Search NASA⌕ Search

SEARCH · Search NASA

Results for “VASCULAR DISEASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

CT Guided Bone Biopsy Using a Battery Powered Intraosseous Device

Purpose: To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. Methods: Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacare, Shavano Park, TX, USA). Data of the 12 were compared to a historic cohort in whom the specimen were acquired using the classic Jamshidi Needle, as reference needle using manual force for biopsy. Results: Technical success was reached in 11 of 12 cases, indicated by central localisation of the needle within the target lesion. All specimen sampled were sufficient for histopathological workup. Compared to the historical cohort the time needed for biopsy decreased significantly from 13 {+-} 6 to 6 {+-} 4 min (P = 0.0001). Due to the shortened intervention time the radiation dose (CTDI) during CT-fluoroscopy was lowered significantly from 169 {+-} 87 to 111 {+-} 54 mGy Multiplication-Sign cm (P = 0.0001). Interventional radiologists were confident with the performance of the needle especially when using in sclerotic or osteoblastic lesions. Conclusion: The OBM is an attractive support for CT-fluoroscopy guided bone biopsy which is safe tool and compared to the classical approach using the Jamshidi needle leading to significantly reduced intervention time and radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Technique for Inferior Vena Cava Filter Extraction

Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neurointerventional Treatment in Acute Stroke. Whom to Treat? (Endovascular Treatment for Acute Stroke: Utility of THRIVE Score and HIAT Score for Patient Selection)

Purpose: Intra-arterial therapy (IAT) is used increasingly as a treatment option for acute stroke caused by central large vessel occlusions. Despite high rates of recanalization, the clinical outcome is highly variable. The authors evaluated the Houston IAT (HIAT) and the totaled health risks in vascular events (THRIVE) score, two predicting scores designed to identify patients likely to benefit from IAT. Methods: Fifty-two patients treated at the Stavanger University Hospital with IAT from May 2009 to June 2012 were included in this study. We combined the scores in an additional analysis. We also performed an additional analysis according to high age and evaluated the scores in respect of technical efficacy. Results: Fifty-two patients were evaluated by the THRIVE score and 51 by the HIAT score. We found a strong correlation between the level of predicted risk and the actual clinical outcome (THRIVE p = 0.002, HIAT p = 0.003). The correlations were limited to patients successfully recanalized and to patients <80 years. By combining the scores additional 14.3 % of the patients could be identified as poor candidates for IAT. Both scores were insufficient to identify patients with a good clinical outcome. Conclusions: Both scores showed a strong correlation to poor clinical outcome in patients <80 years. The specificity of the scores could be enhanced by combining them. Both scores were insufficient to identify patients with a good clinical outcome and showed no association to clinical outcome in patients aged {>=}80 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

Purpose: To evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center. Methods: We retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2. Results: Five consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %). Conclusion: Embolization for vEDS is a safe and effective method to manage life-threatening arterial rupture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term Outcomes of Percutaneous Venoplasty and Gianturco Stent Placement to Treat Obstruction of the Inferior Vena Cava Complicating Liver Transplantation

Purpose: Evaluation of long-term outcomes of venoplasty and Gianturco stents to treat inferior vena cava (IVC) obstruction after liver transplantation. Methods: We retrospectively analyzed records from 33 consecutive adult patients referred with the intent to treat suspected IVC obstruction after liver transplantation. Treatment was performed for occlusion or stenosis with a gradient exceeding 3 mmHg. The primary treatment was venoplasty and, if refractory, Gianturco stent placement. Recurrence prompted repeat venoplasty or stent placement. Results: Of the 33 patients, 25 (aged 46.9 ± 12.2 years) required treatment at a mean of 2.3 years (14 days to 20.3 years) after transplantation. For technically successful cases, primary treatment was venoplasty alone (14) or with stent placement (10). Technical success was 96 % (24 of 25) reflecting failure to cross one occlusion. Clinical success was 88 % (22 of 25) reflecting the technical failure and two that died of unrelated complications within 5 weeks. Cumulative primary patencies were 57.1 % at 6 months (n = 21) and 51.4 % at 1 (n = 10), 3 (n = 7), 5 (n = 6), and 7 (n = 5) years. Cumulative primary assisted patency was 95.2 % at 6 months (n = 21) and at 1 (n = 15), 3 (n = 9), 5 (n = 8), and 7 (n = 8) years. The 17 patients stented for refractory (n = 10) or recurrent (n = 7) stenosis had cumulative primary and primary assisted patencies of 86.0 and 100 %, respectively, from 6 months (n = 14) to 7 years (n = 3). No major complications occurred; one fractured stent was observed after 11.6 years. Conclusion: For IVC obstruction following liver transplantation, excellent long-term outcomes can be achieved by venoplasty and Gianturco stent placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Migrated Aortic Stent Graft Causing Erosive Spondylopathy

We report about a patient presenting with back pain 4 months after an uneventful endovascular implantation of an aortic stent graft. Computed tomography scan revealed a migration of the stent with consecutive endoleakage, kink formation, and movement of the stent toward the spine, which caused destruction of the aortic wall as well as vertebral necrosis. Explantation of the stent and replacement of the native aorta relieved the patient of his symptoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In the Lead Again Horizontal-Ellipsis [Journal of Cardiovascular and Interventional Radiology]

The 2013 ISI journal rankings are out and it is my pleasure to inform our readership that CVIR ranks 43/120 (2012: 46/118) journals in the field of radiology. The 2013 impact factor further improved to 2.138 (2012: 2.093). This means that Cardiovascular and Interventional Radiology again continues to be the highest ranked journal dedicated to the field of interventional radiology in 2013.This is mainly due to the great support we achieve by you as authors and readers of CVIR, your dedication to the profession, and your loyalty both to the journal and to CIRSE. For all of this, we owe you our thanks and respect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Visceral Aneurysm Using Multilayer Stent: Two-Year Follow-Up Results in Five Consecutive Patients

Purpose: The present study was performed to analyze the midterm results (five consecutive patients, 2-year follow-up) of the endovascular management of visceral artery aneurysms using the Cardiatis Multilayer Flow Modulator (CMFM) (Cardiatis, Isnes, Belgium), a self-expandable stent. Materials and Methods: From August 2009 to January 2011, we implanted five CMFMs in five patients (all men; mean age 73 years) to treat two common hepatic artery aneurysms, one celiac trunk aneurysm, one splenic artery aneurysm, and one superior mesenteric artery aneurysm (diameter 25-81 mm). The primary end point was technical success. The secondary end point was stent patency, absence of aneurysm rupture or reperfusion, and shrinking of the sac at 6-, 12-, and 24-month follow-up using computed tomography angiography. Follow-up ranged from 24 to 48 months (mean 31.2). Results: Technical success was achieved in all patients. Complete exclusion of the aneurysm with sac shrinking was achieved in two patients. Two stents became occluded at 6- and 24-month follow-up, respectively; both patients were asymptomatic and were not retreated. One patient developed sac reperfusion due to incomplete aneurysm exclusion. Conclusion: Long-term results in a wider population are needed to validate the effectiveness of the CMFM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transient Ischemic Rectitis as a Potential Complication after Prostatic Artery Embolization: Case Report and Review of the Literature

Prostatic artery embolization (PAE) is an alternative treatment for benign prostatic hyperplasia. Complications are primarily related to non-target embolization. We report a case of ischemic rectitis in a 76-year-old man with significant lower urinary tract symptoms due to benign prostatic hyperplasia, probably related to nontarget embolization. Magnetic resonance imaging revealed an 85.5-g prostate and urodynamic studies confirmed Inferior vesical obstruction. PAE was performed bilaterally. During the first 3 days of follow-up, a small amount of blood mixed in the stool was observed. Colonoscopy identified rectal ulcers at day 4, which had then disappeared by day 16 post PAE without treatment. PAE is a safe, effective procedure with a low complication rate, but interventionalists should be aware of the risk of rectal nontarget embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Isolated Calyx Mistaken for a Cyst: Inappropriately Performed Catheter-Directed Sclerotherapy and Safe Removal of the Catheter After Selective Embolization

We present a case of isolated calyx that was mistaken for a large cyst. A 47-year-old woman was referred for sclerotherapy of a large cystic lesion on her left kidney. Computed tomography (CT) and ultrasound showed that the cystic lesion was a large cyst. We noticed that the cystic lesion was not a typical simple cyst, even after two sessions of catheter-mediated sclerotherapy. Isolated calyx was presumed by medical history review and was confirmed by aspirated fluid analysis and far delayed-phase CT after intravenous contrast injection. We performed meticulous selective arterial embolization for an isolated calyx and inserted a catheter that could be removed without complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗