Search NASA⌕ Search

SEARCH · Search NASA

Results for “ZONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The hidden dynamics of relativistic electrons (0.7-1.5 MeV) in the inner zone and slot region

We present measurements of relativistic electrons (0.7–1.5 MeV) in the inner zone and slot region obtained by the Magnetic Electron and Ion Spectrometer (MagEIS) instrument on Van Allen Probes. The data presented are corrected for background contamination, which is primarily due to inner-belt protons in these low-L regions. We find that ~1 MeV electrons were transported into the inner zone following the two largest geomagnetic storms of the Van Allen Probes era to date, the March and June 2015 events. As ~1 MeV electrons were not observed in Van Allen Probes data in the inner zone prior to these two events, the injections created a new inner belt that persisted for at least 1.5 years. In contrast, we find that electrons injected into the slot region decay on much faster timescales, approximately tens of days. Furthermore, we find no evidence of >1.5 MeV electrons in the inner zone during the entire time interval considered (April 2013 through September 2016). The energies we examine thus span a transition range in the steeply falling inner zone electron spectrum, where modest intensities are observed at 0.7 MeV, and no electrons are observed at 1.5 MeV. To validate the results obtained from the background corrected flux measurements, we also present detailed pulse-height spectra from individual MagEIS detectors. These measurements confirm our results and also reveal low-intensity inner zone and slot region electrons that are not captured in the standard background corrected data product. Lastly, we briefly discuss efforts to refine the upper limit of inner zone MeV electron flux obtained in earlier work.

58 GEOSCIENCES↗

Dynamic Model of Basic Oxygen Steelmaking Process Based on Multi-zone Reaction Kinetics: Model Derivation and Validation

A multi-zone kinetic model coupled with a dynamic slag generation model was developed for the simulation of hot metal and slag composition during the basic oxygen furnace (BOF) operation. The three reaction zones (i) jet impact zone, (ii) slag–bulk metal zone, (iii) slag–metal–gas emulsion zone were considered for the calculation of overall refining kinetics. In the rate equations, the transient rate parameters were mathematically described as a function of process variables. A micro and macroscopic rate calculation methodology (micro-kinetics and macro-kinetics) were developed to estimate the total refining contributed by the recirculating metal droplets through the slag–metal emulsion zone. The micro-kinetics involves developing the rate equation for individual droplets in the emulsion. The mathematical models for the size distribution of initial droplets, kinetics of simultaneous refining of elements, the residence time in the emulsion, and dynamic interfacial area change were established in the micro-kinetic model. In the macro-kinetics calculation, a droplet generation model was employed and the total amount of refining by emulsion was calculated by summing the refining from the entire population of returning droplets. A dynamic Fe{sub t}O generation model based on oxygen mass balance was developed and coupled with the multi-zone kinetic model. The effect of post-combustion on the evolution of slag and metal composition was investigated. The model was applied to a 200-ton top blowing converter and the simulated value of metal and slag was found to be in good agreement with the measured data. The post-combustion ratio was found to be an important factor in controlling Fe{sub t}O content in the slag and the kinetics of Mn and P in a BOF process.

36 MATERIALS SCIENCE↗

Study of seismic diffractions caused by a fracture zone at In Salah carbon dioxide storage project

The In Salah CO 2 storage project in Algeria has injected over 3 million tonnes of carbon dioxide into a water filled tight sand formation. Interferometric Synthetic Aperture Radar (InSAR) range change data revealed a double lobbed pattern of deformation that has been modeled as the opening of a sub-vertical fracture, or damage, zone. The location and geometry of the linear feature were subsequently verified using a seismic reflection survey. The elastic properties of the fracture zone, including anisotropic Poisson ratio ( ν ), Young's ( E ) and shear ( G ) moduli, were estimated from coupled geomechanical and hydrological modeling of surface deformation and pressure variations in the injection well. The elastic moduli reflect the fracture properties after CO 2 flow through the fracture zone. Thus, the seismic signature of the fracture zone could be used for monitoring the CO 2 plume. Using the estimated fracture model, we built two and three dimensional models consisting of an anisotropic fracture zone embedded within an isotropic background. Finite-difference modeling of seismic shot gathers allows us to estimate the effects of scattering from the fracture zone, potentially further constraining the geomechanical model. From the seismic modeling results, we find diffracted waves, induced by the fracture zone, which behave similar to point source diffractions. This modeling is intended to guide a search for diffraction events in the 3D surface seismic field data. The modeling results indicate that using the moduli estimated from geomechanical modeling, fracture scattered events would be 100 times lower amplitude than the interface reflections, and thus would be hard to detect. While diffracted waves are observed in the field data, which may imply the need for revision of the fracture model, including shape and elastic moduli, we are not able to match the field observation with our modeled events. This article presents a frontier study on the integration of geomechanical and geophysical methods at the In Salah site as a means to test the estimate of the subsurface CO 2 flooded fracture properties.

58 GEOSCIENCES↗

Impact of nonaqueous phase liquid (NAPL) source zone architecture on mass removal mechanisms in strongly layered heterogeneous porous media during soil vapor extraction

An existing multiphase flow simulator was modified in order to determine the effects of four mechanisms on NAPL mass removal in a strongly layered heterogeneous vadose zone during soil vapor extraction (SVE): a) NAPL flow, b) diffusion and dispersion from low permeability zones, c) slow desorption from sediment grains, and d) rate-limited dissolution of trapped NAPL. The impact of water and NAPL saturation distribution, NAPL type (i.e., free, residual, or trapped) distribution, and spatial heterogeneity of the permeability field on these mechanisms were evaluated. Two different initial source zone architectures (one with and one without trapped NAPL) were considered and these architectures were used to evaluate seven different SVE scenarios. For all runs, slow diffusion from low permeability zones that gas flow bypassed was a dominant factor for diminished SVE effectiveness at later times. This effect was more significant at high water saturation due to the decrease of gas-phase relative permeability. Transverse dispersion contributed to fast NAPL mass removal from the low permeability layer in both source zone architectures, but longitudinal dispersion did not affect overall mass removal time. Both slow desorption from sediment grains and rate-limited mass transfer from trapped NAPL only marginally affected removal times. However, mass transfer from trapped NAPL did affect mass removal at late time, as well as the NAPL distribution. NAPL flow from low to high permeability zones contributed to faster mass removal from the low permeability layer, and this effect increased when water infiltration was eliminated. These simulations indicate that if trapped NAPL exists in heterogeneous porous media, mass transfer can be improved by delivering gas directly to zones with trapped NAPL and by lowering the water content, which increases the gas relative permeability and changes trapped NAPL to free NAPL.

54 ENVIRONMENTAL SCIENCES↗

Zoned near-zero refractive index fishnet lens antenna: Steering millimeter waves

A zoned fishnet metamaterial lens is designed, fabricated, and experimentally demonstrated at millimeter wavelengths to work as a negative near-zero refractive index lens suitable for compact lens antenna configurations. At the design frequency f = 56.7 GHz (λ{sub 0} = 5.29 mm), the zoned fishnet metamaterial lens, designed to have a focal length FL = 9λ{sub 0}, exhibits a refractive index n = −0.25. The focusing performance of the diffractive optical element is briefly compared with that of a non-zoned fishnet metamaterial lens and an isotropic homogeneous zoned lens made of a material with the same refractive index. Experimental and numerically-computed radiation diagrams of the fabricated zoned lens are presented and compared in detail with that of a simulated non-zoned lens. Simulation and experimental results are in good agreement, demonstrating an enhancement generated by the zoned lens of 10.7 dB, corresponding to a gain of 12.26 dB. Moreover, beam steering capability of the structure by shifting the feeder on the xz-plane is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Convective instability of solidification with a phase transition zone

The morphological instability of solidification is analytically studied in the presence of an anisotropic and heterogeneous phase transition zone with allowance for a liquid flow and convective heat-andmass transfer in this two-phase zone. The mechanism of breaking the stability of solidification is considered; it consists in a convective heat and impurity transfer during a liquid flow along channels in the phase transition zone. The morphological instability is subjected to linear analysis with allowance for a liquid flow in the liquid phase of the system, impurity diffusion in the two-phase zone, and the dependence of the transfer coefficients on the phase composition. The perturbation evolution parameter is determined for an anisotropic and heterogeneous two-phase zone, and neutral stability curves of the process are obtained. It is shown that taking into account impurity diffusion and an increase in the heterogeneity of the phase transition zone broaden the instability region and that a decrease in the anisotropy narrows this region. A new criterion of convective morphological instability of solidification with a two-phase zone is found, and it substantially broadens the instability region when the liquid flow velocity increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-zone modelling of partially premixed low-temperature combustion in pilot-ignited natural-gas engines

Detailed results from a multi-zone phenomenological simulation of partially premixed advanced-injection low-pilot-ignited natural-gas low-temperature combustion are presented with a focus on early injection timings (the beginning of (pilot) injection (BOI)) and very small diesel quantities (2-3 per cent of total fuel energy). Combining several aspects of diesel and spark ignition engine combustion models, the closed-cycle simulation accounted for diesel autoignition, diesel spray combustion, and natural-gas combustion by premixed turbulent flame propagation. The cylinder contents were divided into an unburned zone, several pilot fuel zones (or 'packets') that modelled diesel evaporation and ignition, a flame zone for natural-gas combustion, and a burned zone. The simulation predicted the onset of ignition, cylinder pressures, and heat release rate profiles satisfactorily over a wide range of BOIs (20-60° before top dead centre (before TDC)) but especially well at early BOIs. Strong coupling was observed between pilot spray combustion in the packets and premixed turbulent combustion in the flame zone and, therefore, the number of ignition centres (packets) profoundly affected flame combustion. The highest local peak temperatures (greater than 2000 K) were observed in the packets, while the flame zone was much cooler (about 1650 K), indicating that pilot diesel spray combustion is probably the dominant source of engine-out emissions of nitrogen oxide (NO x ). Further, the 60° before TDC BOI yielded the lowest average peak packet temperatures (about 1720 K) compared with the 20° before TDC BOI (about 2480 K) and 40° before TDC BOI (about 2700 K). These trends support experimental NO x trends, which showed the lowest NO x emissions for the 60°, 20°, and 40° before TDC BOIs in that order. Parametric studies showed that increasing the intake charge temperature, pilot quantity, and natural-gas equivalence ratio all led to higher peak heat release rates and hotter packets but the pilot quantity and intake temperature affected the potential for NO x formation to a greater extent.

33 ADVANCED PROPULSION SYSTEMS↗

Vadose Zone Model for B-3A/B Pond for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort; carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP) simulator officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain. The Hanford Site Central Plateau was subdivided into 26 individual vadose zone models, with 13 in the 200 East Area and 13 in the 200 West Area. Waste sites that have a completed performance assessment (PA) or past-leak analysis were not included as sources of radionuclides. Instead the vadose zone to groundwater transfer rates of the Environmental Restoration Disposal Facility, Integrated Disposal Facility, US Ecology, and Waste Management Area C (WMA C) PAs and the past-leak analysis for WMA C were used as direct input to the P2R model. Each of the vadose zone models is documented in separate environmental calculation files (ECFs). This ECF describes the B-3A/B Ponds model. The scope of this ECF is to document the development and results of the B-3 A/B Ponds vadose zone model. CP-63515, Model Package Report: Central Plateau Vadose Zone Models, describes the approach, assumptions, process of determining the number of models required and domain of each model, input data, and processing common to all the models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for SALDS for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP) is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain. The Hanford Site Central Plateau was subdivided into 26 individual vadose zone models, with 13 in the 200 East Area and 13 in the 200 West Area. Waste sites that have a completed performance assessment (PA) or past-leak analysis were not included as sources of radionuclides. Instead the vadose zone to groundwater transfer rates of the Environmental Restoration Disposal Facility, Integrated Disposal Facility, US Ecology, and Waste Management Area C (WMA C) PAs and the past-leak analysis for WMA C were used as direct input to the P2R model. Each of the vadose zone models is documented in separate environmental calculation files (ECFs). This ECF describes the State-Approved Land Disposal Site (SALDS) model. The scope of this ECF is to document the development and results of the SALDS vadose zone model. CP-63515, Model Package Report: Central Plateau Vadose Zone Models, describes the approach, assumptions, process of determining the number of models required and domain of each model, input data, and processing common to all the models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating Vadose Zone Flow Properties at the 100 K-East Soil Flushing Site Using ERT Monitoring Data: 2023 Interim Report - 100 KE Soil Property Estimation

In situ soil flushing is being using at the Hanford 100 K-East (100 KE) area to transport mobile chromium contamination in the vadose zone to the water table, where it can be collected and treat through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. In practice, it is infeasible to comprehensively monitor which regions of the vadose zone are being infiltrated through direct sampling of pore water. Consequently, there can be significant uncertainty about which regions of the subsurface have been treated, especially if hydrogeologic conditions are favorable for the development of unstable flows and preferred flow pathways through the vadose zone (Jarvis, Koestel, and Larsbo 2016). Current approaches for quantitative monitoring of soil flushing performance rely on contaminant concentration measurements collected from extractions wells. There is no quantitative information on the volume of flush water delivered to targeted regions of the vadose zone at the Hanford Site, leading to significant uncertainty regarding source term removal and long-term impacts to groundwater. If the subsurface hydrogeologic properties at the 100 KE Area were adequately known, qualitative metrics of soil flushing performance could be simulated, thereby negating expenses required to obtain quantitative performance information through borehole drilling/sampling. However, estimating in situ hydrogeologic properties has long proven elusive, due primarily to a lack of sufficient information to constrain heterogeneous property estimates to a useful degree of certainty. Estimating vadose zone hydrogeologic properties is particularly challenging due the dependence of hydraulic conductivity on saturation. This report describes progress toward a first-of-its-kind demonstration using surface time-lapse 3D electrical resistivity tomography (ERT) monitoring data to estimate the hydrogeologic properties that control flush water transport at the 100 KE soil flushing site. The ultimate objective is (1) to verify sufficient information exists in the ERT monitoring data to adequately resolve vadose zone hydraulic properties, and (2) generate a “digital twin” (i.e., a numerical simulator) that can be used to simulate the amount of flush water that has been delivered to each targeted region of the vadose zone, and thereby assess the efficacy of flush water delivery. Resulting performance estimates can be used in leu of comprehensive borehole drilling and direct sampling (or wellbore logging) that would otherwise be required to obtain the same information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Basis for Evaluating Surface Barriers to Protect Groundwater from Deep Vadose Zone Contamination

This document presents a strategy for evaluating the effectiveness of surface barriers for site-specific deep vadose zone remediation. The strategy provides a technically defensible approach to determine the depth to which a surface barrier can effectively isolate contaminants in the vadose at a specific site as a function of subsurface properties, contaminant distribution, barrier design, and infiltration control performance. The strategy also provides an assessment of additional data and information needs with respect to surface barrier performance for deep vadose zone applications. The strategy addresses the linkage between surface barriers and deep vadose zone in situ remediation activities, monitoring issues, and emerging science, technology, and regulatory objectives. In short, the report documents the existing knowledge base, identifies knowledge needs (based on data gaps), and suggests tasks whose outcomes will address those knowledge needs. More important, the report serves as a starting point to engage the regulator and stakeholder community on the viability of deploying surface barriers for deep vadose zone contamination. As that engagement unfolds, a systematic methodology can be formalized and instituted. The strategy is focused on deep vadose zone contamination and the methods needed to determine the impact to groundwater from those deep vadose zone contaminants. Processes that affect surface barrier performance, recharge in the areas surrounding the surface barrier, and the near-surface vadose zone beneath the barrier are acknowledged but are not addressed by this strategy. In addition, the collection of site-specific data on contaminant distribution and geologic structure and properties are programmatic responsibilities and are not provided by this strategy.

58 GEOSCIENCES↗

Beaufort Sea ice zones as delineated by microwave imagery

Microwave and infrared data were obtained from a research aircraft over the Beaufort Sea ice from the shoreline of Harrison Bay northward to a latitude of almost 81 deg N. The data acquired were compared with microwave data obtained on the surface at an approximate position of 75 deg N, 150 deg W. Over this north-south transect of the polar ice canopy it was discovered that the sea ice could be divided into five distinct zones. The shorefast sea ice was found to consist uniformly of first-year sea ice. The second zone was found to be a mixture of first-year sea ice, medium size multiyear floes, and many recently refrozen leads, polynyas, and open water; considerable shearing activity was evident in this zone. The third zone was a mixture of first-year and multiyear sea ice which had a uniform microwave signature. The fourth zone was found to be a mixture of first-year sea ice and medium-to-large size multiyear floes which was similar in composition to the second zone. The fifth zone was almost exclusively multiyear ice extending to the North Pole.

Campbell, W. J.↗

On the structure of the solar transition zone and lower corona

Recent observations of the solar transition zone and corona obtained primarily from NRL spectrographs on Skylab are summarized and used to examine the structure of the transition zone. The transition zone is revealed to be more inhomogeneous than is apparent from spectroheliograms with spatial resolution of about 3 arcsec. Transition-zone emission appears to arise in spicularlike structures. The effective area covered by the emitting structures at lower transition-zone temperatures (about 100,000 K) is only about 1% of the total surface area of the sun. The transition zone is highly inhomogeneous even over cell interior regions, where fluctuations in brightness by factors of 25 can occur. It is shown that homogeneous coronal models are not valid for the inner corona. Most of the higher-density inner corona is concentrated into looplike structures that extend down to the white-light limb. These structures are unrelated to the spicular-type structures that produce most of the transition-zone emission.

Feldman, U.↗

Diffusive modification of primary zoning in olivine cores in Angrite LEW 87051

Angrite LEW 87051 consists of large olivine crystals set in a fine-grained groundmass that clearly represents a crystallized melt. A few olivines contain Ca-poor, Cr-rich cores that crystallized from a very different melt than the outer part of the crystals constituting the majority of olivine in LEW 87051. We evaluate a model in which the cores formed through fractional crystallization of one melt, then were incorporated into a different melt as xenocrysts, whereupon the original zoning patterns were modified by diffusion. Using a similar approach, we calculate zoning patterns for the cores that would result from perfect fractional crystallization, compare them with the observed zoning, and determine whether the differences could result from diffusive modification consistent with known diffusion rates for Ca, Mn, and Cr. Using distribution coefficients from the 1400 C, IW + 1 experiments, we computed CaO, Cr2O3, and MnO abundances in the hypothetical parent melt by inverting the olivine at the centers of the cores. We further assumed that the primary zoning profile for CaO is essentially unmodified, because the diffusion rate of Ca in olivine is slow. We carried out the fractional crystallization calculation until the calculated Ca content was that observed at break in zoning profiles at the outer edge of the core. We then normalized the distance of this calculated profile to the length of the observed profile in the olivine core and calculated profiles for MnO and Cr2O3. The CaO zoning profile agrees well with the observed profile. The observed MnO profile is slightly higher than the calculated profile near the edge. Diffusion calculations indicate that reversal of the general trend of primary zoning through diffusion would require that diffusion of Cr is 5-10x faster than that of Mn.

Mikouchi, T.↗

Role of Vibration-Induced Streaming in Float-Zone Crystal Growth

This presentation will examine in detail the role of vibration-induced streaming flow in the context of float-zone crystal growth. It is very well known that during float-zone materials processing, the naturally occurring temperature gradients along the zone surface impose a thermocapillary flow in the zone. Under certain processing conditions, the thermocapillary flow can also become nonsteady (oscillatory). The presence of thermocapillary flow is detrimental to crystal quality, for it can promote non-uniform dopant distribution and crystal striations. To null this effect we have imposed a counter streaming flow in the zone, via end-wall vibration. This technique has been adapted to float-zone processing of Sodium Nitrate-Barium Nitrate eutectic alloys, under both steady and nonsteady thermocapillary flow conditions. The beneficial effects of counter streaming flow have been clearly brought out through the before and after comparisons of the crystal microstructure. In addition, we are also examining the theoretical underpinnings of the balancing of thermocapillary flows with vibration-driven counter flows in float-zones.

Anilkumar, A. V.↗

Role of Vibration-Induced Streaming in Float-Zone Crystal Growth

This presentation will examine in detail the role of vibration-induced streaming flow in the context of float-zone crystal growth. It is very well known that during float-zone materials processing, the naturally occurring temperature gradients along the zone surface impose a thermocapillary flow in the zone. Under certain processing conditions, the thermocapillary flow can also become nonsteady (oscillatory). The presence of thermocapillary flow is detrimental to crystal quality, for it can promote non-uniform dopant distribution and crystal striations. To null this effect we have imposed a counter streaming flow in the zone, via end-wall vibration. This technique has been adapted to float-zone processing of Sodium Nitrate-Barium Nitrate eutectic alloys, under both steady and nonsteady thermocapillary flow conditions. The beneficial effects of counter streaming flow have been clearly brought out through the before and after comparisons of the crystal microstructure. In addition, we are also examining the theoretical underpinnings of the balancing of thermocapillary flows with vibration-driven counter flows in float-zones.

Anikumar, A. V.↗

The locations and amounts of endogenous ions and elements in the cap and elongating zone of horizontally oriented roots of Zea mays L.: an electron-probe EDS study

We used quantitative electron-probe energy-dispersive x-ray microanalysis to localize endogenous Na, Cl, K, P, S, Mg and Ca in cryofixed and freeze-dried cryosections of the cap (i.e. the putative site of graviperception) and elongating zone (i.e. site of gravicurvature) of horizontally oriented roots of Zea mays. Ca, Na, Cl, K and Mg accumulate along the lower side of caps of horizontally oriented roots. The most dramatic asymmetries of these ions occur in the apoplast, especially the mucilage. We could not detect any significant differences in the concentrations of these ions in the central cytoplasm of columella cells along the upper and lower sides of caps of horizontally-oriented roots. However, the increased amounts of Na, Cl, K and Mg in the longitudinal walls of columella cells along the lower side of the cap suggest that these ions may move down through the columella tissue of horizontally-oriented roots. Ca also accumulates (largely in the mucilage) along the lower side of the elongating zone of horizontally-oriented roots, while Na, P, Cl and K tend to accumulate along the upper side of the elongating zone. Of these ions, only K increases in concentration in the cytoplasm and longitudinal walls of cortical cells in the upper vs lower sides of the elongating zone. These results indicate that (1) gravity-induced asymmetries of ions differ significantly in the cap and elongating zone of graviresponding roots, (2) Ca accumulates along the lower side of the cap and elongating zone of graviresponding roots, (3) increased growth of the upper side of the elongating zone of horizontally-oriented roots correlates positively with increased amounts of K in the cytoplasm and longitudinal walls of cortical cells, and (4) the apoplast (especially the mucilage) may be an important component of the pathway via which ions move in graviresponding rots of Zea mays. These results are discussed relative to mechanisms for graviperception and gravicurvature of roots.

NASA Program Space Biology↗

Contactless heater floating zone refining and crystal growth

Floating zone refining or crystal growth is carried out by providing rapid relative rotation of a feed rod and finish rod while providing heat to the junction between the two rods so that significant forced convection occurs in the melt zone between the two rods. The forced convection distributes heat in the melt zone to allow the rods to be melted through with a much shorter melt zone length than possible utilizing conventional floating zone processes. One of the rods can be rotated with respect to the other, or both rods can be counter-rotated, with typical relative rotational speeds of the rods ranging from 200 revolutions per minute (RPM) to 400 RPM or greater. Zone refining or crystal growth is carried out by traversing the melt zone through the feed rod.

Kou, Sindo↗