Search NASA⌕ Search

SEARCH · Search NASA

Results for “application specific integrated circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Development and Performance of a Suprathermal Electron Spectrometer to Study Auroral Precipitations

The design, development, and performance of Medium-energy Electron SPectrometer (MESP), dedicated to the in situ observation of suprathermal electrons in the auroral ionosphere, are summarized in this paper. MESP employs a permanent magnet filter with a light tight structure to select electrons with proper energies guided to the detectors. A combination of two avalanche photodiodes and a large area solid-state detector (SSD) provided 46 total energy bins (1 keV resolution for 3-20 keV range for APDs, and 7 keV resolution for greater than 20 keV range for SSDs). Multi-channel ultra-low power application-specific integrated circuits are also verified for the flight operation to read-out and analyze the detector signals. MESP was launched from Poker F1at Research Range on 3 March 2014 as a part of ground-to-rocket electrodynamics-electrons correlative experiment (GREECE) mission. MESP successfully measured the precipitating electrons from 3 to 120 keV in 120-ms time resolution and characterized the features of suprathermal distributions associated with auroral arcs throughout the flight. The measured electrons were showing the inverted-V type spectra, consistent with the past measurements. In addition, investigations of the suprathermal electron population indicated the existence of the energetic non-thermal distribution corresponding to the brightest aurora.

Ogasawara, Keiichi↗

A Low-Power Correlator ASIC for Arrays with Many Antennas

We report the design of a new application-specific integrated circuit (ASIC) for use in radio telescope correlators. It supports the construction of correlators for an arbitrarily large number of signals. The ASIC uses an intrinsically low-power architecture along with design techniques and a process that together result in unprecedentedly low power consumption. The design is flexible in that it can support telescopes with almost any number of antennas N. It is intended for use in an "FX" correlator, where a uniform filter bank breaks each signal into separate frequency channels prior to correlation.

radio telescopes↗

A Compact, Multi-view Net Flux Radiometer for Future Uranus and Neptune Probes

A Net Flux Radiometer (NFR) is presented that can be included in an atmospheric structure instrument suite for future probe missions to the icy giants Uranus and Neptune. The baseline design has two spectral channels i.e., a solar channel (0.4-to-3.5 m) and a thermal channel (4-to-300 m). The NFR is capable of viewing five distinct viewing angles during the descent. Non-imaging Winston cones with band-pass filters are used for each spectral channel and to define a 5 angular acceptance. Uncooled thermopile detectors are used in each spectral channel and are read out using a custom radiation hard application specific integrated circuit (ASIC). The baseline design can easily be changed to increase the number of detector channels from two to seven.

Aslam, S.↗

Guideline for Single-Event Effect (SEE) Testing of System on a Chip (SOC) Devices

The use of complex single and multicore processors with significant cache memory, on-chip peripherals, memory controllers, and high speed input/output (IO) that integrate many of the parts of a traditional computer system is becoming more common in space applications. Such devices are often referred to as system on a chip devices (SOCs), even though the term is used somewhat inaccurately due to the lack of analog and mixed signal subcircuits. These devices are complex combinations of single- or multi-core processors with memory controllers, high-speed input/output (IO), and other peripheral structures that formerly would have been handled by off-chip resources. In the past the processors were tested for single event effects (SEE) separately, and the peripherals were often put into custom application-specific integrated circuits (ASICs) along with other resources required by the user. Performance and cost pressures have pushed commercial devices to incorporate many of the functional blocks into a single chip, an SOC. The NASA Electronic Parts and Packaging Program (NEPP) has been examining ways to perform SEE radiation hardness assurance (RHA) testing of these processor-centric SOCs to achieve reasonable understanding of their performance in space missions.

Guertin, Steven M.↗

Single-Event Effect Testing of the PNI RM3100 Magnetometer for Space Applications

The results of a destructive single-event effect susceptibility radiation test of the PNI RM3100 magnetometer sensor, specifically the MagI 2 C ASIC (application-specific integrated circuit) on the sensor board are presented. The sensor is a low-resource commercial off-the-shelf (COTS) magneto-inductive magnetometer. The device was monitored for destructive events and functional interruptions during exposure to a heavy ion beam at the Lawrence Berkeley National Laboratory's 88′′ Cyclotron. The RM3100 did not experience any destructive single-event effects when irradiated to a total fluence of 1.4 × 10 7 cm −2 at an effective linear energy transfer (LET) of 76.7 MeV cm 2 mg −1 while operated at nominal voltage (3.3 V) and elevated temperature (85 ∘C). When these results are combined with previous total ionizing dose tests showing no failures up to 150 kRad (Si), we conclude that the PNI RM3100 is extremely radiation tolerant and can be used in a variety of space environments.

Mark B. Moldwin↗

TARGET: A multi-channel digitizer chip for very-high-energy gamma-ray telescopes

The next-generation very-high-energy (VHE) gamma-ray observatory, the Cherenkov Telescope Array, will feature dozens of imaging atmospheric Cherenkov telescopes (IACTs), each with thousands of pixels of photosensors. To be affordable and reliable, reading out such a mega-channel array requires event recording technology that is highly integrated and modular, with a low cost per channel. We present the design and performance of a chip targeted to this application: the TeV Array Readout with GSa/s sampling and Event Trigger (TARGET). This application-specific integrated circuit (ASIC) has 16 parallel input channels, a 4096-sample buffer for each channel, adjustable input termination, self-trigger functionality, and tight window-selected readout. We report the performance of TARGET in terms of sampling frequency, power consumption, dynamic range, current-mode gain, analog bandwidth, and cross talk. The large number of channels per chip allows a low cost per channel ($10 to $20 including front-end and back-end electronics but not including photosensors) to be achieved with a TARGET-based IACT readout system. In addition to basic performance parameters of the TARGET chip itself, we present a camera module prototype as well as a second-generation chip (TARGET 2), both of which have been produced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

ASIC for SDD-Based X-Ray Spectrometers

We present an application-specific integrated circuit (ASIC) for high-resolution x-ray spectrometers (XRS). The ASIC reads out signals from pixelated silicon drift detectors (SDDs). The pixel does not have an integrated field effect transistor (FET); rather, readout is accomplished by wire-bonding the anodes to the inputs of the ASIC. The ASIC dissipates 32 mW, and offers 16 channels of low-noise charge amplification, high-order shaping with baseline stabilization, discrimination, a novel pile-up rejector, and peak detection with an analog memory. The readout is sparse and based on custom low-power tristatable low-voltage differential signaling (LPT-LVDS). A unit of 64 SDD pixels, read out by four ASICs, covers an area of 12.8 cm{sup 2} and dissipates with the sensor biased about 15 mW/cm{sup 2}. As a tile-based system, the 64-pixel units cover a large detection area. Our preliminary measurements at -44 C show a FWHM of 145 eV at the 5.9 keV peak of a {sup 55}Fe source, and less than 80 eV on a test-pulse line at 200 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Fast Neutron Imaging Measurements with the Fieldable Nuclear Materials Identification System

This paper describes some recent fast neutron imaging measurements of the fieldable nuclear materials identification system (FNMIS) under development by the National Nuclear Security Administration (NNSA-NA-22) for possible future use in arms control and nonproliferation applications. The general configuration of FNMIS has been previously described, and a description of the application-specific integrated circuit (ASIC) electronics designed for FNMIS has been reported. This paper presents initial imaging measurements performed at ORNL with a Thermo Fisher API 120 DT generator and the fast-neutron imaging module of FNMIS.

Wellington, Tracey↗

Design Methodology: ASICs with complex in-pixel processing for Pixel Detectors

The development of Application Specific Integrated Circuits (ASIC) for pixel detectors with complex in-pixel processing using Computer Aided Design (CAD) tools that are, themselves, mainly developed for the design of conventional digital circuits requires a specialized approach. Mixed signal pixels often require parasitically aware detailed analog front-ends and extremely compact digital back-ends with more than 1000 transistors in small areas below 100μm x 100μm. These pixels are tiled to create large arrays, which have the same clock distribution and data readout speed constraints as in, for example, micro-processors. The methodology uses a modified mixed-mode on-top digital implementation flow to not only harness the tool efficiency for timing and floor-planning but also to maintain designer control over compact parasitically aware layout.

43 PARTICLE ACCELERATORS↗

Wafer-scale pixelated detector system

A large area, gapless, detection system comprises at least one sensor; an interposer operably connected to the at least one sensor; and at least one application specific integrated circuit operably connected to the sensor via the interposer wherein the detection system provides high dynamic range while maintaining small pixel area and low power dissipation. Thereby the invention provides methods and systems for a wafer-scale gapless and seamless detector systems with small pixels, which have both high dynamic range and low power dissipation.

42 ENGINEERING↗

Multi-petascale highly efficient parallel supercomputer

A Multi-Petascale Highly Efficient Parallel Supercomputer of 100 petaflop-scale includes node architectures based upon System-On-a-Chip technology, where each processing node comprises a single Application Specific Integrated Circuit (ASIC). The ASIC nodes are interconnected by a five dimensional torus network that optimally maximize the throughput of packet communications between nodes and minimize latency. The network implements collective network and a global asynchronous network that provides global barrier and notification functions. Integrated in the node design include a list-based prefetcher. The memory system implements transaction memory, thread level speculation, and multiversioning cache that improves soft error rate at the same time and supports DMA functionality allowing for parallel processing message-passing.

97 MATHEMATICS AND COMPUTING↗

Wafer-scale pixelated detector system

A large area, gapless, detection system comprises at least one sensor; an interposer operably connected to the at least one sensor; and at least one application specific integrated circuit operably connected to the sensor via the interposer wherein the detection system provides high dynamic range while maintaining small pixel area and low power dissipation. Thereby the invention provides methods and systems for a wafer-scale gapless and seamless detector systems with small pixels, which have both high dynamic range and low power dissipation.

Fahim, Farah↗

System and method for configuring a channel

A system and method are provided for configuring a plurality of pin resources. The method includes identifying a plurality of pin resources of a primary application specific integrated circuit (ASIC) device and configuring the plurality of pin resources based on a pin distribution between a first interface and a second interface, where the first interface provides a first communication path between the primary ASIC device and a first device, and the second interface provides a second communication path between the primary ASIC device and a second device.

Keckler, Stephen William↗

Low-power MEMS wakeup system

There is provided a near-zero-power wakeup system in which a MEMS sensor for mechanical or acoustic signals is coupled to a very-low-power complementary metal oxide semiconductor (CMOS) application-specific integrated circuit (ASIC). Power consumption can be minimized by operating the ASIC with sub-threshold gate voltages.

30 DIRECT ENERGY CONVERSION↗

SODA: a New Synthesis Infrastructure for Agile Hardware Design of Machine Learning Accelerators

Next generation systems, such as edge devices, will have to provide efficient processing of machine learning (ML) algorithms along several metrics, including energy, performance, area, and latency. However, the quickly evolving field of ML makes it extremely difficult to generate accelerators able to support a wide variety of algorithms. At the same time, designing accelerators in hardware description languages (HDLs) by hand is hard and time consuming, and does not allow quick exploration of the design space. This paper discusses the SODA synthesizer, an automated open source high-level ML framework-to-Verilog compiler targeting ML Application-Specific Integrated Circuits (ASICs) chiplets based on the LLVM infrastructure. The SODA synthesizers will allow implementing optimal designs by combining templated and fully tunable IPs and macros, and fully custom components generated through high-level synthesis. All these components will be provided through an extendable resource library, characterized with both commercial and open source logic design flows. Through a closed loop design space exploration engine, developers will be able to quickly explore their hardware designs along different dimension

Minutoli, Marco↗

Towards Automatic and Agile AI/ML Accelerator Design with End-to-End Synthesis

Domain-specific designs offer greater energy efficiency and performance gain than general-purpose processors. For this reason, modern system-on-chips have a significant portion of their silicon area with custom accelerators. However, designing hardware by hand is laborious and time-consuming, given the large design space and the performance, power, and area constraints that are not realized in the software. Moreover, domain-specific algorithms (e.g., machine learning models) are evolving quickly, challenging the accelerator design further. To address these issues, this paper presents SODA Synthesizer, an automated open-source high-level ML framework to Verilog modular compiler targeting AI/ML Application-Specific Integrated Circuits (ASICs) accelerators. SODA tightly couples the Multi- Level Intermediate Representation (MLIR) compiler infrastructure [24] and open-source HLS approaches. Thus, SODA can support various ML frameworks and algorithms and can perform optimizations that combine specialized architecture templates and conventional HLS to generate the hardware modules. In addition, SODA’s closed-loop design space exploration (DSE) engine allows developers to perform end-to-end design space explorations on different metrics and technology nodes.

Zhang, Jeff↗