Search NASA⌕ Search

SEARCH · Search NASA

Results for “active source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Radiation Imaging with Event Camera

Neuromorphic or event-based imaging is a new, commercially available sensor technology inspired by how the human eye works. Instead of measuring frames at a fixed rate, the camera measures changes in pixel intensity asynchronously. This difference in readout architecture results in a high dynamic range and low latency. Event-based cameras have been used in a variety of applications, including object tracking, navigation, and lidar technologies. However, event-based cameras have not been adequately researched for their ability to image high-energy particles. This report explores the use of an event camera for imaging alpha, beta, and X-rays particles, when coupled with scintillator screens to convert high-energy particles into visible light. Methods to process event data were developed and are presented here, along with the results. The event camera can measure alpha and beta particles with comparable performance to that of a conventional camera. Event cameras can also image higher-activity sources and offer the possibility of discriminating particle interaction types on the basis of timing differences, which typical cameras cannot do. Additionally, event cameras can image objects with an X-ray source when the source strength dynamically changes but does not create a high-contrast image during static X-ray measurement.

47 OTHER INSTRUMENTATION↗

Borehole Seismic Monitoring at Otway Using the Naylor-1 Instrument String

The Naylor-1 monitoring completion, a unique and innovative instrumentation package, was designed and fabricated in FY 2007 at Berkeley Laboratory. Tom Daley, Barry Freifeld and Duo Wang (all from Berkeley Lab) were on site at the Otway Project between September 26 and October 14, 2007, working with CO2CRC and their subcontractors, AGR Asia Pacific and Eastern Well Services to complete Naylor-1 and initiate baseline data collection. Figure 1 shows a schematic of Naylor-1's sensor layout. There are three U-tube geochemical samplers, with one located near the top of the residual CH{sub 4} gas cap and two located beneath the gas-water contact. The 21 geophones are used for performing three distinct seismic measurements, high resolution travel time (HRTT), walkaway vertical seismic profiling (WVSP), and microseismic monitoring. These activities are separated in to active source seismic and microseismic monitoring, and will be described separately.

54 ENVIRONMENTAL SCIENCES↗

3D Imaging of Geothermal Faults from a Vertical DAS Fiber at Brady Hot Spring, NV USA

In March 2016, arguably the most ambitious 4D (3D space + over time) active-source seismic survey for geothermal exploration in the U.S. was acquired at Brady Natural Laboratory, outside Fernley, Nevada. The four-week experiment included 191 vibroseis source locations, and approximately 130 m of distributed acoustic sensing (DAS) in a vertical well, located at the southern end of the survey area. The imaging of the geothermal faults is done with reverse time migration of the DAS data for both P-P and P-S events in order to generate 3D models of reflectivity, which can identify subsurface fault locations. Three scenarios of receiver data are explored to investigate the reliability of the reflectivity models obtained: (1) Migration of synthetic P-P and P-S DAS data, (2) migration of the observed field DAS data and (3) migration of pure random noise to better assess the validity of our results. The comparisons of the 3D reflectivity models from these three scenarios confirm that sections of three known faults at Brady produce reflected energy observed by the DAS. Two faults that are imaged are ~1 km away from the DAS well; one of these faults (middle west-dipping) is well-constructed for over 400 m along the fault’s strike, and 300 m in depth. These results confirm that the DAS data, together with an imaging engine such as reverse time migration, can be used to position important geothermal features such as faults.

10 SYNTHETIC FUELS↗

Critical Height of the Torus Instability in Two-ribbon Solar Flares

We studied the background field for 60 two-ribbon flares of M-and-above classes during 2011–2015. These flares are categorized into two groups, i.e., eruptive and confined flares, based on whether a flare is associated with a coronal mass ejection or not. The background field of source active regions is approximated by a potential field extrapolated from the B {sub z} component of vector magnetograms provided by the Helioseismic and Magnetic Imager. We calculated the decay index n of the background field above the flaring polarity inversion line, and defined a critical height h {sub crit} corresponding to the theoretical threshold ( n {sub crit} = 1.5) of the torus instability. We found that h {sub crit} is approximately half of the distance between the centroids of opposite polarities in active regions and that the distribution of h {sub crit} is bimodal: it is significantly higher for confined flares than for eruptive ones. The decay index increases monotonously with increasing height for 86% (84%) of the eruptive (confined) flares but displays a saddle-like profile for the rest, 14% (16%), which are found exclusively in active regions of multipolar field configuration. Moreover, n at the saddle bottom is significantly smaller in confined flares than that in eruptive ones. These results highlight the critical role of background field in regulating the eruptive behavior of two-ribbon flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Intercomparison of open-path trace gas measurements with two dual-frequency-comb spectrometers

Abstract. We present the first quantitative intercomparison between two open-path dual-comb spectroscopy (DCS) instruments which were operated across adjacent 2 km open-air paths over a 2-week period. We used DCS to measure the atmospheric absorption spectrum in the near infrared from 6023 to 6376 cm−1 (1568 to 1660 nm), corresponding to a 355 cm−1 bandwidth, at 0.0067 cm−1 sample spacing. The measured absorption spectra agree with each other to within 5 × 10−4 in absorbance without any external calibration of either instrument. The absorption spectra are fit to retrieve path-integrated concentrations for carbon dioxide (CO2), methane (CH4), water (H2O), and deuterated water (HDO). The retrieved dry mole fractions agree to 0.14 % (0.57 ppm) for CO2, 0.35 % (7 ppb) for CH4, and 0.40 % (36 ppm) for H2O at ∼ 30 s integration time over the 2-week measurement campaign, which included 24 °C outdoor temperature variations and periods of strong atmospheric turbulence. This agreement is at least an order of magnitude better than conventional active-source open-path instrument intercomparisons and is particularly relevant to future regional flux measurements as it allows accurate comparisons of open-path DCS data across locations and time. We additionally compare the open-path DCS retrievals to a World Meteorological Organization (WMO)-calibrated cavity ring-down point sensor located along the path with good agreement. Short-term and long-term differences between the open-path DCS and point sensor are attributed, respectively, to spatial sampling discrepancies and to inaccuracies in the current spectral database used to fit the DCS data. Finally, the 2-week measurement campaign yields diurnal cycles of CO2 and CH4 that are consistent with the presence of local sources of CO2 and absence of local sources of CH4.

Waxman, Eleanor M.↗

A survey of imaging systems for materials and objects in containers

Radiation imaging can be useful to evaluate the contents of containers; Passive imaging i.e., gamma sources, neutron sources, hydrogen near to a neutron source. Active imaging i.e., Transmission radiography shows high density material; Neutron coincidences indicate fissionable material; Time of Flight and die-away time are important. These technologies may be most useful in confirming ABSENCE of an item.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EGS Collab Project: Status, Tests, and Data

The EGS (Enhanced Geothermal Systems) Collab project is performing stimulation and flow experiments in highly-monitored and well-characterized intermediate-scale (approximately10 to 20 meter) field test beds at a depth of approximately 1,500 meters in the Sanford Underground Research Facility (SURF) in the Black Hills of South Dakota. Our fracture stimulation and interwell flow tests are performed to better understand processes that control formation of effective subsurface heat exchangers that are critical to the development and success of EGS. Different EGS Collab stimulations will be performed under dissimilar stress conditions produce data for model comparisons that better differentiate stimulation mechanisms and the evolution of permeability enhancement in crystalline rock. EGS Collab experiments provide a means of testing tools, concepts and strategies that could later be employed under geothermal reservoir conditions at DOE’s Frontier Observatory for Research in Geothermal Energy (FORGE) and other enhanced geothermal systems. Key to the project is using numerical simulations in the experiment design and interpretation of results, and the collection of high-quality stimulation/flow, thermal, and geologic/geophysical data. A wide range of geologic and geophysical data have been acquired and interpreted for pre-stimulation testbed characterization. Multiple stimulation and flow tests have been performed at SURF, and multiple data sets have been collected and analyzed during these tests including electrical resistance tomography, microseismic, continuous active source seismic monitoring, distributed temperature, and the SIMFIP tool has been used to identify fracture formation and characteristics. An overview of some of the numerical simulations and experiments performed at SURF are presented.

15 GEOTHERMAL ENERGY↗

EGS Collab Project: Accomplishments and Plan

To better understand stimulation and inter-well flow in crystalline rock with the goal of developing and improving subsurface heat exchangers for enhanced geothermal energy recovery, the EGS (Enhanced Geothermal Systems) Collab project is developing highly monitored, well- characterized intermediate scale (~10-20 m) field test beds, stimulating, and performing flow tests. These tests provide the ability to evaluate concepts, data to test and validate models, and tools to be used for EGS development, which may be evaluated at DOE’s Frontier Observatory for Research in Geothermal Energy (FORGE) project. Numerical simulation is key to the project, for experiment design and interpretation of results. Testbed characterization included optical and acoustic televiewers, full waveform seismic, electromagnetic, gamma, and temperature. The test block was further characterized using seismic tomography (p- and s-), electrical resistance tomography (ERT), and hydrologic characterization including tracer tests. Coupled process models are constrained by the detailed site characterization data. Installed monitoring systems include: 1) passive seismic/acoustic emissions; 2) continuous active source seismic; 3) ERT, with dynamic imaging using high contrast fluids; and 4) distributed acoustic, temperature, and strain fiber optic sensors. During flow and stimulation tests, fracture aperture strain monitoring is performed using the Step-rate Injection Method for Fracture In-situ Properties (SIMFIP) tool. Pressure and flow in the injection and production boreholes are monitored, and tracer tests and wavefield imaging and inversion are performed to provide additional constraints. Stimulations have been performed at several locations, connecting our injection and production wells. An overview of the EGS Collab project is presented to provide a framework for other EGS Collab presentations, along with results from numerical simulations and experiments performed at the Sanford Underground Research Facility in South Dakota.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Effects of statistical uncertainty in activation calculations based on Monte Carlo radiation transport - 25353

This paper focuses on the analysis of the uncertainty in isotopic concentrations determined by Monte Carlo depletion calculations performed for the purposes of activation source calculations. In this work, we use repeated, statistically independent, Monte Carlo depletion calculations to examine the convergence behavior and statistical uncertainty in isotopic densities. Performing many, small, Monte Carlo depletion simulations and then recombining them is a useful approach and enables statistical analysis that can help ensure convergence. Convergence behavior is discussed in terms of stability of the mean, trends in the 95% confidence interval, and distributions of the isotopic densities. Just as in the more familiar Monte Carlo simulations of fluxes or reaction rates, convergence of isotopic densities may exhibit expected behavior such as stable means and 95% confidence intervals that decrease like N{sup -1/2} , or may exhibit poorly-converging behaviors. The most poorly-converging cases in this work were found to be for the products of high-energy threshold reactions. Finally, we examine the conditions under which uncertainty in the isotopic density can be determined from reaction rate uncertainty, and demonstrate the need for considering correlated variates in isotopic uncertainty propagation. Correlation between reaction rate tallies appears most important when the cross sections for the reactions and neutron energies considered are not strongly varying. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Construction, Test And Calibration of the GLAST Silicon Tracker

The Gamma-ray Large Area Space Telescope represents a great advance in space application of silicon detectors. With a surface of 80 m{sup 2} and about 1 M readout channels it is the largest silicon tracker ever built for a space experiment. GLAST is an astro-particle mission that will study the mostly unexplored, high energy (20 MeV-300 GeV) spectrum coming from active sources or diffused in the Universe. The detector integration and test phase is complete. The full instrument underwent environmental testing and the spacecraft integration phase has just started: the launch is foreseen in late 2007. In the meanwhile the spare modules are being used for instrument calibration and performance verification employing the CERN accelerator complex. A Calibration Unit has been exposed to photon, electron and hadron beams from a few GeV up to 300 GeV. We report on the status of the instrument and on the calibration campaign.

Instrumentation,OTHER↗

Comparison of active interrogation methods for source location in a scattering and absorbing medium, consisting of PGNAA, and an AmBe quasi-forward biased directional source

Source location of Special Nuclear Material (SNM) encompassing 95% 235 U and 239 Pu is identified by utilizing a directional source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron spectroscopy simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). BC-408, HPGe, LaBr 3 detector arrays were used to identify the location of the SNM using total counts incident on each detector, and PGNAA photopeaks from HPGe and LaBr 3 detector arrays in a polyethylene shield. The conducted simulations varied the volume and location of the SNM in the MCNP input files to observe how the source location method behaved. PGNAA photopeaks used for source identification include 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peaks from the prompt gamma interaction from hydrogen. The capabilities of each detector systems to acquire well resolved photopeaks with a 1% relative error or less, and total relative error for F4 and F8 tallies were less than 0.015% relative error. Source predictions of the SNM with uneven amounts of polyethylene shielding between the source and detectors was observed to overpredict and give invalid source location predictions. Source locations of the SNM with even amounts of polyethylene material between the source and each detector were found to be valid. With a 1 Ci 241 Am source activity, it was determined that 1630 s were needed to obtain the results for each detector system with the quasi-forward directional AmBe source. Coupling source and material identification together would increase acquisition time but would only require one system to determine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Analysis of an Actively Cooled Window for a High-Power Helicon Plasma Source

The material's plasma exposure experiment (MPEX) is a steady-state, linear plasma facility proposed to provide plasma conditions that simulate the first wall and divertor of the next-step fusion devices. MPEX will use an actively cooled, high-power helicon antenna as a plasma source. The antenna is located outside of the vacuum region, and during operation, a significant percentage of the antenna power is deposited on the plasma facing surface of the antenna window. The window thus must be actively cooled so that thermal stresses do not become excessive. The design presented includes two cylindrical windows with an annular water passage in-between in order to allow active cooling. A ceramic-to-metal seal is proposed in order to produce a water-to-vacuum seal that will not outgas and produce impurities. Experimental results from an uncooled window on a short-pulse prototype experiment are modeled using finite-element (FE) results in order to correlate with the heat flux profile. The design of the actively cooled window assembly is presented with computational fluid dynamics and FE analyses to confirm that the hardware can function with a 200-kW antenna within performance limits.

Lumsdaine, Arnold↗

THE 4 Ms CHANDRA DEEP FIELD-SOUTH NUMBER COUNTS APPORTIONED BY SOURCE CLASS: PERVASIVE ACTIVE GALACTIC NUCLEI AND THE ASCENT OF NORMAL GALAXIES

We present 0.5-2 keV, 2-8 keV, 4-8 keV, and 0.5-8 keV (hereafter soft, hard, ultra-hard, and full bands, respectively) cumulative and differential number-count (log N-log S) measurements for the recently completed Almost-Equal-To 4 Ms Chandra Deep Field-South (CDF-S) survey, the deepest X-ray survey to date. We implement a new Bayesian approach, which allows reliable calculation of number counts down to flux limits that are factors of Almost-Equal-To 1.9-4.3 times fainter than the previously deepest number-count investigations. In the soft band (SB), the most sensitive bandpass in our analysis, the Almost-Equal-To 4 Ms CDF-S reaches a maximum source density of Almost-Equal-To 27,800 deg{sup -2}. By virtue of the exquisite X-ray and multiwavelength data available in the CDF-S, we are able to measure the number counts from a variety of source populations (active galactic nuclei (AGNs), normal galaxies, and Galactic stars) and subpopulations (as a function of redshift, AGN absorption, luminosity, and galaxy morphology) and test models that describe their evolution. We find that AGNs still dominate the X-ray number counts down to the faintest flux levels for all bands and reach a limiting SB source density of Almost-Equal-To 14,900 deg{sup -2}, the highest reliable AGN source density measured at any wavelength. We find that the normal-galaxy counts rise rapidly near the flux limits and, at the limiting SB flux, reach source densities of Almost-Equal-To 12,700 deg{sup -2} and make up 46% {+-} 5% of the total number counts. The rapid rise of the galaxy counts toward faint fluxes, as well as significant normal-galaxy contributions to the overall number counts, indicates that normal galaxies will overtake AGNs just below the Almost-Equal-To 4 Ms SB flux limit and will provide a numerically significant new X-ray source population in future surveys that reach below the Almost-Equal-To 4 Ms sensitivity limit. We show that a future Almost-Equal-To 10 Ms CDF-S would allow for a significant increase in X-ray-detected sources, with many of the new sources being cosmologically distant (z {approx}> 0.6) normal galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Advancing local helicity injection for non-solenoidal tokamak startup

Experiments on the A ~ 1 PEGASUS ST are advancing the physics and technology basis of Local Helicity Injection (LHI). LHI injects helicity with relatively intense electron current sources in the plasma edge. It creates high toroidal current, toroidally-averaged tokamak-like plasmas that have been efficiently transitioned to Ohmically driven tokamak plasmas. Tradeoffs between physics and engineering goals are tested with LHI systems on the low-field-side and the high-field-side of PEGASUS, producing plasmas predominantly driven by non-solenoidal induction and DC helicity drive, respectively. An extensive LHI source development campaign comparing active arc sources, passive and gas-effused electrode sources lead to the selection of active arc sources for present and next-step LHI deployments. LHI plasmas with net toroidal current I p =0.225 MA, T e >100 eV, and n e ~ 10 19 m -3 are attained to date. A predictive 0D power-balance model describes experimental I p (t) and partitions the active current drive sources. High-frequency MHD activity is found to be present during LHI current drive, in addition to n=1 modes previously found in NIMROD simulation and experiment. A new system of reduced MHD activity was detected where n=1 activity is suppressed, LHI CD efficiency improves, and long-pulse plasmas are sustained with V IND ~ 0.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

5.0. Depletion, activation, and spent fuel source terms

SCALE’s general depletion, activation, and spent fuel source terms analysis capabilities are enabled through a family of modules related to the main ORIGEN depletion/irradiation/decay solver. The nuclide tracking in ORIGEN is based on the principle of explicitly modeling all available nuclides and transitions in the current fundamental nuclear data for decay and neutron-induced transmutation and relies on fundamental cross section and decay data in ENDF/B VII. Cross section data for materials and reaction processes not available in ENDF/B-VII are obtained from the JEFF-3.0/A special purpose European activation library containing 774 materials and 23 reaction channels with 12,617 neutron-induced reactions below 20 MeV. Resonance cross section corrections in the resolved and unresolved range are performed using a continuous-energy treatment by data modules in SCALE. All nuclear decay data, fission product yields, and gamma-ray emission data are developed from ENDF/B-VII.1 evaluations. Decay data include all ground and metastable state nuclides with half-lives greater than 1 millisecond. Using these data sources, ORIGEN currently tracks 174 actinides, 1149 fission products, and 974 activation products. The purpose of this chapter is to describe the stand-alone capabilities and underlying methodology of ORIGEN—as opposed to the integrated depletion capability it provides in all coupled neutron transport/depletion sequences in SCALE, as described in other chapters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-G-IeP4-14: Prostate Brachytherapy Activity Measurement and Source Localization by Using a Dual Photon Emission Computed Tomography System: A Feasibility Study

Purpose: To monitor the activity distribution and needle position during and after implantation in operating rooms. Methods: Simulation studies were conducted to assess the feasibility of measurement activity distribution and seed localization using the DuPECT system. The system consists of a LaBr3-based probe and planar detection heads, a collimation system, and a coincidence circuit. The two heads can be manipulated independently. Simplified Yb-169 brachytherapy seeds were used. A water-filled cylindrical phantom with a 40-mm diameter and 40-mm length was used to model a simplified prostate of the Asian man. Two simplified seeds were placed at a radial distance of 10 mm and tangential distance of 10 mm from the center of the phantom. The probe head was arranged perpendicular to the planar head. Results of various imaging durations were analyzed and the accuracy of the seed localization was assessed by calculating the centroid of the seed. Results: The reconstructed images indicate that the DuPECT can measure the activity distribution and locate the seeds dwelt in different positions intraoperatively. The calculated centroid on average turned out to be accurate within the pixel size of 0.5 mm. The two sources were identified when the duration is longer than 15 s. The sensitivity measured in water was merely 0.07 cps/MBq. Conclusion: Preliminary results show that the measurement of the activity distribution and seed localization are feasible using the DuPECT system intraoperatively. It indicates the DuPECT system has potential to be an approach for dose-distribution-validation. The efficacy of acvtivity distribution measurement and source localization using the DuPECT system will evaluated in more realistic phantom studies (e.g., various attenuation materials and greater number of seeds) in the future investigation.

60 APPLIED LIFE SCIENCES↗

The D-D Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Active Well Coincidence Counter

The 235 U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques due to the limited penetration of the item by the characteristic 235 U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Collar (UNCL) and 252 Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252 Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252 Cf shuffler systems rely on the use of high-output 252 Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every five to seven years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. In this work, we made use of Oak Ridge National Laboratory’s (ORNL’s) Large Volume Active Well Coincidence Counter (LV-AWCC) and a commercially available deuterium-deuterium (D-D) neutron generator to examine the potential of the D-D neutron generator as an alternative to the isotopic sources. We present the performance of the LV-AWCC with D-D generator for the assay of 235 U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium (DU), low enriched uranium (LEU), and highly enriched uranium (HEU) items.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Small Coronal Holes Near Active Regions as Sources of Slow Solar Wind

We discuss the nature of the small areas of rapidly diverging, open magnetic flux that form in the strong unipolar fields at the peripheries of active regions (ARs), according to coronal extrapolations of photospheric field measurements. Because such regions usually have dark counterparts in extreme-ultraviolet (EUV) images, we refer to them as coronal holes, even when they appear as narrow lanes or contain sunspots. Revisiting previously identified “AR sources” of slow solar wind from 1998 and 1999, we find that they are all associated with EUV coronal holes; the absence of well-defined He i 1083.0 nm counterparts to some of these holes is attributed to the large flux of photoionizing radiation from neighboring AR loops. Examining a number of AR-associated EUV holes during the 2014 activity maximum, we confirm that they are characterized by wind speeds of ∼300–450 km s{sup −1}, O{sup 7+}/O{sup 6+} ratios of ∼0.05–0.4, and footpoint field strengths typically of order 30 G. The close spacing between ARs at sunspot maximum limits the widths of unipolar regions and their embedded holes, while the continual emergence of new flux leads to rapid changes in the hole boundaries. Because of the highly nonradial nature of AR fields, the smaller EUV holes are often masked by the overlying canopy of loops, and may be more visible toward one solar limb than at central meridian. As sunspot activity declines, the AR remnants merge to form much larger, weaker, and longer-lived unipolar regions, which harbor the “classical” coronal holes that produce recurrent high-speed streams.

79 ASTRONOMY AND ASTROPHYSICS↗