Search NASA⌕ Search

SEARCH · Search NASA

Results for “adjust”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Defense Waste Processing Facility Nitric-Glycolic Flowsheet Chemical Process Cell Chemistry: Part 2

The conversions of nitrite to nitrate, the destruction of glycolate, and the conversion of glycolate to formate and oxalate were modeled for the Nitric-Glycolic flowsheet using data from Chemical Process Cell (CPC) simulant runs conducted by Savannah River National Laboratory (SRNL) from 2011 to 2016. The goal of this work was to develop empirical correlation models to predict these values from measurable variables from the chemical process so that these quantities could be predicted a-priori from the sludge or simulant composition and measurable processing variables. The need for these predictions arises from the need to predict the REDuction/OXidation (REDOX) state of the glass from the Defense Waste Processing Facility (DWPF) melter. This report summarizes the work on these correlations based on the aforementioned data. Previous work on these correlations was documented in a technical report covering data from 2011-2015. This current report supersedes this previous report. Further refinement of the models as additional data are collected is recommended. The glass REDOX depends on the concentrations of nitrate and manganese (oxidants), and of glycolate, formate, oxalate, carbon, and antifoam (reductants) in the melter feed. The waste sludge contains nitrite, nitrate, manganese (Mn), and oxalate. Virtually all of the nitrite is converted to nitrate or NO+NO 2 +N 2 O gases in the CPC. The portion of the nitrite converted to nitrate increases the amount of nitrate in the sludge. The amount of glycolate in the final melter feed depends on the amount of the glycolic acid feed that is destroyed. Similarly, the amounts of formate and oxalate formed during the decomposition of glycolic acid are required. The material balance on carbon was found to not close in most cases. Generally, there was less carbon at the end of testing compared to the inputs. The most uncertain product variable was glycolate, so material balances were performed where the glycolate concentration was adjusted, usually upward, to close the balance. Correlation versus the original, as-measured, data was generally poor, but correlation against the material balance adjusted values was greatly improved. It was also shown that the correlation of the measured REDOX versus the predicted REDOX was much better when the material balance adjusted glycolate values were used. Three data series were primarily used during the regressions of the data; these series were 1) Sludge Batch 9 NG flowsheet simulant runs NG51-62 (SB9-NG); 2) Scaled Runs + Bounding Hydrogen Runs (SR+BH); and 3) Runs GN43-50 and 57 (43-50,57). The glycolate destruction was found to correlate with acid stoichiometry (AS), percent reducing acid (PRA), and for some data series, headspace to simulant volume ratio (HSV), mercury (Hg), and nitrate. Although glycolate destruction for pairs of data series (e.g., [SB9-NG] and [SR+BH]) were found to depend on HSV, the combination of all three data series was not found to have significant dependence on this variable. The best model for glycolate destruction depended on AS, nitrate, and Hg. This model predicted the product glycolate compositions of the data to within 92-106%. The conversion of glycolate to formate was high when noble metals and Hg were not present, with values up to 100%. When noble metals and Hg were present, this conversion ranged from zero to 7%, and was dependent on AS. Lower AS gave higher conversions to formate. The conversion to oxalate was found to depend on the AS and the initial concentration of nitrite. An alternative fit versus AS and the form of ruthenium (Ru) used is a possible alternative. This fit was somewhat less statistically significant. This second model predicts that more oxalate is formed when Ru-nitrosyl nitrate is used rather than Ru chloride. The conversion of glycolate to oxalate ranged from zero to 6%. The conversion of nitrite to nitrate depended primarily on AS and PRA, with HSV and Hg being significant when these variables were varied. For multiple series of data, nitrite was also needed to SRNL-STI-2017-00172 5HYLVLRQ viL distinguish between data series, and the effect of HSV became insignificant. The best model for nitrite to nitrate conversion depended on AS, PRA, nitrite, and Hg. The 95% confidence intervals on the predicted values of glycolate destruction, glycolate to oxalate conversion, and nitrite to nitrate conversion were used to determine the uncertainty in the predicted REDOX when starting with only the composition of the sludge, AS, and PRA. Using the 95% confidences on an individual value (that is the confidence in getting a particular value for one single test as opposed to what the mean would be for multiple tests), the uncertainty in the predicted REDOX was calculated. The uncertainty in the actual product composition glycolate, oxalate, formate, and nitrate concentrations translated to an uncertainty in the REDOX value of ±0.1,which is approximately the uncertainty claimed in the REDOX model itself.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IDP Analysis of Tank 9H Mined Well Samples

The Savannah River Site (SRS) Tank Farm Transfer Control Program Description Document (PDD) requires Inhalation Dose Potential (IDP) testing to determine whether a transfer qualifies as a “HIGH-REM” (> 2.08E+08 rem/gal) or a “LOW-REM” (≤ 2.08E+08 rem/gal) waste transfer. Due to the unexpected presence of solids in a variable depth sample taken from Tank 9H, transfers from salt tanks potentially containing insoluble solids are currently being assessed as sludge slurry transfers. The insoluble solids concentration of such samples were requested to be adjusted to 16.7 wt% for the results to be used to bound future transfers from that tank. Two samples, HTF-09-21-100 and -101, were received from Tank 9H for analysis to determine IDP. The initial percent insoluble solids concentrations of HTF-09-21-100 and -101 were measured at 4.04 wt% and 6.23 wt%, respectively. Sample HTF-09-21-101 was adjusted to a target of at least 16.7 wt% insoluble solids by removing supernate. Analysis measured the adjusted insoluble solids concentration at 19.0 wt%. A representative sample was obtained for analysis. Then, based on calculations, supernate was added back to HTF-09-21-101 to achieve a percent insoluble solids concentration of 17.1 wt%, and a representative sample was collected for analysis. Based on duplicate analyses at 17.1 wt% and 19.0 wt% insoluble solids, the samples contain less than 0.0012 Ci/L of gross alpha activity. Therefore, the Tank 9H material can be transferred as a “LOW REM” transfer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GADRAS-DRF Enhancements for Safeguards – Custom Peak Fitting to Enhance Model Fitting and Isotopics

One major software update was accomplished within the Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) package. This update allows users to adjust individual peak fits for use in subsequent analysis processes within GADRAS-DRF. A graphical user interface (GUI) was implemented so users can see the effect of their fit adjustments on the spectrum. This new feature will enhance the capability of the previously funded auto-enrichment and peak-based 1D model fit feature that was implemented in FY23 (Fiscal Year). Isotopic analysis was performed using M400 data obtained from uranium standards and the isotopic assessment is given with and without manual peak adjustments.

07 ISOTOPE AND RADIATION SOURCES↗

Performance Testing of an Integrated Magnetic Power Take-Off

A wave energy converter (WEC) and the power take-off (PTO) generator system can be represented by using a mass-spring-dampener model. By incorporating a negative stiffness spring within the PTO, the overall stiffness of the PTO can be lowered allowing the impedance of the PTO to be more closely matched with the WEC. By designing for impedance matching the WEC can greatly enhance its power generation capability. This project has involved the design, fabrication and testing of a new type of linear-stroke length and rotary stroke length adjustable negative stiffness magnetic springs for use within a wave energy converter (WEC). The magnetic springs were studied by using 3-D finite element analysis with the objective of creating high energy density and a long linear stroke length. After the construction and testing of both a proof-of-principle adjustable linear and rotary magnetic spring prototype the rotary (torsional) magnetic spring was selected for scaling up analysis. The selected scaled-up proof-of-principle magnetic spring had a peak torque of 850 Nm with a ±45 degree stroke length. By translating the inner rotor relative to the outer rotor, the stiffness could be adjusted to be either negative or positive stiffness. During this project a magnetic lead screw was also studied, and it was shown that by combining the magnetic lead screw with a linearly translating magnetic spring a very long rotary stroke length could be attained. However, as the magnetic lead screw increased complexity and reduced overall energy density relative to a rotary (torsional) spring, this design approach was not further pursed. Dynamometer testing of the variable stiffness magnetic springs was first completed by Portland State University and following this the magnetic spring performance was independently verified by Sandia National Laboratory (Sandia). A WEC analysis when using a variable stiffness magnetic spring was completed by using the WecOptTool. WecOptTool is an open-source WEC optimization software developed by Sandia that supports efficient power take-off (PTO) and control optimization. Wave condition data from the Oregon PacWave test-site was used in this study. The analysis showed that a WEC with a tunable stiffness value could consistently achieve about 80% of its maximum theoretical power production. The use of a tunable stiffness WEC, rather than zero-stiffness or a constant stiffness WEC was also shown to lead to a smaller maximum PTO force requirement. The variable stiffness magnetic spring was integrated into an experimental WEC developed by Sandia, called a Wave-Bot. Sandia successfully completed water-tank testing of the Wave-Bot at the Navy’s Carderock, Maryland, wave-basin test site. The wave-basin testing helped to experimentally demonstrate the operating capabilities and increased power generation capability of a WEC containing an integrated variable stiffness magnetic spring. A WEC capacity factor analysis was also completed. The capacity factor was defined as the ratio of annual average WEC generator power to the maximum (RMS) generated power. This capacity factor provided a means of identifying the ratio of potential revenue to cost. It was calculated that if a tunable variable stiffness magnetic spring has RMS constraints it could operate with a capacity factor above 30%. This is comparable to a wind turbine’s capacity factor.

16 TIDAL AND WAVE POWER↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY 2024

Energy Savings Performance Contracts (ESPCs)are a contractual mechanism that allow a federal agency to procure energy savings and facility improvements without upfront capital costs to reduce costs and resiliency. ESPCs are covered under FAR Part 23.2, and 42 USC § 8287. Section 8287(a)(2)(A) of Title 42 of the U.S. Code requires that each energy savings performance contract (ESPC) undergo an annual energy audit, resulting in a separate audit report for every project. The objective of the present report is to compile and analyze all annual ESPC audit reports issued between October 1, 2023, and September 30, 2024, for projects awarded under Generations 1, 2, and 3 of DOE’s ESPC IDIQ contracts. During this period, 205 measurement and verification (M&V) reports were produced for 200 projects; the total number of reports exceeds the number of projects because some projects generated more than one report(for example, a few projects measure savings twice per year and produce two audit reports annually, each covering a different six-month period). By aggregating the results from these individual audits, the report determines the portfolio-wide realization rate of energy and cost savings for all active ESPC projects awarded under DOE’s IDIQ program. For all 205audit reports, sufficient information was available to compare project-level estimated, reported, and guaranteed cost savings. Reported cost savings accounted for ESCO verified savings per each project’s M&V plan. The total reported cost savings for the period addressed were $\$$647.8million,compared with the total guaranteed cost savings of $\$$601.6million. On average across the reported projects: •ESPC contractors guaranteed 92.8% of the estimated cost savings• projects reported achieving 100.0% of the estimated cost savings• projects reported achieving 107.7% of the guaranteed cost savings. The M&V performed for the period indicated adjustments for government operations and maintenance impacts to savings amount to$\$$43.9millionandcould be restored with the original operational parameters for impacted projects. Accounting for this potential cost savings impact, these projects still realized 100.4% of the guaranteed cost savings. The information on estimated and reported energy savings was collected and compared for all 205of the reports examined. Based on site energy, estimated savings totaled 14.88million MMBtu, and reported savings were 15.33million MMBtu; 3.1% greater than the estimated energy savings. All of the reports examined contained sufficient information to calculate source energy savings. Based on site-adjusted source energy, total estimated energy savings were 20.90 million MMBtu, and reported savings were 21.22million MMBtu, 101.5% of the estimated energy savings. For water savings, the estimated savings were 11,539,055 kGal and the reported savings were 13,315,930 kGal. This means 1,776,875 kGal more water was saved than estimated, which is about 15% higher than the estimate. These results indicate that, overall, the reported energy savings slightly exceeded the estimated values, while estimated water savings significantly exceeded estimated values, suggesting that the projects achieved greater cost savings than originally projected. The total annual expense for the ESCOs to perform annual M&V audits and reporting was $\$$10.02million. Through this effort, $\$$647.8 million in annual cost savings was verified. The M&V results indicated that $\$$43.9 million of these verified savings reflected adjustments due to government operations A-6and maintenance impacts, which could be restored under the original operational parameters for the affected projects. These findings show the value of M&V that only costs 1.7%of the guaranteed cost savings to ensure guarantees are met.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Response Of Salt Intrusion In A Tidal Estuary To Regional Climatic Forcing (FVCOM Output for the baseline scenario)

Salinity distribution in a large tidal estuary is subject to estuarine adjustment under the influences of multiple physical drivers such as freshwater pulses and sea level rise, and is crucial to upstream water quality, aquaculture, and ecosystem functions of the estuary. To better understand the estuarine salinity response to climate change, the unstructured-grid Finite Volume Community Ocean Model was implemented to simulate the salt intrusion in the Delaware Bay Estuary. The model was first validated by multiple observational data sets and subsequently applied in an idealized setting to examine the response of salt front to freshwater pulses in high flow conditions, followed by a long-term drought condition supported by a multi-decadal streamflow drought analysis in the estuary. The model results showed that after the freshwater pulses the salt front location moved further upstream with sea level rise. Under the simulated long-term drought condition, the adjustment timescale of salt intrusion varies nonlinearly with sea level rise. With a significant increase in sea level rise, the adjustment timescale starts to decrease. This shift suggests a transition into a different regime where the estuary becomes more stratified, as indicated by an increasing bulk Simpson number with rising sea levels. These findings have been summarized into a journal manuscript. The data included in this information release request are FVCOM model output associated with the numerical simulations described in the journal manuscript.

Liu, Jinliang↗

Limits on the Range and Rate of Change in Power Take-Off Load in Ocean Wave Energy Conversion: A Study Using Model Predictive Control

Previous work comparing power take-off (PTO) architectures for ocean wave-powered reverse osmosis suggests that variable displacement in the wave energy converter (WEC)-driven pump does not offer a significant performance advantage. A limitation of that study is that the WEC was subject to a constant load within a given sea state (“Coulomb damping”) and did not account for controlled, moment-to-moment variation of the PTO load enabled by a variable displacement pump. This study explores the potential performance advantage of a variable PTO load over Coulomb damping. Model predictive control is used to provide optimal load control with constraints on the PTO load. The constraints include minimum and maximum loads and a limit on the rate of load adjustment. Parameter studies on these constraints enable conclusions about PTO design requirements in addition to providing an estimated performance advantage over Coulomb damping. Numerical simulation of the Oyster 1 WEC is carried out with performance weighted by historical sea state data from Humboldt Bay, CA. The results show a performance advantage of up to 20% higher yearly-average power absorption over Coulomb damping. Additionally, the parameter studies suggest that the PTO load should be adjustable down to at least 25% of the maximum load and should be adjustable between the minimum and maximum loads within a few seconds.

16 TIDAL AND WAVE POWER↗

Maximizing Wave Energy Converter Power Extraction by Utilizing a Variable Negative Stiffness Magnetic Spring

Complex conjugate impedance matching is a key concept for wave energy converter design. Matching the impedance of the power take-off (PTO) system to the complex conjugate of the wave energy converter's (WEC) impedance ensures efficient transfer of energy from the WEC body motion to electrical power. In low frequency waves, impedance matching often requires a negative PTO stiffness. In this paper, an adjustable stiffness magnetic torsion spring will be presented and modeled to understand its potential to improve WEC performance. The spring has the ability to provide a negative stiffness, allowing the PTO impedance to more closely match the complex conjugate of the WEC impedance at low frequencies. The spring also supports an adjustable stiffness value, meaning it can be tuned according to the incoming wave conditions. The spring's tunability may put less stress on the rest of the PTO system in wave conditions outside its normal operation zone without sacrificing electrical power output. The adjustable magnetic spring's effects are modeled and explored in this paper by examining the resultant average annual electrical power and capacity factor. The study suggests that the tunable magnetic spring has the potential to significantly improve capacity factor while maintaining a high average electrical power.

16 TIDAL AND WAVE POWER↗

The Active Optics System on the Vera C. Rubin Observatory: Optimal Control of Degeneracy among the Large Number of Degrees of Freedom

Abstract The Vera C. Rubin Observatory is a unique facility for survey astronomy that will soon be commissioned and begin operations. Crucial to many of its scientific goals is the achievement of sustained high image quality, limited only by the seeing at the site. This will be maintained through an active optics system that controls optical element misalignments and corrects mirror figure error to minimize aberrations caused by both thermal and gravitational effects. However, the large number of adjustment degrees of freedom available on the Rubin Observatory introduces a range of degeneracies, including many that are induced by noise due to imperfect measurement of the wave-front errors. We present a structured methodology for identifying these degeneracies through an analysis of image noise level. We also present a novel scaling strategy based on truncated singular value decomposition that mitigates the degeneracy and optimally distributes the adjustment over the available degrees of freedom. Our approach ensures the attainment of optimal image quality, while avoiding excursions around the noise-induced subspace of degeneracies, marking a significant improvement over the previous techniques adopted for Rubin, which were based on an optimal integral controller. This new approach is likely to also yield significant benefits for all telescopes that incorporate large numbers of degrees of freedom of adjustment.

79 ASTRONOMY AND ASTROPHYSICS↗

Global nitrogen and sulfur deposition mapping using a measurement–model fusion approach

Abstract. Global reactive nitrogen (N) deposition has more than tripled since 1860 and is expected to remain high due to food production and fossil fuel consumption. Global sulfur emissions have been decreasing worldwide over the last 30 years, but many regions are still experiencing unhealthily high levels of deposition. We update the 2010 global deposition budget for reactive nitrogen and sulfur components with new regional wet deposition measurements from Asia, improving the ensemble results of 11 global chemistry transport models from the second phase of the United Nations Economic Commission for Europe's Task Force on Hemispheric Transport of Air Pollution (HTAP II). The observationally adjusted global N deposition budget is 114.5 Tg N, representing a minor increase of 1 % from the model-only derived values, and the adjusted global sulfur deposition budget is 88.9 Tg S, representing a 6.5 % increase from the modeled values, using an interpolation distance of 2.5∘. Regionally, deposition adjustments can be up to ∼ 73 % for nitrogen and 112 % for sulfur. Our study demonstrates that a global measurement–model fusion approach can improve N and S deposition model estimates at a regional scale, with sufficient availability of observations; however, in large parts of the world, alternative approaches need to be explored. The analysis presented here represents a step forward toward the World Meteorological Organization's goal of global fusion products for accurately mapping harmful air pollution deposition.

Rubin, Hannah J. (ORCID:0000000182226924)↗

CICE on a C-grid: new momentum, stress, and transport schemes for CICEv6.5

Abstract. This article presents the C-grid implementation of the CICE sea ice model, including the C-grid discretization of the momentum equation, the boundary conditions (BCs), and the modifications to the code required to use the incremental remapping transport scheme. To validate the new C-grid implementation, many numerical experiments were conducted and compared to the B-grid solutions. In idealized experiments, the standard advection method (incremental remapping with C-grid velocities interpolated to the cell corners) leads to a checkerboard pattern. A modal analysis demonstrates that this computational noise originates from the spatial averaging of C-grid velocities at corners. The checkerboard pattern can be eliminated by adjusting the departure regions to match the divergence obtained from the solution of the momentum equation. We refer to this novel approach as the edge flux adjustment (EFA) method. The C-grid discretization with edge flux adjustment allows for transport in channels that are one grid cell wide – a capability that is not possible with the B-grid discretization nor with the C-grid and standard remapping advection. Simulation results match the predicted values of a novel analytical solution for one-grid-cell-wide channels.

Lemieux, Jean-François (ORCID:0000000320845759)↗

Integrating New Arctic Plant Functional Types in a Land Surface Model Using Above- and Belowground Field Observations: Modeling Archive

This Modeling Archive is in support of an NGEE Arctic publication "Integrating New Arctic Plant Functional Types in a Land Surface Model Using Above- and Belowground Field Observations". We used field observations of biomass and leaf traits (Salmon et al., 2019b) across a gradient of plant communities on the Seward Peninsula in northwest Alaska (Breen et al., 2020; Iversen et al., 2017) to replace the original ELM configuration with nine, arctic-specific PFTs. Original arctic PFTs in the model were (1) broadleaf deciduous boreal shrub and (2) C3 arctic grass. New PFTs were (1) lichen, (2) bryophyte, (3) evergreen dwarf shrub, (4) deciduous dwarf shrub, (5) deciduous low shrub, (6) deciduous low to tall shrub, (7) alder shrub, (8) forb, and (9) graminoid. New PFTs were parameterized and evaluated using site-level trait and biomass measurements (Salmon et al., 2019b), root C:N ratios and rooting depth patterns (Salmon et al., 2019c), and root biomass (Salmon et al., 2020). This archive contains forcing data and model output from ELM simulations conducted at the Kougarok Hillslope site (Kougarok Road Mile Marker 64). Simulations were conducted for the Kougarok Hillslope site using meteorological driving data from the Scenarios Network for Alaska and Arctic Planning (SNAP) downscaled climate projection dataset using NCAR-CCSM forcing (Bieniek et al., 2020 dataset; Walsh et al., 2018). The archive includes three versions of model simulations representing a progression from the original model configuration to an Arctic-specific configuration (see Output section below). Simulation 1 used grid cell data from a global E3SM configuration, including the fractional area of E3SM PFTs assigned to the grid cell containing the Kougarok Hillslope site in global simulations. This simulation did not distinguish between different plant communities on the Kougarok Hillslope, but instead used a single point simulation to represent the entire area. Simulation 2 used default E3SM PFT definitions combined with adjusted depth to bedrock for plant communities with shallow rocky layers to represent the role of abiotic soil factors in driving site differences (based on depth measurements of Iversen et al., 2019a), and adjusted the relative areas of the broadleaf deciduous boreal shrub and C3 arctic grass PFTs to reflect the observed spatial coverage of shrub and non-shrub PFTs across Kougarok Hillslope plant communities. Simulation 3 used the new arctic PFT definitions and parameterizations based on the vegetation types present at the site, along with the adjusted soil depths used in Simulation 2. Included are *.pdf, *.nc (NetCDF), *tar.gz, *.py, and *.bash files. We would like to thank Mary's Igloo Native Corporation for allowing us to perform this research on their land and giving us the opportunity to share this research with their community. Thanks to Shawn Serbin and Alistair Rogers for helpful discussions. Holly Vander Stel, Joanne Childs, and Stan Wullschleger helped with collection of field data. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

42 ENGINEERING↗

Memory page access counts based on page refresh

A processing system tracks counts of accesses to memory pages using a set of counters located at the memory module that stores the pages, wherein the counts are adjusted at least in part based on refreshes of the memory pages. This approach allows a processing system to efficiently maintain the counts with relatively small counters and with relatively low overhead. Furthermore, the rate at which the counters are adjusted, relative to the page refreshes, is adjustable, so that the access counts are useful for a wide variety of application types.

97 MATHEMATICS AND COMPUTING↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

Campbell, Levi A.↗