin of the performance limitation. In this paper we outline the strategy that has been defined to address the possible sources of performance limitation, namely coil manufacturing, magnet assembly and integration in the cold mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison and Discussion on Shortcircuit Protections for Silicon-Carbide MOSFET Modules: Desaturation Versus Rogowski Switch-Current Sensor

Survivability of silicon-carbide (SiC) mosfet modules during short circuit (SC) is essential for modern power electronics systems due to large economic implications. SiC mosfet modules exhibit narrow SC withstand times and generally much lower SC robustness than silicon (Si) insulated-gate bipolar transistors (IGBTs). This puts a critical concern on their utilization, further stressing the importance of reliable protection. This article presents a comprehensive analysis and discussion on the SiC mosfet module SC protection and performance comparison between conventional desaturation detection, previously used for Si IGBT protection, and Rogowski switch-current sensor (RSCS) detection. In addition, this article presents the experimental design for soft turn-off as a reaction to the SC detection to avoid excessive overshoots during the abrupt turn-off of the SC current. To perform different types of SC with various fault inductances on different temperatures, and for the sake of fair comparison under the same conditions, a gate-driver unit for 1.2 kV SiC mosfet half-bridge modules is developed containing both detection methods. The results demonstrate that both methods are successful in protecting the module in all SC types, with superiority of the RSCS detection and concerns for desaturation detection in high-inductance and high dc-bus voltage SC events.

42 ENGINEERING↗

Field-Emission Properties of Vertically Aligned Carbon Nanotube Cathodes of Varying Geometries

This work characterizes the bulk emission properties of carbon nanotube (CNT) forest cathodes fabricated with various geometries. Geometries explored include dense nanotube forests of varying height grown on 5×5 mm silicon (Si) substrates and discrete, patterned CNT pillars fabricated using UV photolithography. Dense forests heights ranged from 526 μ m to 1.41 mm, with packing fraction for dense forest calculated to be 4e10 nanotubes/cm2 based on an average nanotube separation distance of 100 nm for fixed growth dense forests. Patterned sample micro pillar heights ranged from 47 to 393 μ m with pillar widths on tested samples ranging from 250 to 270 μ m . Properties explored include emission current, turn-on field, and emission current performance over time. A parallel plate electron beam diode with a 100- μ m A-K gap and an automated test apparatus were developed to provide a configurable experiment that provides accurate and repeatable measurements for dc, dc sweep, and timed performance testing. Operating voltages for the voltage sweeps spanned from 0 to −350 V. Furthermore, testing has shown evidence of a hysteresis effect on the emission current tied to the applied field history as well as shifting of the turn-on field magnitude throughout the testing period, suggesting a conditioning effect during use. Three separate emission regions in the I–V curves during sweep testing have also been observed. In the geometric study, dense forests and patterned samples were sweep tested up to a peak applied voltage of −250 V, with the taller samples generally performing better. Currents produced in the geometric study from the dense forest emitters ranged from 36.8 to 572.34 μ A , with current densities ranging from 15 to 2.29 mA/cm2. Currents produced from the patterned micropillar emitters ranged from 39.4 to 317.51 μ A , with current densities ranging from 67 to 3 mA/cm2. DC time testing s...

36 MATERIALS SCIENCE↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

Comparison of the Capacitances and Switching Losses of 1.2 kV Common-Source and Common- Drain Bidirectional Switch Topologies

Bidirectional, or four-quadrant switches (FQS) can be designed as back-to-back MOSFETs connected in common-drain (CD) or common-source (CS) topologies. CDFQS and CS-FQS assembled from discrete 1.2 kV commercially available SiC power MOSFETs were characterized to obtain capacitance and switching loss values. The CD-FQS exhibited a 1.17x larger turn-on loss compared to the CS-FQS, while the CS-FQS exhibited a 1.52x larger turn-off loss compared to the CD-FQS. The CS-FQS exhibited a lower input capacitance, while the CD-FQS exhibited a lower output and reverse transfer capacitance.

Silicon Carbide, Bidirectional Switch, Switching P↗

Automating Traffic Microsimulation from SYNCHRO UTDF to SUMO

Modern transportation research relies on seamlessly integrating traffic signal data with robust network representation and simulation tools. This study presents utdf2gmns, an open-source Python tool that automates conversion of the Universal Traffic Data Format, including network representation, signalized intersections, and turning volumes into the General Modeling Network Specification (GMNS) Standard. The resulting GMNS-compliant network can be converted for microsimulation in SUMO. By automatically extracting intersection control parameters and aligning them with GMNS conventions, utdf2gmns minimizes manual preprocessing and data loss. utdf2gmns also integrates with the Sigma-X engine to extract and visualize key traffic control metrics, such as phasing diagrams, turning volumes, volume-tocapacity ratios, and control delays. This streamlined workflow enables efficient scenario testing, accurate model building, and consistent data management. Validated through case studies, utdf2gmns reliably models complex urban corridors, promoting reproducibility and standardization. Documentation is available on GitHub and PyPI, supporting easy integration and community engagement.

Luo, Roy [ORNL] (ORCID:0009000312909983)↗

How deep should we go to understand roots at the top of the world?

Harsh environmental conditions and the short summers of northern, high-latitude biomes impose unique constraints on the plants that live in the arctic tundra and the boreal forest. To escape the harsh aboveground environment, plants in these habitats often allocate a large portion of their biomass belowground to facilitate nutrient acquisition. In turn, the proximity of living plant roots to vast stores of sequestered soil carbon in these biomes means that shifts in rooting depth distribution and the size of the root–soil interface could significantly contribute to ongoing climate change. Indeed, plant ‘priming’ of rhizosphere decomposition via root exudation, particularly from shallowly distributed roots, can lead to losses of carbon from tundra soils. While we have a hard-won understanding of the distribution of plant communities across the arctic tundra and the boreal forest from direct field observations scaled to the landscape level using climate-informed mapping techniques (i.e. the Circumpolar Arctic Vegetation Map (CAVM); Walker et al. , 2005), these vegetation maps are only the tip of the iceberg (Iversen et al. , 2015). Root form and function remain hidden beneath the land surface. In an article recently published in New Phytologist , Blume-Werry et al. (2023, 10.1111/nph.18998) asked whether rooting depth distribution, and ensuing carbon emissions, could be inferred from commonly used vegetation mapping classifications across the pan-Arctic. An important question to guide our understanding, mapping, and prediction of belowground characteristics and ecosystem feedbacks at the top of the world. Unfortunately, they found that the answer was ‘not quite’. While rooting depth distribution varied demonstrably, in turn causing substantial changes in modeled carbon emissions via rhizosphere ‘priming’, variation across rooting depth profiles did not correspond with vegetation mapping classes. If we are unable to predict belowground rooting depth distributions across large spatial scales by leveraging aboveground vegetation community distributions, how then should belowground researchers proceed?

59 BASIC BIOLOGICAL SCIENCES↗

High current density electron emission from an electrodeposited metal nanowire array

High-current electron field emitters are of interest for many applications, but state-of-the-art devices suffer from limitations such as high turn-on macroscopic field, low macroscopic current density, poor emission stability, and short lifetime. Field emitter arrays with a high spatial density of uniform emitters have the potential to address these problems. This work presents the process development, fabrication, and testing of a novel field emitter array. The authors employed electron beam lithography and templated electrodeposition to fabricate a high spatial density array of metallic nanowires, resulting in electron emission with high macroscopic current density (2 A/cm 2 ) and low turn-on macroscopic field (4.35 V/ μ m). Templated electrodeposition of metallic nanowire arrays is a promising method for producing high performance field emitters.

42 ENGINEERING↗

The elastic vacuum

The quantum gravity vacuum must contain virtual fluctuations of black hole microstates. These extended-sized fluctuations get “crushed” when a closed trapped surface forms, and turn into on-shell “fuzzball” states that resolve the information puzzle. We argue that these same fluctuations can get “stretched” by the anti-trapped surfaces in an expanding cosmology, and that this stretching generates vacuum energy. The stretching happens when the Hubble deceleration reduces quickly, which happens whenever the pressure drops quickly. We thus get an inflation-scale vacuum energy when the heavy GUTS particles become nonrelativistic, and again a small vacuum energy when the radiation phase turns to dust. The expansion law in the radiation phase does not allow stretching, in agreement with the observed irrelevance of vacuum energy in that phase.

Astronomy & Astrophysics↗

Motility Analysis of T-Cell Histories in Activation (Matcha) v0.1.0

Despite advances in microscopy, imaging techniques only capture a very small spatial and temporal fraction of T cell activity within a tissue. For this reason, we have pursued the development of a virtual T cell model. Matcha's objective is to design virtual T cells that move like biological T cells. The virtual T cells will match the speed and turning angle distributions of biological cells. In addition, Matcha will also attempt to match the volume patrolled by the biological cells and the dependence on speed and turning angle on the previous speed.

Rouson, Damian↗

tbt-monitor

Platform for synchrotron BPM turn-by-turn (TbT) tune analysis across multiple Redis digitizers.

Steinkamp, Derek [Fermi National Accelerator Labor↗

Energy Exascale Earth System Model v2.1.0

First release of version 2.1 of the Energy Exascale Earth System Model. [ATM] The atmosphere component remains EAM. There are no major changes in the default configuration since 2.0. New features include: A semi-lagrangian tracer transport for theta-l dycore, a new algorithm for finding the tropopause, new RRM mesh configurations. Add and update SSP370 and SSP585 cases. Restore the FIDEAL case. [LAND] The land component is ELM. There are no major changes in the default configuration since 2.0. Several option features have been added including: implementation of topography-based subgrid structure (topounits) and accompanying parameterizations and atmospheric forcing downscaling methods; a new plant hydraulics scheme; two-way land-river hydrological coupling through the infiltration of floodplain water; an implementation of perennial crops; updates to the SNICAR-AD snow radiative transfer model; and implementation of soil erosion and sediment yield in ELM-Erosion. Each of these new changes is modular in design and can be turned on or off as the user specifies; they are currently being tested in different “BGC” configurations. [OCEAN] The ocean component remains MPAS-Ocean. Major change since version 2.0 include the addition of the Fox-Kemper et al. 2011 parameterization for submesocale eddies, a correction for barotropic thickness consistency that reduces divergence noise, and the addition of an ocean carbon conservation analysis member. [SEAICE] The sea-ice component remains MPAS-Seaice. Major changes since version 2.0 include: A correction to how shortwave parameters are interpolated in the snicar-ad 5-band radiation scheme, the addition of a sea ice carbon conservation analysis member, updates to the default sea ice biogeochemistry namelist parameters to be consistent with version 2.0 improvements to nitrogen cycling and a correction in the ice-ocean dissolved organic nitrogen coupling. [LAND ICE] The land-ice component remains MPAS-Albany-landIce (MALI). Major changes since 2.0 include an update to the MALI version and the Greenland mesh.[RIVER] The river model is MOSART. There are no major changes in the default configuration since 2.0. A major new optional feature is two-way river-ocean hydrological coupling between MOSART and MPAS-O. This change can be turned on or off as the user specifies, and is being tested in different configurations. [COUPLER] The coupler remains cpl7/MCT. Major changes since version 2.0 include: Carbon budget calculated when heat/water budgets active. Fix a bug in land-atm fluxes for tri-grid configurations. [OTHER] a small bug in the zenith angle calculation was fixed in the data models.

ECP↗

Monsoonal MCS Initiation, Rainfall, and Diurnal Gravity Waves over the Bay of Bengal: Observation and a Linear Model

Abstract Previous observational studies have indicated that mesoscale convective systems (MCSs) contribute the majority of precipitation over the Bay of Bengal (BoB) during the summer monsoon season, yet their initiation and propagation remain incompletely understood. To fill this knowledge gap, we conducted a comprehensive study using a combination of 20-yr satellite observations, MCS tracking, reanalysis data, and a theoretical linear model. Satellite observations reveal clear diurnal propagation signals of MCS initiation frequency and rainfall from the west coast of the BoB toward the central BoB, with the MCS rainfall propagating slightly slower than the MCS initiation frequency. Global reanalysis data indicate a strong association between the offshore-propagating MCS initiation frequency/rainfall and diurnal low-level wind perturbations, implying the potential role of gravity waves. To verify the hypothesis, we developed a 2D linear model that can be driven by realistic meteorological fields from reanalysis. The linear model realistically reproduces the characteristics of offshore-propagating diurnal wind perturbations. The wind perturbations, as well as the offshore propagation signals of MCS initiation frequency and rainfall, are associated with diurnal gravity waves emitted from the coastal regions, which in turn are caused by the diurnal land–sea thermal contrast. The ambient wind speed and vertical wind shear play crucial roles in modulating the timing, propagation, and amplitude of diurnal gravity waves. Using the linear model and satellite observations, we further show that the stronger monsoonal flows lead to faster offshore propagation of diurnal gravity waves, which subsequently control the offshore propagation signals of MCS initiation and rainfall. Significance Statement Rainfall over the Bay of Bengal (BoB) is primarily contributed by large and organized rainfall systems in the summer monsoon season. During this season, these systems are commonly observed over the east coast of India around midnight, the western BoB in the morning, and the central BoB in the afternoon. This eastward rainfall propagation is confirmed by observations, reanalysis data, and a theoretical model to have a strong association with atmospheric diurnal gravity waves. These waves are caused by land–sea thermal contrast and can trigger rainfall systems over the offshore regions. We also found that the diurnal gravity waves, as well as their triggered rainfall systems, can be greatly modulated by the large-scale monsoonal flows. All the above findings improve our understanding of diurnal rainfall cycle over the BoB and may contribute to the future improvement of rainfall forecast over the region.

Meteorology & Atmospheric Sciences↗

The impacts of horizontal resolution on the seasonally-dependent biases of the northeastern Pacific ITCZ in coupled climate models.

Double-ITCZ has puzzled climate model community for more than two decades. Here, we found that over the eastern Pacific, precipitation and sea surface temperature (SST) biases in the NCAR CESM1 are seasonally-dependent, with positive (negative) precipitation/SST biases during boreal summer/fall (winter/spring), although the easterly wind bias persists around the year. This seasonally-dependent bias of precipitation/SST is found to be caused by the failure of the model to reproduce the climatological seasonal wind reversal of North American monsoon. During winter/spring, the climatological easterly wind dominates, so the stronger wind speed in the model enhances the evaporation and lowers the SST. It is opposite when the climatological wind turns to westerly during summer/fall. The easterly wind bias also occurs in the atmospheric model when the observation SST is prescribed, suggesting it is of atmospheric origin. Further, the easterly wind bias is mainly evident in the lower troposphere and quite independent of time, implying the effect of complex and narrow-ranged Central American topography, which is not depicted well in the coarse model resolution. When the model resolution is doubled, both SST and precipitation are improved with the reduced easterly wind bias. During boreal spring, when ITCZ bias is most significant, the northern and southern ITCZ can be improved by 29% and 18.8% respectively in the higher resolution. Finally, we suggest that these seasonally-dependent biases over the eastern Pacific are quite universal among 37 CMIP5 coupled models, and the ongoing CMIP6 project will provide a valuable opportunity to examine whether the bias can be reduced by increasing model resolution.

Song, Fengfei↗

Uncertainty quantification in elastic constants of SiC f /SiC m tubular composites using global sensitivity analysis

Silicon carbide fiber and silicon carbide matrix (SiC f /SiC m ) tubes produced through the chemical vapor infiltration process have become a candidate cladding material in nuclear applications. The performance of this composite is influenced by many variables such as braiding angle, porosity, material properties, etc., which vary over a range of values due to the inherent fluctuations in the manufacturing process. In this study, the variability in elastic constants of SiC f /SiC m composite has been quantified through multiscale finite element (FE) simulations, variable screening, and high-fidelity surrogate modeling. The key variables dominantly affecting the elastic constants of SiC f /SiC m tubes were identified using global sensitivity analysis. A surrogate to the high-fidelity FE-based model was used in Monte Carlo simulations to generate a hundred thousand samples from which the uncertainty in elastic constants was assessed. It turned out that the coefficient of variation was less than 10%.

Materials Science↗

Multiscale and Multivariate Transportation System Visualization for Shopping District Traffic and Regional Traffic

In this paper, we present a suite of visualization techniques for sensor-based transportation system data at different scales to facilitate the exploration of interconnected traffic dynamics at intersections and highways. Additionally, these techniques are designed for analyzing multivariate traffic data from radar-based highway sensors and camera-based intersection sensors recording turn movements and vehicle speed, in the Chattanooga Metropolitan Area, with the capability of (a) revealing multiscale mobility patterns using different levels of data aggregation (e.g., individual sensor for microscale, multiple sensors along a corridor for mesoscale, and a larger number of sensors across the region for macroscale visualization) at different intervals (e.g., 5-min intervals, time of day, full day, and day-of-the-week), and (b) exploring the spatial variation of multiple traffic-related variables (e.g., volumes, speeds, turn movements, and traffic light colors) provided by the sensors. We close with a case study to demonstrate the effectiveness of our multiscale and multivariate visualization techniques. At microscale, we focused on intersection data from a shopping district around Shallowford Road in East Chattanooga. For mesoscale visualization, we studied the Shallowford Road corridor and an adjacent stretch of I-75. At macroscale, we included highway data from the Chattanooga Metropolitan Area. All visualizations were integrated into a web-based situational awareness tool to promote user access and interaction. At a minimum, each visualization provides the option for selecting dates for real-time (depending on sensor availability) and historical data, and additional information on hovering, though most provide more detailed information, including different views of the selected data, or interactive highlights.

33 ADVANCED PROPULSION SYSTEMS↗

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗