Search NASA⌕ Search

SEARCH · Search NASA

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

No Galaxy Left Behind: Measuring the Transfer Function of the Dark Energy Survey with Balrog

In this dissertation, we describe a calibration and diagnostic framework called Balrog which was used to directly sample the selection and photometric biases of the Dark Energy Survey (DES) Year 3 (Y3) dataset. We systematically inject onto the single-epoch images of a random 20% subset of the DES footprint an ensemble of nearly 30 million realistic galaxy models derived from DES Deep Field observations. These augmented images are analyzed in parallel with the original data to automatically inherit measurement systematics that are often too difficult to capture with traditional generative models. The resulting object catalog is a Monte Carlo sampling of the DES transfer function and is used as a powerful diagnostic and calibration tool for a variety of DES Y3 science, particularly for the calibration of the photometric redshifts of distant "source" galaxies and magnification biases of nearer "lens" galaxies. The recovered Balrog injections are shown to closely match the photometric property distributions of the fiducial Y3 GOLD catalog, particularly in color, and capture the number density fluctuations from observing conditions of the real data within 1% for a typical galaxy sample. We find that Y3 colors are extremely well calibrated, typically within ~1-8 millimagnitudes, but for a small subset of objects we detect significant magnitude biases correlated with large overestimates of the injected object size due to proximity effects and blending. Finally, we discuss approaches to extend the current methodology to capture more aspects of the transfer function for future analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and testing of the ultraviolet spectrometer for the Mariner Mars 1971 spacecraft

The Mariner Mars 1971 ultraviolet spectrometer is an Ebert-Fastie type of the same basic design as the Mariner Mars 1969 instrument. Light enters the instrument and is split into component wavelengths by a scanning reflection diffraction grating. Two monochrometer exit slits allow the use of two independent photomultiplier tube sensors. Channel 1 has a spectral range of 1100 to 1692 A with a fixed gain, while Channel 2 has a spectral range of 1450 to 3528 A with an automatic step gain control, providing a dynamic range over the expected atmosphere and surface brightness of Mars. The scientific objectives, basic operation, design, testing, and calibration for the Mariner Mars 1971 ultraviolet spectrometer are described. The design discussion includes those modifications that were necessary to extend the lifetime of the instrument in order to accomplish the Mariner Mars 1971 mission objectives.

Farrar, J. W.↗

Pulsed Plasma Thruster (PPT) Technology: Earth Observing-1 PPT Operational and Advanced Components Being Developed

In 2002 the pulsed plasma thruster (PPT) mounted on the Earth Observing-1 spacecraft was operated successfully in orbit. The two-axis thruster system is fully incorporated in the attitude determination and control system and is being used to automatically counteract disturbances in the pitch axis of the spacecraft. The first tests conducted in space demonstrated the full range of PPT operation, followed by calibration of control torques from the PPT in the attitude control system. Then the spacecraft was placed in PPT control mode. To date, it has operated for about 30 hr. The PPT successfully controlled pitch momentum during wheel de-spin, solar array acceleration and deceleration during array rewind, and environmental torques in nominal operating conditions. Images collected with the Advanced Landsat Imager during PPT operation have demonstrated that there was no degradation in comparison to full momentum wheel control. In addition, other experiments have been performed to interrogate the effects of PPT operation on communication packages and light reflection from spacecraft surfaces. Future experiments will investigate the possibility of orbit-raising maneuvers, spacecraft roll, and concurrent operation with the Hyperion imager. Future applications envisioned for pulsed plasma thrusters include longer life, higher precision, multiaxis thruster configurations for three-axis attitude control systems or high-precision, formationflying systems. Advanced components, such as a "dry" mica-foil capacitor, a wear-resistant spark plug, and a multichannel power processing unit have been developed under contract with Unison Industries, General Dynamics, and C.U. Aerospace. Over the last year, evaluation tests have been conducted to determine power processing unit efficiency, atmospheric functionality, vacuum functionality, thruster performance evaluation, thermal performance, and component life.

Pencil, Eric J.↗

Uncertainty Quantification Enabled by Automatic Differentiation for Hydrodynamic Simulation of Shock‐to‐Detonation Transition in High Explosives

Quantifying the effects of uncertainty in a reactive burn model on the run-to-detonation time in high explosives (HEs) provides a robust methodology for assessing the probability of an HE failing the IHE qualification standard. Moreover, uncertainty quantification helps evaluate whether the model calibration accurately represents data outside the calibration set. This study uses a specialized hydrodynamic simulation code for modeling detonation to determine the run-to-detonation time of the HE PBX 9502 for various impact velocities. To quickly approximate uncertainties in the model, a surrogate was constructed using a Taylor series expansion centered at the mean of the input parameters. To obtain the sensitivities required for constructing the Taylor series, HYP-percomplex Automatic Differentiation (HYPAD) was implemented. HYPAD is a methodology for infusing existing codes with automatic differentiation capabilities by augmenting variables with one or more imaginary units to compute step-size independent partial derivatives. These derivatives are accurate to machine precision with respect to the implemented numerical algorithm, meaning their accuracy reflects that of the underlying method (e.g., integration or discretization schemes). Using reduced order modeling techniques, the mean and standard deviation of the run-to-detonation time of a shock within PBX 9502 were computed for a number of initial impact velocities. A weighted least squares regression was then performed to obtain a best fit curve and prediction interval for the computed statistics. Historical data points from explosively driven wedge tests were utilized to validate the prediction interval, ensuring its reliability in predicting future outcomes. With this prediction interval and a known safety constraint curve, the most probable point of failure and the probability of failure for the HE PBX 9502 were determined.

97 MATHEMATICS AND COMPUTING↗

Dark Energy Survey Year 3 Results: Galaxy mock catalogs for BAO analysis

The calibration and validation of scientific analysis in simulations is a fundamental tool to ensure unbiased and robust results in observational cosmology. In particular, mock galaxy catalogs are a crucial resource to achieve these goals in the measurement of baryon acoustic oscillation (BAO) in the clustering of galaxies. Here we present a set of 1952 galaxy mock catalogs designed to mimic the Dark Energy Survey Year 3 BAO sample over its full photometric redshift range 0.6 < zphoto < 1.1. The mocks are based upon 488 ICE-COLA fast N-body simulations of full-sky light cones and were created by populating halos with galaxies, using a hybrid halo occupation distribution – halo abundance matching model. This model has ten free parameters, which were determined, for the first time, using an automatic likelihood minimization procedure. We also introduced a novel technique to assign photometric redshift for simulated galaxies, following a two-dimensional probability distribution with VIMOS Public Extragalactic Redshift Survey data. The calibration was designed to match the observed abundance of galaxies as a function of photometric redshift, the distribution of photometric redshift errors, and the clustering amplitude on scales smaller than those used for BAO measurements. An exhaustive analysis was done to ensure that the mocks reproduce the input properties. Finally, mocks were tested by comparing the angular correlation function w(θ), angular power spectrum Cℓ, and projected clustering ξp(r⊥) to theoretical predictions and data. The impact of volume replication in the estimate of the covariance is also investigated. The success in accurately reproducing the photometric redshift uncertainties and the galaxy clustering as a function of redshift render this mock creation pipeline as a benchmark for future analyses of photometric galaxy surveys.Key words: catalogs / large-scale structure of Universe / galaxies: distances and redshifts / Galaxy: halo / methods: numerical

79 ASTRONOMY AND ASTROPHYSICS↗

Conference on Applications of Digital Image Processing to Astronomy, Pasadena, Calif., August 20-22, 1980, Proceedings

The astronomic applications of non-military digital image processing are covered in this conference volume. Systems like CCD's, interactive data analysis facilities, stellar speckle interferometry, sky flux subsystems, guide star systems and various image processing systems are described. Techniques in photometry including filtering, automatic photometry, and image restoration are examined. Digital spectral analyses of galaxies, supernova remnants, stars and other celestial bodies are discussed together with algorithms developed to calibrate, clean up, enhance, and quantitatively analyze data. The techniques of image processing permit astronomers to make much more efficient use of their data for both subjective and quantitative analyses. Future missions, such as the Space Telescope, representing a vast data base are briefly covered.

Elliott, D. A.↗

Compact piezoelectric resonance mass balance for sample verification and mass quantification and mixing.

There is a need for sample verification and mass quantification of rock, soil and/or ice obtained by sample acquisition mechanisms on extraterrestrial bodies. For many scientific instruments information about the mass of the sample would aid in the interpretation of the data and help prevent the portioning system from overloading instrument ports. Additionally, on a potential sample return mission it is likely that a sample confirmation or mass determination requirement would be implemented before the spacecraft would be commanded to return to Earth or Lunar orbit. In an effort to meet these potential requirements, a piezoelectric resonance balance is being developed to measure a frequency change proportional to the sample mass change. In previous work1 we developed a resonance balance which produced large non-linear frequency changes due to the addition of a large mass. In this study we have looked at a variety of resonator geometries in an effort to linearize the frequency shift with mass. In addition, we have investigated the use of oscillator/counter circuitry to track the frequency shift of the piezoelectric mass balance. In this new design the frequency shifts automatically when a mass is placed on the balance and the counter circuit calculates the frequency shift. This frequency is then converted to a mass using calibration tables determined previously. An additional feature we have implemented is the use of a high frequency thickness mode piezoelectric resonator to mix the sample and a reactant or solvent. This allows for measuring both sample and reagent prior to ingestion by the instrument. This paper will focus on the design requirements and how they are affected by the local gravity and acoustic properties of the sample. Designs which allow for easy loading and unloading of the balance will also be discussed.

Yahnker, Christopher R.↗

Imaging of Calibrated Defects in Additively Manufactured Materials: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. Currently, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. As a solution to NDE of AM, we are developing pulsed thermal imaging which is non-contact, one-sided, and scalable to arbitrary size and shape of the AM parts. Pulsed thermography (PT) system utilizes a high intensity flash lamp to rapidly heat surface of sample, and a high sensitivity fast-frame megapixel infrared (IR) camera to capture data of surface temperature variations. The acquired data cube consists of a stack of surface temperature images taken at different times. Information about material internal defects is extracted by analyzing the data cube. This report provides results of preliminary performance evaluation of pulsed thermal imaging capability in detection of imprinted flaws in AM metallic structures. The flaws were introduced into AM parts as imprinted hemispherical low density regions, consisting of trapped un-sintered metallic powder. Specimens for developed for this study consisted of AM stainless steel 316 and Inconel 718 plates. The diameters of imprinted defects varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. Pulsed thermal tomography (PTT) processes the measured data cube to obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. PTT has been previously used in imaging of similar size flat bottom hole (FBH) simulated defects in stainless steel 316 and Inconel 718 specimens. In the study involving AM specimens, PTT imaging results have shown that 1mm-diameter defects located 1mm and 2mm below the surface of specimens were detectable. Larger size defects were detectable at greater depth. We also explored an alternative approach to detection of material flaws in PT data cube, which is using neural learning-based approach to blind source separation. Detection of small material defects requires finding features in the data cube which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with phtotothermics, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

36 MATERIALS SCIENCE↗

Challenges in modeling the X-29 flight test performance

Presented are methods, instrumentation, and difficulties associated with drag measurement of the X-29A aircraft. The initial performance objective of the X-29A program emphasized drag polar shapes rather than absolute drag levels. Priorities during the flight envelope expansion restricted the evaluation of aircraft performance. Changes in aircraft configuration, uncertainties in angle-of-attack calibration, and limitations in instrumentation complicated the analysis. Limited engine instrumentation with uncertainties in overall in-flight thrust accuracy made it difficult to obtain reliable values of coefficient of parasite drag. The aircraft was incapable of tracking the automatic camber control trim schedule for optimum wing flaperon deflection during typical dynamic performance maneuvers; this has also complicated the drag polar shape modeling. The X-29A was far enough off the schedule that the developed trim drag correction procedure has proven inadequate. However, good drag polar shapes have been developed throughout the flight envelope. Preliminary flight results have compared well with wind tunnel predictions. A more comprehensive analysis must be done to complete performance models. The detailed flight performance program with a calibrated engine will benefit from the experience gained during this preliminary performance phase.

John W Hicks↗

Challenges in modeling the X-29A flight test performance

The paper presents the methods, instrumentation, and difficulties associated with drag measurement of the X-29A aircraft. The initial performance objective of the X-29A program emphasized drag polar shapes rather than absolute drag levels. Priorities during the flight envelope expansion restricted the evaluation of aircraft performance. Changes in aircraft configuration, uncertainties in angle-of-attack calibration, and limitations in instrumentation complicated the analysis. Limited engine instrumentation with uncertainties in overall in-flight thrust accuracy made it difficult to obtain reliable values of coefficient of parasite drag. The aircraft was incapable of tracking the automatic camber control trim schedule for optimum wing flaperon deflection during typical dynamic performance maneuvers; this has also complicated the drag polar shape modeling. The X-29A was far enough off the schedule that the developed trim drag correction procedure has proven inadequate. Despite these obstacles, good drag polar shapes have been developed throughout the flight envelope. Preliminary flight results have compared well with wind tunnel predictions. A more comprehensive analysis must be done to complete the performance models. The detailed flight performance program with a calibrated engine will benefit from the experience gained during this preliminary performance phase.

Hicks, John W.↗

Construction and performance characteristics of a prototype NBS/GPS receiver

The construction and performance characteristics of a low-cost, high-accuracy GPS C/A receiver are reviewed. The receiver takes advantage of a simultaneous common view of the same satellites, which could allow time transfer with accuracies on the order of 10 ns or less for baselines as large as 3000 km. Frequency can be measured to better than one part in 10 to the 14th. The software and the receiver are configured to be fully automatic with a Z80A microprocessor setting the amplitude for the lock loops of the receiver and setting the synthesizer with corrects for Doppler shift. The microprocessor can calibrate a 0.1 ns built-in time interval counter.

Davis, D. D.↗

NASA Tech Briefs, December 2006

Topic include: Inferring Gear Damage from Oil-Debris and Vibration Data; Forecasting of Storm-Surge Floods Using ADCIRC and Optimized DEMs; User Interactive Software for Analysis of Human Physiological Data; Representation of Serendipitous Scientific Data; Automatic Locking of Laser Frequency to an Absorption Peak; Self-Passivating Lithium/Solid Electrolyte/Iodine Cells; Four-Quadrant Analog Multipliers Using G4-FETs; Noise Source for Calibrating a Microwave Polarimeter; Hybrid Deployable Foam Antennas and Reflectors; Coating MCPs with AlN and GaN; Domed, 40-cm-Diameter Ion Optics for an Ion Thruster; Gesture-Controlled Interfaces for Self-Service Machines; Dynamically Alterable Arrays of Polymorphic Data Types; Identifying Trends in Deep Space Network Monitor Data; Predicting Lifetime of a Thermomechanically Loaded Component; Partial Automation of Requirements Tracing; Automated Synthesis of Architecture of Avionic Systems; SSRL Emergency Response Shore Tool; Wholly Aromatic Ether-Imides as n-Type Semiconductors; Carbon-Nanotube-Carpet Heat-Transfer Pads; Pulse-Flow Microencapsulation System; Automated Low-Gravitation Facility Would Make Optical Fibers; Alignment Cube with One Diffractive Face; Graphite Composite Booms with Integral Hinges; Tool for Sampling Permafrost on a Remote Planet; and Special Semaphore Scheme for UHF Spacecraft Communications.

Source record↗

Design considerations for a Digital Twin built to improve nitrification performance at a water resource recovery facility

A Digital Twin built around Activated Sludge Model No. 1 was deployed at a full-scale water resource recovery facility. Its design included a waste rate recommender system based on automatic scenario analyses, where influent loads and waste rates are varied to determine their impact on nitrification. At the same frequency as these scenario analyses, scheduled auto-calibrations allow for nitrifier maximum specific growth rate (μmax-NITO) soft sensing, the only kinetic parameter shown to require adjustment if the objective is aeration tank effluent ammonia forecasting accuracy. By integrating temperature forecasting over the next three sludge ages, this Digital Twin approach creates opportunities for advancing waste rate decisions in anticipation of seasonal temperature changes, optimizing ammonia control authority under varying influent loads, and furnishing valuable insights for future capital projects requiring nitrifier kinetic understanding and modelling.

54 ENVIRONMENTAL SCIENCES↗

Nondestructive Test Probe

Under the Aircraft Structural Integrity program, Langley Research Center invented a device to detect fatigue cracks in aluminum alloy plates. Krautkramer Branson obtained an exclusive license and commercialized a hand-held device, the "CrackFinder," an electromagnetic probe for nondestructive evaluation, used to scan aircraft skins for surface breaks. The technology involves an eddy current, which is an electrical current induced by an alternating magnetic field. The CrackFinder also employs an innovative self-nulling feature, where the device automatically recalibrates to zero so that each flaw detected produces a reading. Compared to conventional testing systems, the CrackFinder is affordable, small, simple to use, and needs no calibration.

Source record↗

Flight Characteristics of a 1/4-Scale Model of the XFV-1 Airplane (TED No. NACA DE-378)

A l/4-scale dynamically similar model of the XFV-1 airplane has been flown in the Ames 40- by 80-foot wind tunnel, using the trailing flight-cable technique. This investigation was devoted to establishing the flight characteristics of the model in forward flight from hovering to wing stall, and in yawed flight (wing span alined with the relative wind) from hovering to the maximum speed at which controlled flight could be maintained. Landings, take-offs, and hovering characteristics in flights close to the ground were also investigated.. Since the remote control system for the model was rather complicated and provided artificial damping about the pitch, roll, and yaw axes, sufficient data from the control-system calibration tests are included in this report to specify the performance of the control system in relation to both the model flight tests and the design of an automatic control system for the full-scale airplane. The model in hovering flight appeared to be neutrally stable. The response of the model to the controls was very rapid, and it was always necessary to provide some amount of artificial damping to maintain control. The model could be landed with little difficulty by hovering approximately a foot above the floor and then cutting the power. Take-offs were more difficult to perform, primarily because the rate of change in power to the model motors was limited by the characteristics of the available power source. The model was,capable of controlled yawed flight at translational velocities up to and including 20 feet per second. The effectiveness of the controls decreased with increasing speed, however, and at 25 fps control in pitch, and probably roll, was lost completely. The model was flown in controlled forward flight from hovering up to 70 fps. During these flights the model appeared to be more difficult to control in yaw than it was in pitch or roll. The flights of the model were recorded by motion picture cameras. These motion pictures are available on loan from NACA Headquarters as a film supplement to this report.

Kelly, Mark W.↗

Automated model generation and parameter estimation of building energy models using an ontology-based framework

This study presents a methodology for automated model generation and parameter estimation of building energy models using semantic modeling and Bayesian estimation. Semantic modeling techniques are used to represent the system components and their interactions, facilitating the automatic generation of a simulation model from dynamic component models. The proposed approach is applied to a case study of a ventilation system where a simulation model is generated, calibrated, and assessed through different performance metrics. These metrics demonstrate the accuracy and reliability of both model point estimates and probabilistic prediction intervals across all model outputs. Overall, the proposed methodology offers a systematic and automated approach to model development and calibration in building energy systems, with potential applications in building performance analysis, monitoring, and optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ionospheric corrections to precise time transfer using GPS

The free electrons in the earth's ionosphere can retard the time of reception of GPS signals received at a ground station, compared to their time in free space, by many tens of nanoseconds, thus limiting the accuracy of time transfer by GPS. The amount of the ionospheric time delay is proportional to the total number of electrons encountered by the wave on its path from each GPS satellite to a receiver. This integrated number of electrons is called Total Electron Content, or TEC. Dual frequency GPS receivers designed by Allen Osborne Associates, Inc. (AOA) directly measure both the ionospheric differential group delay and the differential carrier phase advance for the two GPS frequencies and derive from this the TEC between the receiver and each GPS satellite in track. The group delay information is mainly used to provide an absolute calibration to the relative differential carrier phase, which is an extremely precise measure of relative TEC. The AOA Mini-Rogue ICS-4Z and the AOA TurboRogue ICS-4000Z receivers normally operate using the GPS P code, when available, and switch to cross-correlation signal processing when the GPS satellites are in the Anti-Spoofing (A-S) mode and the P code is encrypted. An AOA ICS-Z receiver has been operated continuously for over a year at Hanscom AFB, MA to determine the statistics of the variability of the TEC parameter using signals from up to four different directions simultaneously. The 4-channel ICS-4Z and the 8-channel ICS-4000Z, have proven capabilities to make precise, well calibrated, measurements of the ionosphere in several directions simultaneously. In addition to providing ionospheric corrections for precise time transfer via satellite, this dual frequency design allows full code and automatic codeless operation of both the differential group delay and differential carrier phase for numerous ionospheric experiments being conducted. Statistical results of the data collected from the ICS-4Z during the initial year of ionospheric time delay in the northeastern U.S., and initial results with the ICS-4000Z, will be presented.

Snow, Robert W.↗

Neural Learning Based Blind Source Separation for Detection of Material Defects in Pulsed Thermography Images

In this paper, we introduce a neural learning-based approach to blind source separation for detection of material flaws in pulsed thermography (PT) images. This approach can be used to detect internal defects (pores) in metallic Additively Manufactured (AM) materials. Such defects occur in high-strength alloys produced with direct laser sintering AM method for nuclear energy applications. Pulsed thermal imaging system utilizes a high intensity flash lamp to rapidly heat surface of sample, a high sensitivity infrared camera to capture data of surface temperature variations. The data cube obtained with PT (stack of surface temperature images at different times) can be analyzed with image processing algorithms to detect material defects. Compared with conventional nondestructive evaluation (NDE) methods, such as digital radiography and ultrasonic testing, the PT pulsed infrared thermal detection technique has advantages of one-sided non-contact measurements, fast processing of large sample areas captured in one image. Detection of small material defects requires finding features in thermal images, which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with the photothermic, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

Zhang, Xin↗