Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery charge controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Achieving a high-performance sodium-ion pouch cell by regulating intergrowth structures in a layered oxide cathode with anionic redox

In P2-type layered transition metal (TM) oxides, which are typical cathode materials for Na-ion batteries, the presence of Li within the TM layer could lead to the formation of specific Na–O–Li configurations that trigger additional oxygen redox at high charging voltages. However, the prismatic-type (P-type) to octahedral-type (O-type) phase transition and irreversible TM migration could be simultaneously aggravated in high state of charge, resulting in structural distortion. Here we demonstrate that excessive desodiation of P2-Na 0.67 Li 0.1 Fe 0.37 Mn 0.53 O 2 (NLFMO) induces the formation of neighbouring O-type stacking faults with an intergrowth structure (that is, interlacing of O- and P-type layers), which leads to out-of-lattice Li migration and irreversible oxygen loss. We show that, by controlling the depth of charge to tailor the intergrowth structure, a P-type stacking state can be uniformly interspersed between the O-type stacking state, thereby avoiding neighbouring O-type stacking faults. Adjusting the O/P intergrowth structure leads to both reversible migration of Li/TM ions and reversible anionic redox in the NLFMO cathode. In conclusion, we thereby achieve a high-performance pouch cell (with an energy density of 165 W h kg −1 based on the entire weight of the cell) with both cationic and anionic redox activities.

25 ENERGY STORAGE↗

Exploring Lead Zirconate Titanate, the Potential Advancement as an Anode for Li-Ion Batteries

Graphite, widely adopted as an anode for lithium-ion batteries (LIBs), faces challenges such as an unsustainable supply chain and sluggish rate capabilities. This emphasizes the urgent need to explore alternative anode materials for LIBs, aiming to resolve these challenges and drive the advancement of more efficient and sustainable battery technologies. The present research investigates the potential of lead zirconate titanate (PZT: PbZr 0.53 Ti 0.47 O 3 ) as an anode material for LIBs. Bulk PZT materials were synthesized by using a solid-state reaction, and the electrochemical performance as an anode was examined. A high initial discharge capacity of approximately 686 mAh/g was attained, maintaining a stable capacity of around 161 mAh/g after 200 cycles with diffusion-controlled intercalation as the primary charge storage mechanism in a PZT anode. These findings suggest that PZT exhibits a promising electrochemical performance, positioning it as a potential alternative anode material for LIBs.

25 ENERGY STORAGE↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding the Cathode Electrochemistry of Humidified Solid‐State Lithium‐Oxygen Batteries

Lithium-oxygen batteries (LOBs) possess a high theoretical energy density, making them potential candidates for next-generation energy storage. However, challenges such as reactive oxygen species-induced component degradation hinder their practical use. Inorganic solid-state electrolytes offer an alternative to degradation-prone aprotic electrolytes, while also protecting lithium anodes from potential atmospheric reactants. Here, this study explores the cathode electrochemistry of solid-state LOBs using humidified oxygen, which forms an aqueous catholyte during initial cycling, thereby improving cathode-electrolyte contact. To quantitatively analyze the cathode electrochemistry, a ‘Humidity-Incorporated’ Differential Electrochemical Gas Monitoring System (HiDEMS) is developed to control humidity and monitor gas consumption and evolution in real time. When studying a Li-O 2 cell that employs a NASICON-type Li 1.3 Al 0.3 Ti 1.7 (PO 4 ) 3 (LATP) solid electrolyte and a porous carbon cathode, a shift in discharge products from Li 2 O 2 to LiOH is observed over repeated cycles. While Li 2 O 2 evolves O 2 during charging, LiOH oxidation leads to minimal O 2 release and increased CO 2 production, originating from oxidation of carbon electrodes. Further, dissolution of Al and P from LATP is observed, likely driven by the formation of the alkaline catholyte. The findings highlight the need for carbon-free cathode materials and more stable solid-state conductors to minimize side reactions and improve rechargeability in humidified solid-state Li-O 2 batteries.

LATP degradation↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Layer-by-Layer Nanoarchitectonics of Electrochemically Active Thin Films Comprised of Radical-Containing Polymers

Electroactive coatings based on non-conjugated redox-active polymers have increased in popularity with the development of thin film organic batteries. Here, control over coating deposition, redox-activity, and ion transport are key to improving their energy storage performance. In this work, the synthesis, solution state electrochemical characterization, and layer-by-layer (LbL) assembly of a nitroxide-based polycation and polyanion are presented. Solution state electrochemical characterization indicates that the rate of electron transfer for the nitroxide polyanion is much higher as compared to the nitroxide polycation. LbL thin films of the nitroxide polyanion and nitroxide polycation are assembled, demonstrating linear growth and tunable thickness (28 nm/layer pair). This work confirms that the ion transport mechanism of the LbL films during the redox reaction is influenced depending on the charge of the terminating layer, where the nitroxide polyanion can participate in self-doping, which leads to a contribution from cation transport. The nitroxide polyanion-terminated film also exhibits a higher capacity and a slightly reduced charge transfer resistance. However, it was also observed that a more pronounced capacity fade occurred for the polyanion-terminated film than the polycation-terminated film. Taken together, this highlights how oppositely charged radical-containing polyelectrolytes can form electroactive coatings for possible applications in energy storage or sensing.

25 ENERGY STORAGE↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

OCHRE

OCHRE™ uses a variety of input data sources to run time-series simulations. Building models can be taken from the ResStock™ database or generated using the Building Energy Optimization Tool (BEopt™) or other OpenStudio-HPXML workflows. EV charging profiles can be taken from datasets used in NLR's 2030 National Charging Network project. Weather data can be taken from the National Solar Radiation Database or EnergyPlus® weather files. There are no public datasets with OCHRE outputs at this time. However, a recent project dataset on water heater and EV demand flexibility can be requested. OCHRE is a Python-based energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, EVs, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal charging scheduling and management for a fast-charging battery electric bus system

Herein we discuss how battery electric buses (BEBs) are rapidly being embraced by public transit agencies because of their environmental and economic benefits. To address the problems of limited driving range and time-consuming charging for BEBs, manufacturers have developed rapid on-route charging technology that utilizes typical layovers at terminals to charge buses in operation using high power. With on-route fast-charging, BEBs are as capable as their diesel counterparts in terms of range and operating time. However, on-route fast-charging makes it more challenging to schedule and manage charging events for a BEB system. First, on-route fast-charging may lead to high electricity power demand charges. Second, it may increase electricity energy charges because of charging that occurs during on-peak hours. Without careful charging scheduling and management, on-route fast-charging may significantly increase fuel costs and reduce the economic attractiveness of BEBs. The present study proposes a network modeling framework to optimize the charging scheduling and management for a fast-charging BEB system, effectively minimizing total charging costs. The charging schedule determines when to charge a BEB, while the charging management strategically controls the actual charging power. Charging costs include both electricity demand charges and energy charges. The charging scheduling and management problem is first formulated as a nonlinear nonconvex program with time-continuous variables. A discretizing method and a linear reformulation technique are then adopted to reformulate the model as a linear program, which can be easily solved using off-the-shelf solvers, even for large-scale problems. Finally, the model is demonstrated with extensive numerical studies based on two real-world bus networks. The results demonstrate that the proposed model can effectively determine the optimal charging scheduling and management for a fast-charging BEB system, which carries the potential for use in large-scale real-world bus networks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗

Correlation Between Microscopic Current Fluctuations Observed at Ultra-Microelectrodes and Macroscopic Bulk Electrolysis Performance in Redox-Active Microemulsions

Microemulsions (μEs) have been proposed as redox flow battery (RFB) electrolytes that maximize ionic conductivity and charge capacity by synergizing two immiscible phases. However, charge transfer during electrolysis in μEs is poorly understood. Here, we show that ultramicroelectrode electrolysis of ferrocene-loaded μEs –20%, 60%, and 90% water - reveals stochastic current fluctuations. These are differentiated in the scanning electrochemical microscopy (SECM) geometry, where power spectral density analysis showed distinct changes in the frequency contributions. SECM in the substrate generation-tip collection mode showed that fluctuations arise under mass-transfer control. Significant differences in the diffusion coefficient of ferrocene species were deducted from SECM approach curves, suggesting phase transfer behavior. Using bulk electrolysis, we calculated the charge accessibility and cycling behavior in the μEs. A decrease in the stochastic behavior of the μEs seems to correlate to a higher accessibility and cycling performance, with the 90% water μE displaying the best reversibility and the 60% the lowest. Altogether, these results suggest that Marangoni-type convection driven by concentration gradients and/or μE restructuring during charge transfer play a role in the electrochemical performance of μEs. This presents opportunities for screening and diagnosing the performance of these emerging RFB electrolytes.

25 ENERGY STORAGE↗

Boosting the sodium storage behaviors of carbon materials in ether-based electrolyte through the artificial manipulation of microstructure

The porous carbon blacks rationally designed by a facile yet efficient NH 3 thermal etching route have been investigated as anode materials in an ether-based electrolyte for sodium-ion batteries. The as-synthesized CBN35 carbon black with a 35% weight loss after NH3 thermal etching exhibited a large specific charge capacity of 352 mAh g -1 at 50 mA g -1 and a superior rate capability of 101 mAh g -1 at 16000 mA g -1 , due to its highest microporosity, an appropriate surface area, a desirable microstructure, and a promising hybrid intercalation mechanism. Impressively, even cycled at 1600 mA g -1 over 3200 cycles, an outstanding reversible capacity of 103 mAh g -1 with a negligible 0.0162% capacity loss per cycle can still be achieved. Based on the multimodal characterizations including the structural probes of phase evolution for carbon materials, the electrochemical techniques, and the surface-sensitive XAS measurements, the exceptional electrochemical properties should stem from several merits of modified carbon black system. While the particular microporous structure provides relatively more accessible sodium storage sites, a novel hybrid intercalation mechanism in ether-based electrolyte would incorporate the sodium ion insertion into the disordered structure with the solvated sodium ion species co-intercalation into the graphitic phase. In addition to the diffusion-controlled redox reactions, the noticeable surface-induced pseudocapacitive reactions also significantly contribute to the charge storage upon sodiation and guarantee the rapid migrations of sodium ions/solvated compounds. In conclusion, this system further features a controlled emergence of a robust but thin solid electrolyte interphase layer, which could suppress the side reactions of active electrode with reactive electrolyte, maintain the fragile porous structure upon cycling, and facilitate the migrations of sodium ions and solvated sodium ion compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational study of the adsorption of bimetallic clusters on alumina substrate

We performed computational investigation of the adsorption of bimetallic Pd 3 M 2 (where M changes from Ag, Au, Co, Cu, Mn, Ni, Pt, and Ru) cluster on the hydroxylated alumina surface. Previously, it was shown that small silver cluster can control the rate of discharge at the cathode of lithium-oxygen battery. The gap near the fermi energy was shown to control the oxygen reduction, an important reaction for LiO 2 formation. Controlling the gap would ultimately control the rate of LiO 2 formation. One can vary the size of the cluster to vary the gap, however, this "knob" provides limited variance in the gap. Alloying, in combination with size variation offer a much wider control of the gap, hence the LiO 2 formation. Using Density Functional Theory (DFT), we determined the most stable geometry of the bimetallic clusters Pd 3 M 2 and calculated the binding energies of these clusters on the alumina substrate which ranges from 0.2 eV to 0.25 eV depending upon the composition of the alloy-cluster, its orientation and the adsorption site. We also find that Pd atoms bind strongly with the substrate oxygen atoms with an average short bond-length of about 2.2 angstrom. We explored how the gap at the Fermi level of the system varies as a function of elemental composition and the calculated gap ranges from 0 meV to 90 meV. Charges distribution using Bader analysis was also performed to probe how charges are transferred between the cluster and the substrate. These preliminary results will open the door for more systematic studies of alloy clusters of different size and stoichiometry for Li-O 2 battery cathode design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Opportunities and Challenges to Capturing Distributed Battery Value via Retail Utility Rates and Programs

Distributed battery deployment is increasing with advanced metering, control, and communication technologies, leaving electric utilities with an under-utilized, flexible grid resource in aggregate. Rates can reflect locational and temporal prices while utility incentive-based programs allow DERs to provide direct grid services. However, utilities must balance accurately reflecting dynamic grid conditions versus simple and feasible design that encourages customer participation. Currently, most rates and incentive-based programs are simple, but as penetration of DER and advanced controls increase, dynamic designs could become prevalent. Utilities could encourage providing multiple services to optimize distributed battery dispatch and value streams, however, challenges persist when stacking services across distribution and bulk systems. A DER committed to multiple discrete services concurrently necessitates coordination between operators and a clear hierarchy of commitments. One way to address this is to separate commitments by time or capacity. For services that follow cyclic, predictable patterns, or those that are peak driven with predictability, an operator could ensure sufficient state of charge for participation, leaving time where a distributed battery could otherwise provide different services by segmenting participation temporally. To provide continuous or unexpected services, a battery operator may use state of charge management to reserve some percentage of the battery and segment participation by capacity. Macroeconomic trends, load patterns, generation profiles, and grid configurations drive variation in value and the subsequent implications for utility offerings and how a customer might participate. As distributed battery adoption increases, both regulators and utilities will need to ensure no adverse grid impacts and encourage provision of societal value beyond the customer domain.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2022 Component Innovation Awardee: Windurance

Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.

CIP↗

Dimolybdenum Paddlewheel Complexes with Cation Binding Sites as Electrolyte Additives to Manipulate the Solid-Electrolyte Interphase at Lithium Metal Anodes

The use of electrolyte additives at millimolar loadings to control the surface chemistry of lithium metal anodes (LMAs) is a leading strategy to improve lithium metal batteries and promote electrosynthetic reactions. Whereas previous studies employed either inorganic or organic additives, in this study, we report the first organometallic additive, Mo 2 (mea) 4 [1, mea = 2-(2-methoxyethoxy)acetate], a dimolybdenum paddlewheel complex that is stable under Li plating conditions and features cation binding sites in the second coordination sphere that promote reversible Li + coordination. Binding of Li + ions to 1 induces immobilization of cationically charged aggregates (or products thereof) into the solid electrolyte interphase (SEI), imparting multiple beneficial functions. The modified SEI was found to protect the LMA against parasitic side reactions, produce modest but measurable improvements to Li plating properties (e.g., overpotential, surface structure, and Coulombic efficiency), and improve interfacial charge transport properties. Furthermore, the most notable benefit to battery cycling performance appears in calendar aging tests, which show that the presence of the additive protects the LMA from parasitic side reactions that would otherwise decrease overall cell cycling efficiency over time. Collectively, these data disclose a tactic for designing electrolyte additives using principles of organometallic synthesis.

Additives↗

Improved Capacity Retention of Lithium Ion Batteries under Fast Charge via Metal-Coated Graphite Electrodes

A primary barrier preventing repetitive fast charging of Li-ion batteries is lithium metal plating at the graphite anode. One approach toward mitigating Li metal deposition is the deliberate modification of the graphite anode surface with materials demonstrating high overpotentials unfavorable for Li metal nucleation, such as Ni or Cu nanoscale films. This research explores Ni and Cu surface coatings at different areal loadings (3 or 11 μg cm -2 ) on the electrochemistry of graphite/LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) type Li-ion batteries. Extended galvanostatic cycling of control and metal-coated electrodes in graphite/NMC622 pouch cells are conducted under high rate conditions. Based on the overpotential of Li deposition on metal foil, both Ni and Cu treatments were anticipated to result in reduced lithium deposition. The higher metal film loadings of 11 μg cm -2 Ni- or Cu-coated electrodes exhibit the highest capacity retention after 500 cycles, with mean improvements of 8% and 9%, respectively, over uncoated graphite electrodes. Li plating quantified by X-ray diffraction indicates that the metal films effectively reduce the quantity of plated Li compared to untreated electrodes, with 11 μg cm -2 Cu providing the greatest benefit.

25 ENERGY STORAGE↗

On the Electrochemical Properties of Carbon-Coated NaCrO 2 for Na-Ion Batteries

NaCrO 2 is a promising cathode for Na-ion batteries. However, further studies of the mechanisms controlling its specific capacities and cycle stability are needed for real-world applications in the future. This study reveals, for the first time, that the typical specific capacity of ~110 mAh/g reported by many researchers when the charge/discharge voltage window is set between 2.0 and 3.6 V vs. Na/Na + is actually controlled by the low electronic conductivity at the electrode/electrolyte interface. Through wet solution mixing of NaCrO 2 particles with carbon precursors, uniform carbon coating can be formed on the surface of NaCrO 2 particles, leading to unprecedented specific capacities at 140 mAh/g, which is the highest specific capacity ever reported in the literature with the lower and upper cutoff voltages at the aforementioned values. However, such carbon-coated NaCrO 2 with ultrahigh specific capacity does not improve cycle stability because with the specific capacity at 140 mAh/g the Na deintercalation during charge is more than 50% Na ions per formula unit of NaCrO 2 which leads to irreversible redox reactions. The insights from this study provide a future direction to enhance the long-term cycle stability of NaCrO 2 through integrating carbon coating and doping.

25 ENERGY STORAGE↗