Search NASA⌕ Search

SEARCH · Search NASA

Results for “bedding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Changes in body fluid compartments during a 28-day bed rest

Serial isotope measurements were used to obtain measurements of the body fluid responses of 10 22-29-year-old men during 28 d of simulated microgravity (bed rest). The subjects were maintained on a controlled metabolic diet for 7 d before the study, during 14 d of ambulatory control, 28 d of horizontal bed rest, and 14 d of ambulant recovery. Fluid compartments were measured on control days 1 and 9, bed rest days 2, 14, and 28, and recovery days 7 and 14. By day 2 of bed rest, plasma volume and extracellular volume (ECV) decreased significantly by an average 209 and 533 ml, respectively. Red cell volume and total body water (TBW) decreased more slowly, with average losses of 128 and 1316 ml, respectively, after 28 d of bed rest. Early in the bed rest, TBW loss was mostly from the ECV. Thereafter, the TBW deficit was derived from the intracellular compartment, which decreased an average of 838 ml after 28 d. These results suggest losses from all fluid compartments during bed rest, with no evidence of restoration of ECV after 1-2 weeks.

Fortney, Suzanne M.↗

The development of test beds to support the definition and evolution of the Space Station Freedom power system

Since the beginning of the Space Station Freedom Program (SSFP), the NASA Lewis Research Center (LeRC) and the Rocketdyne Division of Rockwell International have had extensive efforts underway to develop testbeds to support the definition of the detailed electrical power system design. Because of the extensive redirections that have taken place in the Space Station Freedom Program in the past several years, the test bed effort was forced to accommodate a large number of changes. A short history of these program changes and their impact on the LeRC test beds is presented to understand how the current test bed configuration has evolved. The current test objectives and the development approach for the current DC test bed are discussed. A description of the test bed configuration, along with its power and controller hardware and its software components, is presented. Next, the uses of the test bed during the mature design and verification phase of SSFP are examined. Finally, the uses of the test bed in the operation and evolution of the SSF are addressed.

Soeder, James F.↗

Orthostatic intolerance during a 13-day bed rest does not result from increased leg compliance

Increased leg compliance (LC) has been proposed as a mechanism for orthostatic intolerance after spaceflight or bed rest. Using venous occlusion plethysmography with mercury-in-Silastic strain gauge, we evaluated LC before, during, and after a 13-day head-down bed rest in 10 men. LC was measured by the relationship between the increased calf areas at thigh cuff occlusions of 20, 30, 50, 70, and 80 mmHg. Orthostatic tolerance was evaluated by a presyncopal-limited lower body negative pressure test before and after bed rest. The 10 subjects were divided into TOL (n= 5) and INT (n=5) groups for which the orthostatic tolerance was similar and lower after bed rest, respectively. For TOL (INT) before bed rest, calf area increases were 2.2 +/- 0.5 (SE) (1.3 +/- 0.4), 3.5 +/- 0.7 (2.3 +/- 0.5), 5.0 +/- 0.9 (3.5 +/- 0.6), 5.6 +/- 0.9 (4.4 +/- 0.6), and 6.4 +/- 1.1 (4.7 +/- 0.6) sq cm for thigh occlusion pressures of 20, 30, 50, 70, and 80 mmHg, respectively. Neither for INT nor for TOL were these results significantly changed by bed rest. These results suggest that other mechanisms than increased LC have to be taken into account to explain the decreased orthostatic tolerance induced by this 13-day bed rest.

Melchior, Francois M.↗

Concentration and Velocity Gradients in Fluidized Beds

In this work we focus on the height dependence of particle concentration, average velocity components, fluctuations in these velocities and, with the flow turned off, the sedimentation velocity. The latter quantities are measured using Particle Imaging Velocimetry (PIV). The PIV technique uses a 1-megapixel camera to capture two time-displaced images of particles in the bed. The depth of field of the imaging system is approximately 0.5 cm. The camera images a region with characteristic length of 2.6 cm for the small particles and 4.7 cm. for the large particles. The local direction of particle flow is determined by calculating the correlation function for sub-regions of 32 x 32 pixels. The velocity vector map is created from this correlation function using the time between images (we use 15 to 30 ms). The software is sensitive variations of 1/64th of a pixel. We produce velocity maps at various heights, each consisting of 3844 velocities. We break this map into three vertical zones for increased height information. The concentration profile is measured using an expanded (1 cm diameter) linearly polarized HeNe Laser incident on the fluidized bed. A COHU camera (gamma=1, AGC off) with a lens and a polarizer images the transmitted linearly polarized light to minimize the effects of multiply scattered light. The intensity profile (640 X 480 pixels) is well described by a Gaussian fit and the height of the Gaussian is used to characterize the concentration. This value is compared to the heights found for known concentrations. The sedimentation velocity is estimated using by imaging a region near the bottom of the bed and using PIV to measure the velocity as a function of time. With a nearly uniform concentration profile, the time can be converted to height information. The stable fluidized beds are made from large pseudo-monodisperse particles (silica spheres with radii (250-300) microns and (425-500) microns) dispersed in a glycerin/water mix. The Peclet number is sufficiently large that Brownian motion of the particles can be ignored and the Reynolds number sufficiently small that particle inertia is negligible. A packed particle bed is used to randomize and disperse the flowing fluid introduced by a peristaltic pump. The bed itself is a rectangular glass cell 8 cm wide (x), 0.8 cm deep and a height of 30.5 cm (z). The depth of field of the camera is approximately 0.5 cm so depth information is averaged. Over flow fluid is returned to the reservoir making a closed loop system. In these experiments the particles form a sediment approximately 5.7 cm high with the pump off and expand to 22 cm with the pump on. For the smaller particles the pump velocity is .5 millimeters per second and 1.1 millimeters per second for the large particles. At this concentration the bed has a very well defined top where particle concentration rapidly drops to zero.

McClymer, James P.↗

Effect of head-down-tilt bed rest and hypovolemia on dynamic regulation of heart rate and blood pressure

Adaptation to head-down-tilt bed rest leads to an apparent abnormality of baroreflex regulation of cardiac period. We hypothesized that this "deconditioning response" could primarily be a result of hypovolemia, rather than a unique adaptation of the autonomic nervous system to bed rest. To test this hypothesis, nine healthy subjects underwent 2 wk of -6 degrees head-down bed rest. One year later, five of these same subjects underwent acute hypovolemia with furosemide to produce the same reductions in plasma volume observed after bed rest. We took advantage of power spectral and transfer function analysis to examine the dynamic relationship between blood pressure (BP) and R-R interval. We found that 1) there were no significant differences between these two interventions with respect to changes in numerous cardiovascular indices, including cardiac filling pressures, arterial pressure, cardiac output, or stroke volume; 2) normalized high-frequency (0.15-0.25 Hz) power of R-R interval variability decreased significantly after both conditions, consistent with similar degrees of vagal withdrawal; 3) transfer function gain (BP to R-R interval), used as an index of arterial-cardiac baroreflex sensitivity, decreased significantly to a similar extent after both conditions in the high-frequency range; the gain also decreased similarly when expressed as BP to heart rate x stroke volume, which provides an index of the ability of the baroreflex to alter BP by modifying systemic flow; and 4) however, the low-frequency (0.05-0.15 Hz) power of systolic BP variability decreased after bed rest (-22%) compared with an increase (+155%) after acute hypovolemia, suggesting a differential response for the regulation of vascular resistance (interaction, P < 0.05). The similarity of changes in the reflex control of the circulation under both conditions is consistent with the hypothesis that reductions in plasma volume may be largely responsible for the observed changes in cardiac baroreflex control after bed rest. However, changes in vasomotor function associated with these two conditions may be different and may suggest a cardiovascular remodeling after bed rest.

Non-NASA Center↗

Cardiovascular Adaptations to Long Duration Head Down Tilt Bed Rest

Orthostatic hypotension is a recognized risk for crewmembers returning from space. Numerous cardiovascular mechanisms have been proposed to account for this problem including vascular and cardiac dysfunction. We studied arterial and cardiac function in 6-degree head-down tilt bed rest, which is the most widely accepted ground-based analog of spaceflight. Eleven subjects are included in this study (8 men and 3 women). Data analysis was limited to the first 49 days, and compared to pre-bed rest baseline data. Using ultrasound, data was collected on arterial diameters and flows at baseline and during reactive hyperemia and following administration of nitroglycerin. Echocardiography was used to acquire information regarding systolic and diastolic function as well as ventricular mass and diameter. Plasma volumes were significantly decreased by 7 days of bed rest and stayed down through 49 days. There were no differences in reactive hyperemic response in the arm at any time point. However, the hyperemic response in the leg was significantly increased at day 49. Arterial responses to nitroglycerin did not change over the duration of bed rest (day effect) in either the arm or leg, but there was a significant difference between the arm and the leg responses. There was a marked decrease in anterior tibial intimal-medial thickness at days 21, 35 and 49. Several cardiac functional parameters including IVRT, Mitral e-wave, ejection time, velocity of circumferential shortening and myocardial performance index were significantly changed following 49 days of bed rest. These data show that some cardiovascular measures change during bed rest, while others do not. Further study is needed to determine if these measures can provide any insight into the effects of bed rest, or spaceflight, on human cardiovascular performance.

Platts, Steven H.↗

Spool Valve for Switching Air Flows Between Two Beds

U.S. Patent 6,142,151 describes a dual-bed ventilation system for a space suit, with emphasis on a multiport spool valve that switches air flows between two chemical beds that adsorb carbon dioxide and water vapor. The valve is used to alternately make the air flow through one bed while exposing the other bed to the outer-space environment to regenerate that bed through vacuum desorption of CO2 and H2O. Oxygen flowing from a supply tank is routed through a pair of periodically switched solenoid valves to drive the spool valve in a reciprocating motion. The spool valve equalizes the pressures of air in the beds and the volumes of air flowing into and out of the beds during the alternations between the adsorption and desorption phases, in such a manner that the volume of air that must be vented to outer space is half of what it would be in the absence of pressure equalization. Oxygen that has been used to actuate the spool valve in its reciprocating motion is released into the ventilation loop to replenish air lost to vacuum during the previous desorption phase of the operating cycle.

Dean, W. Clark↗

Gradient Compression Stockings may Prevent Recovery after Bed Rest Deconditioning

Introduction: Astronauts continue to wear a compression garment during and immediately after landing to prevent orthostatic intolerance (OI). We recently developed a custom-fitted, 3-piece garment that consists of thigh-high stockings with biker-style shorts that provides continuous, gradient compression: 55 mmHg at the ankle that decreases to approximately 20 mmHg at the top of the leg and 15 mmHg over the abdomen. This garment has been shown to be effective in preventing symptoms of OI during a short stand test after Space Shuttle missions, but symptoms may persist for several days after a long-duration mission in some astronauts. The purpose of this study was to confirm the effectiveness of wearing these elastic, gradient compression garments during orthostatic testing after 2 weeks of 6 degree head-down tilt bed rest as a model of spaceflight and to determine whether they would impact recovery after bed rest. Methods: Eight (5 treatment, 3 control) of 16 subjects have completed this study to-date. All subjects wore the 3-piece garment from waking until tilt testing (~3 h) as a simulation of the timeline for astronauts on landing day (BR+0). Control subjects removed the garment after the tilt test. Treatment subjects wore the garment for the remainder of the day and wore lower compression thigh-high only garments on the day after bed rest (BR+1). Blood pressure, heart rate, and stroke volume responses to a 15-min 80 degree head-up tilt test were determined before 2 weeks of 6 degree head-down tilt, and on BR+0 and BR+1. Plasma volume (PV) was measured before each of these test sessions. Data are mean SE. Results: Compression garments prevented signs of OI on BR+0; all subjects in both groups completed the full 15-min test. Heart rate responses to tilt were lower on BR+0 than all other test days. Control subjects demonstrated a marginal PV decrease after bed rest, but showed typical recovery the day after bed rest (BR+0: 2.32 plus or minus 0.15 L to BR+1: 2.79 plus or minus 0.15 L). Treatment subjects did not recover PV the day after bed rest (BR+0: 2.61 plus or minus 0.23 L to BR+1: 2.61 plus or minus 0.23 L). Conclusion: Abdomen-high compression garments, which are effective in preventing post-bed rest orthostatic intolerance, may slow recovery of PV. Modified garments with reduced compression may be necessary to prevent prolonging recovery.

Stenger, Michael B.↗

Performance Evaluation of the ISS Water Processor Multifiltration Beds

The ISS Water Processor Assembly (WPA) produces potable water from a waste stream containing humidity condensate and urine distillate. The primary treatment process is achieved in the Multifiltration Bed, which includes adsorbent media and ion exchange resin for the removal of dissolved organic and inorganic contaminants. The first Multifiltration Bed was replaced on ISS in July 2010 after initial indication of inorganic breakthrough. This bed was returned to ground in July 2011 for an engineering investigation. The water resident in the bed was analyzed for various parameters to evaluate adsorbent loading, performance of the ion exchange resin, microbial activity, and generation of leachates from the ion exchange resin. Portions of the adsorbent media and ion exchange resin were sampled and subsequently desorbed to identify the primary contaminants removed at various points in the bed. In addition, an unused Multifiltration Bed was evaluated after two years in storage to assess the generation of leachates during storage. This assessment was performed to evaluate the possibility that these leachates are impacting performance of the Catalytic Reactor located downstream of the Multifiltration Bed. The results of these investigations and implications to the operation of the WPA on ISS are documented in this paper.

Bowman, Elizabeth M.↗

Assessment of Service Life for Regenerative ECLSS Resin Beds

The International Space Station (ISS) Water Processor Assembly (WPA) and Oxygen Generation Assembly (OGA) manage and process water at various levels of cleanliness for multiple purposes. The effluent of theWPA and the influent of the OGA require water at very high levels of purity. The bulk of the water purification that occurs in both systems is performed by consumable activated carbon and ion exchange resin beds. Replacement beds must be available on orbit in order to continue the ISS critical processes of water purification and oxygen generation. Various hurdles exist in order to ensure viable spare resin beds. These include the characteristics of resin beds such as: storage environment, shelf life requirements, microbial growth, and variations in the levels and species of contaminants the beds are required to remove. Careful consideration has been given to match water models, bed capacities and spares traffic models to ensure that spares are always viable. The results of these studies and considerations, in particular, how shelf life requirements affect resin bed life management, are documented in this paper.

Cloud, Dale L.↗

Four Bed Molecular Sieve - Exploration (4BMS-X) Virtual Heater Design and Optimization

A 4BMS-X (Four Bed Molecular Sieve - Exploration) design and heater optimization study for CO2 sorbent beds in proposed exploration system architectures is presented. The primary objectives of the study are to reduce heater power and thermal gradients within the CO2 sorbent beds while minimizing channeling effects. Some of the notable changes from the ISS (International Space Station) CDRA (Carbon Dioxide Removal Assembly) to the proposed exploration system architecture include cylindrical beds, alternate sorbents and an improved heater core. Results from both 2D and 3D sorbent bed thermal models with integrated heaters are presented. The 2D sorbent bed models are used to optimize heater power and fin geometry while the 3D models address end effects in the beds for more realistic thermal gradient and heater power predictions.

Schunk, R. Gregory↗

Virtual Design of a 4-Bed Molecular Sieve for Exploration

Simulations of six new 4-Bed Molecular Sieve configurations have been performed using a COMSOL (COMSOL Multiphysics - commercial software) model. The preliminary results show that reductions in desiccant bed size and sorbent bed size when compared to the International Space Station configuration are feasible while still yielding a process that handles at least 4.0 kilograms a day CO2. The results also show that changes to the CO2 sorbent are likewise feasible. Decreasing the bed sizes was found to have very little negative effect on the adsorption process; breakthrough of CO2 in the sorbent bed was observed for two of the configurations, but a small degree of CO2 breakthrough is acceptable, and water breakthrough in the desiccant beds was not observed. Both configurations for which CO2 breakthrough was observed still yield relatively high CO2 efficiency, and future investigations will focus on bed size in order to find the optimum configuration.

Giesy, Timothy J.↗

Virtual Design of a 4-Bed Molecular Sieve for Exploration

Simulations of six new 4-Bed Molecular Sieve configurations have been performed using a COMSOL model. The preliminary results show that reductions in desiccant bed size and sorbent bed size when compared to the International Space Station configuration are feasible while still yielding a process that handles at least 4.0 kg/day CO2. The results also show that changes to the CO2 sorbent are likewise feasible. Decreasing the bed sizes was found to have very little negative effect on the adsorption process; breakthrough of CO2 in the sorbent bed was observed for two of the configurations, but water breakthrough in the desiccant beds was not observed. Nevertheless, both configurations for which CO2 breakthrough was observed still yield relatively high CO2 efficiency, and future investigations will focus on bed size in order to find the optimum configuration.

Giesy, Timothy J.↗

FEASIBILITY STUDY FOR THE DEVELOPMENT OF A TEST BED PROGRAM FOR NOVEL DETECTORS AND DETECTOR MATERIALS AT SRS H-CANYON SEPARATIONS FACILITY

Researchers at the Savannah River National Laboratory (SRNL) have proposed that a test bed for advanced detectors be established at the H-Canyon separations facility located on the DOE Savannah River Site. The purpose of the proposed test bed will be to demonstrate the capabilities of emerging technologies for national and international safeguards applications in an operational environment, and to assess the ability of proven technologies to fill any existing gaps. The need for such a test bed has been expressed in the National Nuclear Security Administration's (NNSA) Next Generation Safeguards Initiative (NGSI) program plan and would serve as a means to facilitate transfer of safeguards technologies from the laboratory to an operational environment. New detectors and detector materials open the possibility of operating in a more efficient and cost effective manner, thereby strengthening national and international safeguards objectives. In particular, such detectors could serve the DOE and IAEA in improving timeliness of detection, minimizing uncertainty and improving confidence in results. SRNL's concept for the H Canyon test bed program would eventually open the facility to other DOE National Laboratories and establish a program for testing national and international safeguards related equipment. The initial phase of the test bed program is to conduct a comprehensive feasibility study to determine the benefits and challenges associated with establishing such a test bed. The feasibility study will address issues related to the planning, execution, and operation of the test bed program. Results from the feasibility study will be summarized and discussed in this paper.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Use of Test Beds to Facilitate Implementation of Innovative Technologies at Complex Sites - 17147

The Department of Energy, Office of Environmental Management (DOE-EM) has invested significant resources targeted at reducing risk to the environment and to the public. Considerable progress has been achieved, yet major remediation challenges remain. DOE-EM recognizes that new, innovative technologies offer the potential to improve operational performance, accelerate schedules, and reduce cost for environmental cleanup. One challenge that often limits the adoption of new technologies is the lack of information about their performance under real-world conditions. This is particularly true of the complex radiological and chemical environments present at many DOE-EM sites. Test-beds provide a useful approach to test new technologies and technical approaches. With the ability to be field-scale, meso-scale, and/or lab-scale in size and scope, test-beds allow scientists and researchers to explore theories, technologies and tools within replicated, 'real-world' physical, chemical and environmental conditions. To address this challenge, DOE-EM is managing a suite of test-beds and prototype test facilities. The focus of test-bed efforts is on several key issues and challenges that confront site operators. Priority environmental remediation concerns are technetium-99, cesium-137, and strontium-90. Additionally, DOE-EM has determined that advanced robotic and remote sensing techniques offer promise in increasing operational efficiency, reducing personnel exposure, and enhancing safety. Savannah River National Laboratory is implementing a test-bed program. Selection of technologies and alignment with test-beds will depend on applicability to DOE-EM issues, technology maturity, a site's ability to host vendors (industry, SBIR, academia, national laboratories), and availability of supporting infrastructure. Viable results are generated through the test-bed process so that these solutions can be utilized in larger-scale thereby facilitating quick implementation of new technologies at DOE sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrodynamics of gas–solids flow in a bubbling fluidized bed with immersed vertical U-tube banks

Our team applies a two-fluid model (TFM) from the open-source code Multiphase Flow with Interphase eXchanges (MFIX) to investigate hydrodynamics in a gas–solids fluidized bed with immersed vertical tubes. The cut-cell method implemented in MFIX is used to fully resolve the flow around vertical U-tube banks. Simulations are performed in a bed diameter of 0.145 m with square and triangular tube arrangements, for inlet gas velocities of U0/Umf = 2.3, 4.5 and 6.8. Simulation results are compared with experimental results from the literature and show very good agreement for the bubble size. The efficiency of vertical tubes in reducing bubble size depends upon inlet gas velocity and tube arrangement. Reduction in bubble size is due to the vertical tubes preventing bubble coalescence and promoting bubble splitting. In-bed vertical tubes result in uniform distribution of bubbles within the bed with increase in bubble frequency. The bubble frequency is higher within the bed for square tube arrangements. For a bed with vertical tubes, the bubble shape is generally elongated, which results in high bubble rise velocity. Axial solid velocity and solids circulation patterns are significantly affected by the vertical tubes, where triangular tube arrangements rarely show any solids circulating zone.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modelling a compressible packed bed flow-through washing and deacetylation reactor for corn stover pretreatment

The deacetylation process is a key step in the lignocellulosic biomass pretreatment process that currently is done in batch reactors. A flow-through diffuser type reactor is a promising approach to make the process more efficient and economically favorable. A washing step before deacetylation can further reduce chemical usage and increase the process efficiency. However, the highly compacted biomass particles can cause significant pressure-drop for fluid flow through the bed, which in the worst case can cause self-enhancing pressure-drop leading to reactor blocking. Detailed understanding of the fundamentals of flow through a compressible packed bed is necessary to scale up the washing and deacetylation process. This work closely examines the classical Kozeny Carman equation and proposes modifications to accurately predict the pressure-drop at different compaction states. Here, a compressible packed bed model is further developed based on the interaction between solid mechanics and fluid dynamics. Experimental measurements of water flow through a packed bed of corn stover show good agreement with the developed model. Corn stover washing process scale up simulations show that smaller reactor diameter, higher friction lining material, lower process throughput, and higher process temperature is favorable in stabilizing the bed from extensive compression when the bed height is fixed.

09 BIOMASS FUELS↗

Lateral solids dispersion coefficient in large-scale fluidized beds

The design of fuel feed ports in a large-scale fluidized bed combustor depends on the fuel characteristics and lateral solids mixing. However, the reported values of the effective lateral solids dispersion coefficient (D{sub sr}) are scattered in the broad range of 0.0001-0.1 m{sup 2}/s. With the aim of predicting D{sub sr} in wider fluidized beds which is difficult to measure directly or deduce from experimental results in lab-scale facilities, a computational method is proposed. It combines the Eulerian-Granular simulation and fictitious particle tracing technique. The value of D{sub sr} is calculated based on the movement of the tracers. The effect on D{sub sr} of bed width (W) ranging from 0.4 m up to 12.8 m at different levels of superficial gas velocity (U{sub 0}) is investigated. It is found that increasing W whilst maintaining U{sub 0}, D{sub sr} initially increases markedly, then its increase rate declines, and finally it stays around a constant value. The computed values of D{sub sr} are examined quantitatively and compared with a thorough list of the measured D{sub sr} in the literature since 1980s. Agreed with the measurements performed in the pilot-scale fluidized beds, the value of D{sub sr} in wider facilities at higher fluidizing velocities is predicted to be around the order of magnitude of 0.1 m{sup 2}/s, much higher than that in lab-scale beds. Finally, the effect of D{sub sr} on the distribution of fuel particles over the cross section in fluidized beds with the specified layout of feed ports is discussed. (author)

42 ENGINEERING↗