Search NASA⌕ Search

SEARCH · Search NASA

Results for “alarms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Clear air turbulence - An airborne alert system

An infrared radiometer system has been developed that can alert a pilot of an aircraft 2 to 9 minutes in advance of an encounter with clear air turbulence. The time between the warning and the clear air turbulence event varies with the flight altitude of the aircraft. In turbulence-free areas, the incidence of false alarms is found to be less than one in 3.4 hours of flight time compared to less than one per 10 hours of flight time in areas with turbulence.

Stearns, L. P.↗

On the reliability of hook echoes as tornado indicators

A study of radar echoes associated with the tornadoes of the 3 April 1974 outbreak was performed to evaluate the usefulness of echo shape as an indicator of tornadic thunderstorms. The hook shape was usually successful in characterizing an echo as tornadic, with a false alarm rate of 16%. Because hook echoes were relatively rare, however, a less restrictive shape called distinctive was more successful at detecting tornadic thunderstorms, identifying 65% of the tornadic echoes. An echo had a distinctive shape if it possessed a marked appendage on its right rear flank or was in the shape of a spiral, comma or line echo wave pattern (LEWP). Characteristics of the distinctive echo are given.

Forbes, G. S.↗

Traveling-wave maser, closed cycle refrigerator automation

At the present time all traveling-wave maser and closed-cycle refrigerator system (TWM-CCR) and their power supply and helium compressor assemblies are operated manually. Many man-hours are required of highly trained and experienced operators, resulting in high operator cost. Of greater importance are the problems of unpredictable failure and long downtimes. Since field performance is not monitored, system degradation is detected only when it has progressed to the point of catastrophic failure. Without the aid of performance histories, failure diagnosis is arduous and slow. Rational and functional requirements for the TWM-CCR Automation project are the following: (1) to improve reliability and reduce downtime by providing unattended monitor and control, alarm and fault location, failure prediction and self-corrective action; (2) to reduce operator cost by providing automatic tuning and cooldown procedures; and (3) to improve system operations and development by providing the needed engineering data.

Mcneil, J. A.↗

Biomedical technology transfer. Applications of NASA science and technology

Ongoing projects described address: (1) intracranial pressure monitoring; (2) versatile portable speech prosthesis; (3) cardiovascular magnetic measurements; (4) improved EMG biotelemetry for pediatrics; (5) ultrasonic kidney stone disintegration; (6) pediatric roentgen densitometry; (7) X-ray spatial frequency multiplexing; (8) mechanical impedance determination of bone strength; (9) visual-to-tactile mobility aid for the blind; (10) Purkinje image eyetracker and stabilized photocoalqulator; (11) neurological applications of NASA-SRI eyetracker; (12) ICU synthesized speech alarm; (13) NANOPHOR: microelectrophoresis instrument; (14) WRISTCOM: tactile communication system for the deaf-blind; (15) medical applications of NASA liquid-circulating garments; and (16) hip prosthesis with biotelemetry. Potential transfer projects include a person-portable versatile speech prosthesis, a critical care transport sytem, a clinical information system for cardiology, a programmable biofeedback orthosis for scoliosis a pediatric long-bone reconstruction, and spinal immobilization apparatus.

Harrison, D. C.↗

Portable medical status and treatment system

A portable medical status and treatment system is discussed. The vital signs monitor includes electrocardiogram, respiration, temperature, blood pressure, alarm, and power subsystems, which are described. A DC defibrillator module, a radio module, and their packaging are also described. These subsystems were evaluated and the results and recommendations are presented.

Source record↗

An adaptive tracking observer for failure-detection systems

The design problem of adaptive observers applied to linear, constant and variable parameters, multi-input, multi-output systems, is considered. It is shown that, in order to keep the observer's (or Kalman filter) false-alarm rate (FAR) under a certain specified value, it is necessary to have an acceptable proper matching between the observer (or KF) model and the system parameters. An adaptive observer algorithm is introduced in order to maintain desired system-observer model matching, despite initial mismatching and/or system parameter variations. Only a properly designed adaptive observer is able to detect abrupt changes in the system (actuator, sensor failures, etc.) with adequate reliability and FAR. Conditions for convergence for the adaptive process were obtained, leading to a simple adaptive law (algorithm) with the possibility of an a priori choice of fixed adaptive gains. Simulation results show good tracking performance with small observer output errors and accurate and fast parameter identification, in both deterministic and stochastic cases.

Sidar, M.↗

Test apparatus for locating shorts during assembly of electrical buses

A test apparatus is described for locating electrical shorts that is especially suited for use while an electrical circuit is being fabricated or assembled. A ring counter derives input pulses from a square wave oscillator. The outputs of the counter are fed through transistors to an array of light emitting diodes. Each diode is connected to an electrical conductor, such as a bus bar, that is to be tested. In the absence of a short between the electrical conductors the diodes are sequentially illuminated. When a short occurs, a comparator/multivibrator circuit triggers an alarm and stops the oscillator and the sequential energization of the diodes. The two diodes that remain illuminated identify the electrical conductors that are shorted.

Deboo, G. J.↗

Thermal monitoring, measurement, and control system for a Volatile Condensable Materials (VCM) test apparatus

A thermal monitoring and control concept is described for a volatile condensable materials (VCM) test apparatus where electric resistance heaters are employed. The technique is computer based, but requires only proportioning ON/OFF relay control signals supplied through a programmable scanner and simple quadrac power controllers. System uniqueness is derived from automatic temperature measurements and the averaging of these measurements in discrete overlapping temperature zones. Overall control tolerance proves to be better than + or - 0.5 C from room ambient temperature to 150 C. Using precisely calibrated thermocouples, the method provides excellent temperature control of a small copper VCM heating plate at 125 + or - 0.2 C over a 24 hr test period. For purposes of unattended operation, the programmable computer/controller provides a continual data printout of system operation. Real time operator command is also provided for, as is automatic shutdown of the system and operator alarm in the event of malfunction.

Ives, R. E.↗

Pulsed multiwavelength laser ranging system

A pulsed multiwavelength laser ranging system for measuring atmospheric delay was built and tested, and its theoretical performance limits were calculated. The system uses a dye modelocked ND:YAG laser, which transmits 70 psec wide pulses simultaneously at 1064, 532, and 355 nm. The differential delay of the 1064 and 355 nm pulses is measured by a specially calibrated waveform digitizer to estimate the dry atmospheric delay. The delay time of the 532 nm pulse is used to measure the target distance. Static crossed field photomultipliers are used as detectors for all wavelengths. Theoretical analysis shows that path curvature and atmospheric turbulence are fundamental limits to the ranging accuracy of both single and multicolor systems operating over horizontal paths. For two color systems, an additional error is caused by the uncertainty in the path averaged water vapor. The standard deviation of the multicolor instrument's timing measurements is directly proportional to the laser pulse width plus photomultiplier jitter divided by the square root of the received photoelectron number. The prototype system's maximum range is km, which is limited by atmospheric and system transmission losses at 355 nm. System signal detection and false alarm calculations are also presented.

Abshire, J. B.↗

Design of analytical failure detection using secondary observers

The problem of designing analytical failure-detection systems (FDS) for sensors and actuators, using observers, is addressed. The use of observers in FDS is related to the examination of the n-dimensional observer error vector which carries the necessary information on possible failures. The problem is that in practical systems, in which only some of the components of the state vector are measured, one has access only to the m-dimensional observer-output error vector, with m or = to n. In order to cope with these cases, a secondary observer is synthesized to reconstruct the entire observer-error vector from the observer output error vector. This approach leads toward the design of highly sensitive and reliable FDS, with the possibility of obtaining a unique fingerprint for every possible failure. In order to keep the observer's (or Kalman filter) false-alarm rate under a certain specified value, it is necessary to have an acceptable matching between the observer (or Kalman filter) models and the system parameters. A previously developed adaptive observer algorithm is used to maintain the desired system-observer model matching, despite initial mismatching or system parameter variations. Conditions for convergence for the adaptive process are obtained, leading to a simple adaptive law (algorithm) with the possibility of an a priori choice of fixed adaptive gains. Simulation results show good tracking performance with small observer output errors, while accurate and fast parameter identification, in both deterministic and stochastic cases, is obtained.

Sisar, M.↗

Model degradation effects on sensor failure detection

This paper discusses the effects of imperfect modeling on the detection and isolation of sensor failures. For systems with non-zero set points, deterministic inputs or non-zero noise biases, the model mismatch appears as a bias on the stochastic innovation process. This bias, if left unaccounted for, would be sufficient to declare a false alarm failure in one or more sensors. A practical design procedure based upon the Generalized Likelihood Ratio (GLR) form uses a finite data window sequential t-test to detect and isolate model mismatch effects and soft sensor failures. Application to an eighth order model of the QCSEE turbofan engine is discussed.

Leininger, G. G.↗

Aspects of clear air turbulence severity forecasting and detection

Factors influencing the accuracy of the forecasts of incidences of clear air turbulence (CAT) are discussed, along with techniques for improved verification. Descriptive ranking terms for the intensity of CAT events, ranging from light to extreme, are developed, and meteorological parameters used for predictions are reviewed, including jetstream core location, vertical and horizontal wind shears, stable layers, tropopause height, trough speed, 500-mb vorticity, surface fronts, pressure centers and cyclogenesis, and wind speeds near mountain ridges. Methods of remote detection of CAT, particularly by using radiometry sensitive to the IR water vapor band, are noted to have had some success in detecting actual CAT events and decreasing false alarms. Statistical aspects of CAT encounter severity are discussed, including the establishment of confidence intervals for thresholds of detection of CATs of varying intensities.

Ehernberger, L. J.↗

Detecting Solar-Cell Failures

Circuit identified malfunctioning photovoltaic array. Cell-failure detection circuit compares output of photovoltaic array to control cell. If any module fails, activates light-emitting diode. Circuit could also sound alarm.

Maloney, T. J.↗

Rain and Dew Detector

Multifinger transducer actuates simple circuit that sets off alarm when moisture bridges fingers.

Laue, E. G.↗

Reliability analysis and fault-tolerant system development for a redundant strapdown inertial measurement unit

A methodology is developed and applied for quantitatively analyzing the reliability of a dual, fail-operational redundant strapdown inertial measurement unit (RSDIMU). A Markov evaluation model is defined in terms of the operational states of the RSDIMU to predict system reliability. A 27 state model is defined based upon a candidate redundancy management system which can detect and isolate a spectrum of failure magnitudes. The results of parametric studies are presented which show the effect on reliability of the gyro failure rate, both the gyro and accelerometer failure rates together, false alarms, probability of failure detection, probability of failure isolation, and probability of damage effects and mission time. A technique is developed and evaluated for generating dynamic thresholds for detecting and isolating failures of the dual, separated IMU. Special emphasis is given to the detection of multiple, nonconcurrent failures. Digital simulation time histories are presented which show the thresholds obtained and their effectiveness in detecting and isolating sensor failures.

Motyka, P.↗

Potential Applications of LANDSAT Data in Energy Management Associated with Kenya's Forests

LANDSAT can be effectively used to monitor the extent and magnitude of forest cover change in Kenya in order to evaluate the potential for energy supply. Digital processing of LANDSAT data provides a reliable monitoring technique for forest resource management in Kenya. Data analysis was used to illustrate that Kenya's forests are indeed diminishing. A model used to make projections for the availability of fuelwood as an energy source is presented. The resulting figures imply that Kenya's forest will all but disappear around the end of the 20th century. Analysis of LANDSAT data for Mau East substantiates these alarming findings.

Maghenda, M. M.↗

Node Synchronization for the Viterbi Decoder

At very low signal to noise ratios such as those that Voyager 2 will encounter at Uranus, the performance of the Reed-Solomon/Viterbi concatenated coding system could be seriously degraded by loss of node synchronization by the Viterbi decoder. This problem is described and now it can be almost completely avoided with a simple outboard hardware ""node synchronizer''. This device makes statistical decisions about node sync based on the hard quantized undecoded data stream. In a worst case Voyager-like environment, our method will detect and correct a true loss of node sync (thought to be a very rate event) within several hundred bits; many of these false alarms for our technique is on the order several years.

Lorden, G.↗

Scanning seismic intrusion detection method and apparatus

An intrusion monitoring system includes an array of seismic sensors, such as geophones, arranged along a perimeter to be monitored for unauthorized intrusion as by surface movement or tunneling. Two wires lead from each sensor to a central monitoring station. The central monitoring station has three modes of operation. In a first mode of operation, the output of all of the seismic sensors is summed into a receiver for amplification and detection. When the amplitude of the summed signals exceeds a certain predetermined threshold value an alarm is sounded. In a second mode of operation, the individual output signals from the sensors are multiplexed into the receiver for sequentially interrogating each of the sensors.

Lee, R. D.↗