Spectroscopy and Photometry of Mars Trojans

Mars is the only terrestrial planet known to have co-orbiting Trojan asteroids. We have obtained visible and near-IR reflectance spectra of three of these objects: 5261 Eureka and 1998 VF31 in the L5 region and 1999 UJ7 in the LA region. We also obtained JHK spectrophotometry and a visible lightcurve for 5261 Eureka. The asteroid 5261 Eureka has a visible spectrum that is classified as Sr in the Bus taxonomy, and has infrared colors consistent with the A-class asteroids. The data for 1998 VF31 have a restricted wavelength range, but are most consistent with the Sr or Sa class, though we note a marginal consistency with the D class. We can rule out a C-class classification. 1999 UJ7 has an X-class or T-class spectrum, which is unlike that of the other two Mars Trojans. The photometric data for Eureka are limited, but we can constrain the period to longer than 5 hours (likely 5.5-6 hours) and lightcurve amplitude of at least 0.15 magnitude at this viewing geometry. The spectral differences among the Mars Trojans suggests that either they did not all form at their present solar distances or that they have not always been at their present sizes.

Rivkin, A. S.↗

Spectroscopy of small cometary particles

Knowledge of chemical composition derived from the spectroscopy of small cometary meteoroids when they enter the Earth's atmosphere at high velocity and become visible as meteors is briefly summarized. For statistically reliable results it is necessary to have a large number of observations and this requires the photography of relatively faint meteors, which are considerably more numerous than the bright fireballs. The improvement in observational techniques and cameras has made it possible to extend the range of spectrographic data from cometary particles of mass between a kilogram and a gram down to those of only 0.01 or 0.001 grams in mass. The corresponding increase in the number-value of the statistics was from less than 100 data points to several 1000.

Millman, P. M.↗

Spatial heterodyne spectroscopy - A novel interferometric technique for the FUV

The optical principles associated with spatial heterodyne spectroscopy (SHS) are described and the results of proof-of-concept tests performed in both the visible and the UV spectral regions are presented. A specific all-reflecting SHS configuration now being developed for high-resolution planetary Lyman-alpha studies is discussed. The expected performance of SHS systems is compared to that of conventional instrumentation in two cases: Venusian Ly-alpha measurements at high resolution from a sounding rocket and the velocity-resolved survey of the diffuse FUV interstellar medium emission from a Small Explorer class satellite.

Harlander, J.↗

X-ray spectroscopy of solar active regions and flares.

Review of some recent contributions of X-ray spectroscopy to knowledge about solar active regions and flares. As an example of the importance of X-ray spectroscopy, it is pointed out that, while there are no emission lines from highly ionized silicon in the visible spectrum, the XUV spectrum has emission lines from SiIX through SiXIV. Jordan's (1969) calculations of ionization equilibria for silicon and iron are illustrated by diagrams and discussed. The observation of SiXIV gives evidence for regions having electron temperatures from 5 to 20 million deg. The ability to record the corona against the disk of the sun has enabled Van Speybroeck et al. (1970) to identify many bright diffuse X-ray emitting regions with remnants of old active regions of the type giving rise to unipolar magnetic regions. The physical characteristics of the hot coronal plasma associated with chromospheric flares are outlined on the basis of current observations.

Neupert, W. M.↗

Passive optical and infrared meteorology

Applications of passive visible and infrared techniques to the study of meteorological parameters are presented. For the remote sensing of temperature and humidity profiles, infrared sounder improvements have proceeded with the narrow band-pass channels approach, and the partially scanned interferogram approach. Current and planned infrared and microwave sea-surface temperature sounders have an expected accuracy of approximately 2 K, and this can be improved by using three super window channels from the 3.7 micron window region, with narrow band passes away from principal water vapor absorption lines. Cloud data remote sensing is currently performed from satellites, and these visible and infrared images have been used to track weather patterns. In addition, a passive infrared correlation-spectroscopy technique has been proposed for wind measurements. Finally, these techniques have also been applied to monitor such parameters as the Solar Constant, aerosols, and minor gas constituents.

Chahine, M. T.↗

Views from EPOXI. Colors in Our Solar System as an Analog for Extrasolar Planets

With extrasolar planet detection becoming more common place, the frontiers of extrasolar planet science have moved beyond detection to the observations required to determine planetary properties. Once the existing observational challenges have been overcome, the first visible-light studies of extrasolar Earth-sized planets will likely employ filter photometry or low-resolution. spectroscopy to observe disk-integrated radiation from the unresolved planet. While spectroscopy of these targets is highly desirable, and provides the most robust form of characterization. S/N considerations presently limit spectroscopic measurements of extrasolar worlds. Broadband filter photometry will thus serve as a first line of characterization. In this paper we use Extrasolar Observation and Characterization (EPOCh) filter photometry of the Earth. Moon and Mars model spectra. and previous photometric and spectroscopic observations of a range the solar system planets. Titan, and Moon to explore the limitations of using color as a baseline for understanding extrasolar planets

Crow, Carolyn A.↗

The Near-Earth Encounter of Asteroid 308635 (2005 YU55): Thermal IR Observations

The near-Earth approach (0.00217 AU, or 0.845 lunar distances) of the C-type asteroid 308635 (2005 YU55) in November 2011 presented a rare opportunity for detailed observations of a low-albedo NEA in this size range. As part of a multi-telescope campaign to measure visible and infrared spectra and photometry, we obtained mid-infrared (approx. 8 to 22 micron) photometry and spectroscopy of 2005 YU55 using Michelle on the Gemini North telescope on UT November 9 and 10,2011. An extensive radar campaign together with optical light-curves established the rotation state of YU55. In addition, the radar imaging resulted in a shape model for the asteroid, detection of numerous boulders on its surface, and a preliminary estimate of its equatorial diameter at 380 +/- 20 m. In a preliminary analysis, applying the radar and lightcurve-derived parameters to a rough-surface thermophysical model fit to the Gemini/Michelle thermal emission photometry results in a thermal inertia range of approximately 500 to 1500 J/sq m/0.5s/K, with the low-thermal-inertia solution corresponding to the small end of the radar size range and vice versa. Updates to these results will be presented and modeling of the thermal contribution to the measured near-infrared spectra from Palomar/Triplespec and IRTF/SpeX will also be discussed.

Lim, Lucy F.↗

Intracavity Dye-Laser Absorption Spectroscopy (IDLAS) for application to planetary molecules

Time-resolved, quasi-continuous wave, intracavity dye-laser absorption spectroscopy is applied to the investigation of absolute absorption coefficients for vibrational-rotational overtone bands of water at visible wavelengths. Emphasis is placed on critical factors affecting detection sensitivity and data analysis. Typical generation-time dependent absorption spectra are given.

Lang, Todd M.↗

Excited State Chemistry in the Free Stream of the NASA IHF Arc Jet Facility Observed by Emission Spectroscopy

Spectroscopic measurements of non-equilibrium emission were made in the free stream of the 60 megawatts Interaction Heating Facility at NASA Ames Research Center. In the visible near infrared wavelength region, the most prominent emission was from molecular N2, and in the ultra violet region, the spectra were dominated by emission from molecular NO. The only atomic lines observed were those of copper (an erosion product of the electrodes). The bands of the 1st Positive system of N2 (if B is true then A is true) differed significantly from spectra computed spectra assuming only thermal excitation, suggesting overpopulation of the high vibrational states of the B state of N2. Populations of these high vibrational levels (peaking at v (sub upper) equals 13) of the N2 B state were determined by scaling simulated spectra; calculations were performed for each upper vibrational state separately. The experimental-theoretical procedure was repeated for several radial positions away from the nozzle axis to obtain spatial distributions of the upper state populations; rotational symmetry of the flow was assumed in simulations. The overpopulation of the high vibrational levels has been interpreted as the effect of inverse pre-dissociation of neutral atoms in the N2 A state, which populates the N2 B state through a level crossing process at v (sub upper) is greater than 10.

arc-jet testing↗

Water vapor resistance of plasma-polymerized coatings on potassium bromide windows

Plasma-polymerized tetrafluoroethylene (PPTFE) coated potassium bromide IR window are shown to possess better resistance to moisture than either ethylene or chlorotrifluoroethylene. The PPTFE-coated windows tolerated an upper limit relative humidity of about 80% at 297 K, without visible damage to either window or coating, over a period of 24 hours. Elemental analysis of the bulk, and photoelectron spectroscopy of the coating surface, showed that PPTFE coatings deposited downstream of the internal plasma reactor electrodes contained less atmospheric oxygen than coatings deposited between the electrodes; perhaps accounting for the improved moisture resistance.

Wydeven, T.↗

Frontiers for geological remote sensing from space; Geosat Workshop, 4th, Flagstaff, AZ, June 12-17, 1983, Report

Consideration is given to: the applications of near-infrared spectroscopy to geological reconnaissance and exploration from space; imaging systems for identifying the spectral properties of geological materials in the visible and near-infrared; and Thematic Mapper (TM) data analysis. Consideration is also given to descriptions of individual geological remote sensing systems, including: GEO-SPAS; SPOT; the Thermal Infrared Multispectral Scanner (TIMS); and the Shuttle Imaging Radars A and B (SIR-A and SIR-B). Additional topics include: the importance of geobotany in geological remote sensing; achromatic holographic stereograms from Landsat MSS data; and the availability and applications of NOAA's non-Landsat satellite data archive.

Henderson, F. B.↗

Smart focal-plane technology for micro-instruments and micro-rovers

It is inevitable that micro-instruments and micro-rovers for space exploration will contain one or more focal-plane arrays for imaging, spectroscopy, or navigation. In this paper, we explore the state-of-the-art in focal-plane technology for visible sensors. Also discussed is present research activity in advanced focal-plane technology with particular emphasis on the development of smart sensors. The paper concludes with a discussion of possible future directions for the advancement of the technology.

Fossum, Eric R.↗

Scanning Tunneling Optical Resonance Microscopy

Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically < 10 Hz) that the feedback circuit could respond, then the voltage applied to the piezoelectric tip-height actuator could be measured by use of a lock-in amplifier locked to the modulation (chopping) signal. However, at a high modulation frequency (typically in the kilohertz range or higher), the feedback circuit would be unable to respond. In this case, the photoenhanced portion of the tunneling current could be measured directly. For this purpose, the tunneling current would be passed through a precise resistor and the voltage drop would be measured by use of the lock-in amplifier.

Bailey, Sheila↗

Smart Focal-Plane Technology for Micro-Instruments and Micro-Rovers

It is inevitable that micro-instruments and micro-rovers for space exploration will contain one or more focal-plane arrays for imaging spectroscopy or navigation. In this paper, we explore the state-if-the-art in focal-plane technology for visible sensors. Also discussed is present research activity in advanced focal-plane technology with particular emphasis on the development of smart sensors. The paper concludes with a discussion of possible future directions for the advancement of the technology.

Fossum, Eric R.↗

Evaluating Diurnal Ozone Emissions: A Comparative Analysis of DSCOVR EPIC, PANDORA, and TOLNet Data for Space-Based Monitoring Assessment: A Case Study by ASDC

Stratospheric ozone occurs naturally in the upper atmosphere, forming a protective layer that shields us from the sun's harmful ultraviolet rays. Tropospheric ozone is not emitted directly into the air but is created by chemical reactions between nitrogen oxides (NOx) and volatile organic compounds (VOC). This reaction happens when pollutants emitted by cars, power plants, industrial boilers, refineries, chemical plants, and other sources chemically react in sunlight [1]. Therefore, increased levels of tropospheric ozone indicate the presence of pollutants in the air. While daily anthropogenic activity causes an increase of ground-level ozone, variation of stratospheric ozone changes happens much slower, so that variation of the total ozone column reflects the variation of the tropospheric column due to natural, e.g., wildfires and anthropogenic air pollution. Both total and tropospheric ozone column products are used in this study. The reflectance spectra measured by the Earth Polychromatic Imaging Camera (EPIC) instrument aboard the Deep Space Climate Observatory (DSCOVR) spacecraft are compared with a set of radiative transfer-derived lookup tables for the EPIC filter transmission functions and a wide range of ozone values to retrieve ozone with a maximum resolution of 18 km at the sub-satellite point [2]. EPIC provides total column ozone in level 2 and level 4 products and tropospheric column ozone in level 4 products. Both EPIC Ozone products [2] are available at the Atmospheric Science Data Center (ASDC) at NASA Langley Research Center [3, 4]. Pandora spectrometer instrument measures columnar amounts of trace gases in the atmosphere. These gases (O3, NO2, CH2O) absorb light from the sun at specific wavelengths in the ultraviolet-visible spectrum [5]. Using the theoretical solar spectrum as a reference, Pandora determines trace gas amounts using differential optical absorption spectroscopy (DOAS). Pandora ozone retrievals are available from the Pandonia Global Network [6]. Pandora data from North American major metropolitan areas, New York, NY, Washington DC, Los Angeles, CA, and Mexico City. Tropospheric Ozone Lidar Network (TOLNet) was established in 2012 to provide high spatiotemporal observations of tropospheric ozone to (1) better understand physical processes driving the ozone budget in various meteorological and environmental conditions and (2) validate the tropospheric ozone measurements of space-borne missions [7]. TOLNet data are available at ASDC [8]. While EPIC provides global coverage of ozone retrievals several times daily, temporal resolution may miss some features in daily ozone variations. Ground-based sensors such as Pandora spectrometers and TOLNet lidars provide better temporal resolution while missing continuous spatial coverage. The forthcoming ozone retrieval from the TEMPO mission [9] will provide better spatial and temporal coverage of air quality (including ozone) over North America. This study investigates whether EPIC ozone products can detect diurnal air quality variations and compare ozone temporal development with retrieval by ground-based instruments.

diurnal ozone emissions, DSCOVR EPIC, PANDORA, spa↗

EUV astronomical spectroscopy with CCD detectors

The applicability of CCD detectors to astronomical extreme ultraviolet (EUV) spectroscopy (100-1250 A) is discussed. The advantages of CCDs in this spectral region include internal electron yield, the potential for very high quantum efficiency (about 50-90 percent), and broad wavelength response. Visible light suppression is achieved by a combination of low grating scattering, greater than unity electron yield in the EUV, and various filter techniques. For the current generation of CCDs, detection of only a few EUV photons will rapidly overwhelm the read noise; thus, for all practical S/N ratios used in astronomical spectroscopy, read noise will be negligible compared to the poisson statistics of the detected photons. A model based on experimental data for the quantum efficiency and electron yield of CCDs in the EUV is discussed.

Stern, R. A.↗

High-resolution spectroscopy with the multi-anode microchannel array detector systems

The results of a series of high-resolution spectroscopic observations undertaken with a linear (1 x 1024)-pixel visible-light Multi-Anode Microchannel Array (MAMA) detector on the Coudespectrograph of the 2.2-meter telescope at the Mauna Kea Observatory and on the vacuum spectrograph of the McMath Solar telescope at the Kitt Peak National Observatory are described. In addition, the two-dimensional MAMA detector systems with (16 x 1024)-pixel, (24 x 1024)-pixel, and (256 x 1024)-pixel formats which are now being readied for use in a series of ground-based, balloon, and sounding-rocket observing programs are briefly described.

Timothy, J. G.↗